Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Submillimeter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Arrays of Bolometers for Far-infrared and Submillimeter Astronomy

We describe 12 x 32 arrays of semiconducting cryogenic bolometers designed for use in far-infrared and submillimeter cameras. These 12 x 32 arrays are constructed from 1 x 32 monolithic pop-up detectors developed at NASA Goddard Space Flight Center. The pop-up technology allows the construction of large arrays with high filling factors that provide efficient use of space in the focal planes of far-infrared and submillimeter astronomical instruments. This directly leads to a significant decrease in observing time. The prototype array is currently operating in SHARC II, a facility instrument in use at the Caltech Submillimeter Observatory (CSO). The elements of this array employ a bismuth absorber coating and quarter wave backshort to optimize the bolometer absorption for a passband centered at 350 microns. However, this resonant structure also provides good bolometer performance at 450 and 850 microns, the two additional SHARC II passbands. A second array is to be installed in the High-resolution Airborne Widebandwidth Camera (HAWC), a far-infrared imaging camera for the Stratospheric Observatory for Infrared Astronomy (SOFIA). This array is currently in the final stage of construction, and its completion is expected in early 2004. HAWC is scheduled for commissioning in 2005. The HAWC array employs titanium-gold absorbers and is optimized for uniform absorption from 40 to 300 microns to accommodate all four of its far-infrared passbands. We describe the details of the array construction including the mechanical design and electrical characterization of the constituent linear arrays, comparing the SHARC II and HAWC cases. We also summarize the overall characteristics of the final two-dimensional arrays. Finally, we show examples of array performance in the form of images obtained with SHARC II.

Chuss, D. T.↗

Compact Receiver Front Ends for Submillimeter-Wave Applications

The current generation of submillimeter-wave instruments is relatively mass and power-hungry. The receiver front ends (RFEs) of a submillimeter instrument form the heart of the instrument, and any mass reduction achieved in this subsystem is propagated through the instrument. In the current implementation, the RFE consists of different blocks for the mixer and LO circuits. The motivation for this work is to reduce the mass of the RFE by integrating the mixer and LO circuits in one waveguide block. The mixer and its associated LO chips will all be packaged in a single waveguide package. This will reduce the mass of the RFE and also provide a number of other advantages. By bringing the mixer and LO circuits close together, losses in the waveguide will be reduced. Moreover, the compact nature of the block will allow for better thermal control of the block, which is important in order to reduce gain fluctuations. A single waveguide block with a 600- GHz RFE functionality (based on a subharmonically pumped Schottky diode pair) has been demonstrated. The block is about 3x3x3 cubic centimeters. The block combines the mixer and multiplier chip in a single package. 3D electromagnetic simulations were carried out to design the waveguide circuit around the mixer and multiplier chip. The circuit is optimized to provide maximum output power and maximum bandwidth. An integrated submillimeter front end featuring a 520-600-GHz sub-harmonic mixer and a 260-300-GHz frequency tripler in a single cavity was tested. Both devices used GaAs MMIC membrane planar Schottky diode technology. The sub-harmonic mixer/tripler circuit has been tested using conventional metal-machined blocks. Measurement results on the metal block give best DSB (double sideband) mixer noise temperature of 2,360 K and conversion losses of 7.7 dB at 520 GHz. The LO input power required to pump the integrated tripler/sub-harmonic mixer is between 30 and 50 mW.

Mehdi, Imran↗

Mu-Spec: A High Performance Compact Spectrometer for Submillimeter Astronomy

We describe the Mu-Spec, an extremely compact high performance spectrometer for the submillimeter and millimeter spectral ranges. We have designed a fully integrated submillimeter spectrometer based on superconducting microstrip technology and fabricated its critical elements. Using low loss transmission lines, we can produce a fully integrated high resolution submillimeter spectrometer on a single four inch Si wafer. A resolution of 500 can readily be achieved with standard fabrication tolerance, higher with phase trimming. All functions of the spectrometer are integrated - light is coupled to the microstrip circuit with a planar antenna, the spectra discrimination is achieved using a synthetic grating, orders are separated using a built-in planar filter, and the light is detected using photon counting Microwave Kinetic Inductance Detectors (MKID). We will discus the design principle of the instrument, describe its technical advantages, and report the progress on the development of the instrument.

Hsieh, Wen-Ting↗

Micro-Spec: A High Performance Compact Spectrometer for Submillimeter Astronomy

We describe the micro-Spec, an extremely compact high performance spectrometer for the submillimeter and millimeter spectral ranges. We have designed a fully integrated submillimeter spectrometer based on superconducting microstrip technology and fabricated its critical elements. Using low loss transmission lines, we can produce a fully integrated high resolution submillimeter spectrometer on a single four inch Si wafer. A resolution of 500 can readily be achieved with standard fabrication tolerance, higher with phase trimming. All functions of the spectrometer are integrated - light is coupled to the micro strip circuit with a planar antenna, the spectra discrimination is achieved using a synthetic grating, orders are separated using a built-in planar filter, and the light is detected using photon counting Microwave Kinetic Inductance Detectors (MKID). We will discus the design principle of the instrument, describe its technical advantages, and report the progress on the development of the instrument.

Hsieh, Wen-Ting↗

Observing Ice Phase Clouds and Precipitation with Millimeter- and Submillimeter-wave Radiometry during the IMPACTS field campaign: Algorithm Development for the Emerging Class of Microwave Radiometers

Millimeter- and submillimeter-wave (mmWave, submm) radiometers provide significant information content on atmospheric water in liquid, ice, and vapor phases. Recent sensors, such as the Global Precipitation Measurement (GPM) or the Temporal Experiment for Storms and Tropical Systems Technology – Demonstration (TEMPEST-D), use mmWave bands to improve estimation of ice-phase precipitation, and future missions, such as the Atmosphere Observing System (AOS), will extend to submm to provide additional information on thinner ice clouds, linking clouds and precipitation and therefore elucidating the links between weather, climate, and the water cycle. To support the expanded use of mmWave/submm radiometry and exploit the available information content on condensed water mass, we demonstrate ice and liquid water path retrievals for NASA Goddard Space Flight Center's airborne radiometers the Conical Scanning Millimeter-wave Imaging Radiometer (CoSMIR) and the Configurable Scanning Submillimeter-wave Instrument/Radiometer (CoSSIR, formerly the Compact Scanning Submillimeter Imaging Radiometer). The analysis is based on data collected during the Investigation of Microphysics and Precipitation for Atlantic Coast-Threatening Storms (IMPACTS) field campaign. A simulation study compares and contrasts retrievals for CoSMIR and CoSSIR, with CoSSIR demonstrating higher skill in ice retrievals, particularly for thin clouds, and the CoSMIR frequencies performing better for liquid. Additionally, we look at dual-polarized radiances observed by CoSMIR during the first two IMPACTS deployments to understand the polarization signatures induced by oriented hydrometeors. Results will be presented in the context of upcoming missions and sensors including AOS and the Ice Cloud Imager (ICI). We will describe the objectives for the expected first flight of the newly upgraded CoSSIR during the final IMPACTS deployment, and we will share novel science investigations we plan to undertake with CoSSIR's new capabilities. Popular Summary: Ice in clouds and falling snow is an important component of weather, climate, and water resources. To better use a new class of sensors that provide information on atmospheric ice, we developed an approach to measure ice clouds and falling snow using airborne data taken during the Investigation of Microphysics and Precipitation for Atlantic Coast-Threatening Storms (IMPACTS), a field campaign to study winter storms. We look at the results for two similar instruments to understand how those differences affect these measurements of clouds and snow, and we further investigate the information the sensors can provide on properties of the clouds and snow.

Ian S Adams↗

Demonstration of a 1-D Submillimeter-Wave Phased Array with MEMS Phase Shifters

At submillimeter-wave frequencies, due to the nonavailability of low-loss phase shifters, electronic antenna beam scanning is difficult to realize. Traditionally, power-hungry and bulky motors are used to mechanically scan the antenna beam. At lower-frequencies, phased array antennas are most commonly used where low-loss phase shifters are used with the array elements to accomplish beam steering. However, development of similar phased array antennas at submillimeter-waves has been challenging. Recently, we have developed a low-loss microelectromechanical systems (MEMS) based phased shifter in the 500-750 GHz band. In this work, we present a submillimeter-wave phased array antenna system with a cavity-backed double slot antenna architecture using the MEMS-based phase shifters. To demonstrate the concept, we developed two arrays: first one is a 8×1 linear antenna array with a fixed waveguide feeding network that achieved ±20◦ beam scanning, 18 dB directivity, and less than 1 dB scan loss over the design frequency of 500–570 GHz. The second one is a 4 × 1 linear antenna array with integrated MEMS-based phase shifters on each array element, achieving 15 dB directivity and capable of dynamic beam scanning over a range of ±9 ◦ . All the plots presented are simulated results since the parts are currently being fabricated. We hope to have access to our assembly and measurement facilities over the next few months and present measured performances at the conference.

Chattopadhyay, G.↗

Observing Ice Phase Clouds and Precipitation with Millimeter- and Submillimeter-wave Radiometry during the IMPACTS field campaign: Algorithm Development for the Emerging Class of Microwave Radiometers

Millimeter- and submillimeter-wave (mmWave, submm) radiometers provide significant information content on atmospheric water in liquid, ice, and vapor phases. Recent sensors, such as the Global Precipitation Measurement (GPM) or the Temporal Experiment for Storms and Tropical Systems Technology – Demonstration (TEMPEST-D), use mmWave bands to improve estimation of ice-phase precipitation, and future missions, such as the Atmosphere Observing System (AOS), will extend to submm to provide additional information on thinner ice clouds, linking clouds and precipitation and therefore elucidating the links between weather, climate, and the water cycle. To support the expanded use of mmWave/submm radiometry and exploit the available information content on condensed water mass, we demonstrate ice and liquid water path retrievals for NASA Goddard Space Flight Center's airborne radiometers the Conical Scanning Millimeter-wave Imaging Radiometer (CoSMIR) and the Configurable Scanning Submillimeter-wave Instrument/Radiometer (CoSSIR, formerly the Compact Scanning Submillimeter Imaging Radiometer). The analysis is based on data collected during the Investigation of Microphysics and Precipitation for Atlantic Coast-Threatening Storms (IMPACTS) field campaign. A simulation study compares and contrasts retrievals for CoSMIR and CoSSIR, with CoSSIR demonstrating higher skill in ice retrievals, particularly for thin clouds, and the CoSMIR frequencies performing better for liquid. Additionally, we look at dual-polarized radiances observed by CoSMIR during the first two IMPACTS deployments to understand the polarization signatures induced by oriented hydrometeors. Results will be presented in the context of upcoming missions and sensors including AOS and the Ice Cloud Imager (ICI). We will describe the objectives for the expected first flight of the newly upgraded CoSSIR during the final IMPACTS deployment, and we will share novel science investigations we plan to undertake with CoSSIR's new capabilities. Popular Summary: Ice in clouds and falling snow is an important component of weather, climate, and water resources. To better use a new class of sensors that provide information on atmospheric ice, we developed an approach to measure ice clouds and falling snow using airborne data taken during the Investigation of Microphysics and Precipitation for Atlantic Coast-Threatening Storms (IMPACTS), a field campaign to study winter storms. We look at the results for two similar instruments to understand how those differences affect these measurements of clouds and snow, and we further investigate the information the sensors can provide on properties of the clouds and snow.

Ian S Adams↗

On the modeling and optimization of Schottky varactor frequency multipliers at submillimeter wavelengths

Schottky varactor frequency multipliers are used to generate local oscillator power at millimeter and submillimeter wavelengths. The equivalent circuit of the Schottky varactor contains a junction capacitance, a junction conductance, a series resistance and a model for electron velocity saturation. A millimeter wavelengths the equivalent circuits is affected by the edge effects, which are due to the small-area circular anode. The correction factors due to the edge effect for the junction capacitance and for the series resistance are available in the literature. In this work the electron velocity saturation is modeled by limiting the velocity of the transition front between the depleted and undepleted layer. By using this model the maximum current of the diode is given by the actual area of the transition front between depleted and undepleted layers, and is therefore related to the capacitance correction factor. The new model has been tested by analyzing a two diode balanced doubler for 160 GHz presented earlier in the literature. The agreement between the theoretical results and the measurements is excellent. The new diode model is useful in optimization of varactors for high millimeter and submillimeter wave frequencies.

TRT-THEORETICAL↗

Submillimeter Source Needs for NASA Missions

Submillimeter source needs for the NASA astrophysics Submillimeter Intermediate Mission (SMIM) and the Earth Observing System Microwave Limb Sounder (EOS MLS) instrument are presented. Solid state local oscillators using planar devices are planned. State-of-the-art performance for these components is reviewed

Submillimeter↗

Submillimeter observations of planets

A new program of ground-based observations at submillimeter (about 400-micron) wavelengths has yielded observations of Mercury, Venus, Mars, Jupiter, and Saturn. We report here observations near planetary conjunctions, which have minimal corrections for atmospheric extinction: Mercury, 361 + or - 65 K; Venus, 231 + or - 35 K; and Saturn, 205 + or - 15 K (based upon the area of the planetary disk), using Jupiter (150 K) and Mars (220 K) as photometric standards. The Mercury observations show that the brightness temperature does not decrease at the submillimeter wavelengths, relative to observations at 3 mm; for Venus, however, the brightness temperature appears appreciably lower than at millimeter wavelengths. The results for Saturn indicate a strong and possibly optically thick contribution from the rings.

Hudson, H. S.↗

An optically pumped submillimeter wavelength regenerative amplifier

An optically pumped regenerative submillimeter laser amplifier is described. The amplifier uses a waveguide cavity resonator, and a Fabry-Perot interferometer composed of two dielectric-coated mirrors serves as input and output port for the submillimeter signal. Use of two mirrors enabled obtaining variations of up to 6:1 in transmission by varying the mirror spacing. When the 373-micron transition in CH3CN is excited in the oscillator by the CO2 laser pump beam, the received signal with amplification is about nine times the unamplified signal.

Galantowicz, T. A.↗

Design of a submillimeter laser Thomson scattering system for measurement of ion temperature in SUMMA

A thorough discussion of submillimeter laser Thomson scattering for the measurement of ion temperature in plasmas is presented. This technique is very promising and work is being actively pursued on the high power lasers and receivers necessary for its implementation. In this report we perform an overall system analysis of the Thomson scattering technique aimed to: (1) identify problem areas; (2) establish specifications for the main components of the apparatus; (3) study signal processing alternatives and identify the optimum signal handling procedure. Because of its importance for the successful implementation of this technique, we also review the work presently being carried out on the optically pumped submillimeter CH3F and D2O lasers.

Praddaude, H. C.↗

Submillimeter heterodyne detection of interstellar carbon monoxide at 434 micrometers

Laser heterodyne observations of submillimeter emissions from carbon monoxide in the Orion molecular cloud are reported. High frequency and spatial resolution observations were made at the NASA Infrared Telescope Facility on Mauna Kea by the use of an optically pumped laser local oscillator and quasi-optical Schottky diode mixer for heterodyne detection of the J = 6 - 5 rotational transition of CO at 434 microns. Spectral analysis of the 434-micron emission indicates that the emitting gas is optically thin and is at a temperature above 180 K. Results thus demonstrate the potential contributions of ground-based high-resolution submillimeter astronomy to the study of active regions in interstellar molecular clouds.

Fetterman, H. R.↗

An f/35 submillimeter photometer for the NASA infrared telescope facility

The design and performance of an f/35 submillimeter photometer are discussed. It is noted that the instrument provides for both broad- and medium-width passbands between 350 microns and 2 mm and for beam sizes between 28 arcsec and 100 arcsec FWHM. Under good atmospheric conditions, a broad-band 400 micron sensitivity of approximately 1.5 Jy is found to be obtainable in one hour. A description is given of the photometer's support housing, submillimeter radiometer, and electronics and data-handling system. In evaluating the performance, attention is given to sensitivity, beam profiles, and the effect of changes in the aperture on the signal.

Whitcomb, S. E.↗

High-resolution submillimeter-wave radiometry of supersonic flow

The recent development of a high-resolution submillimeter-wave heterodyne radiometer has made possible the first measurements of H2O molecule rotational line excitation temperatures and detailed profiles in supersonic flow. Absorption signals were measured across the flow for the 2/11/ from 2//02/ (752 GHz) para-H2O rotational transition against a hot background. These signals decrease downstream owing to the volume expansion of the gas away from the sonic nozle exit in the high-vacuum chamber. Radiative transfer calculations based on the large-velocity-gradient approximation and multilevel statistical equilibrium agree with these results and with the measured spectral line shapes. The data reveal nearly isentropic gas expansion and cooling. These studies have shown that submillimeter-wave heterodyne radiometry can be useful for remote sensing of supersonic flow with low mass flux, provided the signal transmission is through a dry or thin atmosphere.

Dionne, G. F.↗

Submillimeter astronomy and the problem of star formation

Sources that have traditionally been called 'protostars,' because they were strong emitters of infrared radiation embedded in dust clouds, are now recognized to be 'newly formed' stars instead. Recent developments in submillimeter astronomy should permit a redoubling of efforts to find bodies that are the actual predecessors of newly formed stars. This renewed search for true protostars will be aided by advances that have occurred in submillimeter spectroscopy; these will permit an analysis of the physical conditions and chemical constitution of cooler protostellar clouds, and may provide insight into circumstances favoring protostellar collapse.

Harwit, M.↗

Millimeter and submillimeter laboratory spectroscopy - Recent results of astrophysical interest

Recent laboratory spectroscopic results on the transient neutral species CCH, NH2, and NaH, the molecular ions HCO(+), N2H(+), and CO(+), and the light asymmetric internal rotor HOOH are reviewed. It is shown that the shorter millimeter and submillimeter spectral region offers a number of advantages, even in the laboratory. Attention is also given to the requirements for theoretical models capable of the accurate spectral predictions required for many astrophysical applications. The results presented here are seen as demonstrating that millimeter and submillimeter microwave spectroscopy provides a sensitive and flexible means of studying short-lived species in the laboratory. It is believed that, in combination with the appropriate theoretical approach, studies of this type are capable of providing accurate spectral maps over wide spectral regions for most species of astrophysical importance.

De Lucia, F. C.↗