Characterization of mechanical properties and deformation behavior of highly irradiated 316L stainless steel from target modules at the Spallation Neutron Source using digital image correlation analysis

Tensile specimens with irradiation doses ranging from approximately 0.7 to 7.6 displacements per atom (dpa) were fabricated from 316L samples removed from Spallation Neutron Source (SNS) target vessels after service. Tensile tests were performed in conjunction with digital image correlation (DIC) characterization, which permitted detailed analysis of the strain distribution and deformation behavior of the specimen gauge sections during testing. The results show, while considerable hardening (500–700 MPa increase in yield strength) occurred in the 316L SNS target material with increasing dose, appreciable ductility (19–23% total elongation) remained in the material after irradiation to 7.6 dpa in the mixed neutron/proton environment of the SNS target region. The DIC data showed the strain distribution and deformation behavior of all irradiated specimens were nonuniform during testing. Strain localization in the form of deformation bands or “hotspots” was observed during testing, and in some specimens, the bands propagated as deformation waves along the gauge section. The “traveling wave” deformation behavior affected the amount of elongation each specimen achieved, and the scatter in the elongation data was attributed to the large variation in deformation behavior observed among different specimens. Bands of localized strain, or deformation bands, oriented at specific angles were observed in two-dimensional plots of the strain distribution in the gauge sections of some specimens. Overall, this paper describes the experimental procedures, results, and deformation behavior of tensile specimens from SNS targets after service and illustrates the value of DIC characterization during tensile testing of irradiated materials.

36 MATERIALS SCIENCE↗

Thermal loading analysis of the ring injection dump for the Spallation Neutron Source facility

The ring injection dump (RID) is the largest beam dump in the Spallation Neutron Source facility at Oak Ridge National Laboratory and accepts a fraction of the beam from the ring that is not captured in the ring during injection. Thermo-fluid modeling of the RID components was performed during the initial design by using the software ANSYS CFX to characterize the power rating for the RID. From the calculations, the power rating was lowered from 200 kW to 150 kW, at 1.3 GeV beam energy due to concerns regarding the heating of the concrete structure. The Proton Power Upgrade project scope included reevaluating the power limit to the RID in anticipation that increasing it would provide more operational flexibility. The focus was on the shielding because it was the limiting factor, and data collected from thermocouples installed on the structure were used to benchmark the analysis. A three-stage process was adopted in the latest study. First, the already existing steady-state calculations were validated and extended with the latest Monte Carlo N-Particle source term calculations. Second, transient calculations were conducted to capture the dynamic state of the system in response to the energy dumped to the RID during the following operational period of the beam from 2005–2019 (14 years), and sensitivity analyses of crucial parameters were performed to benchmark the model with reasonable accuracy. Finally, an idealized transient cycle analysis was conducted with realistic duty factors to predict the temperature distribution at higher beam powers. Overall, the results confirmed the accuracy of the original steady state model but allowed the development of a new validated transient model with higher accuracy for future analyses.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The development of a 6 Li-based pixelated neutron detector for neutron reflectometry at the Spallation Neutron Source

We present a high-rate 6 Li-based pixelated neutron detector developed for neutron reflectometry instruments at the Spallation Neutron Source (SNS). The neutron detector has a pixelated design: each 6 Li scintillator element has its own photosensor and independent channel readout. This paper focuses on the general overview of the detector design and construction, the characterization of the pixelated detector, and the results of the first neutron reflectivity experiments conducted using the pixelated neutron detector at the SNS Liquid Reflectometer (BL-4B). The pixelated neutron detector demonstrated a global time-average count rate of ≥ 1.8 x 10 6 cps, at least 3 orders of magnitude higher than that of the existing neutron detector ( 3 He-based Multi-Wire Proportional Counter), and a local instantaneous count rate of ≥ 1.73 x 10 6 cps / cm 2 . The maximum counting rate of the detector has not yet been determined as the detector is capable of handling the maximum flux available at the beamline. Furthermore, the outcome of the neutron reflectivity experiments showed that the pixelated neutron detector is a promising candidate for next-generation neutron reflectometry instruments at the SNS.

6Li, silicon photomultiplier↗

Four-dimensional emittance measurement at the Spallation Neutron Source

A coasting hadron beam with an elliptical transverse profile, uniform charge density, and small transverse four-dimensional (4D) emittance could improve accelerator performance in several contexts. A phase space painting method to generate such a distribution is being tested in the Spallation Neutron Source (SNS) accumulator ring. A critical component of these efforts is to measure the 4D emittance of the beam during accumulation. The 4D emittance can be reconstructed from measured beam profiles in two ways: in the multi-optics method, the optics between a reconstruction and measurement location are varied; in the fixed-optics method, multiple measurement locations are used without modifying the optics. The fixed-optics method is faster but can lead to large uncertainty in the reconstructed 4D emittance. In this paper, we implement a variant of the multi-optics method using the four available wire-scanners near the SNS target. We also modify the wire-scanner region to reduce the uncertainty of the fixed-optics method. We then demonstrate the usefulness of the fixed-optics method by reconstructing the 4D emittance evolution during accumulation in the SNS ring.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A realistic guide misalignment model for the Second Target Station instruments at the Spallation Neutron Source

The Second Target Station (STS) at the Spallation Neutron Source, including a suite of initial instrument concepts, are being designed in Oak Ridge. The moderator size at STS is significantly smaller than that of the First Target Station, making the guide misalignment a more prominent concern. Here a realistic misalignment model based on Monte Carlo neutron ray tracing simulation was developed to evaluate the impacts of both the random misalignment and floor settlement on the performance of a toy model of 150 m straight guide system, and MENUS, an STS instrument concept with a typical guide design of two opposing Montel mirrors. The study shows that longer instruments, and instruments with complex curved mirrors/guides are sensitive to significant performance penalties due to misalignments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optimization of neutron chopper and optics for CENTAUR, the SANS/WANS diffractometer at the spallation neutron source second target station

Herein this report presents the physics design and optimization of the neutron chopper and optics systems for the CENTAUR instrument, a multifunctional small-angle and wide-angle neutron scattering diffractometer for the Spallation Neutron Source Second Target Station. This instrument will offer a wide range of capabilities, including small-angle neutron scattering with wide Q coverage (e.g., 0.001–20 Å –1 ), providing a tool to investigate structures from atomic to mesoscopic scales simultaneously. To efficiently transport desired neutrons from the compact high-brightness cold source, several innovative designs are utilized: a time-zero chopper with a straight guide system for short-wavelength neutrons, octagonal guides for higher flux, and a correlation chopper to reduce inelastic scattering. The optimization process considers factors such as useable time-integrated flux, instrument resolution, brilliance transfer, divergence, and acceptance diagram uniformity. The overall design prioritizes flexibility to accommodate diverse user requirements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Model calibration of the liquid mercury spallation target using evolutionary neural networks and sparse polynomial expansions

The mercury constitutive model predicting the strain and stress in the target vessel plays a central role in improving the lifetime prediction and future target designs of the mercury targets at the Spallation Neutron Source. We leverage the experiment strain data collected over multiple years to improve the mercury constitutive model through a combination of large scale simulations of the target behavior and the use of machine learning tools for parameter estimation. We present two interdisciplinary approaches for surrogate-based model calibration of expensive simulations using evolutionary neural networks and sparse polynomial expansions. The newly calibrated simulations achieve 7% average improvement on the prediction accuracy and 8% reduction in mean absolute error compared to previously reported reference parameters, with some individual sensors experiencing up to 30% improvement. The calibrated simulations can aid in fatigue analysis to estimate the mercury target lifetime, which reduces abrupt failure and saves tremendous amount of costs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Particle physics at the European Spallation Source

Presently under construction in Lund, Sweden, the European Spallation Source (ESS) will be the world’s brightest neutron source. As such, it has the potential for a particle physics program with a unique reach and which is complementary to that available at other facilities. This paper describes proposed particle physics activities for the ESS. Furthermore, these encompass the exploitation of both the neutrons and neutrinos produced at the ESS for high precision (sensitivity) measurements (searches).

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Assessment of simulated and observed cavitation-induced erosion damage in Spallation Neutron Source target vessels

Cavitation-induced erosion damage in different Spallation Neutron Source (SNS) target designs are simulated using explicit finite element–based techniques and compared with observations of erosion in targets after operation. The efficacy of the previously developed method, called saturation time, was evaluated using erosion-damaged samples from new target designs. A new metric called maximum bubble size was implemented under the rationale that larger cavitation bubbles will collapse more intensely. The maximum cavitation bubble size over 1 ms of simulated time was calculated based on the Rayleigh–Plesset equation for each element integration point and presented as a contour map at the vessel surface for assessing with erosion observations. SNS targets are now operated with helium gas injection to reduce cavitation damage. A simulation method using a material model for the mixture of mercury and gas bubbles was recently developed and used to account for the effect of small gas bubbles on the structural response of the target vessel. Furthermore, this work compares the new method's results with observed cavitation damage. Maps of the calculated maximum bubble size for targets operated with and without gas injection were compared with photographs of erosion damage observed in SNS targets. The patterns in maximum bubble size maps correlated well with observations of erosion patterns in target vessels after service. Advantages and challenges of the maximum bubble size simulation technique are provided, and differences between results from the previous and the newly proposed metric are discussed.

Jiang, Hao↗

Relative Source Time Functions, Spectral Ratios, and Near‐Source Spallation in the Source Physics Experiment Phase I Chemical Explosions

The Source Physics Experiment (SPE) Phase I was composed of six chemical explosions at the Nevada National Security Sites (NNSS) between 2011 and 2016. The experiment provided a robust set of dense, local to regional distance observations suitable for characterizing shallow chemical explosions located within the same borehole. We investigate the time-dependent source processes of each chemical explosion using Relative Source Time Function (RSTF) estimation, derived from five linear seismometer profiles located between 100 and 2000 m of the shot location. The RSTF estimate provide a detailed characterization of each chemical explosion's time-history. Subsequent modeling efforts suggest these measurements may be useful for precise characterization of explosion processes and spallation. RSTF estimation allows us to expand our understanding of the SPE Phase I chemical explosion series. Application of these techniques contributes to our understanding of explosion source physics and facilitates future applications to additional seismic source experiments and characterization of explosion phenomenology.

58 GEOSCIENCES↗

The neutron electric dipole moment experiment at the Spallation Neutron Source

Novel experimental techniques are required to make the next big leap in neutron electric dipole moment experimental sensitivity, both in terms of statistics and systematic error control. The nEDM experiment at the Spallation Neutron Source (nEDM@SNS) will implement the scheme of Golub & Lamoreaux [Phys. Rep., 237, 1 (1994)]. The unique properties of combining polarized ultracold neutrons, polarized 3 He, and superfluid 4He will be exploited to provide a sensitivity to ~ 10-28 e · cm. Our cryogenic apparatus will deploy two small (3 L) measurement cells with a high density of ultracold neutrons produced and spin analyzed in situ. The electric field strength, precession time, magnetic shielding, and detected UCN number will all be enhanced compared to previous room temperature Ramsey measurements. Our 3 He co-magnetometer offers unique control of systematic effects, in particular the Bloch-Siegert induced false EDM. Furthermore, there will be two distinct measurement modes: free precession and dressed spin. This will provide an important self-check of our results. Following five years of “critical component demonstration,” our collaboration transitioned to a “large scale integration” phase in 2018. An overview of our measurement techniques, experimental design, and brief updates are described in these proceedings.

Leung, Kent↗

High-resolution neutron time-of-flight measurements for light water at the Spallation Neutron Source (SNS), Oak Ridge National Laboratory

Series of light water inelastic neutron scattering experiments have been made at the Oak Ridge National Laboratory (ORNL), Spallation Neutron Source (SNS) covering temperatures ranging from 295 K to 600 K and pressures of 1 bar and 150 bar. The temperatures and pressures ranges correspond to that of pressurized light water reactors. The inelastic scattering measurements will help the development of light water thermal scattering kernels, also known as S (α,β) thermal scattering law (TSL), in a consistent fashion given the amount and the quality of the measured data. Light water thermal scattering evaluations available in existing nuclear data libraries have certain limitations and pitfalls. This paper introduces the state of the art of the light water thermal scattering cross-section data not only for room temperature but as well as for reactor operating temperatures, i.e. 550 - 600 K. During the past few years there has been a renewed interest in re-investigating the existing TSL models and utilize the recent experimental data or perform molecular dynamics simulations. It should be pointed out that no single TSL evaluation is based entirely on experimental data and one has to rely on TSL models or a combination of both. New TOF measurement of light water at the SNS, with a detailed description of the experimental setup, measurement conditions, and the associated foreseen results is presented in this paper. The analysis of the experimental data would help in validating the existing approach based on old experimental data or based on molecular dynamic simulations using classical water models, knowledge of which is very important to generate TSL libraries at reactor operating conditions.

Leal, Luiz C.↗

Analysis of the time-of-flight neutron scattering cross-section data for light water measured at the SEQUOIA spectrometer, Spallation Neutron Source (SNS)

Thermal neutron scattering cross-section data for light water available in the major nuclear data libraries observes significant differences especially at reactor operating temperatures. During the past few years there has been a renewed interest in reviewing the existing thermal scattering models and generating more accurate and reliable thermal scattering cross sections using existing experimental data and in some cases based on Molecular Dynamics (MD) simulations. There is a need for performing new time-of-flight experiments at high temperatures and pressures, to have a better understanding of the physics involved in the scattering process that could help improve the existing TSL data.Lack of experimental thermal scattering data for light water at high temperatures led to a new measurement campaign within the INSIDER project at the Institut de radioprotection et de sûreté nucléaire (IRSN). Double differential scattering cross section for light water have been measured at the SEQUOIA spectrometer based at the Spallation Neutron Source (SNS), Oak Ridge National Laboratory, United States. Several measurements have been carried out at different temperatures and pressures corresponding to liquid light water. Measurements at five different incident neutron energies Ei (8, 60, 160, 280 and 800 meV) have been carried out to help exploring different regions of the frequency spectrum. This paper presents the analysis of the dynamic structure factor and the derived frequency spectrum of light water. The analysis of the experimental data would provide one with better confidence, the behavior of thermal scattering cross sections for light water at high temperatures, knowledge of which is very important for the design of novel reactors as well as existing pressurized water reactors.

Jaiswal, V↗

Atomistic study of silicon alloying in the spallation behavior of nanocrystalline aluminum systems

Here, the effect of concentration of the alloying element silicon (Si) on the shock and spall response of aluminum (Al) is studied using classical molecular dynamics (MD) simulations. Silicon is distributed as individual grains and as grain boundaries and the dynamic response under shock is studied for an impact velocity of 1000 m/s. A general trend observed here is that the spallation is almost exclusively intergranular and limited to Al-Si interfaces. The spall strengths are observed to a) decrease with an increase in alloying of Si as grains and b) show little increase for up to 50% grain boundary segregation. An increase in grain size of the whole system showed negligible differences in spall strength, highlighting the significance of concentration of the alloying species rather than its grain size. These results provide an atomistic understanding of light-weight metallic systems under shock compression and pave the way for designing multiphase metal matrix alloys and composites for defense/armor applications.

36 MATERIALS SCIENCE↗

A continuum damage approach to spallation and the role of microinertia

Spall failure is of interest due to its prevalence in high strain rate problems in which the spallation is driven by the interaction of release waves. In this article, a porosity-based damage model that includes microinertial effects is used to examine spall failure. The model is successfully calibrated to plate impact-driven experiments and then used to evaluate experimental conditions producing more extreme strain rate conditions, such as those in laser-driven experiments. The incorporation of microinertia allows us to better understand the increase in apparent macroscopic spall strength seen at high strain rates. Correspondingly, we conclude that the incorporation of microinertial effects improves the model’s predictive capabilities. Microinertial effects result in more severe local tensile stresses that affect the damage evolution, and microinertia can play a significant role in the approach to the material’s ideal strength at extreme loading rates. Additionally, a preliminary parametric study is also carried out to investigate the role of microstructural aspects such as nucleation volume fraction and initial pore radius. One counter-intuitive result from the microinertial effects is that, for a given nucleation site volume fraction, having larger initial pore nucleation sites can lead to an improved macroscopic spall strength.

36 MATERIALS SCIENCE↗

The Complex, Unique, and Powerful Imaging Instrument for Dynamics (CUPI 2 D) at the Spallation Neutron Source (invited)

The Oak Ridge National Laboratory is planning to build the Second Target Station (STS) at the Spallation Neutron Source (SNS). STS will host a suite of novel instruments that complement the First Target Station’s beamline capabilities by offering an increased flux for cold neutrons and a broader wavelength bandwidth. A novel neutron imaging beamline, named the Complex, Unique, and Powerful Imaging Instrument for Dynamics (CUPI 2 D), is among the first eight instruments that will be commissioned at STS as part of the construction project. CUPI 2 D is designed for a broad range of neutron imaging scientific applications, such as energy storage and conversion (batteries and fuel cells), materials science and engineering (additive manufacturing, superalloys, and archaeometry), nuclear materials (novel cladding materials, nuclear fuel, and moderators), cementitious materials, biology/medical/dental applications (regenerative medicine and cancer), and life sciences (plant–soil interactions and nutrient dynamics). The innovation of this instrument lies in the utilization of a high flux of wavelength-separated cold neutrons to perform real time in situ neutron grating interferometry and Bragg edge imaging—with a wavelength resolution of δλ/λ ≈ 0.3%—simultaneously when required, across a broad range of length and time scales. This manuscript briefly describes the science enabled at CUPI 2 D based on its unique capabilities. The preliminary beamline performance, a design concept, and future development requirements are also presented.

47 OTHER INSTRUMENTATION↗

Dynamic compression and spallation behavior of NbTaTiVZr high-entropy alloy

High-entropy alloys are a new class of materials with promising properties for aerospace and defense applications. The unique behavior of these materials is driven by the complex interactions between dissimilar atoms in a crystal and requires combined theoretical and experimental efforts to unlock their full potential. Here, we evaluate the relationship between the microstructure and the dynamic response of the equiatomic NbTaTiVZr alloy. Specifically, the shock Hugoniot, or equation of state, was measured up to a particle velocity of 0.5 mm μs −1 using gas gun plate impacts. Shock wave profile and incipient spallation experiments were used to characterize wave propagation and damage formation with post-mortem recovery experiments. Molecular dynamics simulations confirm the experimental findings and extend them up to 2.1 mm μs −1 particle velocity. Computational thermodynamic calculation of phase diagram simulations explain details of the material microstructure, which explains the measured strength and experimental damage patterns. Overall, this work provides detailed high-strain-rate characterization of a refractory high-entropy alloy, and more importantly, a framework and demonstration of the utility and necessity of a combined theoretical and experimental approach, outlining the importance of considering processing and manufacturing conditions when evaluating the performance of new materials.

36 MATERIALS SCIENCE↗

A compact in situ polarized 3He neutron spin filter for the diffractometer VULCAN at the Spallation Neutron Source

We have built and commissioned a compact in situ 3He polarizer based on spin-exchange optical pumping for the engineering materials diffractometer, named VULCAN, at the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory. The system achieved 78% 3He polarization with a short pump-up time constant of 2.2 h. Its first deployment in an in situ half-polarized neutron diffraction experiment on a magnetic shape memory alloy, Ni–Mn–Ga, revealed changes in magnetization coupled to deformation twinning under compression. With this new capability, VULCAN has become the first diffractometer at SNS capable of performing polarized neutron experiments, opening new opportunities to study a wider range of magnetism-related material behaviors under varied thermal, mechanical, electrical, and/or magnetic fields.

Fu, Sichao [ORNL] (ORCID:0009000846771640)↗