Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Streamline Analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

COTS Data Analytics Software User Manual: Version 1.0

Large volumes of data are being collected by Sandia National Laboratories as part of an active commercial-off-the-shelf (COTS) part testing and surveillance program. This user manual documents Python-based COTS Data Analytics software that has been developed for standardizing, displaying, visualizing, and analyzing the resulting COTS part testing and surveillance data. It is the objective of these software tools to streamline the analysis of COTS testing and surveillance data and improve the efficiency with which test engineers and data analytics experts can pinpoint possible performance and reliability problems in COTS parts.

42 ENGINEERING↗

MO-F-16A-06: Implementation of a Radiation Exposure Monitoring System for Surveillance of Multi-Modality Radiation Dose Data

Purpose: We have implemented a commercially available Radiation Exposure Monitoring System (REMS) to enhance the processes of radiation dose data collection, analysis and alerting developed over the past decade at our sites of practice. REMS allows for consolidation of multiple radiation dose information sources and quicker alerting than previously developed processes. Methods: Thirty-nine x-ray producing imaging modalities were interfaced with the REMS: thirteen computed tomography scanners, sixteen angiography/interventional systems, nine digital radiography systems and one mammography system. A number of methodologies were used to provide dose data to the REMS: Modality Performed Procedure Step (MPPS) messages, DICOM Radiation Dose Structured Reports (RDSR), and DICOM header information. Once interfaced, the dosimetry information from each device underwent validation (first 15–20 exams) before release for viewing by end-users: physicians, medical physicists, technologists and administrators. Results: Before REMS, our diagnostic physics group pulled dosimetry data from seven disparate databases throughout the radiology, radiation oncology, cardiology, electrophysiology, anesthesiology/pain management and vascular surgery departments at two major medical centers and four associated outpatient clinics. With the REMS implementation, we now have one authoritative source of dose information for alerting, longitudinal analysis, dashboard/graphics generation and benchmarking. REMS provides immediate automatic dose alerts utilizing thresholds calculated through daily statistical analysis. This has streamlined our Closing the Loop process for estimated skin exposures in excess of our institutional specific substantial radiation dose level which relied on technologist notification of the diagnostic physics group and daily report from the radiology information system (RIS). REMS also automatically calculates the CT size-specific dose estimate (SSDE) as well as provides two-dimensional angulation dose maps for angiography/interventional procedures. Conclusion: REMS implementation has streamlined and consolidated the dosimetry data collection and analysis process at our institutions while eliminating manual entry error and providing immediate alerting and access to dosimetry data to both physicists and physicians. Brent Stewart has funded research through GE Healthcare.

60 APPLIED LIFE SCIENCES↗

ESTPiper – a web-based analysis pipeline for expressed sequence tags

Background: EST sequencing projects are increasing in scale and scope as the genome sequencing technologies migrate from core sequencing centers to individual research laboratories. Effectively, generating EST data is no longer a bottleneck for investigators. However, processing large amounts of EST data remains a non-trivial challenge for many. Web-based EST analysis tools are proving to be the most convenient option for biologists when performing their analysis, so these tools must continuously improve on their utility to keep in step with the growing needs of research communities. We have developed a web-based EST analysis pipeline called ESTPiper, which streamlines typical large-scale EST analysis components. Results: The intuitive web interface guides users through each step of base calling, data cleaning, assembly, genome alignment, annotation, analysis of gene ontology (GO), and microarray oligonucleotide probe design. Each step is modularized. Therefore, a user can execute them separately or together in batch mode. In addition, the user has control over the parameters used by the underlying programs. Extensive documentation of ESTPiper's functionality is embedded throughout the web site to facilitate understanding of the required input and interpretation of the computational results. The user can also download intermediate results and port files to separate programs for further analysis. In addition, our server provides a time-stamped description of the run history for reproducibility. The pipeline can also be installed locally, allowing researchers to modify ESTPiper to suit their own needs. Conclusion: ESTPiper streamlines the typical process of EST analysis. The pipeline was initially designed in part to support the Daphnia pulex cDNA sequencing project. A web server hosting ESTPiper is provided at http://estpiper.cgb.indiana.edu/ to now support projects of all size. The software is also freely available from the authors for local installations.

59 BASIC BIOLOGICAL SCIENCES↗

pathSQE : an automated workflow for single-crystal inelastic neutron scattering data processing and analysis

Inelastic neutron scattering (INS) experiments utilizing modern time-of-flight spectrometers enable the comprehensive mapping of the energy (E)- and momentum (Q)-resolved dynamical structure factor of single crystals, probing both the lattice and magnetic excitations. Yet, the large size and complexity of four-dimensional INS data are challenging current analysis workflows, often resulting in an underutilization of the measured information. To help address this issue, this paper introduces new software interfaced with the Mantid framework, pathSQE, designed to streamline the processing, analysis and interpretation of 4D single-crystal INS data. By automating key tasks such as 1D/2D slicing, symmetrization, Brillouin zone folding, data visualization, prioritization and filtering, and comparisons with simulations, pathSQE facilitates and accelerates INS data analysis workflows. Here, this paper outlines the features and implementation and provides several illustrations of the use of pathSQE on data collected on single crystals using direct-geometry time-of-flight spectrometers at the Spallation Neutron Source, including Ge, FeSi, MnO and SnS single-crystal measurements on the ARCS, HYSPEC and CNCS neutron spectrometers. Beyond streamlining post-experiment data processing, pathSQE establishes an automated and modular processing pipeline that could support future real-time experiment steering.

36 MATERIALS SCIENCE↗

SAXS Assistant: Automated SAXS analysis for structural discovery in biologics and polymeric nanoparticles

Small-angle x-ray scattering (SAXS) is a powerful technique for assessing macromolecular structure. High-throughput SAXS is limited by the time-consuming and, at times, subjective nature of SAXS data interpretation. Here, we present SAXS Assistant, a Python-based script that streamlines SAXS data analysis to extract features for machine learning (ML) and key structural parameters, including the Guinier radius of gyration (R g ), pair distance distribution function (PDDF)-derived R g , maximum particle dimension (D max ), and Kratky plots. The script builds upon BioXTAS RAW and validates reliability via Guinier/PDDF R g agreement, an important indicator of well-measured data sets. For assistance in D max estimation, a multilayer perceptron regressor was trained with 1940 data files from the Small Angle Scattering Biological Data Bank. The model achieved a test set performance R 2 = 0.90 and mean absolute error = 11.7 Å. Training exclusively with experimental data translates analyses from researchers, including experts in the field, to the ML model, which helps assess D max estimations from PDDF. Gaussian mixture model clustering was implemented to classify profiles into structural classes based on entries in the Small Angle Scattering Biological Data Bank. Users may therefore assess the similarity between experimental samples and known biomolecular shapes within the mapped repository entries. This probabilistic clustering aids in quantifying information from Kratky and generating shape-descriptive features. SAXS Assistant accelerates SAXS data analysis through enforced quality control, ML-ready outputs, and flags for low-confidence results. In addition to providing the ability to analyze large data sets at high throughput, this tool is versatile and may serve researchers in both biological and synthetic polymer research fields.

36 MATERIALS SCIENCE↗

Flexible Technoeconomic Analysis Tools for Evaluating Emerging Power Generation Technologies in Hourly Electricity Markets using IDAES and Pyomo

Conference presentation leveraging the recently developed “price-taker class”. We use the tool to develop and showcase workflows that enable rapid technology evaluation for power generation technologies. This work shows a reimplementation of previous results that were conducted outside the price-taker class framework, indicating this workflow is indeed streamlining emerging technology analysis.

Laky, Daniel↗

Machine Learning for Well Log Analysis in Uranium Mining

This project explores the use of Artificial Intelligence (AI) and Machine Learning (ML) techniques to automate well log analysis for uranium mining. Geophysical log data—spontaneous potential, resistivity, and gamma ray—were used to classify lithology, correlate well logs and identify roll front zonation patterns, which are critical for locating uranium ore bodies. Supervised ML algorithms such as eXtreme Gradient Boosting (XGBoost), Categorical Boosting (CatBoost), and Random Forest were trained to classify lithology with high accuracy. Gradient Boosting Machines (GBM), XGBoost, Random Forest, and Neural Networks were also used for role front zone identification. Moreover, a Fast Dynamic Time Warping (FastDTW) algorithm was employed for well log correlation. Additionally, sample lag was addressed using dynamic programming. Results demonstrate the potential of AI and ML to streamline well log analysis and enhance uranium exploration workflows.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Heat load measurements for the PIP-II pHB650 cryomodule

This study presents a brief overview of the 1st and 2nd phases and an in-depth analysis of the 3rd phase heat load testing performed on the pHB650 (prototype High Beta 650 MHz) cryomodule at PIP2IT (PIP-II Injector Test Facility), with a focus on both the results and the methodological advancements that have improved testing efficiency and accuracy. A key challenge identified in the testing campaign is the higher-than-expected heat loads observed in the first PIP-II (Proton Improvement Plan II) prototype cryomodules (pSSR1 and pHB650) tested at PIP2IT. Elevated heat loads are concerning given the fixed capacity of the PIP-II cryoplant that is currently being installed at Fermilab. However, understanding the sources of these elevated heat loads offers a critical opportunity to implement effective heat load mitigations on upcoming PIP-II cryomodules to stay within the available capacity of the PIP-II cryoplant. The study includes a summary of test results, descriptions of measurement procedures, and key observations on parameters directly and indirectly related to heat load measurements. Direct observations include measured heat loads and the effectiveness of JT heat exchanger under varying conditions, while indirect observation analyze factors such as the temperature distribution on the two-phase pipe and relief piping under varying conditions. Thermal acoustic oscillations (TAO) were identified during testing, which was mitigated by replacing the original G10 stem with a stainless steel stem equipped with wipers for the cryomodule cooldown valve. A major innovation during pHB650 Phase 3 testing was the development of an automated Python script to streamline data acquisition, analysis, and reporting of heat load results. This script automatically retrieved data from ACNET (Accelerator Control Network), performed heat load calculations, and generated detailed reports featuring plots and tables. This advancement significantly reduced manual labor and enhanced the thoroughness of data analysis compared to earlier campaigns. The heat load test reports were promptly uploaded to the electronic logbook shortly after each test, enabling rapid feedback and collaboration between the SRF and cryogenic teams. The heat load measurements included various components: HTTS (high-temperature thermal shield), LTTS (low-temperature thermal shield), 2K isothermal and non-isothermal heat loads. Results were recorded both within the cryomodule and between the bayonet can supply and return. Measurements were conducted under different operating conditions such as "standard", "linac", and "simulated dynamic". Additionally, HTTS and LTTS heat loads were calculated in real time, allowing for the tracking of thermal stability and identification of changes during testing, both in steady-state and transient conditions. The results of this testing campaign not only provide valuable insights into the performance of the pHB650 cryomodule but also highlight best practices and lessons learned that will inform future cryomodule testing at PIP2IT. These include adopting automated tools for data analysis, refining real-time measurement capabilities, and emphasizing detailed pre-test planning. The framework established in this campaign aims to set an improved standard for cryomodule testing and heat load reporting in future cryomodule test campaigns.

Porwisiak, D. [Fermilab; Wroclaw Tech. U.]↗

Developing an Interactive Data Visualization Tool to Assess the Impact of Decision Support on Clinical Operations

Due to mandates from recent legislation, clinical decision support (CDS) software is being adopted by radiology practices across the country. This software provides imaging study decision support for referring providers at the point of order entry. CDS systems produce a large volume of data, providing opportunities for research and quality improvement. In order to better visualize and analyze trends in this data, an interactive data visualization dashboard was created using a commercially available data visualization platform. Following the integration of a commercially available clinical decision support product into the electronic health record, a dashboard was created using a commercially available data visualization platform (Tableau, Seattle, WA). Data generated by the CDS were exported from the data warehouse, where they were stored, into the platform. This allowed for real-time visualization of the data generated by the decision support software. The creation of the dashboard allowed the output from the CDS platform to be more easily analyzed and facilitated hypothesis generation. Integrating data visualization tools into clinical decision support tools allows for easier data analysis and can streamline research and quality improvement efforts.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Explainable artificial intelligence relates perovskite luminescence images to current-voltage metrics

As the demand for low-cost, high-efficiency solar energy technologies grows, metal halide perovskite (MHP) solar cells have emerged as a promising candidate for next-generation photovoltaics due to their high power conversion efficiencies. However, their poor durability and issues with manufacturing consistency remain significant barriers to commercialization. In this work, we develop deep learning models to support materials characterization and provide insight into features and processes influencing performance. The models are trained using transfer learning of a pretrained model to predict relevant current-voltage (IV) metrics based on different combinations of input electroluminescence (EL) and photoluminescence (PL) images of MHP devices. We examine which image types are most informative in accurately predicting different IV metrics. Additionally, we use explainable artificial intelligence (XAI) techniques to provide insights into specific spatial features in the devices that drive differences in performance. We find that stabilized luminescence images (e.g. those collected after biasing the devices for at least 1 min) are better for predicting metrics of open-circuit voltage (by PL) and short-circuit current (by PL with EL), but that predicting fill factor and overall power output may use the time-evolution of EL images. Based on attribution masks generated by integrated gradients for each device performance metric, we further suggest different loss mechanisms associated with categories of large and small spatial defects. Overall, this case study highlights the potential applicability of XAI methodology for streamlining MHP device analysis and accelerating detailed understanding of the relationships between spatial defects and impacts on performance.

14 SOLAR ENERGY↗

The fast camera (Fastcam) imaging diagnostic systems on the DIII-D tokamak

Two camera systems are installed on the DIII-D tokamak at the toroidal positions of 90° (90° system) and 225° (225° system), respectively. The cameras have two types of relay optics, namely, a coherent optical fiber bundle and a periscope system. The periscope system provides absolute intensity calibration stability while sacrificing resolution (10 lp/mm), while the fiber system provides high resolution (16 lp/mm) while sacrificing calibration stability. The periscope is available only for the 90° system. The optics of the 225° system were designed for view stability, repeatability, and easy maintenance. The cameras are located inside optimized neutron, x ray and magnetic shielding in order to reduce electronics damage, reboots, and magnetic and neutron interference, increasing the overall system reliability. An automated filter wheel, providing remote filter change, allows for remote wavelength selection. A software suite automates camera acquisition and data storage, allowing for remote operation and reduced operator involvement. System metadata is used to streamline the data analysis workflow, particularly for intensity calibration. Here, the spatial calibration uses multiple observable wall features, resulting in a reconstruction accuracy ≤2 cm.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Improvement of three-field based safety analysis code, SPACE, through verification and validation

To verify and validate the state-of-the-art safety analysis code, SPACE, features of three field governing equations were arranged and the comparative analysis with both analytic solution and experimental benchmarks were performed. With the world wide streamline on the safety analysis, SPACE uses two-fluid, three-field governing equations which aim to implement multi-dimensional and multi-scaled analysis. Through the Verification and Validation (V and V), developing code based on the three-field governing equation have not only been confirmed but also improved. V and V activities on SPACE have been conducted as to interfacial drag model in vertical turbulent flow. The verification of the interfacial drag model was based on cell size sensitivity test for confirming feasible calculation range of cell size. Furthermore, through the validation with analytic solution, the modification of the interfacial drag model in vertical turbulent annulus flow was carried out and the nominated model was incorporated. Modified interfacial drag model, Asali's correlation, yields improved result than previous interfacial drag model. The validation with experimental benchmarks had also been performed on the nearly horizontal counter current limitation. To confirm the possibility of the further application of the CCFL model in case with horizontal pipe, validation with nearly horizontal pipe experiment was carried out. V and V activities of SPACE with analytic solution and experimental benchmarks allow us to confirm/identify the tailorability for safety analysis. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

The ADAQ framework: An integrated toolkit for data acquisition and analysis with real and simulated radiation detectors

Here, the ADAQ framework is a collection of software tools that is designed to streamline the acquisition and analysis of radiation detector data produced in modern digital data acquisition (DAQ) systems and in Monte Carlo detector simulations. The purpose of the framework is to maximize user scientific pro-ductivity by minimizing the effort and expertise required to fully utilize radiation detectors in a variety of scientific and engineering disciplines. By using a single set of tools to span the real and simulation domains, the framework eliminates redundancy and provides an integrated workflow for high-fidelity comparison between experimental and simulated detector performance. Built on the ROOT data analysis framework, the core of the ADAQ framework is a set of Cþþ and Python libraries that enable high-level control of digital DAQ systems and detector simulations with data stored into standardized binary ROOT files for further analysis. Two graphical user interface programs utilize the libraries to create powerful tools: ADAQAcquisition handles control and readout of real-world DAQ systems and ADAQAnalysis provides data analysis and visualization methods for experimental and simulated data. At present, the ADAQ framework supports digital DAQ hardware from CAEN S.p.A. and detector simulations performed in Geant4; however, the modular design will facilitate future extension to other manufacturers and simulation platforms.

detector simulation↗

Workbench Analysis Sequence Processor

The Workbench Analysis Sequence Processor (WASP) was developed to streamline lexing, parsing, access, validation, and analysis of ascii text files.

Lefebvre, RobertA.↗

Workbench Analysis Sequence Processor

The Workbench Analysis Sequence Processor (WASP) was developed to streamline lexing, parsing, access, validation, and analysis of ascii text files. The foundation of WASP resides on the parse tree data structure, where each node in the tree represents the syntax of the input document. Nodes can parent nodes with children. Nodes that have no children are known as terminal or leaf nodes , and they represent tokens (string, number, delimiter, etc.) in the text file. The fast lexical analyzer generator (flex - https://www.gnu.org/software/flex/) and GNU Bison parser generator (https://www.gnu.org/software/bison/) are extensively used for lexing and parsing.

97 MATHEMATICS AND COMPUTING↗

3D high-fidelity automated neutronics guided optimization of fusion blanket designs

The compact Fusion Pilot Plant (FPP) is defined in the recent National Academies of Sciences, Engineering, and Medicine report as the next step of fusion energy demonstration with a $50$ MWe peak net electricity production, $Q_e$ greater than $1$, and at least $3$ hours of continuous operation. This fusion pilot plant will be a test bed enabling materials, designs, and fuel management assessment, and it will represent an engineering challenge because of its high-fusion power and compact design targets. Previous reactor data is limited to experiments operating in different design space ranges. Therefore, design iterations and assessments should rely on high-fidelity first-principle theoretical and computational models. The high-fidelity integrated modeling of the plasma is a fundamental part of fusion energy research. However, the whole device modeling is often neglected, utilizing low-fidelity, system-level analysis. Recently, the need for high-fidelity multi-physics modeling was recognized, resulting in a selection of integrated tools. Further, autonomous design optimization requires a streamlined framework that perturbs the design point, reruns the analysis, and examines the outputs. However, high-fidelity analysis requires complex geometry specification that is difficult to perturb. This work presents the parametric CAD generation tool TRACER and a new neutronic workflow. TRACER allows the perturbation of the geometry representation, creating geometry files ready for further analysis. The streamlined neutronic workflow allows efficient and accurate calculations. The two new tools coupled together were used to perform a 3D high-fidelity multi-objective, multi-input optimization of an "ARC Class" compact tokamak design. The workflow was driven by an optimization driver for full automation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Enhanced AFCI Sampling, Analysis, and Safeguards Technology Review

The focus of this study includes the investigation of sampling technologies used in industry and their potential application to nuclear fuel processing. The goal is to identify innovative sampling methods using state of the art techniques that could evolve into the next generation sampling and analysis system for metallic elements. Sampling and analysis of nuclear fuel recycling plant processes is required both to monitor the operations and ensure Safeguards and Security goals are met. In addition, environmental regulations lead to additional samples and analysis to meet licensing requirements. The volume of samples taken by conventional means, can restrain productivity while results samples are analyzed, require process holding tanks that are sized to meet analytical issues rather than process issues (and that create a larger facility footprint), or, in some cases, simply overwhelm analytical laboratory capabilities. These issues only grow when process flowsheets propose new separations systems and new byproduct material for transmutation purposes. Novel means of streamlining both sampling and analysis are being evaluated to increase the efficiency while meeting all requirements for information. This report addresses just a part of the effort to develop and study novel methods by focusing on the sampling and analysis of aqueous samples for metallic elements. It presents an overview of the sampling requirements, including frequency, sensitivity, accuracy, and programmatic drivers, to demonstrate the magnitude of the task. The sampling and analysis system needed for metallic element measurements is then discussed, and novel options being applied to other industrial analytical needs are presented. Inductively coupled mass spectrometry instruments are the most versatile for metallic element analyses and are thus chosen as the focus for the study. Candidate novel means of process sampling, as well as modifications that are necessary to couple such instruments to introduce these samples, are discussed. A suggested path forward based on an automated microchip capillary based sampling system interfaced to the analysis spectrometer is presented. The ability to obtain micro liter volume samples coupled with remote automated means of sample tracking and transport to the instrument would greatly improve analytical efficiency while reducing both personnel exposure and radioactive waste. Application of this sampling technique to new types of mass spectrometers for selective elemental isotopic analysis could also provide significant improvements in safeguards and security analyses.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗