ARM: Temperature Profiles from Raman Lidar at 10-min averaging interval
Temperature Profiles from Raman Lidar at 10-min averaging interval
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Temperature Profiles from Raman Lidar at 10-min averaging interval
Temperature Profiles from Raman Lidar at 60-min averaging interval
Temperature Profiles from Raman Lidar at 10-min averaging interval
Temperature Profiles from Raman Lidar at 10-min averaging interval
Temperature Profiles from Raman Lidar at 60-min averaging interval
Use of an average fuel temperature is a current practice when modeling fuel for eigenvalue (k-inf) calculations. This is an approximation, as it is known from Heat-transfer methods that a fuel pin having linear power q', will have a temperature that varies radially and has a maximum temperature at the center line [1]. This paper describes an investigation into the effects on k-inf and isotopic concentrations of modeling a fuel pin using a single average temperature versus a radially varying fuel temperature profile. The axial variation is not discussed in this paper. A single fuel pin was modeled having 1, 3, 5, 8, or 10 regions of equal volumes (areas). Fig. 1 shows a model of a 10-ring fuel pin surrounded by a gap and then cladding.
A uniform temperature profile is provided across the width of the core of a ribbon fiber laser or amplifier by the use of insulating elements at the core edges and a spatially variable gain in the fiber core. High average power ribbon fibers, enable a variety of applications such as practical laser cutting and beam combining.
Predicting and matching radiation wave propagation with computational models has proven difficult. Information provided by experiments studying radiation flow has been limited when only radiation breakout is measured. We have developed the COAX (co-axial) diagnostic platform to provide spatial temperature profiles of a radiation wave through low density foams as a more detailed constraint for simulations. COAX uses a standard, laser-driven OMEGA-60 halfraum to drive radiation down a titanium-laden silicon oxide foam. Point-projection X-ray absorption spectroscopy perpendicular to the radiation flow measures the spatial profile of titanium ionization. The spectroscopic measurement utilizes a broadband capsule backlighter. Imaging and streak spectroscopy are used to characterize the size and spectrum of this source. Radiography provides an additional constraint by capturing the developing shock as the radiation flow becomes subsonic. The DANTE diagnostic is used to measure the halfraum temperature. Here, we provide a spectroscopic analysis of COAX data to determine temperature, and we describe experimental sources of uncertainty. The temperature is obtained by comparison to multi-temperature synthetic spectra post-processed from radiation-hydrodynamics simulations. Quantitative comparison between data and synthetic spectra generated from temperature profiles at relevant simulation times enable determination of a peak temperature of 114 ± 8 eV at 265 ± 22.4 μm from the halfraum. This represents an improvement over the temperature uncertainties of previous radiation flow experiments. Further refinements to the spectroscopic analysis could achieve ±4 eV. The combination between space-resolved spectroscopy and radiography enables us to determine the distance from the halfraum of both the radiation front and the shock front at the time of measurement. For the example shown in this paper the radiation front position is 600–630 μm at 3.43 ± 0.16 ns and the shock front position is 633 μm at 3.3 ± 0.24 ns.
Core Ideas Column experiments simulating subsurface environments require control of temperature profiles. A 2‐m‐tall laboratory sediment column reproduced vadose zone thermal and hydraulic conditions. Measured CO 2 profiles show the importance of microbial respiration below the root zone. Transport from the soil surface to groundwater is commonly mediated through deeper portions of the vadose zone and capillary fringe, where variations in temperature and water saturation strongly influence biogeochemical processes. This technical note describes a sediment column design that allows laboratory simulation of thermal and hydrologic conditions found in many field settings. Temperature control is particularly important because room temperature is not representative of most subsurface environments. A 2.0‐m‐tall column was capable of simulating profiles with temperatures ranging from 3 to 22°C, encompassing the full range of seasonal temperature variation observed in the deep vadose zone and capillary fringe of a semiarid floodplain in western Colorado. The water table was varied within the lower 0.8‐m section of the column, and profiles of water content and matric potential were measured. Vadose zone CO 2 collected from depth‐distributed gas samplers under representative seasonal conditions reflected the influences of temperature and water table depth on microbial respiration. Thus, realistic subsurface biogeochemical dynamics can be simulated in the laboratory through establishing column profiles that represent seasonal thermal and hydrologic conditions.
The temperature profile of two different BSCCO 2212 coils has been analyzed. The profiles are obtained from thermocouples imbedded in the windings during the heat treatment that activates the 2212. The melting and freezing of the 2212 is clearly observed. A model that describes the data and can be used to guide the processing of new coils has been developed. We have obtained the thermal history of two BSCCO coils, one from NHMFL (1) that had 10 layers of 1 mm diameter wire with 0.15 mm insulation and a second coil from OST that had 24 layers with similar insulation and conductor size. Both coils had thermocouples imbedded in the windings and excellent recordings of the temperature over the whole reaction cycle were available for analysis. There are several features that we will address in this note. Measurements have shown that the I{sub c} of the conductor is a sensitive function of its thermal history. This brings up the question of the absolute accuracy of the thermometry in the range around 882 C, the MP of 2212. The reference for the treatment profile is really related to this MP and to small deviations around it. Since the heat of fusion of 2212 is rather large, it generates a clear signal during the melting and cooling transition that automatically generates the relative temperature markers. The physics is the same as the way ice in water maintains an isothermal environment until it is all melted. A related question is the thermal response time of the coil package. The temperature cycles that are being used to optimize strand and small coils can have rapid changes easily implemented whereas a large coil may have such a large thermal time constant that the optimum cycle may not be attainable. A simple analytical model that works well for small solenoids has been developed and an ANSYS (5) program that works for larger coils with more complicated geometry has been set up but will not be discussed in this note.
The rate of waste vitrification in an electric melter is connected to the feed-to-glass conversion process, which occurs in the cold cap, a layer of reacting feed on top of molten glass. The cold cap consists of two layers: a low-temperature (∼100 deg. C - ∼800 deg. C) region of unconnected, reacting feed and a high-temperature (∼800 deg. C - ∼1100 deg. C) region of molten glass with gas bubbles and cavities. A recently developed mathematical model describes the effect of the cold cap on glass production. For verification of the mathematical model, a cold cap produced in a laboratory-scale melter was subsequently analyzed by correlating structural features of a polished region with those obtained in heat-treated feed samples to determine the temperature profile as a function of cold-cap position. After corrections were made for the diminished volume of bubbles and collapsed cavities that occurred in the cold-cap sample during cooling, the temperature gradients were alike in the model and the laboratory cold cap through the range from ∼500 deg. C to ∼1100 deg. C. The temperature profiles were different in the upper region of the cold cap because the radiant heat from the molten glass in the laboratory-scale melter resulted in dry and hot (∼400 deg. C) surface conditions whereas the model assumed a surface covered by boiling slurry. (authors)
The ability of optical floating zone (OFZ) furnaces to rapidly produce large single crystals of complex emerging materials has had a transformative effect on many scientific fields that require samples of this type. However, the crystal growth process within the OFZ furnace is not well understood owing to the challenges involved in monitoring the high-temperature crystal growth process. Novel beamline-compatible optical furnaces that approximate the inhomogeneous growth environment within an OFZ furnace have been fabricated and tested in high-energy synchrotron beamlines. In this paper, it is demonstrated that temperature profiles can be effectively extracted from powder diffraction data collected on polycrystalline ceramic rods heated at their tip. Furthermore, these measured temperature profiles can be accurately reproduced using a heat-transfer model that accounts for solid-state thermal conduction, partial sample lamp power absorption, convective air cooling and radiative cooling, allowing key thermal parameters such as thermal conductivity to be extracted from experimental data.
Future tokamak reactor operation will require the ability to maintain a given plasma scenario for extended periods of time. This will necessitate the capability to react to changes in the plasma state and return the plasma to the target scenario; the principal method to achieve this is through feedback control. Thus, it is necessary to develop and test feedback controllers for the plasma profiles that define a target scenario. In this work, a feedback controller for the electron temperature (Te) profile is tested experimentally in DIII-D. This experiment relied on the ability to ascertain the electron temperature profile in real time, which was achieved using an observer algorithm. The observer relies on both diagnostic data and a predictive model of the electron temperature profile evolution; this predictive model includes contributions from neural network surrogate models. Because of these dependencies, a number of capabilities needed to be added to the real-time PCS for DIII-D in order to support the Te profile control experiment. The neural network surrogates needed to be integrated into the PCS to be called in real time. An observer algorithm for the Te profile needed to be added and connected to the Thomson scattering system to allow access to the current state of the profile in real time. When tested, the observer was shown to produce Te profiles that are consistent with the shape of the Thomson scattering data while rejecting much of the noise in the diagnostic data. Finally, the controller itself was tested in real time. This experiment showed that the controller is capable of tracking the electron temperature target at locations across the spatial profile.
The bulk of solar coronal radiative loss consists of soft X-ray emission from quasi-static loops at the cores of active regions. In order to develop diagnostics for determining the heating mechanism of these loops from observations by coronal imaging instruments, I have developed analytical solutions for the temperature structure and scaling laws of loop strands for a set of temperature- and pressure-dependent heating functions that encompass heating concentrated at the footpoints, uniform heating, and heating concentrated at the loop apex. Key results are that the temperature profile depends only weakly on the heating distribution-not sufficiently to be of significant diagnostic value-and that the scaling laws survive for this wide range of heating distributions, but with the constant of proportionality in the Rosner-Tucker-Vaiana scaling law (P{sub 0} L {approx} T {sup 3}{sub max}) depending on the specific heating function. Furthermore, quasi-static solutions do not exist for an excessive concentration of heating near the loop footpoints, a result in agreement with recent numerical simulations. It is demonstrated that a generalization of the results to a set of solutions for strands with a functionally prescribed variable diameter leads to only relatively small correction factors in the scaling laws and temperature profiles for constant diameter loop strands. A quintet of leading theoretical coronal heating mechanisms is shown to be captured by the formalism of this paper, and the differences in thermal structure between them may be verified through observations. Preliminary results from full numerical simulations demonstrate that, despite the simplifying assumptions, the analytical solutions from this paper are accurate and stable.
Time-dependent, predictive simulations were performed with the 1.5D tokamak integrated modeling code TRANSP on a large set of well-analyzed, high performing discharges from the National Spherical Torus Experiment (NSTX) in order to evaluate how well modern reduced transport models can reproduce experimentally observed temperature profiles in spherical tokamaks. Overall, it is found that simulations using the Multi-Mode Model (MMM) more consistently agree with the NSTX observations than those using the Trapped Gyro-Landau Fluid (TGLF) model, despite TGLF requiring orders of magnitude greater computational cost. When considering all examined discharges, MMM has median overpredictions of electron temperature (T e ) and ion temperature (T i ) profiles of 28% and 27%, respectively, relative to the experiment. TGLF overpredicts T e by 46%, with much larger variance than MMM, and underpredicts T i by 25%. As the ratio of kinetic to magnetic field pressure (β) is increased across NSTX discharges, TGLF predicts lower T e and significant flattening of the T i profile, conflicting with NSTX observations. When using an electrostatic version of TGLF, both T e and T i are substantially overpredicted, underscoring the importance of electromagnetic turbulence in the high β spherical tokamak regime. Additionally, calculations with neural net surrogate models for TGLF were performed outside of TRANSP with a time slice flux matching transport solver, finding better agreement with experiment than the TRANSP simulations, highlighting the impact of different transport solvers and simulation techniques. Furthermore, the reasonable agreement with experiment of temperature profiles predicted by MMM motivates a more detailed examination of the sensitivities of the TRANSP simulations with MMM to different NSTX plasma regimes in a companion paper (Lestz et al Plasma Phys. Control. Fusion 67 105030), in preparation for self-consistent, time-dependent predictive modeling of NSTX-U scenarios.
The self-similar expansion of a collisionless plasma, with an externally tailored electron temperature profile, is studied analytically in quasineutral approximation. It is shown that the tailoring of electron plasma temperature can lead to an ion bunch formation concentrated in phase space. Experimentally, it may correspond to the expansion of a thin foil target driven by multiple laser pulses. A one-dimensional particle-in-cell simulation of thin foil expansion driven by two laser pulses is carried out that evidences the quasimonoenergetic ions generation, thus qualitatively confirming the analytical theory.
The reported soil temperature profile measurements (24 locations - 2 probes with 5 and 6 thermistors, respectively - Fig. 1 and Fig. 2) were initiated as part of a soil micro-warming experiment at the Council Road Mile Marker 71 Site (CN_MM71) in September 2017. From 2017 through August 2019, these were measurements of ambient pre-treatment plot conditions. This tussock tundra site (with underlying permafrost) experiences annual frost heaving that causes a vertical movement of the ground surface, hence causing some of the upper most temperature thermistors to be at surface level or above ground and recorded therefore air temperatures near the surface and not below ground soil temperature (see section on Quality Assurance). After August 2019, these measurements ended in preparation for transitioning to the experimental warming of individual plots. The reported temperature data are nominally 3-hour averages of measurements made at varying frequencies (3-hour maximum) with frequencies that depended upon power (solar) availability to operate the sensors (see section in documentation on Methods). The number of values and the standard deviation for each 3-hour average (where appropriate) are also provided. These measurements are located near the NGEE-Arctic CO2 and CH4 eddy covariance tower at the Council Road Site (US-NGC: NGEE Arctic Council, https://ameriflux.lbl.gov/sites/siteinfo/US-NGC#overview) and auxiliary data at https://doi.org/10.5440/1526749. This dataset contains four *.csv files and one *.pdf file. The Next-Generation Ecosystem Experiments: Arctic (NGEE Arctic), was a research effort to reduce uncertainty in Earth System Models by developing a predictive understanding of carbon-rich Arctic ecosystems and feedbacks to climate. NGEE Arctic was supported by the Department of Energy's Office of Biological and Environmental Research. The NGEE Arctic project had two field research sites: 1) located within the Arctic polygonal tundra coastal region on the Barrow Environmental Observatory (BEO) and the North Slope near Utqiagvik (Barrow), Alaska and 2) multiple areas on the discontinuous permafrost region of the Seward Peninsula north of Nome, Alaska. Through observations, experiments, and synthesis with existing datasets, NGEE Arctic provided an enhanced knowledge base for multi-scale modeling and contributed to improved process representation at global pan-Arctic scales within the Department of Energy's Earth system Model (the Energy Exascale Earth System Model, or E3SM), and specifically within the E3SM Land Model component (ELM).
Three-dimensional simulation is used to theoretically assess temperature profiles in proposed 10-mm-wide cw laser diode bars packaged in a standard heat spreader of the C – S mount type with the aim of raising their reliable cw output power. We obtain calculated temperature differences across the emitting aperture and along the cavity. Using experimental laser bar samples with up to 60 W of cw output power, the emission spectra of individual clusters are measured at different pump currents. We compare and discuss the simulation results and experimental data. The bibliography includes 9 references. (lasers)