Preheating and premixing effects on NO x emissions in a high-pressure axially staged combustor
NO x emissions remain a primary concern for modern and future gas turbines, particularly as we progress towards a net-zero carbon future. It is critical to identify novel strategies to mitigate environmental pollutants for both modern turbines operated on natural gas and future turbines projected to use carbon-free fuels (such as hydrogen). In the current study, NO x emissions of a reacting methane-air jet in a vitiated crossflow are experimentally investigated in a model axially staged combustor at 5 atm. The combustion products from the main stage combustor flow into the axial stage at temperatures ranging from 1580 to 1650 °C. The axial stage contains a reacting jet in crossflow, which provides an overall temperature rise ranging from 50 to 220 °C to generate exit temperatures similar to gas turbine engines. The focus of this paper is to explore the effects of flame liftoff and ignition timescales on the NO x contribution of this secondary jet. This is done by varying the premixed level and preheat temperature of the axial jet. The effects are explored at different momentum flux ratios (J), jet equivalence ratios (φ jet ), exit temperatures (T exit ), and main stage (headend) temperatures (T HE ). High-speed CH* chemiluminescence imaging is employed for each test case to determine the flame stabilization point. For a given temperature rise and combustor exit temperature, an increase in ignition delay was observed with a decrease in jet temperature. This provided a NO x benefit, particularly for jets that are injected at or close to an ignitable mixture fraction. Similarly, the coaxial injector caused a significant ignition delay compared to the fully premixed injector; this also led to a NO x benefit. Overall, the results show that a thermally driven delay in the axial stage provides a greater NO x reduction than a mixing delay.