Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TECHNOLOGISTS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Health Literacy and Patient Preparation in Radiology

Health literacy is the capacity of an individual to obtain, process, and understand basic health information and services needed to make appropriate health decisions. Unfortunately, more than half of Canadians cannot adequately navigate the health care system because they have limited health literacy. Patients with low health literacy may have limited reading abilities and poorer comprehension of written preparation documents. An important consideration in the radiation sciences for these patients is the ability to follow preparation requirements for diagnostic imaging procedures. It has been suggested that patients with limited health literacy are often less prepared for diagnostic examinations, and as a result, tend to have examinations of poorer diagnostic quality. Medical radiation technologists play an important role in educating patients regarding medical imaging examinations and helping them to properly prepare for these procedures. The purpose of this article is to define health literacy, provide some practical strategies to help medical radiation technologists identify patients with limited health literacy, and how to address limited health literacy issues to improve the quality of diagnostic imaging examinations.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Trial of a proposed protocol for constancy control of digital mammography systems

Purpose: Evaluate the utility of tests in a proposed protocol for constancy control of digital mammography systems. Methods: The protocol contained tests for image acquisition, mechanical function and safety, monitors and printers, and viewing conditions. Nine sites with digital systems from four equipment manufacturers were recruited. Dedicated PMMA test objects and Excel spreadsheets were developed. Quantitative measurements were done on processed images for systems where these images were the ones most readily available. For daily assessment of the automatic exposure control system, a homogeneous PMMA phantom was exposed under clinical conditions. The mAs and signal to noise ratio (SNR) were recorded, the deviation from a target value calculated, and the resulting image inspected for artifacts. For thickness tracking, the signal difference to noise ratio obtained for three thicknesses was calculated. Detector uniformity was assessed through comparison of SNR values for regions of interest in the center and corners of an image of a homogeneous test object. Mechanical function and safety control included a compression test, a checklist for mechanical aspects, and control of field alignment. Monitor performance was evaluated by visual inspection of the AAPM TG 18 QC test image [E. Samei et al., ''Assessment of display performance for medical imaging systems,'' Task Group 18 (Madison, WI, April 2005)]. Results: For quantitative parameters, target values and tolerance limits were established. Test results exceeding the limits were registered. Most systems exhibited stable mAs values, indicating that the tolerance limit of {+-}10% was readily achievable. The SNR also showed little variation, indicating that the tolerance limit of {+-}20% was too wide. At one site, a defective grid caused artifacts that were visible in the test images. The monitor controls proved more difficult to implement due to both difficulties importing and displaying the test image, and the radiographic technologists not getting necessary access to the reading stations. Conclusions: The proposed tests could easily be performed by trained radiographic technologists and within a time frame comparable to similar programs for analog systems. Tests with quantitative measures were more readily performed than procedures that required a subjective evaluation. Several of the proposed tests revealed equipment performance that required intervention, and which would otherwise have gone unnoticed. They therefore defend a place in a vendor-independent constancy control protocol.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-I-68: Practical Considerations On Implementation of the Image Gently Pediatric CT Protocols

Purpose: One limitation associated with the Image Gently pediatric CT protocols is practical implementation of the recommended manual techniques. Inconsistency as a result of different practice is a possibility among technologist. An additional concern is the added risk of data error that would result in over or underexposure. The Automatic Exposure Control (AEC) features automatically reduce radiation for children. However, they do not work efficiently for the patients of very small size and relative large size. This study aims to implement the Image Gently pediatric CT protocols in the practical setting while maintaining the use of AEC features for pediatric patients of varying size. Methods: Anthropomorphological abdomen phantoms were scanned in a CT scanner using the Image Gently pediatric protocols, the AEC technique with a fixed adult baseline, and automatic protocols with various baselines. The baselines were adjusted corresponding to patient age, weight and posterioranterior thickness to match the Image Gently pediatric CT manual techniques. CTDIvol was recorded for each examination. Image noise was measured and recorded for image quality comparison. Clinical images were evaluated by pediatric radiologists. Results: By adjusting vendor default baselines used in the automatic techniques, radiation dose and image quality can match those of the Image Gently manual techniques. In practice, this can be achieved by dividing pediatric patients into three major groups for technologist reference: infant, small child, and large child. Further division can be done but will increase the number of CT protocols. For each group, AEC can efficiently adjust acquisition techniques for children. This implementation significantly overcomes the limitation of the Image Gently manual techniques. Conclusion: Considering the effectiveness in clinical practice, Image Gently Pediatric CT protocols can be implemented in accordance with AEC techniques, with adjusted baselines, to achieve the goal of providing the most appropriate radiation dose for pediatric patients of varying sizes.

60 APPLIED LIFE SCIENCES↗

SU-E-I-88: Mammography Imaging: Does Positioning Matter?

Purpose: In mammography, compression is imperative for quality images and glandular radiation exposure dose. The thickness of the compressed breast directly determines mammography acquisition parameters. The compressed thickness varies due to variation in technologist practice, even for the same patient imaged at different time. This study is to investigate potential effect of the variation in breast positioning on radiation dose and image quality. Methods: Radiation dose at different thicknesses was measured with a BR-12 breast phantom for both conventional craniocaudal view and tomosynthesis in a Hologic Tomosynthesis mammography system. The CIRS stereotactic needle biopsy training phantom embedded dense masses and microcalcification in various sizes were imaged for image quality evaluation. Radiologists evaluated images. Clinical mammograms from the same patient but acquired at different time were retrospectively retrieved to evaluate potential effects of variation in positioning. Results: Acquisition parameters (kVp and mAs) increase with the increased phantom thickness. Radiation exposure increases following an exponential trend. The stereotactic phantom images showed loss of spatial and contrast resolution with inappropriate positioning. The compressed pressure may not be a good indicator for appropriate positioning. The inclusion of different amount of pectoralis muscle may lead to the same compressed pressure but different compressed thickness. The initial retrospective study of 3 patients showed that there were potential large variations in positioning the same patient at different examination time, resulting in large variations in patient radiation dose and image quality. Conclusion: Variations in patient positioning potentially influence patient radiation dose and image quality. The technologist has the critical responsibility to position patient to provide quality images in spite of different breast and body types. To reduce intra and inter practice variations in positioning patient, a training program among each breast imaging center may be a need.

60 APPLIED LIFE SCIENCES↗

MO-F-16A-06: Implementation of a Radiation Exposure Monitoring System for Surveillance of Multi-Modality Radiation Dose Data

Purpose: We have implemented a commercially available Radiation Exposure Monitoring System (REMS) to enhance the processes of radiation dose data collection, analysis and alerting developed over the past decade at our sites of practice. REMS allows for consolidation of multiple radiation dose information sources and quicker alerting than previously developed processes. Methods: Thirty-nine x-ray producing imaging modalities were interfaced with the REMS: thirteen computed tomography scanners, sixteen angiography/interventional systems, nine digital radiography systems and one mammography system. A number of methodologies were used to provide dose data to the REMS: Modality Performed Procedure Step (MPPS) messages, DICOM Radiation Dose Structured Reports (RDSR), and DICOM header information. Once interfaced, the dosimetry information from each device underwent validation (first 15–20 exams) before release for viewing by end-users: physicians, medical physicists, technologists and administrators. Results: Before REMS, our diagnostic physics group pulled dosimetry data from seven disparate databases throughout the radiology, radiation oncology, cardiology, electrophysiology, anesthesiology/pain management and vascular surgery departments at two major medical centers and four associated outpatient clinics. With the REMS implementation, we now have one authoritative source of dose information for alerting, longitudinal analysis, dashboard/graphics generation and benchmarking. REMS provides immediate automatic dose alerts utilizing thresholds calculated through daily statistical analysis. This has streamlined our Closing the Loop process for estimated skin exposures in excess of our institutional specific substantial radiation dose level which relied on technologist notification of the diagnostic physics group and daily report from the radiology information system (RIS). REMS also automatically calculates the CT size-specific dose estimate (SSDE) as well as provides two-dimensional angulation dose maps for angiography/interventional procedures. Conclusion: REMS implementation has streamlined and consolidated the dosimetry data collection and analysis process at our institutions while eliminating manual entry error and providing immediate alerting and access to dosimetry data to both physicists and physicians. Brent Stewart has funded research through GE Healthcare.

60 APPLIED LIFE SCIENCES↗

TH-C-18A-08: A Management Tool for CT Dose Monitoring, Analysis, and Protocol Review

Purpose: To develop a customizable tool for enterprise-wide managing of CT protocols and analyzing radiation dose information of CT exams for a variety of quality control applications Methods: All clinical CT protocols implemented on the 11 CT scanners at our institution were extracted in digital format. The original protocols had been preset by our CT management team. A commercial CT dose tracking software (DoseWatch,GE healthcare,WI) was used to collect exam information (exam date, patient age etc.), scanning parameters, and radiation doses for all CT exams. We developed a Matlab-based program (MathWorks,MA) with graphic user interface which allows to analyze the scanning protocols with the actual dose estimates, and compare the data to national (ACR,AAPM) and internal reference values for CT quality control. Results: The CT protocol review portion of our tool allows the user to look up the scanning and image reconstruction parameters of any protocol on any of the installed CT systems among about 120 protocols per scanner. In the dose analysis tool, dose information of all CT exams (from 05/2013 to 02/2014) was stratified on a protocol level, and within a protocol down to series level, i.e. each individual exposure event. This allows numerical and graphical review of dose information of any combination of scanner models, protocols and series. The key functions of the tool include: statistics of CTDI, DLP and SSDE, dose monitoring using user-set CTDI/DLP/SSDE thresholds, look-up of any CT exam dose data, and CT protocol review. Conclusion: our inhouse CT management tool provides radiologists, technologists and administration a first-hand near real-time enterprise-wide knowledge on CT dose levels of different exam types. Medical physicists use this tool to manage CT protocols, compare and optimize dose levels across different scanner models. It provides technologists feedback on CT scanning operation, and knowledge on important dose baselines and thresholds.

60 APPLIED LIFE SCIENCES↗

SU-E-E-07: An Adaptable Approach for Education On Medical Physics at Undergraduate and Postgraduate Levels

Purpose: To contribute to the professional profile of future medical physicists, technologists and physicians, and implement an adaptable educational strategy at both undergraduate and postgraduate levels. Methods: The Medical Physics Block of Electives (MPBE) designed was adapted to the Program of B.S. in Physics. The conferences and practical activities were developed with participatory methods, with interdisciplinary collaboration from research institutions and hospitals engaged on projects of Research, Development and Innovation (RDI). The scientific education was implemented by means of critical analysis of scientific papers and seminars where students debated on solutions for real research problems faced by medical physicists. This approach included courses for graduates not associated to educational programs of Medical Physics (MP). Results: The implementation of the MPBE began in September 2014, with the electives of Radiation MP and Introduction to Nuclear Magnetic Resonance. The students of second year received an Introduction to MP. This initiative was validated by the departmental Methodological Workshop, which promoted the full implementation of the MPBE. Both postgraduated and undergraduate trainees participated in practices with our DICOM viewer system, a local prototype for photoplethysmography and a home-made interface for ROC analysis, built with MATLAB. All these tools were designed and constructed in previous RDI projects. The collaborative supervision of University’s researchers with clinical medical physicists will allow to overcome the limitations of residency in hospitals, to reduce the workload for clinical supervisors and develop appropriate educational activities. Conclusion: We demonstrated the feasibility of adaptable educational strategies, considering available resources. This provides an innovative way for prospective medical physicists, technologists and radiation oncologists. This strategy can be implemented in several regions without formal programs of MP, like most of developing countries. Starting with undergraduate students would allow to reach appropriate certification faster than most of traditional or alternative approaches for education on MP. The authors acknowledge Radiation Consulting Group, LLC, an Arizona Corporation which promotes the use of ionizing radiation in the healing arts, for the “Oscar Luis Caballero” travel grant. The authors thanks to professors Meisbel Daudinot, David Adame and Alexander Pascau for the practices through imagis, imageROC and ANGIODIN PD3000 respectively.

60 APPLIED LIFE SCIENCES↗

SU-E-I-29: Care KV: Dose It Influence Radiation Dose in Non-Contrast Examination of CT Abdomen/pelvis?

Purpose: CARE kV is a tool that automatically recommends optimal kV setting for individual patient for specific CT examination. The use of CARE kV depends on topogram and the user-selected contrast behavior. CARE kV is expected to reduce radiation dose while improving image quality. However, this may work only for certain groups of patients and/or certain CT examinations. This study is to investigate the effects of CARE kV on radiation dose of non-contrast examination of CT abdomen/pelvis. Methods: Radiation dose (CTDIvol and DLP) from patients who underwent abdomen/pelvis non-contrast examination with and without CARE kV were retrospectively reviewed. All patients were scanned in the same scanner (Siemens Somatom AS64). To mitigate any possible influences due to technologists’ unfamiliarity with the CARE kV, the data with CARE kV were retrieved 1.5 years after the start of CARE kV usage. T-test was used for significant difference in radiation dose. Results: Volume CTDIs and DLPs from 18 patients before and 24 patients after the use of CARE kV were obtained in a duration of one month. There is a slight increase in both average CTDIvol and average DLP with CARE kV compared to those without CARE kV (25.52 mGy vs. 22.65 mGy for CTDIvol; 1265.81 mGy-cm vs. 1199.19 mGy-cm). Statistically there was no significant difference. Without CARE kV, 140 kV was used in 9 of 18 patients, while with CARE KV, 140 kV was used in 15 of 24 patients. 80kV was not used in either group. Conclusion: The use of CARE kV may save time for protocol optimization and minimize variability among technologists. Radiation dose reduction was not observed in non-contrast examinations of CT abdomen/pelvis. This was partially because our CT protocols were tailored according to patient size before CARE kV and partially because of large size patients.

60 APPLIED LIFE SCIENCES↗

TU-H-206-01: An Automated Approach for Identifying Geometric Distortions in Gamma Cameras

Purpose: To develop a clinically-deployable, automated process for detecting artifacts in routine nuclear medicine (NM) quality assurance (QA) bar phantom images. Methods: An artifact detection algorithm was created to analyze bar phantom images as part of an ongoing QA program. A low noise, high resolution reference image was acquired from an x-ray of the bar phantom with a Philips Digital Diagnost system utilizing image stitching. NM bar images, acquired for 5 million counts over a 512×512 matrix, were registered to the template image by maximizing mutual information (MI). The MI index was used as an initial test for artifacts; low values indicate an overall presence of distortions regardless of their spatial location. Images with low MI scores were further analyzed for bar linearity, periodicity, alignment, and compression to locate differences with respect to the template. Findings from each test were spatially correlated and locations failing multiple tests were flagged as potential artifacts requiring additional visual analysis. The algorithm was initially deployed for GE Discovery 670 and Infinia Hawkeye gamma cameras. Results: The algorithm successfully identified clinically relevant artifacts from both systems previously unnoticed by technologists performing the QA. Average MI indices for artifact-free images are 0.55. Images with MI indices < 0.50 have shown 100% sensitivity and specificity for artifact detection when compared with a thorough visual analysis. Correlation of geometric tests confirms the ability to spatially locate the most likely image regions containing an artifact regardless of initial phantom orientation. Conclusion: The algorithm shows the potential to detect gamma camera artifacts that may be missed by routine technologist inspections. Detection and subsequent correction of artifacts ensures maximum image quality and may help to identify failing hardware before it impacts clinical workflow. Going forward, the algorithm is being deployed to monitor data from all gamma cameras within our health system.

60 APPLIED LIFE SCIENCES↗

International Clean Energy Coalition

In 2003, the National Association of Regulatory Utility Commissioners (NARUC) and National Energy Technology Laboratories (NETL) collaboratively established the International Clean Energy Coalition (ICEC). The coalition consisting of energy policy-makers, technologists, and financial institutions was designed to assist developing countries in forming and supporting local approaches to greenhouse gas mitigation within the energy sector. ICEC's work focused on capacity building and clean energy deployment in countries that rely heavily on fossil-based electric generation. Under ICEC, the coalition formed a steering committee consisting of NARUC members and held a series of meetings to develop and manage the workplan and define successful outcomes for the projects. ICEC identified India as a target country for their work and completed a country assessment that helped ICEC build a framework for discussion with Indian energy decisionmakers including two follow-on in-country workshops. As of the conclusion of the project in 2010, ICEC had also conducted outreach activities conducted during United Nations Framework Convention on Climate Change (UNFCCC) Ninth Conference of Parties (COP 9) and COP 10. The broad goal of this project was to develop a coalition of decision-makers, technologists, and financial institutions to assist developing countries in implementing affordable, effective and resource appropriate technology and policy strategies to mitigate greenhouse gas emissions. Project goals were met through international forums, a country assessment, and in-country workshops. This project focused on countries that rely heavily on fossil-based electric generation.

54 ENVIRONMENTAL SCIENCES↗

DOE's National Solar Thermal Test Facility Operations and Maintenance (Final Report FY19-21)

Sandia National Laboratories has been tasked to operate and maintain the National Solar Thermal Test Facility (NSTTF) located in Kirtland Airforce Base near Albuquerque, NM. The NSTTF provides established test platforms and experienced researchers and technologists in the field of Concentrating Solar Technologies (CST) and Concentrating Solar Power (CSP). This three-year project seeks to maintain the NSTTF for development, testing, and application of new CSP technologies that are instrumental in advancing the state-of-the-art in support of SunShot and Generation 3 CSP technology goals. In turn, these technologies will form the foundation of the global CSP industry and continue to advance the technology to new levels of efficiency, higher temperatures, lower costs, lower risk, and higher reliability. The NSTTF provides established test platforms and highly experienced researchers and technologists in the CSP field.

14 SOLAR ENERGY↗

An optimum organizational structure for a large earth-orbiting multidisciplinary Space Base

The purpose of this exploratory study was to identify an optimum hypothetical organizational structure for a large earth-orbiting multidisciplinary research and applications (R&A) Space Base manned by a mixed crew of technologists. Since such a facility does not presently exist, in situ empirical testing was not possible. Study activity was, therefore, concerned with the identification of a desired organizational structural model rather than the empirical testing of it. The essential finding of this research was that a four-level project type 'total matrix' model will optimize the efficiency and effectiveness of Space Base technologists.

Ragusa, J. M.↗

An optimum organizational structure for a large earth-orbiting multidisciplinary space base

An optimum hypothetical organizational structure was studied for a large earth-orbiting, multidisciplinary research and applications space base manned by a crew of technologists. Because such a facility does not presently exist, in situ empirical testing was not possible. Study activity was, therefore, concerned with the identification of a desired organizational structural model rather than with the empirical testing of the model. The essential finding of this research was that a four-level project type total matrix model will optimize the efficiency and effectiveness of space base technologists.

Ragusa, J. M.↗

A methodology for selecting optimum organizations for space communities

This paper suggests that a methodology exists for selecting optimum organizations for future space communities of various sizes and purposes. Results of an exploratory study to identify an optimum hypothetical organizational structure for a large earth-orbiting multidisciplinary research and applications (R&A) Space Base manned by a mixed crew of technologists are presented. Since such a facility does not presently exist, in situ empirical testing was not possible. Study activity was, therefore, concerned with the identification of a desired organizational structural model rather than the empirical testing of it. The principal finding of this research was that a four-level project type 'total matrix' model will optimize the effectiveness of Space Base technologists. An overall conclusion which can be reached from the research is that application of this methodology, or portions of it, may provide planning insights for the formal organizations which will be needed during the Space Industrialization Age.

Ragusa, J. M.↗

Project communications/documentation standards manual

The standards apply to the identification and description of remote sensing technical crop estimation analysis procedures. Standard working terminology for technical project and programmatic communications among and between FCPF project technologists and managers as well as with other AgRISTARS projects and program management is established. Basic reference material for FCPF project technologists is provided. The material presented can be used as introductory training material for new technical personnel.

Waggoner, J. T.↗

International Space Station: Expedition 2000

Live footage of the International Space Station (ISS) presents an inside look at the groundwork and assembly of the ISS. Footage includes both animation and live shots of a Space Shuttle liftoff. Phil West, Engineer; Dr. Catherine Clark, Chief Scientist ISS; and Joe Edwards, Astronaut, narrate the video. The first topic of discussion is People and Communications. Good communication is a key component in our ISS endeavor. Dr. Catherine Clark uses two soup cans attached by a string to demonstrate communication. Bill Nye the Science Guy talks briefly about science aboard the ISS. Charlie Spencer, Manager of Space Station Simulators, talks about communication aboard the ISS. The second topic of discussion is Engineering. Bonnie Dunbar, Astronaut at Johnson Space Flight Center, gives a tour of the Japanese Experiment Module (JEM). She takes us inside Node 2 and the U.S. Lab Destiny. She also shows where protein crystal growth experiments are performed. Audio terminal units are used for communication in the JEM. A demonstration of solar arrays and how they are tested is shown. Alan Bell, Project Manager MRMDF (Mobile Remote Manipulator Development Facility), describes the robot arm that is used on the ISS and how it maneuvers the Space Station. The third topic of discussion is Science and Technology. Dr. Catherine Clark, using a balloon attached to a weight, drops the apparatus to the ground to demonstrate Microgravity. The bursting of the balloon is observed. Sherri Dunnette, Imaging Technologist, describes the various cameras that are used in space. The types of still cameras used are: 1) 35 mm, 2) medium format cameras, 3) large format cameras, 4) video cameras, and 5) the DV camera. Kumar Krishen, Chief Technologist ISS, explains inframetrics, infrared vision cameras and how they perform. The Short Arm Centrifuge is shown by Dr. Millard Reske, Senior Life Scientist, to subject astronauts to forces greater than 1-g. Reske is interested in the physiological effects of the eyes and the muscular system after their exposure to forces greater than 1-g.

Source record↗

Vision for Micro Technology Space Missions

It is exciting to contemplate the various space mission applications that Micro Electro Mechanical Systems (MEMS) technology could enable in the next 10-20 years. The primary objective of this chapter is to both stimulate ideas for MEMS technology infusion on future NASA space missions and to spur adoption of the MEMS technology in the minds of mission designers. This chapter is also intended to inform non-space oriented MEMS technologists, researchers and decision makers about the rich potential application set that future NASA Science and Exploration missions will provide. The motivation for this chapter is therefore to lead the reader down a path to identify and it is exciting to contemplate the various space mission applications that Micro Electro Mechanical Systems (MEMS) technology could enable in the next 10-20 years. The primary objective of this chapter is to both stimulate ideas for MEMS technology infusion on future NASA space missions and to spur adoption of the MEMS technology in the minds of mission designers. This chapter is also intended to inform non-space oriented MEMS technologists, researchers and decision makers about the rich potential application set that future NASA Science and Exploration missions will provide. The motivation for this chapter is therefore to lead the reader down a path to identify and consider potential long-term, perhaps disruptive or revolutionary, impacts that MEMS technology may have for future civilian space applications. A general discussion of the potential for MEMS in space applications is followed by a brief showcasing of a few selected examples of recent MEMS technology developments for future space missions. Using these recent developments as a point of departure, a vision is then presented of several areas where MEMS technology might eventually be exploited in future Science and Exploration mission applications. Lastly, as a stimulus for future research and development, this chapter summarizes a set of barriers to progress, design challenges and key issues that must be overcome in order for the community to move on, from the current nascent phase of developing and infusing MEMS technology into space missions, in order to achieve its full future potential.

Dennehy, Neil↗

Expected Characteristics of Global Wind Profile Measurements with a Scanning, Hybrid, Doppler Lidar System

Over 20 years of investigation by NASA and NOAA scientists and Doppler lidar technologists into a global wind profiling mission from earth orbit have led to the current favored concept of an instrument with both coherent- and direct-detection pulsed Doppler lidars (i.e., a hybrid Doppler lidar) and a stepstare beam scanning approach covering several azimuth angles with a fixed nadir angle. The nominal lidar wavelengths are 2 microns for coherent detection, and 0.355 microns for direct detection. The two agencies have also generated two sets of sophisticated wind measurement requirements for a space mission: science demonstration requirements and operational requirements. The requirements contain the necessary details to permit mission design and optimization by lidar technologists. Simulations have been developed that connect the science requirements to the wind measurement requirements, and that connect the wind measurement requirements to the Doppler lidar parameters. The simulations also permit trade studies within the multi-parameter space. These tools, combined with knowledge of the state of the Doppler lidar technology, have been used to conduct space instrument and mission design activities to validate the feasibility of the chosen mission and lidar parameters. Recently, the NRC Earth Science Decadal Survey recommended the wind mission to NASA as one of 15 recommended missions. A full description of the wind measurement product from these notional missions and the possible trades available are presented in this paper.

Kavaya, Michael J.↗