Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Sub-Atmospheric”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

43 records · Page 3

Thermal Model of Ice Growth in Vacuum for Lunar Water Production

To support NASA’s goal of sustained lunar presence, the use of in-situ resource utilization will reduce launch weight and frequency of resupply missions. With the discovery of water in the permanently shadowed regions of the moon, the prospect of harvesting water has generated particular interest. A more fundamental understanding of water storage and capture in lunar conditions is necessary for effective and efficient water capture and transport. The present study derives a thermal model for ice height, heat flux, chamber pressure, and mass flow rate in sub-atmospheric pressures below the triple point. The thermal model compares ice layer height against the results of the experiment at two pressures (300 Pa and 500 Pa) and temperatures from -18°C to -3°C. The thermal model predicts the trends seen experimentally with an overall root mean square error of 0.1135 cm and coefficient of efficiency of 0.994, indicating the model predicts the experimental results. The thermal model can be utilized to examine the impacts of varying pressure, temperature, and cold plate area to determine the most effective ice growth conditions for efficient capture of water on the lunar surface. The thermal model will provide a useful tool for NASA in the design of the lunar ice tanker and shows the promise of effective capture water on the lunar surface.

Ice growth↗

Characterization Progress of an Absorption Laser Differential Interferometer

An absorption laser differential interferometer (A-LDI) system can be used to provide simultaneous, colinear measurements of flow properties (pressure, temperature, concentration, velocity) and flow fluctuations. Further characterization work on the absorption aspect of the system is provided in this paper, including characterization of the laser operating parameters, comparisons of two etalons of different free spectral range, and the further evaluation of a fixed-wavelength absorption measurement that can be used to obtain absorption and LDI measurements with the same sampling rate. A 0.4 GHz etalon was demonstrated to provide sufficient fringe peaks at low modulation depths to be used for the low-pressure testing characteristic of hypersonic wind tunnel facilities. The use of a 3 GHz etalon as a low-cost relative wavemeter was tested and validated. Data taken with the fixed-wavelength strategy in a sub-atmospheric test cell using 100% O2was successful and will allow absorption and LDI data to be acquired simultaneously, colinearly, and at the same sampling rate, yielding a truly simultaneous measurement of the flow density fluctuations and the flow mean density.

Joshua M Weisberger↗

Characterization Progress of an Absorption Laser Differential Interferometer

An absorption laser differential interferometer (A-LDI) system can be used to provide simultaneous, colinear measurements of flow properties (pressure, temperature, concentration, velocity) and flow fluctuations. Further characterization work on the absorption aspect of the system is provided in this paper, including characterization of the laser operating parameters, comparisons of two etalons of different free spectral range, and the further evaluation of a fixed-wavelength absorption measurement that can be used to obtain absorption and LDI measurements with the same sampling rate. A 0.4 GHz etalon was demonstrated to provide sufficient fringe peaks at low modulation depths to be used for the low-pressure testing characteristic of hypersonic wind tunnel facilities. The use of a 3 GHz etalon as a low-cost relative wavemeter was tested and validated. Data taken with the fixed-wavelength strategy in a sub-atmospheric test cell using 100% O 2 was successful and will allow absorption and LDI data to be acquired simultaneously, colinearly, and at the same sampling rate, yielding a truly simultaneous measurement of the flow density fluctuations and the flow mean density.

Joshua M. Weisberger↗

Evaluation of Long-Term Storage Stability and Operational Efficiency of Rapid Cycle Amine Adsorbents

With the recent incorporation of Mars Extravehicular Activity (EVA) into the 2025 NASA roadmap, Rapid Cycle Amine (RCA) technology advancement within the Exploration Extravehicular Mobility Unit (xEMU) applies to both the upcoming Lunar Artemis missions and future human exploration of Mars. The incorporation of commercial spacesuit vendors to service NASA’s crewed-space programs since 2021 has increased the demand for regenerable, RCA-based carbon dioxide (CO2) and humidity control adsorbents. The regenerable RCA subunit is the most advanced, long-term solution for CO2 removal and humidity control, enabling both lunar and Martian EVAs. The adsorbent selected for use within the RCA unit must exhibit sufficient storage stability and operational efficiency for prolonged missions. As XploSafe worked to simultaneously develop both a recirculating sub-atmospheric test rig and adsorbents for the RCA system within the xEMU, several novel adsorbents were evaluated for long-term storage stability in support of future extended-duration missions. The chosen materials were periodically evaluated by nuclear magnetic resonance (NMR) spectroscopy, thermal desorption-coupled with gas chromatography/mass spectrometry (TD-GC/MS), and CO2 adsorption to assess long-term storage efficacy across various environmental storage conditions. NMR spectroscopy was utilized by extracting the active CO2 adsorbing chemical from the solid support with deuterated solvent and comparing the spectra over time for degradation and change. The solid adsorbents were also analyzed via TD-GC/MS to reveal any potential off-gassing chemicals over time. Additionally, XploSafe’s breakthrough test rig was utilized to dose the solid adsorbents with a 585 BTU/h metabolic rate flow-equivalent CO2 stream and monitored for 0–99% CO2 breakthrough. The performance metrics from the breakthrough analysis were compared over the storage study duration for CO2 removal and humidity control. Xplo-SA9T was evaluated for 24 months, whereas two additional adsorbent variants, MMPA-Sorbent and LPEI-Sorbent, were each evaluated for 12 months.

John R Tidwell↗

Advancing 1D thermo-hydraulic tools for large cryogenic facilities

The Cryogenic Division at Fermilab develops large-scale cryogenic systems for particle accelerators and superconducting magnet test facilities. To support design and diagnostics, a Python-based code was created to calculate pressure drops in components such as valves and pipes. This paper presents recent enhancements to the code, including new heat transfer functions that improve the accuracy of thermal and hydraulic predictions. The first application models pressure and temperature changes in Proton Improvement Plant PIP-II relief pipes, aiding pipe sizing and protecting relief valves. The second example analyses heat load evolution in a pipe carrying sub-atmospheric helium, helping interpret temperature sensor data and understand gas return behavior to cold compressors. These improvements significantly expand the tool's capabilities, offering a practical resource for designing and troubleshooting cryogenic systems under dynamic thermal and flow conditions.

Beckwith, R. [Fermilab]↗

Fabrication of the HFVMTF Double-Bath Cryostat

The High Field Vertical Magnet Test Facility (HFVMTF) at Fermilab is designed to test superconducting magnets up to 20 tons and 1.3 meters in diameter. Central to the facility is a double-bath superfluid helium cryostat reaching 1.8 K at 1.2 bar. Integrated with a 15 T superconducting dipole from LBNL, HFVMTF supports HTS cable testing for fusion applications. This paper presents the design and fabrication of the cryostat, with a focus on two complex components: the 2 K heat exchanger and the lambda plate. The heat exchanger thermally links sub-atmospheric and pressurized helium baths. The 1.4-meter lambda plate provides thermal isolation and structural support for over 20 tons under 1.3 bar pressure differential. Finite Element Analysis validated the vessel's integrity under maximum load conditions.

Bruce, R. [Fermilab] (ORCID:0000000234200612)↗

OPEN2018 (continuation of GENSETS effort)

This project has demonstrated the key components and engineering principles to support a residential scale (1 to 2 kWe) recuperated Brayton cycle generator based upon a screw compressor and screw expander. This technical work is a continuation of the previously awarded ‘GENSETS’ program. The product goal has been to achieve a 40% fuel-to-electric LHV efficiency, an 80% overall CHP efficiency, emissions qualified to the California Air Resources Board standards, and at noise levels of 55 dB or less at 1 meter. Further, the product must operate with 8,000 hour service intervals and achieve a mean-time to overhaul of 90,000 hours. Lastly, and possibly most importantly, the product must meet demanding cost targets, exhibiting a factory cost well below $1,500/kWe. After extensive aerodynamic studies under the ‘GENSETS’ program, Brayton concluded that miniature turbomachinery could not achieve an efficiency consistent with the product’s system performance goal. Given compressor and turbine efficiency targets in the range of 78 to 81%, Brayton turned to the rotary screw machines. While the justification for a screw compressor over a conventional centrifugal compressor is well supported by industry experience, the high temperature expander represented the core technology advancement. To meet the extremely high efficiency goals, an all-ceramic rotary screw expander hot section was developed and has now been tested in the laboratory. This first-of-its-kind ceramic screw expander prototype was able to demonstrate aerodynamic efficiency in line with predictions. The test article was successfully run to full stress conditions so has also validated the mechanical design of such a unit. This has opened new avenues for the commercialization of high efficiency, small scale power generation. Interest in the technology has sparked several requests for alternate uses, an invitation to present at a screw machine conference, and continued interest from parties looking to develop a product in the spirit of the original ‘GENSETS’ goals.

42 ENGINEERING↗