SEARCH · Engineering Papers
Results for “Software estimation,”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
SU-G-IeP3-05: Effects of Image Receptor Technology and Dose Reduction Software On Radiation Dose Estimates for Fluoroscopically-Guided Interventional (FGI) Procedures
Purpose: To investigate the effects of image receptor technology and dose reduction software on radiation dose estimates for most frequently performed fluoroscopically-guided interventional (FGI) procedures at a tertiary health care center. Methods: IRB approval was obtained for retrospective analysis of FGI procedures performed in the interventional radiology suites between January-2011 and December-2015. This included procedures performed using image-intensifier (II) based systems which were subsequently replaced, flat-panel-detector (FPD) based systems which were later upgraded with ClarityIQ dose reduction software (Philips Healthcare) and relatively new FPD system already equipped with ClarityIQ. Post procedure, technologists entered system-reported cumulative air kerma (CAK) and kerma-area product (KAP; only KAP for II based systems) in RIS; these values were analyzed. Data pre-processing included correcting typographical errors and cross-verifying CAK and KAP. The most frequent high and low dose FGI procedures were identified and corresponding CAK and KAP values were compared. Results: Out of 27,251 procedures within this time period, most frequent high and low dose procedures were chemo/immuno-embolization (n=1967) and abscess drainage (n=1821). Mean KAP for embolization and abscess drainage procedures were 260,657, 310,304 and 94,908 mGycm{sup 2}, and 14,497, 15,040 and 6307 mGycm{sup 2} using II-, FPD- and FPD with ClarityIQ- based systems, respectively. Statistically significant differences were observed in KAP values for embolization procedures with respect to different systems but for abscess drainage procedures significant differences were only noted between systems with FPD and FPD with ClarityIQ (p<0.05). Mean CAK reduced significantly from 823 to 308 mGy and from 43 to 21 mGy for embolization and abscess drainage procedures, respectively, in transitioning to FPD systems with ClarityIQ (p<0.05). Conclusion: While transitioning from II- to FPD- based systems was not associated with dose reduction for the most frequently performed FGI procedures, substantial dose reduction was noted with relatively newer systems and dose reduction software.
Integrated State Estimation and Contingency Analysis Software Implementation using High Performance Computing Techniques
Power system simulation tools are traditionally developed in sequential mode and codes are optimized for single core computing only. However, the increasing complexity in the power grid models requires more intensive computation. The traditional simulation tools will soon not be able to meet the grid operation requirements. Therefore, power system simulation tools need to evolve accordingly to provide faster and better results for grid operations. This paper presents an integrated state estimation and contingency analysis software implementation using high performance computing techniques. The software is able to solve large size state estimation problems within one second and achieve a near-linear speedup of 9,800 with 10,000 cores for contingency analysis application. The performance evaluation is presented to show its effectiveness.
A Software Tool for Automatic Estimation of X-Ray CT Scan Geometry [Slides]
Abstract not provided.
Parameter Estimator for Engineering Systems
This software model generates vehicle parameter sets for downstream modeling applications using real-world data. Value to users is provided through improvements to modeling activities as a result of decreases in time taken during model development and validation. Currently configured for transportation modeling activities, the software provides initial estimates for multiple fundamental vehicle parameters including mass, coefficient of drag, and tire rolling resistance using real-world drive and duty cycle information as inputs.
Interpretation of Flow Logs from Nevada Test Site Boreholes to Estimate Hydraulic conductivity Using Numerical Simulations Constrained by Single-Well Aquifer Tests
Hydraulic conductivities of volcanic and carbonate lithologic units at the Nevada Test Site were estimated from flow logs and aquifer-test data. Borehole flow and drawdown were integrated and interpreted using a radial, axisymmetric flow model, AnalyzeHOLE. This integrated approach is used because complex well completions and heterogeneous aquifers and confining units produce vertical flow in the annular space and aquifers adjacent to the wellbore. AnalyzeHOLE simulates vertical flow, in addition to horizontal flow, which accounts for converging flow toward screen ends and diverging flow toward transmissive intervals. Simulated aquifers and confining units uniformly are subdivided by depth into intervals in which the hydraulic conductivity is estimated with the Parameter ESTimation (PEST) software. Between 50 and 150 hydraulic-conductivity parameters were estimated by minimizing weighted differences between simulated and measured flow and drawdown. Transmissivity estimates from single-well or multiple-well aquifer tests were used to constrain estimates of hydraulic conductivity. The distribution of hydraulic conductivity within each lithology had a minimum variance because estimates were constrained with Tikhonov regularization. AnalyzeHOLE simulated hydraulic-conductivity estimates for lithologic units across screened and cased intervals are as much as 100 times less than those estimated using proportional flow-log analyses applied across screened intervals only. Smaller estimates of hydraulic conductivity for individual lithologic units are simulated because sections of the unit behind cased intervals of the wellbore are not assumed to be impermeable, and therefore, can contribute flow to the wellbore. Simulated hydraulic-conductivity estimates vary by more than three orders of magnitude across a lithologic unit, indicating a high degree of heterogeneity in volcanic and carbonate-rock units. The higher water transmitting potential of carbonate-rock units relative to volcanic-rock units is exemplified by the large difference in their estimated maximum hydraulic conductivity; 4,000 and 400 feet per day, respectively. Simulated minimum estimates of hydraulic conductivity are inexact and represent the lower detection limit of the method. Minimum thicknesses of lithologic intervals also were defined for comparing AnalyzeHOLE results to hydraulic properties in regional ground-water flow models.
Development of a bayesian belief network model for the software reliability assessment of nuclear digital I and C safety systems - 206
Since the digital instrumentation and control systems are expected to play an important role for the safety systems in nuclear power plants (NPPs), the need has emerged to not only establish a basis for incorporating software behavior into digital I and C system reliability models, but also to quantify the failure probability of the software used in NPP digital protection systems. In this study, a Bayesian belief network (BBN) model is developed to quantitatively assess software reliability by estimating the number of faults in a software program considering its software development life cycle (SDLC). The model structure and parameters are established based on the information applicable to NPP safety-related systems and the evidence used to construct and quantify the BBN model was collected from three stages of expert elicitation. The software failure probability is estimated from the number of residual defects in a software program at the end of SDLC phase. As a case study, the BBN model was applied to quantify the software reliability of a typical digital protection software having the size of 50 function points and having the Medium development and validation and verification (V and V) qualities. The developed model can be applied to estimate the failure probability for both developing and deployed safety-related NPP software, and such results can be used to evaluate the quality of the digital I and C systems in addition to estimating potential reactor risk due to software failure. (authors)
IDC reengineering Phase 2 & 3 US industry standard cost estimate summary
Sandia National Laboratories has prepared a ROM cost estimate for budgetary planning for the IDC Reengineering Phase 2 & 3 effort, using a commercial software cost estimation tool calibrated to US industry performance parameters. This is not a cost estimate for Sandia to perform the project. This report provides the ROM cost estimate and describes the methodology, assumptions, and cost model details used to create the ROM cost estimate. ROM Cost Estimate Disclaimer Contained herein is a Rough Order of Magnitude (ROM) cost estimate that has been provided to enable initial planning for this proposed project. This ROM cost estimate is submitted to facilitate informal discussions in relation to this project and is NOT intended to commit Sandia National Laboratories (Sandia) or its resources. Furthermore, as a Federally Funded Research and Development Center (FFRDC), Sandia must be compliant with the Anti-Deficiency Act and operate on a full-cost recovery basis. Therefore, while Sandia, in conjunction with the Sponsor, will use best judgment to execute work and to address the highest risks and most important issues in order to effectively manage within cost constraints, this ROM estimate and any subsequent approved cost estimates are on a 'full-cost recovery' basis. Thus, work can neither commence nor continue unless adequate funding has been accepted and certified by DOE.
Phenocams Bridge the Gap between Field and Satellite Observations in an Arid Grassland Ecosystem
Near surface (i.e., camera) and satellite remote sensing metrics have become widely used indicators of plant growing seasons. While robust linkages have been established between field metrics and ecosystem exchange in many land cover types, assessment of how well remotely-derived season start and end dates depict field conditions in arid ecosystems remain unknown. We evaluated the correspondence between field measures of start (SOS; leaves unfolded and canopy greenness >0) and end of season (EOS) and canopy greenness for two widespread species in southwestern U.S. ecosystems with those metrics estimated from near-surface cameras and MODIS NDVI for five years (2012–2016). Using Timesat software to estimate SOS and EOS from the phenocam green chromatic coordinate (GCC) greenness index resulted in good agreement with ground observations for honey mesquite but not black grama. Despite differences in the detectability of SOS and EOS for the two species, GCC was significantly correlated with field estimates of canopy greenness for both species throughout the growing season. MODIS NDVI for this arid grassland site was driven by the black grama signal although a mesquite signal was discernable in average rainfall years. Our findings suggest phenocams could help meet myriad needs in natural resource management.
SU-F-18C-08: A Validation Study of a Commercially Available Software Package's Absorbed Dose Estimates in a Physical Phantom
Purpose: This study assesses the accuracy of the absorbed dose estimates from CT scans generated by Monte Carlo (MC) simulation using a commercially available radiation dose monitoring software program. Methods: Axial CT studies of an anthropomorphic abdomen phantom with dose bores at a central location and 4 peripheral locations were conducted using a fixed tube current at 120 kV. A 100 mm ion chamber and a 0.6 cc ion chamber calibrated at diagnostic energy levels were used to measure dose in the phantom at each of the 5 dose bore locations. Simulations using the software program's Monte Carlo engine were run using a mathematical model of the anthropomorphic phantom to determine conversion coefficients between the CTDIvol used for the study and the dose at the location of the dose bores. Simulations were conducted using both the software's generic CT beam model and a refined model generated using HVL and bow tie filter profile measurements made on the scanner used for the study. Results: Monte Carlo simulations completed using the generalized beam model differed from the measured conversion factors by an absolute value average of 13.0% and 13.8% for the 100 mm and 0.6 cc ion chamber studies, respectively. The MC simulations using the scanner specific beam model generated conversion coefficients that differed from the CTDIvol to measured dose conversion coefficients by an absolute value average of 7.3% and 7.8% for the 100 mm and 0.6 cc ion chamber cases, respectively. Conclusion: A scanner specific beam model used in MC simulations generates more accurate dose conversion coefficients in an anthropomorphic phantom than those generated with a generalized beam model. Agreement between measured conversion coefficients and simulated values were less than 20% for all positions using the universal beam model.
Graph Neural Networks and Applied Linear Algebra v.1.0
SAND2024-01365O The Graph Neural Networks and Applied Linear Algebra is companion software for the educational article with the same title. The software provides illustrative examples of graph neural networks in Matlab and Python. These stand-alone algorithms are for educational purposes. The software also includes graph neural network-based algorithms for a trainable Jacobi iteration as well as diffusion coefficient estimation. The software provides human-interpretable implementations of Graph Neural Networks in Matlab and Python. These implementations are not optimized for performance and instead emphasize readability. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.
Local models for scatter estimation and descattering in polyenergetic X-ray tomography
We propose a new modeling approach for scatter estimation and descattering in polyenergetic X-ray computed tomography (CT) based on fitting models to local neighborhoods of a training set. X-ray CT is widely used in medical and industrial applications. X-ray scatter, if not accounted for during reconstruction, creates a loss of contrast in CT reconstructions and introduces severe artifacts including cupping, shading, and streaks. Even when these qualitative artifacts are not apparent, scatter can pose a major obstacle in obtaining quantitatively accurate reconstructions. Our approach to estimating scatter is, first, to generate a training set of 2D radiographs with and without scatter using particle transport simulation software. To estimate scatter for a new radiograph, we adaptively fit a scatter model to a small subset of the training data containing the radiographs most similar to it. We compared local and global (fit on full data sets) versions of several X-ray scatter models, including two from the recent literature, as well as a recent deep learning-based scatter model, in the context of descattering and quantitative density reconstruction of simulated, spherically symmetrical, single-material objects comprising shells of various densities. Our results show that, when applied locally, even simple models provide state-of-the-art descattering, reducing the error in density reconstruction due to scatter by more than half.
EnCache: A Dynamic Profiling Based Reconfiguration Technique for Improving Cache Energy Efficiency
With each CMOS technology generation, leakage energy consumption has been dramatically increasing and hence, managing leakage power consumption of large last-level caches (LLCs) has become a critical issue in modern processor design. In this paper, we present EnCache, a novel software-based technique which uses dynamic profiling-based cache reconfiguration for saving cache leakage energy. EnCache uses a simple hardware component called profiling cache, which dynamically predicts energy efficiency of an application for 32 possible cache configurations. Using these estimates, system software reconfigures the cache to the most energy efficient configuration. EnCache uses dynamic cache reconfiguration and hence, it does not require offline profiling or tuning the parameter for each application. Furthermore, EnCache optimizes directly for the overall memory subsystem (LLC and main memory) energy efficiency instead of the LLC energy efficiency alone. The experiments performed with an x86-64 simulator and workloads from SPEC2006 suite confirm that EnCache provides larger energy saving than a conventional energy saving scheme. For single core and dual-core system configurations, the average savings in memory subsystem energy over a shared baseline configuration are 30.0% and 27.3%, respectively.
PyOECP: A flexible open-source software for the measurement and modeling of the dielectric spectrum from the reflection coefficient
We present PyOECP, a Python-based flexible open-source software for estimating and modeling the complex permittivity obtained from the open-ended coaxial probe (OECP) technique. The transformation of the measured reflection coefficient to complex permittivity is performed based on two different models, including the capacitance model and the antenna model. The software library contains dielectric spectra of common reference liquids, which can be used to transform the reflection coefficient into the dielectric spectra. Several Python routines that are commonly employed (e.g., SciPy and NumPy) are only required so that the users can alter the software structure depending on their needs. The modeling algorithm exploits the Markov chain Monte Carlo method for the data regression. The discrete relaxation models can be built by a proper combination of well-known relaxation models. In addition to these models, the electrode polarization, which is a common measurement artifact for interpreting the dielectric spectra, can be incorporated in the modeling algorithm. A continuous relaxation model, which solves the Fredholm integral equation of the first kind (a mathematically ill-posed problem) is also included.
A learning-based measurement framework for traffic matrix inference in software defined networks
Here, we propose an intelligent framework for Traffic Matrix (TM) inference in Software Defined Networks (SDN) where the Ternary Content Addressable Memory (TCAM) entries of switches are partitioned into two parts to: (1) effectively aggregate part of incoming flows for aggregate measurements, and (2) de-aggregate and directly measure the most informative flows for per-flow measurements. These measurements are then processed to effectively estimate the size of network flows. Under hard resource constraints of limited TCAM sizes, we show how to design the optimal and efficient-compressed flow aggregation matrices. We propose an optimal Multi-Armed Bandit (MAB) based algorithm to adaptively measure the most rewarding flows. We evaluate the performance of our framework using real traffic traces from different network environments and by considering two main applications: TM estimation and Heavy Hitter (HH) detection. Moreover, we have implemented a prototype of our framework in Mininet to demonstrate its effectiveness.
PEES (Parameter Estimator for Engineering Systems) [SWR-16-38]
This software model generates vehicle parameter sets for downstream modeling applications using real-world data. Value to users is provided through improvements to modeling activities as a result of decreases in time taken during model development and validation. Currently configured for transportation modeling activities, the software provides initial estimates for multiple fundamental vehicle parameters including mass, coefficient of drag, and tire rolling resistance using real-world drive and duty cycle information as inputs.
Bifacial PV System Mismatch Loss Estimation & Parameterization
Non-uniform irradiance on the rear-side of bifacial PV systems can cause additional mismatch loss which may not be appropriately captured in PV energy production estimates and software. We have evaluated several rooftop mounted systems over high albedo reflective roofs. Mismatch losses of up to 2% annual loss for very close-mounted (0.15 m) rooftop systems were found, but losses for high ground-clearance rooftop systems were lower (<0.5%). A simplified empirical relationship was found that links the spatial variation of irradiance (specifically the mean absolute difference of irradiance) to the resulting mismatch loss factor, with a R2 fit better than 0.985. This approximate relationship has been validated by experiments on mismatched PV modules, and provides a basis for fast estimation of bifacial mismatch loss factors for use in hourly PV performance simulations such as PVSyst or SAM.
Bifacial PV System Mismatch Loss Estimation and Parameterization: Preprint
Non-uniform irradiance on the rear-side of bifacial PV systems can cause additional mismatch loss which may not be appropriately captured in PV energy production estimates and software. We have evaluated several scenarios including horizontal single-axis tracking (HSAT) and rooftop mounted systems over high albedo reflective roofs. Mismatch losses of up to 2% annual loss for very close-mounted (0.15 m) rooftop systems were found, but losses for HSAT systems and high ground-clearance rooftop systems were lower (<0.5%). A simplified empirical relationship was found that links the spatial variation of irradiance (specifically the mean absolute difference of irradiance) to the resulting mismatch loss factor, with a R2 fit better than 0.985. This approximate relationship has been validated by experiments on mismatched PV modules, and provides a basis for fast estimation of bifacial mismatch loss factors for use in hourly PV performance simulations such as PVSyst or SAM.