Importance Ranking of Software Dependability Attributes in the Nuclear Industry

With the current transition from analog to digital instrumentation and control systems in nuclear power plants, the number and variety of software-based systems has significantly increased. Due to the sophisticated nature and the increasing complexity of software, a significant challenge faced by the nuclear industry is the trust one can place in software-based systems once they have been developed. The trust placed in software is typically termed software dependability, a qualifier which encompasses different attributes such as software reliability, safety, security, availability and maintainability. It is recognized that these attributes relate to each other in different ways under various scenarios. The detailed dependencies between software dependability attributes can be found in a previous study. With limited time and budget resources, which dependability attribute should be given the highest priority when certifying software-based systems in the nuclear industry is a fundamental question that needs to be answered. This paper addresses this problem using stakeholders' opinion elicitation. A comprehensive questionnaire was designed to elicit the goals that should be fulfilled by the nuclear industry and to collect the relative importance of the various dependability attributes for each goal. We then used the Analytical Hierarchy Process (AHP) to analyze the data and obtained the relative importance ranking of software dependability attributes in the context of a reactor protection system. The results will provide guidance to resource allocation for the certification of software dependability in the nuclear industry. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a High Fidelity System Analysis Code for Generation IV Reactors

Traditional nuclear reactor system analysis codes such as RELAP and TRAC employ an operator split methodology. In this approach, each of the physics (fluid flow, heat conduction and neutron diffusion) is solved separately and the coupling terms are done explicitly. This approach limits accuracy (first order in time at best) and makes the codes slow in running since the explicit coupling imposes stability restrictions on the time step size. These codes have been extensively tested and validated for the existing LWRs. However, for GEN IV nuclear reactor designs which tend to have long lasting transients resulting from passive safety systems, the performance is questionable and modern high fidelity simulation tools will be required. The requirement for accurate predictability is the motivation for a large scale overhaul of all of the models and assumptions in transient nuclear reactor safety simulation software. At INL we have launched an effort with the long term goal of developing a high fidelity system analysis code that employs modern physical models, numerical methods, and computer science for transient safety analysis of GEN IV nuclear reactors. Modern parallel solution algorithms will be employed through utilizing the nonlinear solution software package PETSc developed by Argonne National Laboratory. The physical models to be developed will have physically realistic length scales and time scales. The solution algorithm will be based on the physics-based preconditioned Jacobian-free Newton-Krylov solution methods. In this approach all of the physical models are solved implicitly and simultaneously in a single nonlinear system. This includes the coolant flow, nonlinear heat conduction, neutron kinetics, and thermal radiation, etc. Including modern physical models and accurate space and time discretizations will allow the simulation capability to be second order accurate in space and in time. This paper presents the current status of the development efforts as well as some results from analyzing a simplified primary system model of GNEP’s advanced burner test reactor (ABTR) designed by Argonne. Various transient analyses are performed with this simplified ABTR model to study two fundamental issues related to system analysis codes – accuracy of numeric algorithm and efficiency. The accuracy study is carried by comparing the second order method with the first order method. The results show that numerical errors in the first order method are large and it is very difficult to distinguish numerical errors from physical modeling errors. On the other hand, second order method yields small numerical errors and it is very easy to spot physical modeling errors. The efficiency study is carried out by comparing the time steps for the fully implicit solution algorithm versus CFL stability limit methods. The dynamic time steps used in a fully implicit method will adjust the time step to resolve the time scale during the various stages of a long lasting transient. This will make a computer code based on fully implicit methods run more efficiently versus a CFL stability limit method code like RELAP, in which a particle of fluid cannot cross a control volume in a single time step.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

FY2017 Updates to the SAS4A/SASSYS-1 Safety Analysis Code

The SAS4A/SASSYS-1 safety analysis software is used to perform deterministic analysis of anticipated events as well as design-basis and beyond-design-basis accidents for advanced fast reactors. It plays a central role in the analysis of U.S. DOE conceptual designs, proposed test and demonstration reactors, and in domestic and international collaborations. This report summarizes the code development activities that have taken place during FY2017. Extensions to the void and cladding reactivity feedback models have been implemented, and Control System capabilities have been improved through a new virtual data acquisition system for plant state variables and an additional Block Signal for a variable lag compensator to represent reactivity feedback for novel shutdown devices. Current code development and maintenance needs are also summarized in three key areas: software quality assurance, modeling improvements, and maintenance of related tools. With ongoing support, SAS4A/SASSYS-1 can continue to fulfill its growing role in fast reactor safety analysis and help solidify DOE’s leadership role in fast reactor safety both domestically and in international collaborations.

97 MATHEMATICS AND COMPUTING↗

Elucidator

SAND2025-01917O Elucidator is a software tool that allows for the storage and interpretation of arbitrary metadata for use in an HPC context. It provides a flexible specification of data members uses facilities to convert buffers of information into the appropriate data types to ensure type safety. The software supports multithreading and database support. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Teves, Joshua↗

HotSpot Software Configuration Management Plan

This Software Configuration Management Plan (SCMP) describes the software configuration management procedures used to ensure that the HotSpot dispersion model meets the requirements of its user base, which includes: (1) Users of the PC version of HotSpot for consequence assessment, hazard assessment and safety analysis calculations; and (2) Users of the NARAC Web and iClient software tools, which allow users to run HotSpot for consequence assessment modeling These users and sponsors of the HotSpot software and the organizations they represent constitute the intended audience for this document. This plan is intended to meet Critical Recommendations 1 and 3 from the Software Evaluation of HotSpot and DOE Safety Software Toolbox Recommendation for inclusion of HotSpot in the Department of Energy (DOE) Safety Software Toolbox. HotSpot software is maintained for the Department of Energy Office of Emergency Operations by the National Atmospheric Release Advisory Center (NARAC) at Lawrence Livermore National Laboratory (LLNL). An overview of HotSpot and NARAC are provided.

99 GENERAL AND MISCELLANEOUS↗

HotSpot Software Test Plan

This Software Test Plan (STP) describes the procedures used to verify and validate that the HotSpot Health Physics Codes meet the requirements of its user base, which includes: (1) Users of the PC version of HotSpot conducting consequence assessment, hazard assessment and safety analysis calculations; and (2) Users of the NARAC Web and iClient software tools, which allow users to run HotSpot for consequence assessment modeling. This plan is intended to meet Critical Recommendation 2 from the Software Evaluation of HotSpot and DOE Safety Software Toolbox Recommendation for inclusion of HotSpot in the Department of Energy (DOE) Safety Software Toolbox. These users and sponsors of the HotSpot software and the organizations they represent constitute the intended audience for this document. HotSpot software is maintained for the Department of Energy Office of Emergency Operations by the National Atmospheric Release Advisory Center (NARAC) at Lawrence Livermore National Laboratory (LLNL). An overview of HotSpot and NARAC are provided.

99 GENERAL AND MISCELLANEOUS↗

The application of ICASPA to critical and safe mass calculations - 14586

ICASPA, an Improved Critical and Safe Parameters Algorithm, calculates the size of a fissile body for a given value of k-effective. ICASPA uses an iterative predictor/corrector algorithm in which the MONK9A code is used to derive a precise k-effective value for a given candidate body size; auxiliary equations are then used to adjust the body size. The process is repeated until MONK9A outputs the chosen target value of k-effective. EDF Energy operates eight nuclear power stations comprising one Pressurized Water Reactor (PWR) and seven Advanced Gas-cooled Reactor (AGR) stations. At these sites, the term 'fuel route' is used to encompass all of the ex-reactor arrangements for the handling and storage of fuel. The criticality safety cases for these fuel routes are based on the use of geometrically safe arrangements for the required quantities of fuel. The allowed quantities and arrangements of fuel are safely sub-critical, even under the contingency of accidental moderator ingress. The fuel route safety cases consider all credible potential fault conditions, including events such as dropped fuel. Any such events might change the geometry of the fuel elements, but it is difficult to calculate exact k-effective values for realistic models of dropped fuel. This difficulty is overcome by the use of an alternative approach in which limiting safe masses are calculated for bounding (worst-case) rearrangements of fuel rods and moderators, using geometries similar to those covered by criticality handbook data. Where required, the resulting safe masses are used to set safety case limits and conditions. For example, some fire extinguishants, such as water and ABC dry powder, are also effective moderators. Hence, in some fuel route areas, administrative criticality controls are used to either prohibit or limit the permitted quantities of these materials. This paper describes the work that has been carried out to adopt ICASPA as the approved calculation method for these safe mass calculations. The work has been carried out within the company quality assurance requirements for nuclear safety related software. It has involved the development of a configuration controlled version of ICASPA and the local verification and validation of the resulting code. The benefits from the adoption of ICASPA are also presented. These include accuracy improvements and, because the method uses the MONK9A code for k-effective calculations, the ability to use more sophisticated models for limiting case geometries. (authors)

42 ENGINEERING↗

CORE (Common Operating Response Environment) Software Technology Suite

Agencies that oversee complex, multi-stakeholder programs need efficient, secure ways to link people and knowledge within and across organizations. The Common Operating Response Environment (CORE), a software suite developed by PNNL researchers does just that. The CORE tool—which is customizable for a multitude of uses—facilitates situational awareness by integrating diverse data streams without the need to reformat them, summarizing that information, and providing users with the information they need to rapidly understand and appropriately respond to situations. It is mobile device-ready, has a straightforward interface for ease of use across organizations and skill sets, and is incredibly configurable to the needs of each specific user, whether they require data summaries for high-level decision makers or tactical maps, operational data, or weather information for responders in the field. Information can be input into CORE and queried in a variety of ways—using customized forms, reports, visuals, or other organizational templates—according to the needs of each user’s organization, teams, and business processes. CORE data forms, for instance, could be accessed and used in real-time to capture information about vessels being inspected for nuclear material.

42 ENGINEERING↗

NECP-Cypress: Development and Benchmarking of a 3D PWR Core-Analysis Code

As one of the key components of nuclear reactor design and safety analysis software for Pressurized Water Reactor (PWR), the advance of the core-analysis code indicates the nuclear power development of the corresponding country. Hence, Nuclear Engineering Computational Physics Lab. (NECP) developed a PWR core-analysis code NECP-Cypress. Currently, it contains several modules including a generalized cross section module, a diffusion module using the Variational Nodal Method (VNM), a depletion-calculation using the traditional macroscopic module, a thermal-hydraulics module solving the single channel heat transfer equation and 1D heat conduction equation. With the VNM employed, NECP-Cypress can eliminate the control rod cusping effect and provide a better pin power reconstruction. In this paper, we firstly introduce the modules of the code NECP-Cypress. Secondly, two large-scale PWR core benchmarks were employed to demonstrate the ability of the code by comparing with SIMULATE-3, including the BEAVRS problem and a pseudo CAP1400 reactor core problem. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Chemical Security Principles of Material Control and Accountability (MC&A) using a Chemical Inventory Management System.

Chemical Risk Management is a system or process to control safety and security risks associated with hazardous or toxic chemicals. Chemical Risk Management includes the management of both chemical safety and chemical security. There are five pillars that make up chemical security management10 (Figure 1). Each of the five pillars are key components to the implementation of a chemical security risk management system. In this paper, we will review the "Material Control and Accountability" pillar and how an academic institution can implement this principle using a chemical inventory management system.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Status of EM Pump Modeling Capability for VTR

SAS4A/SASSYS-1 is a simulation tool used to perform deterministic analyses of anticipated events as well as design basis and beyond design basis accidents for advanced liquid-metal-cooled nuclear reactors. Most recently, SAS4A/SASSYS-1 has been selected as the safety analysis software for the Versatile Test Reactor (VTR), a new materials testing Sodium Fast Reactor (SFR) to be built by the Department of Energy. In order to support analysis of the VTR, which will utilize ElectroMagnetic (EM) pumps as the primary coolant pumps, the development of new EM pump modeling capabilities has been initiated for SAS4/SASSYS-1. The new physics-based EM pump model captures systems-level transient performance based on equivalent circuit theory and is highly flexible to model a wide range of electromagnetic pumps of the three-phase linear induction type subject to changes in power supply and plant conditions. Within the equivalent circuit framework, two sub-models are developed to provide options for analysts both with and without a detailed geometric characterization of their pump such that minimal information is required to achieve a realistic working model, but specific details of a particular pump design may be captured if sufficient information is provided. In addition, heat generated from pump operation and its transport through the plant system can be modeled to better capture the behavior of certain transients. This paper will outline the model and derive the governing equations of the new EM pump model. An initial comparison between the simple EM pump model and experimental data is made. This comparison shows that the equivalent circuit model can capture pump performance, with greater accuracy near the rated conditions. In order to demonstrate the transient behavior of the new model, a simple transient with an EM pump replacing the centrifugal pumps in the Advanced Burner Test Reactor is included.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Status of EM Pump Modeling Capability for VTR

SAS4A/SASSYS-1 is a simulation tool used to perform deterministic analyses of anticipated events as well as design basis and beyond design basis accidents for advanced liquid-metal-cooled nuclear reactors. Most recently, SAS4A/SASSYS-1 has been selected as the safety analysis software for the Versatile Test Reactor (VTR), a new materials testing Sodium Fast Reactor (SFR) to be built by the Department of Energy. In order to support analysis of the VTR, which will utilize ElectroMagnetic (EM) pumps as the primary coolant pumps, the development of new EM pump modeling capabilities has been initiated for SAS4/SASSYS-1. The new physics-based EM pump model captures systems-level transient performance based on equivalent circuit theory and is highly flexible to model a wide range of electromagnetic pumps of the three-phase linear induction type subject to changes in power supply and plant conditions. Within the equivalent circuit framework, two sub-models are developed to provide options for analysts both with and without a detailed geometric characterization of their pump such that minimal information is required to achieve a realistic working model, but specific details of a particular pump design may be captured if sufficient information is provided. In addition, heat generated from pump operation and its transport through the plant system can be modeled to better capture the behavior of certain transients. This paper will outline the model and derive the governing equations of the new EM pump model. An initial comparison between the simple EM pump model and experimental data is made. This comparison shows that the equivalent circuit model can capture pump performance, with greater accuracy near the rated conditions. In order to demonstrate the transient behavior of the new model, a simple transient with an EM pump replacing the centrifugal pumps in the Advanced Burner Test Reactor is included.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Advanced Multiphysics Thermal-Hydraulics Models for the High Flux Isotope Reactor

Engineering design studies to determine the feasibility of converting the High Flux Isotope Reactor (HFIR) from using highly enriched uranium (HEU) to low-enriched uranium (LEU) fuel are ongoing at Oak Ridge National Laboratory (ORNL). This work is part of an effort sponsored by the US Department of Energy (DOE) Reactor Conversion Program. HFIR is a very high flux pressurized light-water-cooled and moderated flux-trap type research reactor. HFIR s current missions are to support neutron scattering experiments, isotope production, and materials irradiation, including neutron activation analysis. Advanced three-dimensional multiphysics models of HFIR fuel were developed in COMSOL software for safety basis (worst case) operating conditions. Several types of physics including multilayer heat conduction, conjugate heat transfer, turbulent flows (RANS model) and structural mechanics were combined and solved for HFIR s inner and outer fuel elements. Alternate design features of the new LEU fuel were evaluated using these multiphysics models. This work led to a new, preliminary reference LEU design that combines a permanent absorber in the lower unfueled region of all of the fuel plates, a burnable absorber in the inner element side plates, and a relocated and reshaped (but still radially contoured) fuel zone. Preliminary results of estimated thermal safety margins are presented. Fuel design studies and model enhancement continue.

COMSOL↗

SAS4A/SASSYS-1 VERIFICATION AND VALIDATION TEST SUITE

SAS4A/SASSYS-1 is a safety analysis software package already under copyright by Argonne National Laboratory. There is interest from third-party users of the software to gain access to our internal verification and validation test suite. Therefore we are seeking to establish copyright over the test suite, which includes input files and reference results for hundreds of test cases that demonstrate functionality of the software. Making the test suite available to licensed users allows them to utilize the broad range of tests for commercial grade dedication activities needed to qualify the SAS4A/SASSYS-1 software under their own Software Quality Assurance program for use in a regulatory environment (e.g. with the Nuclear Regulatory Commission).

FANNING, THOMAS↗

The DOE Meteorological Coordinating Council Perspective on the Application to Meteorological Software of DOE's Software Quality Assurance Requirements

Since 1994, the DOE Meteorological Coordinating Council (DMCC) has been addressing meteorological monitoring and meteorological applications program issues at U.S. Department of Energy/National Nuclear Safety Administration (DOE/NNSA) sites and providing solutions to these issues. The fundamental objectives of the DMCC include promoting cost-effective meteorological support and facilitating the use of common meteorological methods, procedures, and standards at all DOE/NNSA sites. In 2005, the DOE established strict software quality assurance (SQA) requirements for safety software, including consequence assessment software used for hazard assessments and safety analyses. These evaluations often utilize meteorological data supplied by DOE/NNSA site-based meteorological programs. However, the DOE has not established SQA guidance for this type of safety-related meteorological software. To address this gap, the DMCC is developing this guidance for the use of both public- and private-sector organizations. The goal for the DMCC is to mimic the SQA requirements for safety software but allow a much greater degree of “grading” in determining exactly what specific activities are needed. The emphasis of the DMCC SQA guidelines is on three key elements: 1) design and implementation documentation, 2) configuration management, and 3) verification and validation testing. These SQA guidelines should provide owners and users of meteorological software with a fair degree of assurance that their software is reliable, documented, and tested without putting an undue burden on meteorological system software developers.

Mazzola, Carl↗

Finite-Test-Case Development to Demonstrate Logical Integrity of Software in DRPS

Reactor protection system (RPS) in nuclear power plant (NPP) is in the process of digitalization in response to advanced features of digital systems. In this context, software integrity in the RPS becomes an important issue since it may cause common-cause failure. Therefore, to guarantee the safety of NPPs, the integrity of the software need to be properly demonstrated or assessed. There are three typical approaches for software reliability quantification: software reliability growth model (SRGM), Bayesian belief network (BBN), and test-based method. Basically, SRGM is difficult to apply to the safety-critical software because not only sufficient failure sets are unavailable but consequence of system failure is also unacceptable. Then the result obtained through the BBN model may have large uncertainty, so it produces difficulties in integrity demonstration of safety-critical software. Thus, the BBN result need to be complemented or verified by test-based method. Currently, for the integrity demonstration of safety-critical software, black-box test which feeds inputs and examines just outputs whether they succeeded or failed is considered based on trajectory-form-of-input (a series of successive values for the input variables that occur during the operation of the software over time). Usually these trajectory-inputs are randomly sampled from operational profile. In this approach, however, there are some practical difficulties. Therefore, we proposed a new test method for safety-critical software in digitalized reactor protection system (DRPS). The main contents described in this paper are about basic concepts under development of finite-test-cases by which the integrity of the software logic can be verified. It should be noted that the influence of the environments, such as operating system and other hardware, are not considered since the method focuses on software logic only. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

SU-E-T-599: Patient Safety Enhancements Through a Study of R&V System Override Data

Purpose: Record and verify (R&V) software systems include safety checks that compare actual machine parameters with prescribed values for a patient’s treatment, such as treatment couch position, linac, energy, and MUs. The therapist is warned of a mismatch with a pop-up and prompted to approve an override in order to continue without changes. Override approval is often legitimate, but the pop-up can also genuinely indicate a problem that would Result in the wrong treatment. When there are numerous pop-up warnings, human nature leads us to approve any override without careful reading, undermining the effectiveness of the safety mechanism. Methods: Override data was collected from our R&V system for all patients treated between October 8 and 29, 2012, on four linacs and entered into a spreadsheet. Additional data collected included treatment technique, disease site, immobilization, time, linac, and whether localization images were obtained. Data were analyzed using spreadsheet tools to reveal trends, patterns and associations that might suggest appropriate process changes that could decrease the total number of overrides. Results: 76 out of 113 patients had overrides. Out of the 944 treatments, 599 override items were generated. The majority were due to couch positions. 74 of the 84 overrides on a linac equipped with a 6D couch were due to the use of the rotational corrections and the fact that the 6D couch control does not communicate with the R&V system; translations required to rotate the couch appear to the R&V system as translations outside the tolerance range. Conclusion: Many findings were interesting but did not suggest a process change. Proposed process changes include creating site-specific instead of just technique-specific tolerance tables for couch shifts. Proposed improvements to the vendor are to facilitate direct communication between the 6D couch and the R&V system to eliminate those override warnings related to lack of communication.

61 RADIATION PROTECTION AND DOSIMETRY↗