Operating Characteristics of Metal Hydride-Based Solar Energy Storage Systems

Thermochemical energy storage systems, based on a high-temperature metal hydride coupled with a low-temperature metal hydride, represent a valid option to store thermal energy for concentrating solar power plant applications. The operating characteristics are investigated for a tandem hydride bed energy storage system, using a transient lumped parameter model developed to identify the technical performance of the proposed system. The results show that, without operational control, the system undergoes a thermal ratcheting process, causing the metal hydride concentrations to accumulate hydrogen in the high-temperature bed over time, and deplete hydrogen in the low temperature. This unbalanced system is compared with a ’thermally balanced’ system, where the thermal ratcheting is mitigated by thermally balancing the overall system. The analysis indicates that thermally balanced systems stabilize after the first few cycles and remain so for long-term operation, demonstrating their potential for practical thermal energy storage system applications.

25 ENERGY STORAGE↗

Modeling the Performance of Large-Scale CO2 Storage Systems: A Comparison of Different Sensitivity Analysis Methods

NRAP is an initiative within DOE’s Office of Fossil Energy and is led by the National Energy Technology Laboratory (NETL). It is a multi-national-lab effort that leverages broad technical capabilities across the DOE complex to develop an integrated science base that can be applied to risk assessment for long-term storage of carbon dioxide (CO2). NRAP involves five DOE national laboratories: NETL-RUA, Lawrence Berkeley National Laboratory (LBNL), Lawrence Livermore National Laboratory (LLNL), Los Alamos National Laboratory (LANL), and Pacific Northwest National Laboratory (PNNL). The NETL-RUA is an applied research collaboration that combines NETL’s energy research expertise in the Office of Research and Development (ORD) with the broad capabilities of five nationally recognized, regional universities.

42 ENGINEERING↗

Performance evaluation of a dynamic wall integrated with active insulation and thermal energy storage systems

Thermal energy storage systems in buildings can store cooling/heating energy during non-peak load hours or when renewable energy sources are available for later use when demanded. Using the building envelope as a thermal battery can help to shave the peak load, reduce the burden in electric grids, and enhance the occupant's thermal comfort. Sensible energy storage on wall systems such as thermally activated building systems can provide an active thermal storage strategy. However, most of the stored energy is used through passive means directed by the thermal lag, which can impede the on-demand release of the stored energy. Integrating active insulation systems with building thermal storage systems can increase the flexibility of charging and discharging time and duration. In this study, a wall system equipped with an active insulation system and thermally activated storage system was designed, and its performance on active cooling energy contribution was studied. The performances of energy storage (charging), release (discharging) of the thermal energy storage energy, and the active insulation system were studied separately and together as an integrated system. Results showed that the thermal properties of the thermal energy storage core material and the pipe spacing of both embedded pipes in the thermal energy storage and hydronic pipes used in the active insulation system affected the wall performance the most out of all the tested wall system parameters. During discharging, the heat flux into the wall was as high as 81.92 W/m 2 . This active insulation system's dynamic R-value varied between less than 1ft 2 •°F•h/BTU (0.18 m 2 •K/W) to 98% of the equally thick foam insulation's R-value.

25 ENERGY STORAGE↗

Storage Systems and Input/Output: Organizing, Storing, and Accessing Data for Scientific Discovery. Report for the DOE ASCR Workshop on Storage Systems and I/O. [Summary Brief]

In September, 2018, the Department of Energy, Office of Science, Advanced Scientific Computing Research Program convened a workshop to identify key challenges and define research directions that will advance the field of storage systems and I/O over the next 5-7 years.The workshop concluded that addressing these combined challenges and opportunities requires tools and techniques that greatly extend traditional approaches and require new research directions. Key research opportunities were identified. This summary brief highlights three areas: The Impact of Storage and I/O, Research Opportunities, and, A new and productive Storage and I/O Environment. The full report from the workshop can be viewed at DOI: 10.2172/1491994.

97 MATHEMATICS AND COMPUTING↗

Storage Systems and Input/Output: Organizing, Storing, and Accessing Data for Scientific Discovery. Report for the DOE ASCR Workshop on Storage Systems and I/O. [Full Workshop Report]

In September, 2018, the Department of Energy, Office of Science, Advanced Scientific Computing Research Program convened a workshop to identify key challenges and define research directions that will advance the field of storage systems and I/O over the next 5–7 years. The workshop concluded that addressing these combined challenges and opportunities requires tools and techniques that greatly extend traditional approaches and require new research directions. Key research opportunities were identified.

97 MATHEMATICS AND COMPUTING↗

Computational analysis of a pipe flow distributor for a thermocline based thermal energy storage system

In this paper, the overall efficiency of a concentrating solar power (CSP) plant depends on the effectiveness of thermal energy storage (TES) system. A single tank TES system consists of a thermocline region which produces the temperature gradient between hot and cold storage fluid by density difference. Preservation of this thermocline region in the tank during charging and discharging cycles depends on the uniformity of the velocity profile at any horizontal plane. Our objective is to maximize the uniformity of the velocity distribution using a pipe-network distributor by varying the number of holes, distance between the holes, position of the holes and number of distributor pipes. For simplicity, we consider that the diameter of the inlet, main pipe, the distributor pipes and the height and the width of the tank are constant. We use Hitec ® molten salt as the storage medium and the commercial software Gambit 2.4.6 and Fluent 6.3 for the computational analysis. We analyze the standard deviation in the velocity field and compare the deviations at different positions of the tank height for different configurations. Since the distance of the holes from the inlet and their respective arrangements affects the flow distribution throughout the tank; we investigate the impacts of rearranging the holes position on flow distribution. Impact of the number of holes and distributor pipes are also analyzed. We analyze our findings to determine a configuration for the best case scenario.

14 SOLAR ENERGY↗

Fluid management system for a zero gravity cryogenic storage system

The fluid management system comprises a mixing/recirculation system including an external recirculation pump for receiving fluid from a zero gravity storage system and returning an output flow of the fluid to the storage system. An internal axial spray injection system is provided for receiving a portion of the output flow from the recirculation pump. The spray injection system thermally de-stratifies liquid and gaseous cryogenic fluid stored in the storage system.

Lak, Tibor I.↗

Performance Modeling of Network-Attached Storage Device Based Hierarchical Mass Storage Systems

Network attached storage devices improve I/O performance by separating control and data paths and eliminating host intervention during the data transfer phase. Devices are attached to both a high speed network for data transfer and to a slower network for control messages. Hierarchical mass storage systems use disks to cache the most recently used files and a combination of robotic and manually mounted tapes to store the bulk of the files in the file system. This paper shows how queuing network models can be used to assess the performance of hierarchical mass storage systems that use network attached storage devices as opposed to host attached storage devices. Simulation was used to validate the model. The analytic model presented here can be used, among other things, to evaluate the protocols involved in 1/0 over network attached devices.

Menasce, Daniel A.↗

Mathematical Modelling-Based Energy System Operation Strategy Considering Energy Storage Systems

Renewable energy resources are widely recognized as an alternative to environmentally harmful fossil fuels. More renewable energy technologies will need to penetrate into fossil fuel dominated energy systems to mitigate the globally witnessed climate changes and environmental pollutions. It is necessary to prepare for the potential problems with increased proportions of renewable energy in the energy system, to prevent higher costs and decreased reliability. Motivated by this need, this paper addresses the operation of an energy system with an energy storage system in the context of developing a decision-supporting framework.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Optimizing checkpoint data placement with guaranteed burst buffer endurance in large-scale hierarchical storage systems

Non-volatile devices, such as SSDs, will be an integral part of the deepening storage hierarchy on large-scale HPC systems. These devices can be on the compute nodes as part of a distributed burst buffer service or they can be external. Wherever they are located in the hierarchy, one critical design issue is the SSD endurance under the write-heavy workloads, such as the checkpoint I/O for scientific applications. For these environments, it is widely assumed that checkpoint operations can occur once every 60 min and for each checkpoint step as much as half of the system memory can be written out. Unfortunately, for large-scale HPC applications, the burst buffer SSDs can be worn out much more quickly given the extensive amount of data written at every checkpoint step. One possible solution is to control the amount of data written by reducing the checkpoint frequency. However, a direct effect caused by reduced checkpoint frequency is the increased vulnerability window of system failures and therefore potentially wasted computation time, especially for large-scale compute jobs.

Computer Science↗

A 150-kW 99% Efficient All-Silicon-Carbide Triple-Active-Bridge Converter for Solar-Plus-Storage Systems

Solar-plus-storage systems could effectively mitigate the uncertainties of the photovoltaic (PV) generation and improve system reliability by adding an integrated battery energy storage system. As a three-port bidirectional isolated dc–dc converter with soft-switching capability, the triple-active-bridge (TAB) converter inherently matches the requirements of the solar-plus-storage system. However, challenges still remain in the TAB converter design to further improve system efficiency. In this article, the detailed design, implementation, and demonstration for a silicon carbide (SiC) 150-kW TAB converter are presented. Starting from a brief review of the TAB converter, the modulation scheme, power characteristics, and soft-switching region are analyzed. Then, the detailed design of the H-bridge converter building block is given. Here, to improve the system efficiency, a comprehensive characterization of the SiC gate driver with various external gate resistances is performed to address tradeoffs between switching loss and voltage overshoot during transients, as well as the thermal performance of the H-bridge building block. In addition, the design and characterization of the 20-kHz three-port transformer are also given. Comprehensive experimental studies are conducted on a full-power prototype to verify the proposed design. With a measured 99.1% peak efficiency, the proposed TAB converter can fulfill the requirements for solar-plus-storage applications.

14 SOLAR ENERGY↗

High Density Digital Data Storage System

The High Density Digital Data Storage System was designed to provide a cost effective means for storing real-time data from the field-deployable digital acoustic measurement system. However, the high density data storage system is a standalone system that could provide a storage solution for many other real time data acquisition applications. The storage system has inputs for up to 20 channels of 16-bit digital data. The high density tape recorders presently being used in the storage system are capable of storing over 5 gigabytes of data at overall transfer rates of 500 kilobytes per second. However, through the use of data compression techniques the system storage capacity and transfer rate can be doubled. Two tape recorders have been incorporated into the storage system to produce a backup tape of data in real-time. An analog output is provided for each data channel as a means of monitoring the data as it is being recorded.

Wright, Kenneth D., II↗