Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TIME RESOLUTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

The time resolution domain of stellar radio astronomy

The high time resolution (HTR) radio observation of late-type stars and RS CVn systems is discussed. Some examples of these sources are addressed, identifying what information HTR observations can provide. HTR can provide important information on flares in late-type stars, and can be used to study coronal structure and the particle acceleration mechanism in these stars. The possible use of HTR to establish the nature of quiescent emission form RS CVn systems is discussed.

Bookbinder, J.↗

THE ACS LCID PROJECT. XI. ON THE EARLY TIME RESOLUTION OF SFHs OF LOCAL GROUP DWARF GALAXIES: COMPARING THE EFFECTS OF REIONIZATION IN MODELS WITH OBSERVATIONS

The analysis of the early star formation history (SFH) of nearby galaxies, obtained from their resolved stellar populations, is relevant as a test for cosmological models. However, the early time resolution of observationally derived SFHs is limited by several factors. Thus, direct comparison of observationally derived SFHs with those derived from theoretical models of galaxy formation is potentially biased. Here we investigate and quantify this effect. For this purpose, we analyze the duration of the early star formation activity in a sample of four Local Group dwarf galaxies and test whether they are consistent with being true fossils of the pre-reionization era; i.e., if the quenching of their star formation occurred before cosmic reionization by UV photons was completed. Two classical dSph (Cetus and Tucana) and two dTrans (LGS-3 and Phoenix) isolated galaxies with total stellar masses between 1.3×10{sup 6} and 7.2×10{sup 6} M{sub ⊙} have been studied. Accounting for time resolution effects, the SFHs peak as much as 1.25 Gyr earlier than the optimal solutions. Thus, this effect is important for a proper comparison of model and observed SFHs. It is also shown that none of the analyzed galaxies can be considered a true fossil of the pre-reionization era, although it is possible that the outer regions of Cetus and Tucana are consistent with quenching by reionization.

79 ASTRONOMY AND ASTROPHYSICS↗

Quantitative comparison between sub-millisecond time resolution single-molecule FRET measurements and 10-second molecular simulations of a biosensor protein

Molecular Dynamics (MD) simulations seek to provide atomic-level insights into conformationally dynamic biological systems at experimentally relevant time resolutions, such as those afforded by single-molecule fluorescence measurements. However, limitations in the time scales of MD simulations and the time resolution of single-molecule measurements have challenged efforts to obtain overlapping temporal regimes required for close quantitative comparisons. Achieving such overlap has the potential to provide novel theories, hypotheses, and interpretations that can inform idealized experimental designs that maximize the detection of the desired reaction coordinate. Here, we report MD simulations at time scales overlapping with in vitro single-molecule Förster (fluorescence) resonance energy transfer (smFRET) measurements of the amino acid binding protein LIV-BP SS at sub-millisecond resolution. Computationally efficient all-atom structure-based simulations, calibrated against explicit solvent simulations, were employed for sampling multiple cycles of LIV-BP SS clamshell-like conformational changes on the time scale of seconds, examining the relationship between these events and those observed by smFRET. The MD simulations agree with the smFRET measurements and provide valuable information on local dynamics of fluorophores at their sites of attachment on LIV-BP SS and the correlations between fluorophore motions and large-scale conformational changes between LIV-BP SS domains. We further utilize the MD simulations to inform the interpretation of smFRET data, including Förster radius (R 0 ) and fluorophore orientation factor (κ 2 ) determinations. The approach we describe can be readily extended to distinct biochemical systems, allowing for the interpretation of any FRET system conjugated to protein or ribonucleoprotein complexes, including those with more conformational processes, as well as those implementing multi-color smFRET.

59 BASIC BIOLOGICAL SCIENCES↗

Picosecond Timing Resolution Measurements of Low Gain Avalanche Detectors with a 120 GeV Proton Beam for the TOPSiDE Detector Concept

This paper presents results that take a critical step toward proving 10 ps timing resolution’s feasibility for particle identification in the TOPSiDE detector concept for the Electron-Ion Collider. Measurements of LGADs with a thickness of 35 μm and 50 μm are evaluated with a 120 GeV proton beam. The performance of the gain and timing response is assessed, including the dependence on the reverse bias voltage and operating temperature. The best timing resolution of UFSDs in a test beam to date is achieved using three combined planes of 35 μm thick LGADs at -30°C with a precision of 14.3 ± 1.5 ps.

Particle tracking detectors↗

APES: Acute Precipitating Electron Spectrometer - A High Time Resolution Monodirectional Magnetic Deflection Electron Spectrometer

We present a description of the Acute Precipitating Electron Spectrometer (APES) that was designed and built for the Ground-to-Rocket Electron Electrodynamics Correlative Experiment (GREECE) auroral sounding rocket mission. The purpose was to measure the precipitating electron spectrum with high time resolution, on the order of milliseconds. The trade-off made in order to achieve high time resolution was to limit the aperture to only one look direction. The energy selection was done by using a permanent magnet to separate the incoming electrons, such that the different energies would fall onto different regions of the microchannel plate and therefore be detected by different anodes. A rectangular microchannel plate (MCP) was used (15 mm x 100 mm), and there was a total of 50 discrete anodes under the MCP, each one 15 mm x 1.5 mm, with a 0.5 mm spacing between anodes. The target energy range of APES was 200 eV to 30 keV.

Michell, R. G.↗

Microwave and hard X-ray observations of a solar flare with a time resolution better than 100 ms

Simultaneous microwave and X-ray observations are presented for a solar flare detected on 1980 May 8 starting at 1937 UT. The X-ray observations were made with the Hard X-ray Burst Spectrometer on the Solar Maximum Mission and covered the energy range from 28-490 keV with a time resolution of 10 ms. The microwave observations were made with the 5 and 45 foot antennas at the Itapetinga Radio Obervatory at frequencies of 7 and 22 GHz, with time resolutions of 100 ms and 1 ms respectively. Detailed correlation analysis of the different time profiles of the event show that the major impulsive in the X-ray flux preceded the corresponding microwave peaks at 22 GHz by about 240 ms. For this particular burst the 22 GHz peaks preceded the 7 GHz by about 1.5s. Observed delays of the microwave peaks are too large for a simple electron beam model but they can be reconciled with the speeds of shock waves in a thermal model. Previously announced in STAR as N82-30215

Kaufmann, P.↗

Microwave and hard X-ray observations of a solar flare with a time resolution of better than 100 MS

Simultaneous microwave and X-ray observations are presented for a solar flare detected on 1980 May 8 starting at 1937 UT. The X-ray observations were made with the Hard X-Ray Burst Spectrometer on the Solar Maximum Mission and covered the energy range from 28-490 keV with a time resolution of 10 ms. The microwave observations were made with the 5 and 45 foot antennas at the Itapetinga Radio Observatory at frequencies of 7 and 22 GHz, with time resolutions of 100 ms and 1 ms respectively. Detailed correlation analysis of the different time profiles of the event show that the major impulsive in the X-ray flux preceded the corresponding microwave peaks at 22 GHz by about 240ms. For this particular burst the 22 GHz peaks preceded the 7 GHz by about 1.5s. Observed delays of the microwave peaks are too large for a simple electron beam model but they can be reconciled with the speeds of shock waves in a thermal model.

Kaufmann, P.↗

Development of an integrated four-channel fast avalanche-photodiode detector system with nanosecond time resolution

In this paper, a four-channel nanosecond time-resolved avalanche-photodiode (APD) detector system is developed at Beijing Synchrotron Radiation. It uses a single module for signal processing and readout. This integrated system provides better reliability and flexibility for custom improvement. The detector system consists of three parts: (i) four APD sensors, (ii) four fast preamplifiers and (iii) a time-digital-converter (TDC) readout electronics. The C30703FH silicon APD chips fabricated by Excelitas are used as the sensors of the detectors. It has an effective light-sensitive area of 10 × 10 mm 2 and an absorption layer thickness of 110 μ m. A fast preamplifier with a gain of 59 dB and bandwidth of 2 GHz is designed to readout of the weak signal from the C30703FH APD. The TDC is realized by a Spartan-6 field-programmable-gate-array (FPGA) with multiphase method in a resolution of 1ns. The arrival time of all scattering events between two start triggers can be recorded by the TDC. The detector has been used for nuclear resonant scattering study at both Advanced Photon Source and also at Beijing Synchrotron Radiation Facility. Finally, for the X-ray energy of 14.4 keV, the time resolution, the full width of half maximum (FWHM) of the detector (APD sensor + fast amplifier) is 0.86 ns, and the whole detector system (APD sensors + fast amplifiers + TDC readout electronics) achieves a time resolution of 1.4 ns.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Feasibility study of a high spatial and time resolution beam emission spectroscopy diagnostic for localized density fluctuation measurements in Lithium Tokamak eXperiment-β (LTX-β)

Trapped electron mode (TEM) is the main source of turbulence predicted for the unique operation regime of a flat temperature profile under low-recycling conditions in the LTX-β tokamak, while ion temperature gradient driven turbulence may also occur with gas fueling from the edge. To investigate mainly TEM scale density fluctuations, a high spatial and time resolution 2D beam emission spectroscopy (BES) diagnostic is being developed. Apart from spatially localized density turbulence measurement, BES can provide turbulence flow and flow shear dynamics. This BES system will be realized using an avalanche photodiode-based camera and narrow band interference filter. The system can acquire data at 2 MHz. Simulations with the Simulation of Spectra (SOS) code indicate that a high signal to noise ratio can be achieved with the proposed system. This will enable sampling the density fluctuations at this high time resolution. Finally, the design considerations and system optimization using the SOS code are presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Si-APD linear-array x-ray detector with 10-100 μm spatial and sub-nanosecond time resolution

We developed a silicon avalanche photodiode (Si-APD) linear-array detector to be used for time-resolved X-ray scattering experiments using synchrotron X-rays. The Si-APD linear array consists of 64 pixels (pixel size: 100 × 200 μm{sup 2}) with a pixel pitch of 150 μm and a depletion depth of 10 μm. The multichannel scaler counted X-ray pulses over continuous 2046 time bins for every 0.5 ns and recorded a time spectrum at each pixel with a time resolution of 0.5 ns (FWHM) for 8.0 keV X-rays. Using the detector system, we were able to observe X-ray peaks clearly separated with 2 ns interval in the multibunch-mode operation of the Photon Factory ring. The small-angle X-ray scattering for polyvinylidene fluoride film was also observed with the detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Coincidence velocity map imaging using Tpx3Cam, a time stamping optical camera with 1.5 ns timing resolution

Here, we demonstrate a coincidence velocity map imaging apparatus equipped with a novel time-stamping fast optical camera, Tpx3Cam, whose high sensitivity and nanosecond timing resolution allow for simultaneous position and time-of-flight detection. This single detector design is simple, flexible, and capable of highly differential measurements. We show detailed characterization of the camera and its application in strong field ionization experiments.

79 ASTRONOMY AND ASTROPHYSICS↗

High time resolution characteristics of intermediate ion distributions upstream of the earth's bow shock

High time resolution particle data upstream of the bow shock during time intervals that have been identified as having intermediate ion distributions often show high amplitude oscillations in the ion fluxes of energy 2 and 6 keV. These ion oscillations, observed with the particle instruments of the University of California, Berkeley, on the ISEE 1 and 2 spacecraft, are at the same frequency (about 0.04 Hz) as the magnetic field oscillations. Typically, the 6-keV ion flux increases then the 2-keV flux increases followed by a decrease in the 2-keV flux and then the 6-keV flux decreases. This process repeats many times. Although there is no entirely satisfactory explanation, the presence of these ion flux oscillations suggests that distributions often are misidentified as intermediate ion distributions.

Potter, D. W.↗

Increasing the time resolution of a multichannel scaler.

Description of an economical buffer unit which will extend the time resolution of a multichannel scaler to better than 100 nsec. The buffered multiscaler produces a system which has negligible dead time between the bins even at the highest resolutions. It is suitable for use in any digital signaling averaging application which meets certain conditions.

Silverberg, E. C.↗

A high time resolution study of the solar wind-magnetosphere energy coupling function

A high time resolution study of the relationships between the solar wind-magnetosphere energy coupling function and the total energy dissipation rate of the magnetosphere is made using 5-min average values of solar wind data and of the geomagnetic indices AE and Dst. All the results are essentially the same as those obtained by the earlier studies which were based on the hourly average data set. Therefore, it is confirmed that the magnetosphere is primarily a driven system

Akasofu, S.-I.↗

High time resolution plasma wave and magnetic field observations of the Jovian bow shock

High time resolution (60 ms) Voyager magnetometer and plasma wave measurements of a strong (fast Mach number 16), quasi-perpendicular Jovian bow shock reveal an abrupt change in the plasma wave spectrum at the leading edge of the shock foot. Upstream electron plasma waves terminate at the leading edge, and are replaced by a lower-frequency broadband spectrum of ion-acoustic-like waves, which terminates at the main shock ramp. The clear association with the foot region of the lower frequency component suggests that it is generated by reflected ions. If the upstream plasma waves are generated by an escaping electron heat flux, their termination at the leading edge suggests that electrons are heated by the low-frequency waves in the shock foot.

Moses, S. L.↗