Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “THERMAL NEUTRONS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Tungsten thermal neutron dosimeter

Tungsten-185 activity, which is produced by neutron activation of tungsten-184, determines thermal neutron flux. Radiochemical separation methods and counting techniques for irradiated tungsten provide accurate determination of the radiation exposure.

Ball, L. L.↗

Compilation of detection sensitivities in thermal-neutron activation

Detection sensitivities of the chemical elements following thermal-neutron activation have been compiled from the available experimental cross sections and nuclear properties and presented in a concise and usable form. The report also includes the equations and nuclear parameters used in the calculations.

Wahlgren, M. A.↗

Scintillation properties of diamond powders and feasibility of using them in thermal neutron detectors

Diamond offers unique properties for radiation detection, including high radiation hardness, very low gamma sensitivity, and fast response. Conventional diamond detectors rely on charge collection, but this approach requires ultra-pure single crystals and suffers from radiation-induced degradation. Here, in this work, we demonstrate an alternative approach using diamonds as scintillators for detection of charged particles and thermal neutrons. Prototypes were fabricated from commercially available diamond powders bonded to glass substrates and coupled with 6 LiF converters and silicon photomultipliers (SiPMs) and conventional PMTs. We characterized their scintillation properties under alpha particle excitation, x-ray photoluminescence, and thermal neutrons. The tryout detectors exhibit strong scintillation light signals, nanosecond-scale response times, and neutron detection efficiencies up to approximately 14 %, evaluated by comparison to conventional 3 He detector with known efficiency. These results demonstrate the feasibility of cost-effective, lightweight and robust diamond scintillation detectors for applications in space and planetary science, nuclear security, safeguards and environmental monitoring requiring efficient, robust, gamma-blind neutron detectors.

47 OTHER INSTRUMENTATION↗

Adaptation of Temperature Dependent Thermal Neutron Libraries for Fast On-The-Fly Monte Carlo Sampling at Arbitrary Temperatures

Thermal neutron scattering data is necessary for reactor simulations of thermal reactors, but the data storage required can be unwieldy. This is exacerbated when simulations require a large temperature range, as is the case for accident scenarios and reactor start-up. Previous work conducted at RPI has explored and demonstrated a proof of concept of On-The-Fly (OTF) data storage with light water and crystalline graphite based on ENDF/B-VII.1. This provides an updated data storage paradigm for incoherent inelastic cross-sections that allow the data to be used to generate necessary sampling Cumulative Density Functions (CDFs) for any desired temperature. The work presented in this paper extends the previous work by implementing the proof of concept based on ENDF/B-VIII.0, instead of ENDF/B-VII.1, and to include additional materials, such as beryllium and oxygen in beryllium oxide and the new reactor grades of porous graphite. Completion of this work allows a single thermal data file to represent any thermal scattering event for a given material OTF for the temperature of interest, which greatly reduces the data storage needed with only a marginal cost in the calculation of the CDFs OTF. This paper will review the basic methodologies in generating the OTF data, as well as present the updates and improvements made in the generation process. Application of the methodologies covered in this paper show a significant reduction in the storage requirements for inelastic incoherent scattering events. In which, the evaluated ENDF/B-VIII.0 thermal scattering library can be reduced from 563.1 MB to 10.9 MB for light water and 339.3 MB to 13.6 MB for Be in BeO.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Vertically Self-Oriented, Ultrafast 1D ZnO:Li Nanorods as Scintillators for Thermal Neutron Detection

Detection of special nuclear materials (SNMs) is of vital importance in the prevention of nuclear terrorism and to secure states’ national security. Neutron detection is a particularly useful tool to identify SNM, and neutron-sensitive scintillators have many promising properties, such as ease of use, good time resolution, and high detection efficiency. In this work, we develop highly stable, self-oriented, ultrafast 1D ZnO:Li (and codoped with Al, Ga, and In) nanorods (NRs) as thermal neutron-sensitive scintillators. Lithium-6 has high thermal neutron cross section for the (n, α) reaction in ZnO:Li scintillators which have a vertical nano array design greatly increasing the effective surface area and scintillation efficiency. Cost-effective low-temperature (95 °C) hydrothermal growth is used to obtain highly crystalline ZnO:Li nano scintillators by combining nuclear range data and electron transport mechanisms. Among the studies using low-temperature hydrothermal synthesis and a relatively low annealing temperature (≈350 °C) along with optimized NRs (length ≈ 5–8 μm, mean diameter ≈ 700 nm) for thermal neutron detection, this study reports the shortest scintillation decay time (≈ 470 ps) so far to the best of our knowledge. In conclusion, this nano array scintillator combines the advantages of a low-cost growth technique with environmentally friendly and widely available materials.

Ions↗

Thermal neutron image intensifier tube provides brightly visible radiographic pattern

Vacuum-type neutron image intensifier tube improves image detection in thermal neutron radiographic inspection. This system converts images to an electron image, and with electron acceleration and demagnification between the input target and output screen, produces a bright image viewed through a closed circuit television system.

Berger, H.↗

Comparing Thermal Neutron Scintillators for Use With SiPM-Readout Detectors

Scintillator-based thermal neutron detectors for scientific scattering facilities offer an effective combination of large-area coverage and good spatial resolution. At Oak Ridge National Laboratory, silicon photomultiplier (SiPM)-readout Anger cameras using 6 Li glass scintillators have been developed, but the spatial resolution of these detectors is limited by the relatively low light yield of the glass. Recently, several brighter scintillator compositions with sufficient 6 Li concentration have emerged as promising candidates for higher-resolution imaging. Here, in this work, we evaluate five scintillator materials: GS20, LiF/ZnS:Ag, LiF/ZnO:Zn, LiI:Eu, and Cs 2 LiYCl 6 :Ce, each mounted on a SiPM Anger camera. For each scintillator, the neutron detection efficiency, spatial resolution, and count rate capabilities were measured and compared. Each of the new compositions achieved a spatial resolution better than 0.5 mm, compared to 0.66 mm for GS20, with LiI:Eu reaching the best value of 0.32 mm. Although these compositions improve the spatial resolution of the Anger camera, their longer pulse decay times limit their use in high count rate applications, and the camera’s hardware must be optimized for the different properties of the new scintillators.

Neutron detectors↗

Comparative critical mass calculations for NNL and ENDF/B-VIII.0 - Zirconium hydride thermal neutron scattering laws

Zirconium hydride (ZrH{sub x}) is a moderator material for TRIGA reactors and historical space reactor systems, such as SNAP-10A. Thermal neutron scattering laws (TSL) for two phases of this material, δ and ε, have been previously evaluated by Naval Nuclear Laboratory (NNL) and submitted to the National Nuclear Data Center (NNDC) for inclusion in the US national ENDF/B-VIII.1 nuclear data library. In contrast to the current ENDF/B-VIII.0 TSL evaluations, which consider only a single phase, the new evaluations are derived from separate ab initio calculations for both phases and include coherent elastic effects of the zirconium sublattice. To estimate the impact of these changes to the TSL evaluation of this material, comparative critical mass calculations were performed with MC21 for homogenous mixtures of high-enriched uranium (HEU) and ZrH{sub x} in bare and water reflected sphere configurations. These calculations yield an impact on the estimated critical mass as a function of {sup 235}U loading density with maximum differences as large as 1% - 5% for over-moderated thermal spectrum systems. Consequently, the NNL TSL evaluations are anticipated to have a small impact on criticality calculations of thermal reactor systems regardless of the material phase. Nevertheless, characteristic differences exist in the predicted thermal spectra as function of energy for the two sets of TSL evaluations, which are attributed to difference in the underlying phonon density of states of hydrogen bound in ZrH{sub x}. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Thermal Neutron Cross Section Measurements at the RPI LINAC [Slides]

Cold polyethylene shows adequate capacity for enhancing sub-thermal neutron flux. Cold moderator system produced high quality thermal cross section measurements. Measurements were performed for polyethylene, polystyrene, Plexiglas, yttrium hydride and beryllium and compared with ENDF/B-VIII.0 TSL evaluations. All data reduction for all measurements was finalized. Future work includes completion of necessary journal publications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Godiva IV Thermal Neutron Dosimetry Modeling and Variance Reduction

The transfer of the Godiva IV experiment from the Los Alamos Critical Experiments Facility (LACEF) to the National Critical Experiments Research Center (NCERC) introduced a vastly different experiment room return to the neutron flux. The contribution of the background to the burst neutron energy spectrum is significant in the thermal and epithermal neutron energies. Target materials may be placed in various locations in the Godiva room, or outside of the room, for thermal neutron activation. Modeling of this dosimetry problem in Monte Carlo N-Particle (MCNP) presented a novel challenge compared to previous Godiva IV glory hole irradiation simulations. An advanced dosimetry modeling framework for high efficiency calculations in locations far from the Godiva IV fission source was desired. The mesh-based weight windows and point detector advanced variance reduction techniques in MCNP were implemented and tested using adaptations of the critical experiment benchmark model of the Godiva IV problem. The models were validated against measured activations of Nickel, Indium, Scandium, and Cobalt foils at locations 2 meters from the Godiva IV core. Dosimetry measurements were performed in collaboration with Sandia National Laboratory. The weight windows and point detector variance reduction coupled method resulted in the highest problem efficiency.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Advanced Modeling and Simulations for Evaluation of Thermal Neutron Scattering Materials [Slides]

In this presentation, researchers detail tradeoffs between two simulation suites for thermal neutron scattering data. OXLIMAX + MCViNE provide a more accurate elastic peak shape and NJOY + MCNP have more accurate spectra between phonon mode peaks (most likely due to multiple neutron scattering). Additionally, some outstanding issues with MCViNE are noted, including multiple neutron scattering and non-uniform (Q,E) grid for data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Temperature effects on Thermal Neutron Scattering in Beryllium Metal

Many advanced reactor concepts being considered are characterized by a thermal neutron energy spectrum, which traditional light water reactor systems utilized. Beryllium metal, a material with a long-standing operational history in reactor environments, continues to be of significant interest due to its large scattering cross section, low absorption cross section, and well-characterized behavior under irradiation conditions.

GASKET↗