Engineering PapersSearch

SEARCH · Engineering Papers

Results for “TEB”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Long Term Stability Monitoring of Aqua MODIS Thermal Emissive Bands through Radiative Transfer Modeling

Moderate Resolution Imaging Spectroradiometer (MODIS) on Aqua has been in operation providing continuous global observations for science research and applications since 2002. The long-term stability of thermal emissive bands (TEBs) of Aqua MODIS was monitored through inter-comparisons with measurements by hyperspectral infrared sensors, such as AIRS on Aqua and IASI on MetOp satellite, or through long term vicarious monitoring over cold targets, such as Dome- C and deep convective clouds (DCC). In this paper, a radiative transfer modeling-based simulation model using Community Radiative Transfer Model (CRTM) is developed to perform the long-term monitoring of the stability of TEBs of Aqua MODIS. CRTM is a fast-radiative transfer model for calculations of radiances for satellite infrared radiometers and is able to output infrared radiance and brightness temperature at spectral bands of MODIS. Long term European Centre for Medium-Range Weather Forecasts (ECMWF) global atmospheric reanalysis data, such as temperature and humidity profiles, are used as inputs to the CRTM simulation. By confining the area of interest to be over low to middle latitude ocean, the long-term stabilities of selected Aqua MODIS TEBs are monitored through Observation–Background (O-B) brightness temperature (BT) bias between MODIS measurements and BT retrieval from CRTM simulation. The consistency and relative stability between Aqua MODIS and ECMWF reanalysis data for surface channels of MODIS are evaluated. In addition, the radiative transfer modeling with CRTM enables us to evaluate the impacts of long term variation of global CO2 distribution on the O-B BT biases for CO2 channels of Aqua MODIS through comparison of simulations with constant or long term variable CO2 as inputs. The O-B analysis with RTM show that Aqua MODIS surface channels are all radiometrically stable with yearly BT bias drift less than 0.004K/year for B20, B22, B23 and ~0.01K/year for B31 and B32. The CO2 absorption channels of Aqua MODIS, e.g. B33-B36, are stable with BT bias drift < 0.005K/year.

MODIS

Feasibility studies of the growth of 3-5 compounds of boron by MOCVD

Boron-arsenic and boron-phosphorus films have been grown on Si sapphire and silicon-on-sapphire (SOS) by pyrolyzing Group 3 alkyls of boron, i.e., trimethylborane (TMB) and triethylborane (TEB), in the presence of AsH3 and PH3, respectively, in an H2 atmosphere. No evidence for reaction between the alkyls and the hydrides on mixing at room temperature was found. However, the films were predominantly amorphous. The film growth rate was found to depend on the concentration of alkyl boron compound and was essentially constant when TEB and AsH3 were pyrolyzed over the temperature range 550 C to 900 C. The films were found to contain mainly carbon impurities (the amount varying with growth temperature), some oxygen, and were highly stressed and bowed on Si substrates, with some crazing evident in thin (2 micron) B-P and thick (5 micron) B-As films. The carbon level was generally higher in films grown using TEB as the boron source. Films grown from PH3 and TMB showed a higher carbon content than those grown from AsH3 and TMB. Based on their B/As and B/P ratios, films with nominal compositions B sub12-16 As2 and B sub1.1-1.3 P were grown using TMB as the boron source.

Manasevit, H. M.

The use of metalorganics in the preparation of semiconductor materials. VIII - Feasibility studies of the growth of Group III-Group V compounds of boron by MOCVD

The MOCVD growth of B-As and B-P films on Si, sapphire, and Si-on-sapphire substrates is described; in this process, trimethylborane (TMB) or triethylborane (TEB) is pyrolyzed in the presence of AsH3 or PH3 in an H2 atmosphere. The procedures employed are outlined, and the results are presented in graphs, tables, and micrographs. It is found that the growth rate of the primarily amorphous films is dependent on the TMB or TEB concentration but approximately constant for TEB and AsH3 at 550-900 C. The nominal compositions of films grown using TMB are given as B(12-16)As2 and B(1-1.3)P. Carbon impurities and significant stress, bowing, and crazing are observed in the films grown on Si substrates, with the highest carbon content in the films grown from TMB and PH3.

Manasevit, H. M.

Sensor On-orbit Calibration and Characterization Using Spacecraft Maneuvers

Spacecraft flight operations often require activities that involve different kinds of maneuvers for orbital adjustments (pitch, yaw, and roll). Different maneuvers, when properly planned and scheduled, can also be applied to support and/or to perform on-board sensor calibration and characterization. This paper uses MODIS (Moderate Resolution Imaging Spectroradiometer) as an example to illustrate applications of spacecraft maneuvers for Earth-observing sensors on-orbit calibration and characterization. MODIS is one of the key instruments for NASA's Earth Observing System (EOS) currently operated on-board the EOS Terra and Aqua spacecraft launched in December 1999 and May 2002, respectively. Since their launch, both Terra and Aqua spacecraft have made a number of maneuvers, specially the yaw and roll maneuvers, to support the MODIS on-orbit calibration and characterization. For both Terra and Aqua MODIS, near-monthly spacecraft roll maneuvers are executed for lunar observations. These maneuvers are carefully scheduled so that the lunar phase angles are nearly identical for each sensor's lunar observations. The lunar observations are used to track MODIS reflective solar bands (RSB) calibration stability and to inter-compare Terra and Aqua MODIS RSB calibration consistency. To date, two sets of yaw maneuvers (each consists of two series of 8 consecutive yaws) by the Terra spacecraft and one set by the Aqua spacecraft have been performed to validate MODIS solar diffuser (SD) bi-directional reflectance factor (BRF) and to derive SD screen transmission. Terra spacecraft pitch maneuvers, first made on March 26, 2003 and the second on April 14, 2003 (with the Moon in the spacecraft nadir view), have been applied to characterize MODIS thermal emissive bands (TEB) response versus scan angle (RVS). This is particularly important since the pre-launch TEB RSV measurements made by the sensor vendor were not successful. Terra MODIS TEB RVS obtained from pitch maneuvers have been used in the current LIB calibration algorithm. Lunq observations from pitch maneuvers also provided information to cross-calibrate MODIS with other sensors (MISR and ASTER) on the same platform. We will provide a summary of MODIS maneuver activities and their applications for MODIS calibration and characterization. The results and lessons learned discussed in this paper from MODIS maneuver activities will provide useful insights into future spacecraft and sensor operation.

Xiong, X.

MODIS On-orbit Calibration Uncertainty Assessment

MODIS has 20 reflective solar bands (RSB) and 16 thermal emissive bands (TEB). Compared to its heritage sensors, MODIS was developed with very stringent calibration uncertainty requirements. As a result, MODIS was designed and built with a set of on-board calibrators (OBC), which allow key sensor performance parameters and on-orbit calibration coefficients to be monitored and updated. In terms of its calibration traceability, MODIS RSB calibration is reflectance based using an on-board solar diffuser (SD) and the TEB calibration is radiance based using an on-board blackbody (BB). In addition to on-orbit calibration coefficients derived from its OBC, calibration parameters determined from sensor pre-launch calibration and characterization are used in both the RSB and TEB calibration and retrieval algorithms. This paper provides a brief description of MODIS calibration methodologies and an in-depth analysis of its on-orbit calibration uncertainties. Also discussed in this paper are uncertainty contributions from individual components and differences due to Terra and Aqua MODIS instrument characteristics and on-orbit performance.

Chiang, Vincent

MODIS Radiometric Calibration and Uncertainty Assessment

Since launch, Terra and Aqua MODIS have collected more than II and 9 years of datasets for comprehensive studies of the Earth's land, ocean, and atmospheric properties. MODIS observations are made in 36 spectral bands: 20 reflective solar bands (RSB) and 16 thermal emissive bands (TEB). Compared to its heritage sensors, MODIS was developed with very stringent calibration and uncertainty requirements. As a result, MODIS was designed and built with a set of state of the art on-board calibrators (OBC), which allow key sensor performance parameters and on-orbit calibration coefficients to be monitored and updated if necessary. In terms of its calibration traceability, MODIS RSB calibration is reflectance based using an on-board solar diffuser (SD) and the TEB calibration is radiance based using an on-board blackbody (BB). In addition to on-orbit calibration coefficients derived from its OBC, calibration parameters determined from sensor pre-launch calibration and characterization are used in both the RSB and TEB calibration and retrieval algorithms. This paper provides a brief description of MODIS calibration methodologies and discusses details of its on-orbit calibration uncertainties. It assesses uncertainty contributions from individual components and differences between Terra and Aqua MODIS due to their design characteristics and on-orbit periormance. Also discussed in this paper is the use of MODIS LIB uncertainty index CUI) product.

Xiong, Xiaoxiong

Thermo-Electron Ballistic Coolers or Heaters

Electronic heat-transfer devices of a proposed type would exploit some of the quantum-wire-like, pseudo-superconducting properties of single-wall carbon nanotubes or, optionally, room-temperature-superconducting polymers (RTSPs). The devices are denoted thermo-electron ballistic (TEB) coolers or heaters because one of the properties that they exploit is the totally or nearly ballistic (dissipation or scattering free) transport of electrons. This property is observed in RTSPs and carbon nanotubes that are free of material and geometric defects, except under conditions in which oscillatory electron motions become coupled with vibrations of the nanotubes. Another relevant property is the high number density of electrons passing through carbon nanotubes -- sufficient to sustain electron current densities as large as 100 MA/square cm. The combination of ballistic motion and large current density should make it possible for TEB devices to operate at low applied potentials while pumping heat at rates several orders of magnitude greater than those of thermoelectric devices. It may also enable them to operate with efficiency close to the Carnot limit. In addition, the proposed TEB devices are expected to operate over a wider temperature range

Choi, Sang H.

Assessment of MODIS Thermal Emissive Band On-Orbit Calibration

Sixteen Moderate Resolution Imaging Spectroradiometer thermal emissive bands (TEBs) cover the wavelength from 3.75 to 14.24 m. TEB calibration uses data collected from the detector responses to the onboard blackbody (BB) and space view. The BB was designed to operate either at a constant temperature for detector linear gain calibration or at temperatures varying from ambient ( 270 K) to 315 K for on-orbit characterization of nonlinear coefficients. In this paper, we assess TEB on-orbit calibration performance in two aspects: One is to review the calibration trending on the orbital, daily, and multiyear timescales, and the other is to analyze the on-orbit calibration radiance uncertainty and its impact on the calibration. The calibration trending confirms the detector response dependence on the instrument temperature. The temperature trending and prelaunch characterization provide the basis for determining the calibration radiance source temperature range and uncertainties. An analytical approach was used to assess the impacts of onboard radiance uncertainties. The BB emission uncertainty, resulting from the temperature measurement error and emissivity uncertainty, causes a calibration uncertainty up to 0.3%, a value decreasing with the band wavelength. The BB nonblackness effect is analyzed and found to be insignificant. For the band with the lowest BB emissivity, the nonblackness affects the calibration radiance by less than 0.08%. The cavity emission uncertainty and the scan-mirror emission uncertainty both cause a less than 0.1% calibration uncertainty. The analysis of the nonlinear calibration coefficient uncertainty shows that its effect on the low Earth-view brightness-temperature range varies by band and is generally insignificant.

Chang, Tiejun

Inter-Comparison of S-NPP VIIRS and Aqua MODIS Thermal Emissive Bands Using Hyperspectral Infrared Sounder Measurements as a Transfer Reference

This paper compares the calibration consistency of the spectrally-matched thermal emissive bands (TEB) between the Suomi National Polar-orbiting Partnership (S-NPP) Visible Infrared Imaging Radiometer Suite (VIIRS) and the Aqua Moderate Resolution Imaging Spectroradiometer (MODIS), using observations from their simultaneous nadir overpasses (SNO). Nearly-simultaneous hyperspectral measurements from the Aqua Atmospheric Infrared Sounder(AIRS) and the S-NPP Cross-track Infrared Sounder (CrIS) are used to account for existing spectral response differences between MODIS and VIIRS TEB. The comparison uses VIIRS Sensor Data Records (SDR) in MODIS five-minute granule format provided by the NASA Land Product and Evaluation and Test Element (PEATE) and Aqua MODIS Collection 6 Level 1 B (L1B) products. Each AIRS footprint of 13.5 km (or CrIS field of view of 14 km) is co-located with multiple MODIS (or VIIRS) pixels. The corresponding AIRS- and CrIS-simulated MODIS and VIIRS radiances are derived by convolutions based on sensor-dependent relative spectral response (RSR) functions. The VIIRS and MODIS TEB calibration consistency is evaluated and the two sensors agreed within 0.2 K in brightness temperature.Additional factors affecting the comparison such as geolocation and atmospheric water vapor content are also discussed in this paper.

Li, Yonghong

JPSS-1 VIIRS Pre-Launch Response Versus Scan Angle Testing and Performance

The Visible Infrared Imaging Radiometer Suite (VIIRS) instruments on-board both the Suomi National Polar-orbiting Partnership (S-NPP) and the first Joint Polar Satellite System (JPSS-1) spacecraft, with launch dates of October 2011 and December 2016 respectively, are cross-track scanners with an angular swath of +/-56.06 deg. A four-mirror Rotating Telescope Assembly (RTA) is used for scanning combined with a Half Angle Mirror (HAM) that directs light exiting from the RTA into the aft-optics. It has 14 Reflective Solar Bands (RSBs), seven Thermal Emissive Bands (TEBs) and a panchromatic Day Night Band (DNB). There are three internal calibration targets, the Solar Diffuser, the BlackBody and the Space View, that have fixed scan angles within the internal cavity of VIIRS. VIIRS has calibration requirements of 2% on RSB reflectance and as tight as 0.4% on TEB radiance that requires the sensor's gain change across the scan or Response Versus Scan angle (RVS) to be well quantified. A flow down of the top level calibration requirements put constraints on the characterization of the RVS to 0.2%-0.3% but there are no specified limitations on the magnitude of response change across scan. The RVS change across scan angle can vary significantly between bands with the RSBs having smaller changes of approximately 2% and some TEBs having approximately 10% variation. Within aband, the RVS has both detector and HAM side dependencies that vary across scan. Errors in the RVS characterization will contribute to image banding and striping artifacts if their magnitudes are above the noise level of the detectors. The RVS was characterized pre-launch for both S-NPP and JPSS-1 VIIRS and a comparison of the RVS curves between these two sensors will be discussed.

Moyer, David

Postlaunch Assessment of the Response Versus Scan Angle for the Thermal Emissive Bands of Visible Infrared Imaging Radiometer Suite On-Board the Suomi National Polar-Orbiting Partnership Satellite

The visible infrared imaging radiometer suite (VIIRS) is a key sensor carried on the Suomi national polar-orbiting partnership (S-NPP) satellite, which was launched in October 2011. It has several on-board calibration components, including a solar diffuser and a solar diffuser stability monitor for the reflective solar bands, a V-groove blackbody for the thermal emissive bands (TEB), and a space view port for background subtraction. These on-board calibrators are located at fixed scan angles. The VIIRS response versus scan angle (RVS) was characterized prelaunch in lab ambient conditions and is currently used to characterize the on-orbit response for all scan angles relative to the calibrator scan angle. Since the RVS is vitally important to the quality of calibrated radiance products, several independent studies were performed to analyze the prelaunch RVS measurement data. A spacecraft level pitch maneuver was scheduled during the first 3 months of intensive Cal/Val. The S-NPP pitch maneuver provided a rare opportunity for VIIRS to make observations of deep space over the entire range of Earth view scan angles, which can be used to characterize the TEB RVS. This study provides our analysis of the pitch maneuver data and assessment of the derived TEB RVS by comparison with prelaunch results. In addition, the stability of the RVS after the first 5 years of operation is examined using observed brightness temperatures (BT) over a clear ocean at various angles of incidence (AOI). To reduce the impact of variations in the BT measurements, the daily overpasses collected over the ocean are screened for cloud contamination, normalized to the results obtained at the blackbody AOI, and averaged each year.

Wu, Aisheng

Assessment of Terra MODIS Thermal Emissive Band Calibration Using Cold Targets and Measurements in Lunar Roll Events

Terra MODIS has provided continuous global observations for science research and applications for more than 18 years. The MODIS Thermal emissive bands (TEB) radiometric calibration uses a quadratic function for instrument response. The calibration coefficients are updated using the response of an on-board blackbody (BB) in quarterly warm-up and cool-down (WUCD) events. As instrument degradation and electronic crosstalk of long-wave infrared (LWIR) bands 27 to 30 developed substantial issues, accurate calibration is crucial for a high-quality L1B product. The on-board BB WUCD temperature ranges from 270 K to 315 K and the derived nonlinear response has a relatively large uncertainty for the offset, especially for these LWIR bands, which affects the measurements of low brightness temperature (BT) scenes. In this study, the TEB radiometric calibration impact on the L1B product is assessed using selected cold targets and the measurements during regular lunar rolls. The cold targets include Antarctic Dome Concordia (Dome-C) and deep convective clouds (DCC) for the calibration assessment, focusing on bands 27 to 30. Dome-C area is covered with uniformly-distributed permanent snow, and the atmospheric effect is small and relatively constant. Usually the DCC is treated as an invariant earth target to evaluate the reflective solar band calibration. The DCC can also be treated as a stable target to assess the performance of TEB calibration. During a scheduled lunar observation event with a spacecraft roll maneuver to view the moon through the space view port, the instrument cavity provides a stable reference for calibration assessment. The long-term trending of BT measurements and the relative difference between scan mirror sides and detectors are used for the assessment of the calibration consistency and stability. The comparison of L1B products over the selected targets before and after the calibration coefficients update can be used to assess the impact of a calibration look-up table (LUT) update. This assessment is beneficial for future calibration algorithm and LUT update procedure improvements for enhancing the L1B product quality.

Chang, Tiejun

Early Calibration and Performance Assessments of NOAA-20 VIIRS Thermal Emissive Bands

The Visible Infrared Imaging Radiometer Suite (VIIRS) sensor aboard the NOAA-20 (previously JPSS-1) spacecraft has successfully operated since its launch in November, 2017. Similar to the first VIIRS instrument on the Suomi-NPP spacecraft, data is collected in 22 spectral bands that are calibrated by a set of onboard calibrators. This paper provides an overview of the NOAA-20 VIIRS on-orbit operation and calibration, with a particular focus on the thermal emissive bands (TEBs). Results presented in this paper include the on-orbit changes in the TEB spectral band responses, detector noise characterization, and key calibration parameters, such as the non-linear coefficients derived from the blackbody warm-up cool-down cycle. Other issues, such as the early mission long-wave infrared (LWIR) response degradation due to icing on the dewar window, and their impact on sensor calibration are also discussed. Since launch, the VIIRS instrument temperature has been stable to within ± 0.8K and the cold focal plane temperatures are well controlled with variations less than 40 mK. With the exception of the early degradation observed in the LWIR bands, the TEB gains have been stable to within 0.04% (except I5 at 0.07%). Based on the current performance, VIIRS is expected to meet its calibration requirements throughout its design lifetime.

NEdT

Sensor Calibration Impacts on Dust Detection Based On MODIS And VIIRS Thermal Emissive Bands

Dust detection using remotely sensed measurements has been one of the challenging problems encountered by atmospheric scientists. MODerate Resolution Imaging Spectroradiometer (MODIS) on the Terra (T)and Aqua (A) platforms have been a versatile sensor for well over 21 and 18 years respectively and have been extremely useful in the retrieval of aerosol information over the entire globe. The MODIS radiances from the Level1B in general are expected to be within 5% accuracy in the reflective wavelengths and within 1% in the thermal emissive wavelengths. In this paper, we evaluate the sensitivity of previously developed dust detection technique based on thermal emissive wavelengths, which correspond to MODIS bands 20, 29, 31, and 32 respectively. The Thermal Emissive Dust Index (TEDI) performed very comparably to the traditional Aerosol Optical Thickness (AOT) retrievals by MODIS reflective channels. Since the MODIS Thermal Emissive Bands (TEB) are well calibrated on-orbit using a BlackBody (BB) source, the calibration of these long wave infrared bands is quite robust. As A-MODIS continues to perform well beyond its designed lifetime of 6 years, the instrument has undergone various levels of degradation during its mission time. As a consequence, it is imperative to check the impacts of calibration on the higher-level retrievals. In this paper, we rigorously analyze the sensitivity of TEDI due to the impact of calibration by the afore-mentioned TEB. The perturbation of the dominant (linear) calibration term demonstrated the following: first, there was a correlation in the sensitivity of the TEDI due to the uncertainty in the linear calibration term. Based on a perturbation in the linear calibration term for all aforementioned bands over a range of ± 5 % yielded the TEDI sensitivity to vary from approximately -3.2 % to about -3.6 %. When considering the uncertainty in each individual band significant changes were observed. The least change was observed for the perturbation in the calibration of band 20 with the TEDI sensitivity and the largest sensitivity in TEDI was observed in the perturbation of band 31 calibration. Thus, in the case of TEDI, noticeable sensitivity due to calibration uncertainty was observed in bands 29, 31, and 32, reiterating the importance of the TEB calibration in these bands. Also, the dust detection scheme based on A-MODIS was successfully transferred to the follow-on sensors such as Suomi (SNPP) and NOAA 20 (N20) VIIRS. The results presented in this paper would be extremely helpful in understanding impacts of calibration on the higher-level products for both current and future missions based on the MODIS heritage. Finally, the work also identifies the importance of radiometric fidelity in maintaining the accuracy of the dust detection. Results presented will show drastic improvement of the Saharan dust detection after the reduction of the electronic crosstalk in the 8.5 μm channel of T-MODIS.

Sriharsha Madhavan

Comparison of the MODIS and VIIRS Thermal Emissive Band Radiometric Calibration

Moderate Resolution Imaging Spectroradiometer (MODIS) and Visible Infrared Imaging Radiometer Suite (VIIRS) are major instruments for Earth science observations.Nearly 40 MODIS scientific products and a wide range of VIIRS environmental data records are produced using their global observations. The consistency of the MODIS and VIIRS calibrated data is important for the study of Earth science. This article assesses the calibration consistency of the Aqua MODIS and VIIRS thermal emissive band (TEB) data. To remove the impact of the mismatched relative spectral response (RSR) on the comparisons, the simultaneous nadir observation data from the cross-track infrared sounder (CrIS) and the infrared atmospheric sounding interferometer (IASI) are used as references in two different methods to independently verify the consistency. The comparisons of the MODIS and VIIRS TEB calibrated data show that the brightness temperature (BT) differences for comparable bands between MODIS and VIIRS are in general within 0.2 K for BT larger than 230 K. The differences of all comparable MODIS and VIIRS TEBs are consistent over time. MODIS measurements agree better with N20 VIIRS than with Suomi National Polar-orbiting Partnership (S-NPP) VIIRS. The S-NPP VIIRS measurements are higher than N20 VIIRS, within 0.1 Kfor long-wave infrared (LWIR) bands and 0.3 K for band M13.

Calibration

Crosstalk Effect in NOAA 20 VIIRS Thermal Emissive Bands

Crosstalk contamination in the Moderate Resolution Imaging Spectroradiometer (MODIS) thermal emissive bands (TEBs) has been a known issue since prelaunch, that has amplified on-orbit for some of bands. A linear algorithm has been developed and successfully applied to mitigate the crosstalk effect and restore the quality and accuracy of the MODIS L1B products. Significant crosstalk effect has also been found and characterized in TEBs of the Visible Infrared Imaging Radiometer Suite (VIIRS) on the Suomi National Polar-orbiting Partnership (SNPP). NOAA-20 VIIRS, a follow-on instrument to SNPP VIIRS, was launched on November 18, 2017. In this report, it is shown that there are nonnegligible crosstalk contaminations among the TEBs of NOAA-20 VIIRS as well. They are characterized using the scheduled lunar observations and compared with those in SNPP VIIRS.

Calibration

MODIS Thermal Emissive Bands Calibration Improvements for Collection 7

The MODIS thermal emissive bands (TEB) radiometric calibration uses a quadratic function for the instrument response, and the calibration coefficients look-up tables (LUTs) are updated using the response of an on-board blackbody (BB). After more than 21 and 19 years on-orbit, the TEB performances for Terra and Aqua MODIS have been generally stable. However, contamination from electronic crosstalk, a known issue since prelaunch, has affected the L1B image quality and measurement accuracy. In addition to the photovoltaic (PV) longwave infrared (LWIR) bands crosstalk correction included in Terra MODIS Collection 6.1 (C6.1), a crosstalk correction for select detectors in the Terra and Aqua mid-wave infrared (MWIR) and Aqua PV LWIR bands are applied in C7. The mission-long crosstalk coefficients for the selected detectors are derived and populated in the form of LUTs. The crosstalk correction is applied to both on-orbit calibration and the algorithm used to generate Earth-view L1B products. Among these detectors, the Aqua MODIS band 24 detector 1 crosstalk has the largest impact on image quality, with striping observed over cold scenes for both Terra and Aqua MODIS. The images of C7 L1B and C6.1 are compared to assess the impact of the correction. Additional assessments using Earthview measurements and inter-comparison also revealed the need for improvement of calibration stability and consistence for select bands. Additional improvements for long-term stability and mirror side consistence were developed using quasideep convective clouds (qDCC), Dome-C, ocean, desert, and inter-comparison with other instruments.

MODIS

LARCMACS: A TEX macro set for typesetting NASA reports

This LARCMACS user's manual describes the February 1988 version of LARCMACS, the TEX macro set used by the Technical Editing Branch (TEB) at NASA Langley Research Center. These macros were developed by the authors to facilitate the typesetting of NASA formal reports. They are also useful, however, for informal NASA reports and other technical documents such as meeting papers. LARCMACS are distributed by TEB for the convenience of the Langley TEX user community. LARCMACS contain macros for obtaining the standard double-column format for NASA reports, for typesetting tables in the ruled format traditional in NASA reports, and for typesetting difficult mathematical expressions. Each macro is described and numerous examples are included. Definitions of the LARCMACS macros are also included.

Woessner, Linda H.