Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Storage capacity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Soil carbon storage capacity of drylands under altered fire regimes

The determinants of fire-driven changes in soil organic carbon (SOC) across broad environmental gradients remains unclear, especially in global drylands. Here we combined datasets and field sampling of fire-manipulation experiments to evaluate where and why fire changes SOC and compared our statistical model to simulations from ecosystem models. Drier ecosystems experienced larger relative changes in SOC than humid ecosystems—in some cases exceeding losses from plant biomass pools—primarily explained by high fire-driven declines in tree biomass inputs in dry ecosystems. Many ecosystem models underestimated the SOC changes in drier ecosystems. Upscaling our statistical model predicted that soils in savannah–grassland regions may have gained 0.64 PgC due to net-declines in burned area over the past approximately two decades. Consequently, ongoing declines in fire frequencies have probably created an extensive carbon sink in the soils of global drylands that may have been underestimated by ecosystem models.

54 ENVIRONMENTAL SCIENCES↗

Energy performance analysis of smart wall system with switchable insulation and thermal storage capacity

The ever-increasing global energy demand and the issues caused by population growth and unsustainable energy resource usages have several environmental and economic impacts. The on-demand capability of dynamic wall systems with switchable insulation systems can contribute toward energy efficiency and reduced electric cost using "building-as-a-battery." In this paper, the performance of an exterior envelope system that employs a switchable insulation system is investigated. A COMSOL simulation was used to study the envelope performance under three switchable insulation locations in the wall system. The on and off switching cycle included insulating or conducting the exterior, interior, or both sides of the mass wall system. To validate the simulation work, an experimental test was conducted in climate chamber on a 4 × 8 in. wall system with identical wall components used in the COMSOL simulation. Results show a good agreement between the experiment and simulation results. The wall system with switchable insulation placed on the exterior side provided the highest interior inward heat flux when compared with the interior or split insulation. Also, an exterior switchable insulation system in addition to a thermal mass maintained a positive heat flow for more hours when the outdoor temperature was lower than the interior temperature.

Iffa, Emishaw↗

Assessing carbon storage capacity and saturation across six central US grasslands using data–model integration

Abstract. Future global changes will impact carbon (C) fluxes and pools in most terrestrial ecosystems and the feedback of terrestrial carbon cycling to atmospheric CO2. Determining the vulnerability of C in ecosystems to future environmental change is thus vital for targeted land management and policy. The C capacity of an ecosystem is a function of its C inputs (e.g., net primary productivity – NPP) and how long C remains in the system before being respired back to the atmosphere. The proportion of C capacity currently stored by an ecosystem (i.e., its C saturation) provides information about the potential for long-term C pools to be altered by environmental and land management regimes. We estimated C capacity, C saturation, NPP, and ecosystem C residence time in six US grasslands spanning temperature and precipitation gradients by integrating high temporal resolution C pool and flux data with a process-based C model. As expected, NPP across grasslands was strongly correlated with mean annual precipitation (MAP), yet C residence time was not related to MAP or mean annual temperature (MAT). We link soil temperature, soil moisture, and inherent C turnover rates (potentially due to microbial function and tissue quality) as determinants of carbon residence time. Overall, we found that intermediates between extremes in moisture and temperature had low C saturation, indicating that C in these grasslands may trend upwards and be buffered against global change impacts. Hot and dry grasslands had greatest C saturation due to both small C inputs through NPP and high C turnover rates during soil moisture conditions favorable for microbial activity. Additionally, leaching of soil C during monsoon events may lead to C loss. C saturation was also high in tallgrass prairie due to frequent fire that reduced inputs of aboveground plant material. Accordingly, we suggest that both hot, dry ecosystems and those frequently disturbed should be subject to careful land management and policy decisions to prevent losses of C stored in these systems.

58 GEOSCIENCES↗

High-Storage-Capacity Accelerometer System

Instrumentation system measures and records accelerations at frequencies from 0 to 100 Hz and magnitudes from 10 to the negative 5th power to 0.5 g. Developed to aid research on small accelerations in spacecraft in orbit. Also used on Earth: with modified acceleration sensors to monitor acceleration environments of sensitive products transported by airplanes, railroad trains, trucks, or ships.

Chase, Theodore L.↗

Thermal storage requirements for parabolic dish solar power plants

The cost effectiveness of a high temperature thermal storage system is investigated for a representative parabolic dish solar power plant. The plant supplies electrical power in accordance with a specific, seasonally varying demand profile. The solar power received by the plant is supplemented by power from fuel combustion. The cost of electricity generated by the solar power plant is calculated, using the cost of mass-producible subsystems (specifically, parabolic dishes, receivers, and power conversion units) now being designed for this type of solar plant. The trade-off between fuel and thermal storage is derived in terms of storage effectiveness, the cost of storage devices, and the cost of fuel. Thermal storage requirements, such as storage capacity, storage effectiveness, and storage cost are established based on the cost of fuel and the overall objective of minimizing the cost of the electricity produced by the system. As the cost of fuel increases at a rate faster than general inflation, thermal storage systems in the $40 to $70/kWthr range could become cost effective in the near future.

Wen, L.↗

Reservoir Thermal Energy Storage Benchmarking (Rev. 3)

A benchmarking analysis of RTES research funded by GTO through the Beyond Batteries projects was conducted against the ESGC to see where they fit within the identified ESGC Use Cases. The projects were found to advance knowledge in multiple ESGC use cases, either directly or in some cases, indirectly as enabling technologies. This analysis is helpful to understand where RTES and associated research fits into the larger discussion around energy storage technologies. Also, a retrospective analysis of the Beyond Batteries projects was conducted to evaluate what the projects learned and how the results can be applied to advance the value of RTES. Major results of each of the studies are summarized in Table 2. Additionally, a comparative metrics analysis for RTES was completed to understand where RTES lies within the energy storage industry. Metrics for evaluation of RTES and its comparison to other storage technologies were selected and ranges of their values compiled. The selected metrics – LCOE (levelized cost of energy), capital costs, roundtrip efficiency, energy storage capacity, and storage time – were chosen based on data availability and have a particularly strong influence on the potential deployment of a storage technology. Charts which compare the metrics are presented in section 4.3 and show ranges for each of the 10 selected technologies. However, due to a lack of domestic operational facilities, values for RTES and for portions of the remaining technologies are based on theoretical modeling and studies of best-case scenarios. LCOE estimates for RTES fall within the lower reaches of Figure 15, but nevertheless amount to 2 – 5 times the ESGC Roadmap goal for LCOE, for example in the Facilitating and Evolving Grid Use Case. Capital costs for RTES sit on the higher end (Figure 16) but are expected to decrease as new projects are developed and the technology is refined. The theoretical roundtrip efficiency reported for RTES varies from mid to high percentages (Figure 17) with efficiencies upwards of 93% in modeled scenarios in the Portland Basin (Bershaw et al.,2020). RTES is also expected to have the largest energy storage capacities and longest storage times, likely matched only by lower efficiency hydrogen storage. To better assess the role that RTES could play in energy storage we examined it’s potential in the U.S. The potential depends on many factors. Recently, many researchers have started looking at deep sedimentary basins, depleted oil and gas fields, and basalt formations as potential targets for RTES development. The United States Geological Survey (USGS) has analyzed various cities and shown substantial RTES potential in the cooling sector (Pepin et al., 2021). By modeling RTES in low-quality groundwater (e.g., brackish), it is shown to be favorable across the U.S. with particular suitability in the Illinois Basin, Coastal Plains, and Basin and Range regions. Seasonal RTES operations have also been modeled in the Portland Basin by those at the USGS and Portland State University to simulate an RTES system supplying heating loads needed for the Oregon Health and Science University. Simulations suggest that high conductive heat loss in the initial years exists but tends to decrease with increasing time and development of the resource due to self-insulating nature of the basalts (Burns et al., 2020). Other national laboratory efforts are taking a close look at many of the technical issues involved with RTES (McLing et al., 2019, McLing et al., 2022). These include difficulties in understanding geochemical, hydrogeological, mechanical, and microbiological changes at such elevated temperatures and operational scenarios. Major gaps in research are identified and suggested for future work. With this increased focus to understand how to make RTES successful in the U.S., this technology could be a potential solution to many of the nation’s energy storage problems. For the energy independence of this country, the DOE should prioritize de-risking this technology by making future investments in pilot-scale demonstrations to attract potential investors.

15 GEOTHERMAL ENERGY↗

Capacity loss on storage and possible capacity recovery for HST nickel-hydrogen cells

Negatively precharged nickel hydrogen cells will experience a useable capacity loss during extended open circuit storage periods. Some of the lost capacity can be recovered through cycling. Capacity recovery through cycling can be enhanced by cycling at high depths of discharge (DOD). The most timely procedure for recovering the faded capacity is to charge the cell fully and allow the cell to sit open-circuit at room temperature. This procedure seems to be effective in part because of the enlarged structure of the active materials. The compounds that formed during storage at the low electrode potentials can more easily dissolve and redistribute. All of the original capacity cannot be recovered because the lattice structure of the active material is irreversibly altered during storage. The recommendation is to use positively precharged cells activated with 26 percent KOH if possible. In aerospace applications, the benefits of negative precharge are offset by the possibility of delays and storage periods.

Lowery, John E.↗

Capacity retention in hydrogen storage alloys

Results of our examination of the properties of several candidate materials for hydrogen storage electrodes and their relation to the decrease in H-storage capacity upon open-circuit storage over time are reported. In some of the alloy samples examined to date, only about 10 percent of the hydrogen capacity was lost upon storage for 20 days, while in others, this number was as high as 30 percent for the same period of time. This loss in capacity is attributed to two separate mechanisms: (1) hydrogen desorbed from the electrode due to pressure differences between the cell and the electrode sample; and (2) chemical and/or electrochemical degradation of the alloy electrode upon exposure to the cell environment. The former process is a direct consequence of the equilibrium dissociation pressure of the hydride alloy phase and the partial pressure of hydrogen in the hydride phase in equilibrium with that in the electrolyte environment, while the latter is related to the stability of the alloy phase in the cell environment. Comparison of the equilibrium gas-phase dissociation pressures of these alloys indicate that reversible loss of hydrogen capacity is higher in alloys with P(eqm) greater than 1 atm than in those with P(eqm) less than 1 atm.

Anani, A.↗

Identifying geologic characteristics and operational decisions to meet global carbon sequestration goals

Geologic carbon sequestration is the process of injecting and storing CO 2 in subsurface reservoirs and is an essential technology for global environmental security (e.g., climate change mitigation) and economic security (e.g., CO 2 tax credits). To meet energy, economic, and environmental goals, society will have to identify vast volumes of high-capacity, low-cost, and viable storage reservoirs for sequestering CO 2 . In turn, this requires understanding how major geologic characteristics (such as reservoir depth, thickness, permeability, porosity, and temperature) and design and operational decisions (such as injection well spacing) impact CO 2 injection rates, storage capacity, and economics. Although many numerical simulation tools exist, they cannot repeat the required thousands or millions of simulations to identify ideal reservoir properties and the sensitivity and interaction between geologic parameters and operational decisions. Here, we use SCO 2 T—a fast-running, reduced-order modeling framework—to explore the sensitivity of major geologic parameters and operational decisions to engineering (CO 2 injection rates, plume dimensions, and storage capacities and effectiveness) and costs. Our results show, for the first time, benefits and impacts such as allowing CO 2 plumes to overlap, how different well spacing patterns affect CO 2 sequestration, the effects on costs of including brine treatment and disposal, and the effect of restricting injection rates to 1 MtCO 2 per y based on well limitations. We reveal multiple novel and unintuitive findings including: (i) deeper reservoirs have reduced carbon sequestration costs until injection rates reach 1 MtCO 2 per y, at which point deeper reservoirs become more expensive, (ii) thicker formations allow for increased injection rates and storage capacity, but thickness barely impacts plume areas, (iii) higher geothermal gradients result in reduced sequestration costs, unless brine treatment/disposal costs are included, at which point reservoirs having lower geothermal gradients are more economical because they produce less brine for each unit of injected CO 2 , and (iv) allowing plumes to overlap has a significantly positive impact of increasing storage capacities but has only a small influence on reducing sequestration costs. Altogether, our results illustrate new scientific conclusions to help identify suitable sites to inject and store CO 2 , to help understand the complex interaction between geology and resulting costs, and to help support the pursuit of meeting global sequestration targets.

58 GEOSCIENCES↗

Programming Abstractions for Managing Workflows on Tiered Storage Systems

Scientific workflows in High Performance Computing (HPC) environments are processing large amounts of data. The storage hierarchy on HPC systems is getting deeper, driven by new technologies (NVRAMs, SSDs, etc.) There is a need for new programming abstractions that allow users to seamlessly manage data at the workflow level on multi-tiered storage systems, and provide optimal workflow performance and use of storage resources. In previous work, we introduced a software architecture Managing Data on Tiered Storage for Scientific Workflows (MaDaTS) that used a Virtual Data Space (VDS) abstraction to hide the complexities of the underlying storage system while allowing users to control data management strategies. In this article, we detail the data-centric programming abstractions that allow users to manage a workflow around its data on the storage layer. The programming abstractions simplify data management for scientific workflows on multi-tiered storage systems, without affecting workflow performance or storage capacity. We measure the overheads and effectiveness introduced by the programming abstractions of MaDaTS. Our results show that these abstractions can optimally use the storage capacity in lesser capacity storage tiers, and simplify data management without adding any performance overheads.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Technology Assessment of High Capacity Data Storage Systems: Can We Avoid a Data Survivability Crisis?

This technology assessment of long-term high capacity data storage systems identifies an emerging crisis of severe proportions related to preserving important historical data in science, healthcare, manufacturing, finance and other fields. For the last 50 years, the information revolution, which has engulfed all major institutions of modem society, centered itself on data-their collection, storage, retrieval, transmission, analysis and presentation. The transformation of long term historical data records into information concepts, according to Drucker, is the next stage in this revolution towards building the new information based scientific and business foundations. For this to occur, data survivability, reliability and evolvability of long term storage media and systems pose formidable technological challenges. Unlike the Y2K problem, where the clock is ticking and a crisis is set to go off at a specific time, large capacity data storage repositories face a crisis similar to the social security system in that the seriousness of the problem emerges after a decade or two. The essence of the storage crisis is as follows: since it could take a decade to migrate a peta-byte of data to a new media for preservation, and the life expectancy of the storage media itself is only a decade, then it may not be possible to complete the transfer before an irrecoverable data loss occurs. Over the last two decades, a number of anecdotal crises have occurred where vital scientific and business data were lost or would have been lost if not for major expenditures of resources and funds to save this data, much like what is happening today to solve the Y2K problem. A pr-ime example was the joint NASA/NSF/NOAA effort to rescue eight years worth of TOVS/AVHRR data from an obsolete system, which otherwise would have not resulted in the valuable 20-year long satellite record of global warming. Current storage systems solutions to long-term data survivability rest on scalable architectures having parallel paths for data migration.

Halem, M.↗

The design of a petabyte archive and distribution system for the NASA ECS project

The NASA EOS Data and Information System (EOSDIS) Core System (ECS) will contain one of the largest data management systems ever built - the ECS Science and Data Processing System (SDPS). SDPS is designed to support long term Global Change Research by acquiring, producing, and storing earth science data, and by providing efficient means for accessing and manipulating that data. The first two releases of SDPS, Release A and Release B, will be operational in 1997 and 1998, respectively. Release B will be deployed at eight Distributed Active Archiving Centers (DAAC's). Individual DAAC's will archive different collections of earth science data, and will vary in archive capacity. The storage and management of these data collections is the responsibility of the SDPS Data Server subsystem. It is anticipated that by the year 2001, the Data Server subsystem at the Goddard DAAC must support a near-line data storage capacity of one petabyte. The development of SDPS is a system integration effort in which COTS products will be used in favor of custom components in very possible way. Some software and hardware capabilities required to meet ECS data volume and storage management requirements beyond 1999 are not yet supported by available COTS products. The ECS project will not undertake major custom development efforts to provide these capabilities. Instead, SDPS and its Data Server subsystem are designed to support initial implementations with current products, and provide an evolutionary framework that facilitates the introduction of advanced COTS products as they become available. This paper provides a high-level description of the Data Server subsystem design from a COTS integration standpoint, and discussed some of the major issues driving the design. The paper focuses on features of the design that will make the system scalable and adaptable to changing technologies.

Caulk, Parris M.↗

Cyclic moisture reactivation of calcium sorbents for long duration thermochemical energy storage

The transition to a flexible and reliable energy infrastructure, using electro-thermal energy generation technologies such as geothermal, concentrated solar power, and nuclear, usually demands simultaneous advancement of thermal energy storage (TES) to support on-demand electricity generation and industrial applications while mitigating the inherent intermittency of renewable energy sources and power outages from direct energy generation. Among TES technologies, thermochemical energy storage (TCES) based on calcium looping emerges as a compelling high-power energy storage candidate due to its high reaction enthalpy, compatibility with elevated operating temperatures, and abundance of low-cost materials. However, the long-term durability of calcium-based sorbents for TCES is hindered by surface sintering and particle aggregation, leading to performance degradation over repeated thermal cycles. This study explores a moisture hydration-based strategy to regenerate a degraded calcium sorbent and mitigate performance degradation for long duration TCES. The addition of moisture transforms calcium oxide into calcium hydroxide and produces intercalation water layers, associated with a regenerated surface area and reduced calcium oxide crystallite size. Both these effects are beneficial in restoring the sorbents' reactivity for carbonization. Additionally, an optimized hydration-assisted reactivation protocol balances the recovered energy storage capacity with heating penalty required for moisture removal from hydrated samples, resulting in an enhanced energy storage capacity up to 176% compared to benchmark sorbents that undergo cycling without reactivation after 60 cycles. In conclusion, these results highlight the potential of hydration-assisted reactivation to enhance the long-term performance of TCES, providing an effective pathway to advancing electro-thermal storage technologies.

36 MATERIALS SCIENCE↗

Energy Storage Market Transformation Through Stored Energy Targets

Aggressive energy decarbonization targets will require the rapid deployment of renewable energy in the U.S. in coming years. As the amount of variable generation on the grid grows, there will be an increasing need for long-duration energy storage (LDES) technologies to maintain grid reliability. Meeting that need will require a suite of technology alternatives with different capabilities. Many of these alternatives, however, are in a nascent state and face significant commercialization challenges. In the last decade, 10 U.S. states have enacted energy storage mandates as a vehicle for market transformation to accommodate energy storage. Those mandates, however, fail to send appropriate investment signals for LDES technologies because they are based on energy storage capacity and treat all technologies the same, regardless of duration. This paper explores the idea of replacing capacity-based storage procurement targets with stored energy targets, which would be technology-neutral policies designed to enable the market transformation necessary to support a competitive LDES industry.

Twitchell, Jeremy B.↗

NFD Methodology Report

The NetFlow Dynamics (NFD) model was developed for estimating the availability of a commodity supplied by a national- or regional-scale infrastructure following unexpected disruption of one or more of its components. The large scope of the disruptions of interest produce changes in availability lasting days to weeks. Consequently, the model does not resolve daily variations in system state and does not include the long-term processes that cause infrastructures to evolve as assets are added and removed according to owners ’planning decisions. NFD simulates fluid flow, including petroleum and other incompressible fluids, as well as natural gas and other compressible fluids, through pipeline networks characterized by limits on transmission capacity and storage. It was designed to enable efficient exploration of possible transmission system responses to large-scale disruptions lasting for days or longer. The model formulation reflects constraints on transmission and storage capacity imposed by the physical system assets. Those capacity limits are input parameters and are not derived from more basic system properties such as pipeline diameters and compressor power. A system’s response to a large disruption is controlled by operational decisions as well as damage to physical assets. The NFD model formulation allows users to efficiently consider alternative scenarios about the way remaining capacity might be used so that the analysis result appropriately reflects uncertainties about operator response.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Development of a Modular, Crushed-Rock Thermal Energy Storage Pilot Design

The goal of this project, primarily funded by the U.S. Department of Energy, is to design a next-step pilot to advance near-term energy storage integrated with a fossil plant to provide a facility capable of being viable and effective in a market with growing penetration of variable renewable energy (VRE). Thermal energy storage (TES) represents an ideal technology for this purpose. The current effort will complete a feasibility study to prepare for the Phase II pre-front end engineering design (pre-FEED) for implementing a crushed-rock TES system integrated with a natural gas combined cycle (NGCC) plant. The crushed rock storage technology, which is being developed by Brenmiller Energy, is a modular TES system termed bGen™, which can accommodate both thermal and electrical inputs and output steam, hot water, or hot air. For this application, the estimated efficiency is 80% thermal to thermal. The TES technology is being designed to operate on a slipstream from NYPA’s Eugene W. Zeltmann Power Project (Zeltmann) natural gas combined cycle (NGCC) plant. The projected size of the system will be up to 4 MWe with at least 4 hours of storage duration, or 16 MWh-e total. Final sizing is being determined during the ongoing feasibility study. The next-step pilot being designed as part of the current project will represent a 5-fold increase in scale for this TES technology, and will be used to validate the technology’s ability to provide effective and economical energy storage. This pilot would represent the next-to-last demonstration scale before the technology could be commercial ready at GWh-e scales in the 2030 timeframe. This project is expected to design the critical next-step pilot, which will be undertaken in real-world operating conditions to better determine the crushed rock TES technology’s ability to be integrated with an NGCC plant and assess degradation over transient cycling at rates befitting various marketplaces. The crushed-rock TES pilot design is a technically feasible next step in the development of the technology and is built upon years of prior testing and demonstration. The proposed TES technology was developed by Brenmiller over the last 8 years and has been tested in 3 generations of demonstration units at various sites, globally. During this field testing, different characteristics and performance of the technology were validated, including the following key features: energy storage capacity, energy storage charge/discharge rate, energy storage loses, energy storage mechanical testing. This presentation will provide an update on the results of the conceptual design study for the modular crushed-rock TES system, integrated with a NGCC power plant.

03 NATURAL GAS↗