Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Space Mirror”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Hubble Space Telescope secondary mirror vertex radius/conic constant test

The Hubble Space Telescope backup secondary mirror was tested to determine the vertex radius and conic constant. Three completely independent tests (to the same procedure) were performed. Similar measurements in the three tests were highly consistent. The values obtained for the vertex radius and conic constant were the nominal design values within the error bars associated with the tests. Visual examination of the interferometric data did not show any measurable zonal figure error in the secondary mirror.

Parks, Robert↗

Chiral mirrors

Mirrors are used in telescopes, microscopes, photo cameras, lasers, satellite dishes, and everywhere else, where redirection of electromagnetic radiation is required making them arguably the most important optical component. While conventional isotropic mirrors will reflect linear polarizations without change, the handedness of circularly polarized waves is reversed upon reflection. Here, we demonstrate a type of mirror reflecting one circular polarization without changing its handedness, while absorbing the other. The polarization-preserving mirror consists of a planar metasurface with a subwavelength pattern that cannot be superimposed with its mirror image without being lifted out of its plane, and a conventional mirror spaced by a fraction of the wavelength from the metasurface. Such mirrors enable circularly polarized lasers and Fabry-Pérot cavities with enhanced tunability, gyroscopic applications, polarization-sensitive detectors of electromagnetic waves, and can be used to enhance spectroscopies of chiral media.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Effects of various cavity designs on the performance of a CO2 TEA laser with an unstable resonator

Unstable resonator modeling has been carried out for an injection-seeded CO2 transversely excited atmosphere (TEA) laser in the NOAA/ERL/Wave Propagation Laboratory (WPL) Doppler lidar to examine the effects of various cavity designs on the quality of the output beam. The results show the effects of an injection pinhole, electrode spacing, mirror tilt, and radial reflectivity function of the output coupler. The electrode spacing in this laser has negligible effect. The injection pinhole, however, produces complicated structures in the output patterns. If the pinhole is removed, the output pattern is much smoother, and the frequency jitter is smaller. Misalignment sensitivity is very closely related to the radial reflectivity function. The superparabolic function provides the highest coupling efficiency, largest beam size, and good collimation, but produces a slightly higher misalignment sensitivity compared with a parabolic function. The Gaussian function provides the lowest misalignment sensitivity, but it produces the smallest beam size and the largest beam divergence. Also, the coupling coefficient is 50 percent lower than the optimum value. Methods for using a flat diffraction grating in unstable resonators are also investigated. The best way is to use a flat grating/positive lens combination to replace the back concave mirror.

Zhao, Yanzeng↗

Mirror instability in space plasmas: Solitons and cnoidal waves

The nonlinear theory of magnetic mirror instability (MI) in space plasmas is revisited. The nonlinear dynamics of the MI is analyzed using the perpendicular plasma pressure balance condition and the drift kinetic equation for the ion distribution function as the starting point. In contrast with previous studies we do not rely on the reductive perturbation method and kinetic effects have been included in the model at all stages. It is shown that the MI initially produces a depression in the magnetic field that has an explosive behavior as was predicted previously. However, this process rapidly terminates and reaches finally saturation with the formation of stationary solutions in the form of either soliton type magnetic holes, cnoidal waves, or linear oscillations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Charter and activities of the SIRTF in-orbit checkout focus integrated products team and optical performance of the CTA

We describe a strategy to determine the initial mirror spacing by quantitatively evaluating the shapes of the images formed by the telescope using the Infrared Array Camera and other science instruments. We show that this information can be used to predict the direction and magnitude of the secondary mirror move that will result in the telescope best focus. The tools used to evaluate focus position and optical quality of the in orbit CTA have been qualified during the BRUTUS test are here described.

Integrated↗

Advanced Optics for a Full Quasi-Optical Front Steering ECRH Upper Launcher for ITER

A full quasi-optical setup for the internal optics of the Front Steering Electron Cyclotron Resonance Heating (ECRH) Upper Launcher for ITER was designed, proving to be feasible and favorable in terms of additional flexibility and cost reduction with respect to the former design. This full quasi-optical solution foresees the replacement of the mitre-bends in the final section of the launcher with dedicated free-space mirrors to realize the last changes of directions in the launcher. A description of the launcher is given and its advantages presented. The parameters of the expected output beams as well as preliminary evaluations of truncation effects with the physical optics GRASP code are shown. Moreover, a study of mitre-bends replacement with single mirrors for multiple beams is described. In principle it could allow the beams to be larger at the mirror locations (with a further decrease of the peak power density due to partial overlapping) and has the additional advantage to get a larger opening with compressed beams to avoid conflicts with side-walls port. Constraints on the setup, arising both from the resulting beam characteristics in the space of free parameters and from mechanical requirements are taken into account in the analysis.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

NNSA/CEA Workflow Workshop Report 2021

Researchers from three NNSA labs plus CEA recently met for a half-day workshop on scientific and engineering workflows in March of 2021. Tools, projects and use cases from each institution were described. A wide range of unique capabilities and requirements were represented. The workshop highlights the fact that the CEA/NNSA workflows space mirrors the broader open science workflows community, with multiple technologies under development in a number of science domains and under a number of funding streams, with differing capabilities and focuses. Despite the number of tools, presentations and discussions have shown that these tools cover specific mission spaces at the four labs, each with distinctive capabilities that do not completely overlap with each other. We believe there is a strong interest in the short term for sharing lessons learned and collaborating on benchmarks and site evaluation of projects. This report, prepared by the NNSA/CEA Workflows Working Group, briefly summarizes the presentations in the areas of domain specific workflows, end user environments, data management, job and resource management, and infrastructure, and then identifies six broad areas for potential collaboration. A key finding is that users could benefit from greater interoperability, compatibility, and composability of the workflow technologies under development and that point-to-point collaboration opportunities should be identified to explore these aspects.

97 MATHEMATICS AND COMPUTING↗

Alignment Mirror Mechanisms for Space Use

The paper describes an optical Alignment Mirror Mechanism (AMM), and discusses its control scheme. The mirror's angular positioning accuracy requirement is +/- 0.2 arc-sec. This requires the mirror's linear positioning actuators to have a positioning accuracy of +/- 109 nm to enable the mirror to meet the angular tip/tilt accuracy requirement. Demonstrated capabilities are +/- 35 nm linear positioning capability at the actuator, which translates into +/- 0.07 arc-sec angular mirror positioning accuracy.

optical mounts↗

NASA Tech Briefs, December 2011

Topics covered include: 1) SNE Industrial Fieldbus Interface; 2) Composite Thermal Switch; 3) XMOS XC-2 Development Board for Mechanical Control and Data Collection; 4) Receiver Gain Modulation Circuit; 5) NEXUS Scalable and Distributed Next-Generation Avionics Bus for Space Missions; 6) Digital Interface Board to Control Phase and Amplitude of Four Channels; 7) CoNNeCT Baseband Processor Module; 8) Cryogenic 160-GHz MMIC Heterodyne Receiver Module; 9) Ka-Band, Multi-Gigabit-Per-Second Transceiver; 10) All-Solid-State 2.45-to-2.78-THz Source; 11) Onboard Interferometric SAR Processor for the Ka-Band Radar Interferometer (KaRIn); 12) Space Environments Testbed; 13) High-Performance 3D Articulated Robot Display; 14) Athena; 15) In Situ Surface Characterization; 16) Ndarts; 17) Cryo-Etched Black Silicon for Use as Optical Black; 18) Advanced CO2 Removal and Reduction System; 19) Correcting Thermal Deformations in an Active Composite Reflector; 20) Umbilical Deployment Device; 21) Space Mirror Alignment System; 22) Thermionic Power Cell To Harness Heat Energies for Geothermal Applications; 23) Graph Theory Roots of Spatial Operators for Kinematics and Dynamics; 24) Spacesuit Soft Upper Torso Sizing Systems; 25) Radiation Protection Using Single-Wall Carbon Nanotube Derivatives; 26) PMA-PhyloChip DNA Microarray to Elucidate Viable Microbial Community Structure; 27) Lidar Luminance Quantizer; 28) Distributed Capacitive Sensor for Sample Mass Measurement; 29) Base Flow Model Validation; 30) Minimum Landing Error Powered-Descent Guidance for Planetary Missions; 31) Framework for Integrating Science Data Processing Algorithms Into Process Control Systems; 32) Time Synchronization and Distribution Mechanisms for Space Networks; 33) Local Estimators for Spacecraft Formation Flying; 34) Software-Defined Radio for Space-to-Space Communications; 35) Reflective Occultation Mask for Evaluation of Occulter Designs for Planet Finding; and 36) Molecular Adsorber Coating

Source record↗

Thermal Analysis of Next Generation Space Telescope (NGST) Mirrors During Optical Testing in the X-Ray Calibration Facility (XRCF)

The Next Generation Space Telescope (NGST) program and industry partners are developing extremely lightweight mirror designs. NGST development mirrors are being tested at Marshall Space Flight Center. Target temperature for development mirror testing is 35 K. Conduction and radiation are not sufficient to conduct thermal vacuum testing in a reasonable time. Helium gas is injected into the vacuum chamber to accelerate temperature transitions during testing. Free-molecular conduction can be modeled by adapting present thermal analysis techniques.

Page, Tim↗

Wavefront Calibration Testing of the James Webb Space Telescope Primary Mirror Center of Curvature Optical Assembly

The James Webb Space Telescope (JWST) Optical Telescope Element (OTE) consists of a 6.6 meter clear aperture, all-reflective, three-mirror anastigmat!. The 18-segment primary mirror (PM) presents unique and challenging assembly, integration, alignment and testing requirements. A full aperture center of curvature optical test is performed in cryogenic vacuum conditions at the integrated observatory level to verify PM performance requirements. Two wavefront calibration tests are utilized to verify the low and Mid/High spatial frequency performance ofthe test system. In this paper the methods and results of the wavefront calibration tests are presented.

Olczak, Gene↗

The emergent photophysics and photochemistry of molecular polaritons: a theoretical and computational investigation (Final Technical Report)

When molecules are placed between closely spaced mirrors, they interact strongly with the photons that are trapped between them, generating new quantum states which are no longer exclusively material nor photonic alone, but rather, coherent superpositions of both. These hybrid states are known as molecular polaritons, given that they arise from the strong interaction between the electric field of light and the electrical polarization of the molecules. Recently, experimental advances in nano‐ and microfabrication of molecular polariton architectures have successfully demonstrated their feasibility to control the rate and outcome of a certain class of chemical reactions in condensed phases. Importantly, these reactions proceed in strongly dissipative environments such as liquid solvents and lossy mirrors that allow for photons to escape from their confinement. The purpose of this research is to formulate quantum mechanical theories and computational tools that can elucidate the origin of these intriguing phenomena and simultaneously predict capabilities that this new generation of molecular materials affords. Attention is placed on harnessing polaritons to carry out photophysics and photochemistry that challenge currently existing paradigms, such as the optimization of energy conversion processes in organic solar cell or light‐emitting devices, or unconventional phenomena such as long‐range excitation energy transfer, remote control of chemical reactions, and a new quantum mechanical regime of chemical reactivity due to wavefunction overlaps amongst a large number of molecular polaritons (Bose condensation). This research explores a frontier of Chemistry and Physics where electrons, vibrations, and photons interact strongly with each other to generate emergent behavior that can be creatively exploited to address contemporary challenges in Basic Energy Sciences.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

An optically pumped submillimeter wavelength regenerative amplifier

An optically pumped regenerative submillimeter laser amplifier is described. The amplifier uses a waveguide cavity resonator, and a Fabry-Perot interferometer composed of two dielectric-coated mirrors serves as input and output port for the submillimeter signal. Use of two mirrors enabled obtaining variations of up to 6:1 in transmission by varying the mirror spacing. When the 373-micron transition in CH3CN is excited in the oscillator by the CO2 laser pump beam, the received signal with amplification is about nine times the unamplified signal.

Galantowicz, T. A.↗

Charge transfer reaction laser with preionization means

A helium-nitrogen laser is described in which energy in the visible range is emitted as a result of charge transfer reaction between helium ions and nitrogen molecules. The helium and nitrogen are present in a gas mixture at several atmospheres pressure, with a nitrogen partial pressure on the order of a pair of main discharge electrodes, the gas mixture is preionized to prevent arcing when the discharge pulse is applied. The preionization is achieved by the application of a high voltage across a pair of secondary electrodes which are spaced apart in a direction perpendicular to the spacing direction of the main discharge electrodes and the longitudinal axis of the space in which the gas mixture is contained. Feedback, by means of a pair of appropriately spaced mirrors, is provided, to produce coherent energy pulses at a selected wavelength.

Lauderslager, J. B.↗

Hyperspectral Infrared Imaging of Flames Using a Spectrally Scanning Fabry-Perot Filter

The temperatures and compositions of gases in and around flames can be diagnosed using infrared emission spectroscopy to observe molecular band shapes and intensities. We have combined this approach with a low-order scanning Fabry-Perot filter and an infrared camera to obtain spectrally scanned infrared emission images of a laboratory flame and exhaust plume from 3.7 to 5.0 micrometers, at a spectral resolution of 0.043 micrometers, and a spatial resolution of 1 mm. The scanning filter or AIRIS (Adaptive Infrared Imaging Spectroradiometer) is a Fabry-Perot etalon operating in low order (mirror spacing = wavelength) such that the central spot, containing a monochromatic image of the scene, is viewed by the detector array. The detection system is a 128 x 128 liquid-nitrogen-cooled InSb focal plane array. The field of view is controlled by a 50 mm focal length multielement lens and an V4.8 aperture, resulting in an image 6.4 x 6.4 cm in extent at the flame and a depth of field of approximately 4 cm. Hyperspectral images above a laboratory CH4/air flame show primarily the strong emission from CO2 at 4.3 micrometers, and weaker emissions from CO and H2O. We discuss techniques to analyze the spectra, and plans to use this instrument in microgravity flame spread experiments.

Rawlins, W. T.↗

Status Report and Lessons Learned from the Univ. of Arizona NMSD

We will present the latest generation of space mirror technology being developed at the Univ. of Arizona (UA). Unlike conventional monolithic mirrors, the UA mirrors are completely active in their operation. This allows greater flexibility in the mass, volume and performance specifications. The UA mirror design uses a thin flexible substrate for the optical surface and an actuated lightweight structure for surface accuracy and support. We provide an update on the UA NGST Mirror System Demonstrator (NMSD). The 2-m, f/5 NMSD mirror uses a 2 mm thick glass substrate and weighs 86 pounds. We review the mirror's design, discuss the mythology schemes used to actuate the figure, and present a list of the lessons learned.

Baiocchi, Dave↗

Exep: Environmental Testing of High-Actuator-Count Mems Deformable Mirrors for Space-Based Applications

Coronagraph instruments on future space telescopes will rely on deformable mirrors to create high contrast images for the direct detection of exoplanets. As part of the NASA Exoplanet Explorations Program’s coronagraph technology development efforts, two sets of Micro-electro-mechanical systems (MEMS) deformable mirrors manufactured by Boston Micromachines Corporation were exposed to vibration and thermal cycles representative of launch conditions. The first set were 952-actuator Kilo-DMs that successfully demonstrated 100% actuator survival and achieved ~1e-8 contrast after the environment test. The second round used an engineering-grade 2048-actuator deformable mirror on which few changes were identified after the environmental test. However, each actuator that changed behavior was flagged as anomalous beforehand or was directly adjacent to a defective actuator. From this result, we hypothesized that typical actuators on a science grade deformable mirror are robust to environmental testing. A third set of 2048-actuator deformable mirror have been procured for a planned test to characterize the deformable mirrors using interferometric measurements, contrast results on a new in-air coronagraph testbed, and infrared microscopy on the internal structure of the MEMS devices.

Lam, Charlie↗

Auger@TA: In-situ Cross-Calibration of the World's Largest Cosmic Ray Observatories

The Pierre Auger Observatory (Auger) and the Telescope Array (TA) are the world's two largest ultra-high-energy cosmic ray (UHECR) observatories. They operate in the Southern and Northern hemispheres, respectively, at similar latitudes but with distinct surface detector (SD) designs. A significant challenge in studying UHECR physics across the full sky is the apparent discrepancy in flux measurements between the two experiments. This discrepancy could arise from astrophysical differences and/or systematic effects related to their detector designs and sensitivities to extensive air shower components. To address this, the Auger@TA working group aims to cross-calibrate the two observatories with a self-triggering micro-Auger array within the TA array. This micro-array consists of eight Auger Surface Detector (SD) stations equipped with Water Cherenkov Detectors (WCDs) and AugerPrime Surface Scintillator Detectors. Seven SD stations, configured with a centered-1-PMT design, are arranged in a hexagonal pattern with one station in the center, with 1.5 km spacing, mirroring the Auger layout. The eighth station, which features a standard 3-PMT Auger station, is located in conjunction with a TA detector at the center of the hexagon, forming a triplet for high-statistics and low-uncertainty cross-calibration. A custom communication system that uses readily available components enables seamless communication between stations and remote access to each station through a central computer. The micro-array is now fully deployed, and initial data-taking is about to start. This presentation will detail the instrumentation, communication systems, central data acquisition system, expected performance of the micro-array, and preliminary results as appropriate.

Mocellin, Adriel G.B. [Colorado School of Mines]↗