Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Stopping Power”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Ion Stopping Powers and CT Numbers

One of the advantages of ion beam therapy is the steep dose gradient produced near the ion's range. Use of this advantage makes knowledge of the stopping powers for all materials through which the beam passes critical. Most treatment planning systems calculate dose distributions using depth dose data measured in water and an algorithm that converts the kilovoltage X-ray computed tomography (CT) number of a given material to its linear stopping power relative to water. Some materials present in kilovoltage scans of patients and simulation phantoms do not lie on the standard tissue conversion curve. The relative linear stopping powers (RLSPs) of 21 different tissue substitutes and positioning, registration, immobilization, and beamline materials were measured in beams of protons accelerated to energies of 155, 200, and 250 MeV; carbon ions accelerated to 290 MeV/n; and iron ions accelerated to 970 MeV/n. These same materials were scanned with both kilovoltage and megavoltage CT scanners to obtain their CT numbers. Measured RLSPs and CT numbers were compared with calculated and/or literature values. Relationships of RLSPs to physical densities, electronic densities, kilovoltage CT numbers, megavoltage CT numbers, and water equivalence values converted by a treatment planning system are given. Usage of CT numbers and substitution of measured values into treatment plans to provide accurate patient and phantom simulations are discussed.

07 ISOTOPE AND RADIATION SOURCES↗

SU-F-J-193: Efficient Dose Extinction Method for Water Equivalent Path Length (WEPL) of Real Tissue Samples for Validation of CT HU to Stopping Power Conversion

Purpose: For proton therapy, an accurate model of CT HU to relative stopping power (RSP) conversion is essential. In current practice, validation of these models relies solely on measurements of tissue substitutes with standard compositions. Validation based on real tissue samples would be much more direct and can address variations between patients. This study intends to develop an efficient and accurate system based on the concept of dose extinction to measure WEPL and retrieve RSP in biological tissue in large number of types. Methods: A broad AP proton beam delivering a spread out Bragg peak (SOBP) is used to irradiate the samples with a Matrixx detector positioned immediately below. A water tank was placed on top of the samples, with the water level controllable in sub-millimeter by a remotely controlled dosing pump. While gradually lowering the water level with beam on, the transmission dose was recorded at 1 frame/sec. The WEPL were determined as the difference between the known beam range of the delivered SOBP (80%) and the water level corresponding to 80% of measured dose profiles in time. A Gammex 467 phantom was used to test the system and various types of biological tissue was measured. Results: RSP for all Gammex inserts, expect the one made with lung-450 material (<2% error), were determined within ±0.5% error. Depends on the WEPL of investigated phantom, a measurement takes around 10 min, which can be accelerated by a faster pump. Conclusion: Based on the concept of dose extinction, a system was explored to measure WEPL efficiently and accurately for a large number of samples. This allows the validation of CT HU to stopping power conversions based on large number of samples and real tissues. It also allows the assessment of beam uncertainties due to variations over patients, which issue has never been sufficiently studied before.

60 APPLIED LIFE SCIENCES↗

Stopping power for a charged particle moving through three-dimensional nonideal finite-temperature electron gases

We investigate the interaction of a charged particle with nonideal 3D electron gases by using the quantum hydrodynamic (QHD) theory. The stopping power for a nonideal electron gas at a finite-temperature has been theoretically analyzed and numerically calculated. In our calculation, the impact of nonideality and temperature on stopping power is stressed and clearly presented. The QHD dielectric function is obtained and compared to random-phase approximation result. It is shown that the QHD theory can properly describe the stopping power for higher particle velocities greater than the Bohr velocity.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Study of stopping power for a proton moving in a plasma with arbitrary degeneracy

Excitation of bulk solid electrons with arbitrary degeneracy, by external charged particles, is investigated by a two-dimensional nonlinear quantum hydrodynamic (QHD) model. The nonlinear stopping power and wake potential are calculated by solving the nonlinear QHD equations with the flux corrected transport numerical method. Two cases of fully degenerated and partially degenerated electrons are compared and discussed in the same self-consistent QHD model. Our results are consistent with the well known dielectric calculation of the stopping power at higher velocity, but include the nonlinear terms of the interactions and give larger stopping power at smaller velocity.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measuring stopping power in warm dense matter plasmas at OMEGA

A platform has been developed for accurately measuring the stopping power of high energy protons through warm dense matter (WDM) plasmas characterized by x-ray Thomson scattering. Here, in this work, stopping power measurements were successfully made through both WDM Beryllium and Boron plasmas. In the Boron experiments, an increase in stopping was observed over their cold target counter-parts. This increase in stopping was shown to agree well with models that account for the partial ionization of the plasma.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Nonlinear wake potential and stopping power for charged particles interacting with a one-dimensional electron gas

We examine the interaction of particles with a one-dimensional electron gas by employing the quantum hydrodynamic (QHD) theory, where the nonlinear wake potential and stopping power have been numerically calculated by solving the nonlinear QHD equations with flux corrected transport (FCT) numerical method. In our calculation, the nonlinear effects on the wake potential and stopping power are clearly observed and presented. In the moving coordinate, comparisons are made between the nonlinear and linear wake potentials, in which the maximum values are larger and more oscillations appear behind the projectile in a nonlinear case in contrast to that in a linear case. The nonlinear wake potentials show a clear dependence on time, that is, the FCT algorithm solves the nonlinear QHD equations by time integration starting from the initial time. It is shown that the nonlinear effects can enhance the wake potential and stopping power for particle velocities greater than a few Bohr velocities.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Trajectory sampling and finite-size effects in first-principles stopping power calculations

Abstract Real-time time-dependent density functional theory (TDDFT) is presently the most accurate available method for computing electronic stopping powers from first principles. However, obtaining application-relevant results often involves either costly averages over multiple calculations or ad hoc selection of a representative ion trajectory. We consider a broadly applicable, quantitative metric for evaluating and optimizing trajectories in this context. This methodology enables rigorous analysis of the failure modes of various common trajectory choices in crystalline materials. Although randomly selecting trajectories is common practice in stopping power calculations in solids, we show that nearly 30% of random trajectories in an FCC aluminum crystal will not representatively sample the material over the time and length scales feasibly simulated with TDDFT, and unrepresentative choices incur errors of up to 60%. We also show that finite-size effects depend on ion trajectory via “ouroboros” effects beyond the prevailing plasmon-based interpretation, and we propose a cost-reducing scheme to obtain converged results even when expensive core-electron contributions preclude large supercells. This work helps to mitigate poorly controlled approximations in first-principles stopping power calculations, allowing 1–2 order of magnitude cost reductions for obtaining representatively averaged and converged results.

36 MATERIALS SCIENCE↗

SU-E-J-83: Ion Imaging to Better Estimate In-Vivo Relative Stopping Powers Using X-Ray CT Prior-Knowledge Information

Purpose: To reduce uncertainties in relative stopping power (RSP) estimates for ions (alpha and carbon) by using Ion radiographic-imaging and X-ray CT prior-knowledge. Methods: A 36×36 phantom matrix composed of 9 materials with different thicknesses and randomly placed is generated. Theoretical RSPs are calculated using stopping power (SP) data from three references (Janni, ICRU49 and Bischel). We introduced an artificial systematic error (1.5%, 2.5% or 3.5%) and a random error (<0.5%) to the SP to simulated patient ion-range errors present in clinic environment. Carbon/alpha final energy for each RSPs set (theoretical and from CT images) is obtained with a ray-tracing algorithm. A gradient descent (GD) method is used to minimize the difference in exit particle energy, between theory and X-ray CT RSP maps, by iteratively correcting the RSP map from X-ray CT. Once a new set of RSPs is obtained for a direction a new optimization is done over other direction using the RSPs from the previous optimization. Theoretical RSPs are compared with experimental RSPs obtained with Gammex Phantom. Results: Preliminary results show that optimized RSP values can be obtained with smaller uncertainties (<1%) than clinical RSPs (1.5% to 3.5%). Theoretical values from three different references show uncertainties, up to 3% from experimental values. Further investigation will consider prior-knowledge from RSP obtained with CT images and ion radiographies from Monte Carlo Simulations. Conclusion: GD and ray-tracing methods have been implemented to reduce RSP uncertainties from values obtained for clinical treatment. Experimental RSPs will be obtained using carbon/alpha beams to consider the existence of material dependent systematic errors. Based on the results, it is hoped to show that using ray-tracing optimization with ion radiography and prior knowledge on RPSs, treatment planning accuracy and cost-effectiveness can be improved.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Calculation of the relativistic Bloch correction to stopping power

Bloch's technique of joining the nonrelativistic Bethe and Bohr stopping-power expressions by taking into account wave-packet effects for close collisions is extended to the relativistic case. It is found that Bloch's nonrelativistic correction term must be modified and that charge asymmetric terms appear. Excellent agreement is observed by comparing the results of these calculations to recent data on the stopping power of relativistic heavy ions.

Ahlen, S. P.↗

Stopping-power enhancement from discrete particle-wake correlations in high-energy-density plasmas

Three-dimensional (3D) simulations of electron beams propagating in high-energy-density plasmas using the quasistatic Particle-in-Cell (PIC) code QuickPIC demonstrate a significant increase in stopping power when beam electrons mutually interact via their wakes. Each beam electron excites a plasma wave wake of wavelength ~ 2 π c / ω p e , where c is the speed of light and ω p e is the background plasma frequency. Here we show that a discrete collection of electrons undergoes a beam-plasma-like instability caused by mutual particle-wake interactions that causes electrons to bunch in the beam, even for beam densities n b for which fluid theory breaks down. This bunching enhances the beam's stopping power, which we call “correlated stopping,” and the effect increases with the “correlation number” N b ≡ n b ( c / ω p e ) 3 . For example, a beam of monoenergetic 9.7 MeV electrons with N b = 1 / 8 , in a cold background plasma with n e = 10 26 cm – 3 (450 g cm – 3 DT), has a stopping power of 2.28 ± 0.04 times the single-electron value, which increases to 1220 ± 5 for N b = 64 . The beam also experiences transverse filamentation, which eventually limits the stopping enhancement.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Nuclear stopping power in warm and hot dense matter

We present a method to estimate the nuclear component of the stopping power of ions propagating in dense matter. Three kinds of effective pair potentials are proposed. Results from the warm dense matter regime and the domain of high energy density physics are presented and discussed for proton and helium. The role of ionic temperature is examined. The nuclear stopping power can play a noticeable role in hot dense matter.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Comparison of Stopping Power and Range Databases for Radiation Transport Study

The codes used to calculate stopping power and range for the space radiation shielding program at the Langley Research Center are based on the work of Ziegler but with modifications. As more experience is gained from experiments at heavy ion accelerators, prudence dictates a reevaluation of the current databases. Numerical values of stopping power and range calculated from four different codes currently in use are presented for selected ions and materials in the energy domain suitable for space radiation transport. This study of radiation transport has found that for most collision systems and for intermediate particle energies, agreement is less than 1 percent, in general, among all the codes. However, greater discrepancies are seen for heavy systems, especially at low particle energies.

Tai, H.↗

SU-F-T-136: Breath Hold Lung Phantom Study in Using CT Density Versus Relative Stopping Power Ratio for Proton Pencil Beam Scanning System

Purpose: To evaluate mass density effects of CT conversion table and its variation in current treatment planning system of spot scanning proton beam using an IROC proton lung phantom for this study. Methods: A proton lung phantom study was acquired to Imaging and Radiation Oncology Core Houston (IROC) Quality Assurance Center. Inside the lung phantom, GAF Chromic films and couples of thermal luminescent dosimeter (TLD) capsules embedded in specified PTV and adjacent structures to monitor delivered dosage and 3D dose distribution profiles. Various material such as cork (Lung), blue water (heart), Techron HPV (ribs) and organic material of balsa wood and cork as dosimetry inserts within phantom of solid water (soft tissue). Relative stopping power (RLSP) values were provided. Our treatment planning system (TPS) doesn’t require SP instead relative density was converted relative to water. However lung phantom was irradiated by planning with density override and the results were compared with IROC measurements. The second attempt was conducted without density override and compared with IROC’s. Results: The higher passing rate of imaging and measurement results of the lung phantom irradiation met the criteria by IROC without density override. The film at coronal plane was found to be shift due to inclined cylinder insertion. The converted CT density worked as expected to correlate relative stopping power. Conclusion: The proton lung phantom provided by IROC is a useful tool to qualify our commissioned proton pencil beam delivery with TPS within reliable confidence. The relative mass stopping power ratios of materials were converted from the relative physical density relative to water and the results were satisfied.

60 APPLIED LIFE SCIENCES↗

SU-E-T-280: Dose Evaluation in Using CT Density Versus Relative Stopping Power for Pencil Beam Planning and Treating IROC Proton Phantom

Purpose: The purpose of this study is to evaluate any effects of converted CT density variation in treatment planning system (TPS) of spot scanning proton therapy with an IROC proton prostate phantom at our new ProteusOne Proton Therapy Center. Methods: A proton prostate phantom was requested from the Imaging and Radiation Oncology Core Houston (IROC), The University of Texas MD Anderson Cancer Center, Houston, TX, where GAF Chromic films and couples of thermo luminescent dosemeter (TLD) capsules in target and adjacent structures were embedded for imaging and dose monitoring. Various material such as PVC, PBT HI polystyrene as dosimetry inserts and acrylic were within phantom. Relative stopping power (SP) were provided. However our treatment planning system (TPS) doesn’t require SP instead relative density was converted relative to water in TPS. Phantom was irradiated and the results were compared with IROC measurements. The range of relative density was converted from SP into relative density of water as a new assigned material and tested. Results: The summary of TLD measurements of the prostate and femoral heads were well within 2% of the TPS and met the criteria established by IROC. The film at coronal plane was found to be shift in superior-inferior direction due to locking position of cylinder insert was off and was corrected. The converted CT density worked precisely to correlated relative stopping power. Conclusion: The proton prostate phantom provided by IROC is a useful methodology to evaluate our new commissioned proton pencil beam and TPS within certain confidence in proton therapy. The relative stopping power was converted into relative physical density relatively to water and the results were satisfied.

60 APPLIED LIFE SCIENCES↗

SU-E-J-136: Investigation Into Robustness of Stopping Power Calculated by DECT and SECT for Proton Therapy Treatment Planning

Purpose: To investigate the robustness of dual energy CT (DECT) and single energy CT (SECT) proton stopping power calibration techniques and quantify the associated errors when imaging a phantom differing in chemical composition to that used during stopping power calibration. Methods: The CIRS tissue substitute phantom was scanned in a CT-simulator at 90kV and 140kV. This image set was used to generate a DECT proton SPR calibration based on a relationship between effective atomic number and mean excitation energy. A SECT proton SPR calibration based only on Hounsfield units (HUs) was also generated. DECT and SECT scans of a second phantom of known density and chemical composition were performed. The SPR of the second phantom was calculated with the DECT approach (SPR-DECT),the SECT approach (SPR-SECT) and finally the known density and chemical composition of the phantom (SPR-ref). The DECT and SECT image sets were imported into the Pinnacle{sup 3} research release of proton therapy treatment planning. The difference in dose when exposed to a common pencil beam distribution was investigated. Results: SPR-DECT was found to be in better agreement with SPR-ref than SPR- SECT. The mean difference in SPR for all materials was 0.51% for DECT and 6.89% for SECT. With the exception of Teflon, SPR-DECT was found to agree with SPR-ref to within 1%. Significant differences in calculated dose were found when using the DECT image set or the SECT image set. Conclusion: The DECT calibration technique was found to be more robust to situations in which the physical properties of the test materials differed from the materials used during SPR calibration. Furthermore, it was demonstrated that the DECT and SECT SPR calibration techniques can Result in significantly different calculated dose distributions.

60 APPLIED LIFE SCIENCES↗

Determination of the maximum energy loss for electron stopping power calculations and its effect on backscattering electron yield in Monte-Carlo simulations applying continuous slowing-down approximation

The maximum energy loss for electron stopping power calculations by the full Penn algorithm within the dielectric formalism is determined with taking into account the contribution of electron and plasmon excitations. Use of these calculated electron stopping powers in Monte Carlo simulations applying continuous slowing down approximation gives the backscattering electron yields in much better agreement with experimental data than previous other theoretical results. The muffin-tin model is used to describe the electron elastic scattering by atom bound in solids with taking into account the exchange correlation and polarization effect.

36 MATERIALS SCIENCE↗