Engineering PapersSearch

SEARCH · Engineering Papers

Results for “Synchronous generator”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Inertia estimation for power grids: A review of methods, challenges, and future prospects

The electric power grid is undergoing a significant transformation, shifting from traditional synchronous generators to inverter-based resources (IBRs) such as solar photovoltaics, wind turbines, and energy storage systems. This evolution leads to a reduction in system inertia, a critical attribute for maintaining frequency stability in response to disturbances. Consequently, the ability to monitor and estimate system inertia has become increasingly essential. This paper provides a comprehensive review of existing inertia estimation methodologies, analyzing them from multiple perspectives, including the types of data utilized, underlying estimation principles, operational modes, and system-wide applicability. A comparative summary table is included to distill commonalities and key characteristics across various studies. In addition, the paper examines practical implementations of inertia estimation across several major power systems worldwide, including the U.S. interconnections, the Nordic power system, and the U.K. grid. Key challenges are identified, particularly in estimating contributions from virtual inertia sources and load-induced inertia in increasingly converter-dominated networks. To address these emerging challenges, the paper proposes an integrated framework for real-time inertia estimation and monitoring. This framework encompasses critical components such as data acquisition, inertia estimation from both synchronous and non-synchronous sources, load-induced effects, optimization techniques, forecasting, and virtual inertia scheduling. Collectively, these elements enable dynamic, system-wide monitoring and adaptive control of grid inertia.

Inertia estimation

Experimentation in Exploring Photovoltaic Inverter Dynamics Under Different Irradiance Levels Through a Data-Driven Approach

As conventional direct connections of synchronous generators are being phased out, inverter-based resources (IBRs) with grid support functions are increasingly being integrated into power systems. This transition requires the development of accurate dynamic models for IBRs to predict how power systems will adapt to varying levels of IBRs penetration, establish grid code requirements, and ensure compliance. Here, this study introduces an active probing signal-based data-driven modeling technique to accurately derive the dynamics model of a smart photovoltaic inverter operating in Volt-Watt and Freq-Watt modes, in compliance with the IEEE 1547–2018 standard. The paper focuses on investigating how the dynamics of the PV inverter model respond to fluctuations in solar irradiance, utilizing real-time digital simulator experimentation. The experimental analysis demonstrates that the amplitude of dynamics fluctuates with changes in irradiance across both operational modes and confirms the active power’s dependence on irradiance levels. Furthermore, the nature of inverter dynamics varies distinctly between the different modes of activation. Critically, our findings indicate that dynamic models require DC-gain adjustments to accommodate contrasting irradiance levels, highlighting a negative gradient linear relationship between the DC-gain of each model and the irradiance.

14 SOLAR ENERGY

Microgrid Black Start Challenges: The Role of Grid-Forming Inverters

Grid-forming (GFM) inverters are becoming increasingly important for future power systems, particularly in establishing and restarting microgrids after blackouts. The use of GFM inverters enables microgrids to operate independently of utility power and provide key advantages over synchronous generators in black start scenarios, including rapid startup and stable voltage and frequency support for critical loads. However, inverter-driven black start introduces unique challenges and operational considerations. This article examines key challenges and solutions, emphasizing inverter design, control strategies, and microgrid system requirements. Drawing on analysis, simulation, and experimental results, this article highlights the central role of GFM inverters in ensuring reliable and resilient microgrid operations.

24 POWER TRANSMISSION AND DISTRIBUTION

Consensus-Based Control and Optimization of Power System Inertia

The integration of distributed energy resources (DERs), such as solar, wind, and energy storage systems, into power grids through inverter-based resources reduces power system inertia, leading to faster frequency dynamics and potential grid instability. To address this challenge, this paper proposes a distributed, consensus-based approach for the real-time control and optimization of inertia sources (synchronous generators and/or DERs) during system disturbances, enhancing both system stability and economic performance. The distributed control and optimization approach assumes each inertia source exchanges information solely with its neighbor ones, making it easily scalable to large power grid networks. The impacts of the communication connectivity among the inertia sources as well as their generation capacity limits on the distributed approach are investigated. We also demonstrate the approach’s robustness in scenarios involving communication time delays and packet losses, validating its effectiveness through numerical simulations on a 4-bus test system and a two-area 8-bus test system.

Power system inertia

Design and Analysis of an Integral MPPT Control Law for Wave Energy Conversion Systems

In this paper, we propose an integral-based maximum power point tracking (MPPT) algorithm for point absorber wave energy conversion (WEC) systems. A permanent magnet synchronous generator (PMSG) is coupled to the point absorber and its drive implements the proposed MPPT control. While the rotating frame of reference of the PMSG implements power control, the slower mechanical frequency of the incident waves are processed with an additional transformation that yields another set of dc dynamics. The computed dc power in the new reference frame, which is focused on slow wave dynamics, is input to the MPPT control law that tunes the emulated resistance of the machine drive to extract peak power from the wave absorber device. We derive a stability condition for the proposed controller and validate our control design on a simulated 10kW system.

wave energy, maximum power point tracking (MPPT),

A Cost-Effective Wave Energy Harvesting System with Maximum Power Point Tracking Capability

In this paper, we propose a low-cost bidirectional four-switch inverter that transfers three-phase energy between a permanent magnet synchronous generator (PMSG) driven by a wave energy collector and the power grid or a local ac load. To achieve high control performance, the machine-side inverter uses a high-gain observer for rotor position estimation and a Lyapunov-based approach for torque control. For the gridside inverter control, we estimate the filter capacitor voltage with a model reference adaptive system and control the dc-link voltage with a Lyapunov-based energy function. We also track the maximum power point from the sea waves with an integral control law that actively matches the generator impedance with that of the wave collection device. The proposed system supports both grid-following/forming modes. We validate our control design with simulation results on a 3-kW hardware setup.

wave energy, power systems integration, control de

Advanced Hierarchical Control Strategies in Multi-Building Microgrids

This paper proposes a hierarchical control system for a multi-building AC microgrid with improved inertia and immunity to communication delay. The primary level control is based on a Virtual Synchronous Generator (VSG) control and the secondary level control is enhanced with a SmithPredictor to improve the stability of the system in the presence of communication delay. Moreover, tertiary level control is proposed to effectively control active and reactive power sharing between the grid and the microgrid. Islanded and grid-connected modes of the microgrid system under study are illustrated with the help of simulation results in MATLAB Simulink environment.

Weldehawaryat, Lidya Mussie [graduate research ass

Fault Contribution of Grid-Following and Grid-Forming Inverters Considering Generic Inverter Controls and Ride-through Requirements

Gradual transformation of the synchronous generator (SG)-dominated power systems to inverter-based resource (IBR)-dominated power systems is bringing new challenges regarding power system protection. Increasing IBR’s penetration will reduce the reliability of protection coordination, originally developed for SG-dominated power systems, potentially leading to less accurate calculation or even mis-operation. Thus, new protection schemes compatible with IBR-dominated power systems should be established. Prior to establishing the protection schemes, research on the fault contribution of generic IBR models should be conducted considering interconnection requirements. This paper conducts fault current contribution analysis of generic grid-following (GFL) and grid-forming (GFM) inverters considering interconnection requirements using an electromagnetic transient (EMT) simulation tool. To do this, EMT-based generic GFL models have been developed with the ride-through requirements from IEEE-1547 standards. In addition, the major functions of the generic models are explained. Then, the fault current analysis was conducted using GFL and GFM inverters in a single-inverter-infinite-bus system and a modified IEEE 34-node system considering different grid, fault, inverter control parameters.

Kim, Jinho [BATTELLE (PACIFIC NW LAB)]

Impedance Emulation Control of Wave Energy Converters

Modeling and control of wave energy conversion (WEC) systems for maximum power extraction is challenging due to complex multiphysics that include fluids, mechanics, and machine drives. To uncover an intuitive model that clearly depicts WEC system operation, we utilize a force-current equivalent circuit framework which then enables us to design an impedance emulation control strategy. To provide context for our framework, we focus on a standard reference model-3 (RM3) point absorber device coupled to a permanent magnet synchronous generator. After the proposed extremum seeking controller is computed, we experimentally validate its performance on a platform that consists of two back-to-back connected inverters that emulate the WEC system.

wave energy conversion, impedance emulation, machi

A Participation Factor-Based Approach for Defining the EMT Model Boundary for Power System Simulations with Inverter-Based Resources

The increasing penetration of inverter-based resources (IBRs) introduces new challenges to power system simulations, particularly with the emergence of fast electromagnetic transient (EMT) dynamics and sub-synchronous oscillations (SSO) that require time-consuming EMT simulations. To reduce the time cost for simulating a large-scale power grid with IBRs, this paper proposes a novel participation factor-based approach for defining a critical zone for detailed EMT modeling and simulations, which includes the IBRs, synchronous generators, and the network components participating significantly in simulated contingencies. Both model-based and response-based methods are introduced for the estimation of participation factors (PFs). The case study on the 240-bus Western Electricity Coordinating Council (WECC) system demonstrates that the EMT zone determined by the proposed approach can effectively capture power system dynamics involving IBRs.

EMT simulation

Inverter Intensive Hybrid Power Plant Modeling with Small-Signal Stability Augmentation through Flexible Operation Mode Transition

Hybrid power plants (HPPs) prompt the penetration of inverter-based renewable energy sources (RES) in transmission systems; however, given their low-inertia nature, HPPs are dominated by power electronic inverters, so there are inevitable challenges in system stability when increasing numbers of HPPs are integrated into the modern power grids. To boost the penetration level of HPPs without jeopardizing system stability, it is desirable to equip them with operational characteristics (i.e., grid-forming capabilities) that are comparable to those of conventional power plants dominated by synchronous generators (SGs). In this paper, a holistic model of inverter intensive HPP is derived and a bi-level hierarchical control is developed to allow HPPs to flexibly switch among the designed operation modes (i.e., P-Q, P-V, and isochronous modes). Compared to SGs, which have limited controllability, the operation mode of each HPP could vary as requested. Such flexible mode transitions could be integrated into the secondary plant-level control and be leveraged as an additional control degree to further augment system stability. Further, the system small-signal stability margin is quantified with varying HPP operation modes. More importantly, modal analysis is thereby conducted to quantify the impacts of mode transition on the system oscillatory modes. The effectiveness of the proposed HPP bi-level hierarchical control is verified using extensive case studies based on the simplified real-world island power grid, and the results validate that the system small-signal stability margin can be enhanced with the additional degree of control flexibility enabled by HPP operation mode transition. The real-time hardware-in-the-loop (HIL) results are also provided to verify the proposed method.

grid-forming control

Distributed Inertia Management Under Communication Constraints

This paper presents a framework for distributed inertia management based on consensus algorithm. We propose a methodology to achieve optimal operation of inertia sources such as distributed energy resources (DERs) and synchronous generators in real time. Additionally, we analyze the algorithm under communication constraints and evaluate its robustness under scenarios involving communication time delays and packet losses. The proposed approach is validated via simulations on a 4-node system test feeder, demonstrating its effectiveness and resilience.

Yadav, Ajay [ORNL] (ORCID:000000016111881X)

Ensuring Solution Uniqueness in Three-Phase Power System State Estimation

This paper is concerned with the issue of potential non-unique solutions in three-phase state estimation. Theory of observability analysis for positive sequence power system state estimation is based on certain assumptions that avoid possibility of multiple solutions. Also, it is shown that observability of a positive sequence network remains independent of the network parameters or the operating state. When extending single-phase observability analysis directly to the three-phase case, this paper considers the possibility of converging to multiple solutions, i.e. solution non-uniqueness, even for cases where state estimator successfully converges. The study illustrates via numerical examples the likelihood of converging to entirely different solutions for certain network parameters. It also examines how the operating state, particularly under unbalanced loading, leads to solution non-uniqueness. The paper then describes an alternative approach to ensure a unique solution in three-phase state estimation. This method aims to accurately and uniquely estimate the state of any unbalanced three-phase system, irrespective of load imbalance, network configuration, existence of synchronous generators or transformers.

Power System State Estimation, Three-Phase, Distri

Voltage Probability Density Function Shaping Control Strategy Considering Grid Operational Uncertainties

It is well-known that power systems operation always affected by various uncertainties which make the bus voltage a random process that can be characterized by its probability density function (PDF) at any time instant. In this context, this paper presents a novel PDF-based voltage control framework for power systems. By modeling voltage as a stochastic process, we formulate a stochastic differential equationthat captures grid uncertainties. The associated Fokker-Planck-Kolmogorov equation is derived to describe the evolution of the voltage PDF, which enables the formulation of a PDF-shaping control strategy. To simplify the PDF control formulation, a B-spline neural network is introduced for real-time estimation and regulation of the voltage distribution. The proposed PDF control law updates voltage references for energy storage systems and synchronous generators using real-time PDF measurements and feedback signals. The proposed method is validated on a modified Kundur’s two-area system. Simulation results demonstrate that the controller can significantly improve the voltage stability under stochastic conditions, highlighting its effectiveness in modern inverter-rich grids.

Gui, Yonghao [ORNL] (ORCID:0000000250435534)

Testing and Analysis of Grid Forming Inverter Control for Achieving Resilient and Economic Operation of an Islanded Microgrid

This investigation examines the feasibility of operating a battery energy storage system (BESS) in parallel with synchronous generation by using grid forming (GFM) control in order to achieve frequency control objectives while mitigating increases to operating costs in the context of an islanded microgrid. The BESS GFM control system, which is based on conventional droop techniques, is modeled along with the overall microgrid using the Real Time Digital Simulator (RTDS) to allow for integration of genset controller hardware. A series of simulations are performed to test the voltage and frequency regulation capability of the BESS control system when the primary frequency regulating genset is tripped offline. The results of the simulations suggest that the GFM control scheme will successfully maintain frequency and voltage stability, which will enable operation without a back-up genset while not compromising the microgrid resiliency to contingencies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

A Twin Circuit Theory-Based Framework for Oscillation Event Analysis in Inverter-Dominated Power Systems With Case Study for Kaua‘i System

Here, this paper proposes a real-world oscillation event analysis framework for power systems that include inverter-based resources together with synchronous generators. Specifically, the proposed framework combines both measurement-and model-based techniques to readily identify potential oscillation sources, replay the oscillation event with numerical simulation, unveil the underlying oscillation mechanism, and suggest mitigation methods for a wide range of oscillation events. To strengthen the theoretical foundation of our analysis framework, this paper proposes a twin circuit theory that provides theoretical support for one key utilized but not well-proven measurement-based oscillation source identification method-Dissipating Energy Flow. Our twin circuit theory also shows that adopting well-tuned grid-forming inverters can be a potential mitigation method for oscillation events. Finally, the effectiveness of our proposed oscillation event analysis framework is demonstrated by addressing a real-world 18-20 Hz oscillation event in Kaua‘i's power system on November 21, 2021.

24 POWER TRANSMISSION AND DISTRIBUTION

Understanding Regional Inertia Dynamics in CAISO from Real Grid Disturbances

The shift from synchronous generators to inverter-based resources has caused power system inertia to be unevenly distributed across power grids. As a result, certain grid regions are more vulnerable to high rate-of-change of frequency (RoCoF) during disturbances. This paper presents a measurement-based framework for estimating grid inertia in CAISO (California Independent System Operator) region using real disturbance-driven frequency data from the Frequency Monitoring Network (FNET/GridEye). By analyzing confirmed disturbances from 2013 to 2024, we identify trends in regional inertia and frequency dynamics, highlighting their relationship with renewable generation and the evolving duck curve. Regional RoCoF values were up to six times higher than interconnection-wide values, coinciding with declining inertia. Recent recovery in inertia is attributed to the increased deployment of battery energy storage systems with synthetic inertia capabilities. These findings underscore the importance of regional inertia monitoring, strategic resource planning, and adaptive operational practices to ensure grid reliability amid growing renewable integration.

Dulal, Saurav [University of Tennessee, Knoxville

Analytical Models of Frequency and Voltage in Large-Scale All-Inverter Power Systems

Low-order frequency response models for power systems have a decades-long history in optimization and control problems such as unit commitment, economic dispatch, and wide-area control. With a few exceptions, these models are built upon the Newtonian mechanics of synchronous generators, assuming that the frequency dynamics across a system are approximately homogeneous, and assume the dynamics of nodal voltages for most operating conditions are negligible, and thus are not directly computed at all buses. As a result, the use of system frequency models results in the systematic underestimation of frequency minimum nadir and maximum RoCoF, and provides no insight into the reactive power-voltage dynamics. This paper proposes a low-order model of both frequency and voltage response in grid-forming inverter-dominated power systems. The proposed model accounts for spatial-temporal variations in frequency and voltage behavior across a system and as a result, demonstrates the heterogeneity of frequency response in future renewable power systems. Electromagnetic transient (EMT) simulations are used to validate the utility, accuracy, and computational efficiency of these models, setting the basis for them to serve as fast, scalable alternatives to EMT simulation, especially when dealing with very large-scale systems, for both planning and operational studies.

24 POWER TRANSMISSION AND DISTRIBUTION