Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Signature Analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Gamma/neutron analysis for SNM signatures at high-data rates(greater than 107 cps) for single-pulse active interrogation

We are developing a high data gamma/neutron spectrometer suitable for active interrogation of special nuclear materials (SNM) activated by a single burst from an intense source. We have tested the system at Naval Research Laboratory's (NRL) Mercury pulsed-power facility at distances approaching 10 meters from a depleted uranium (DU) target. We have found that the gamma-ray field in the target room 'disappears' 10 milliseconds after the x-ray flash, and that gamma ray spectroscopy will then be dominated by isomeric states/beta decay of fission products. When a polyethylene moderator is added to the DU target, a time-dependent signature of the DU is produced by thermalized neutrons. We observe this signature in gamma-spectra measured consecutively in the 0.1-1.0 ms time range. These spectra contain the Compton edge line (2.2 MeV) from capture in hydrogen, and a continuous high energy gamma-spectrum from capture or fission in minority constituents of the DU.

08 HYDROGEN↗

Genetic Analysis of the Full-Length gag Gene from the Earliest Korean Subclade B of HIV-1: An Outbreak among Korean Hemophiliacs

We determined the earliest full-length HIV-1 gag gene sequences in 110 patients with HIV-1, including 20 hemophiliacs (HPs) and 90 local controls (LCs). The gag gene from stored sera was amplified using RT-PCR, and was subjected to direct sequencing. Phylogenetic analysis indicated that 94 and 16 sequences belonged to the Korean subclade of HIV-1 subtype B (KSB) and subtype B, respectively. A total of 12 signature pattern amino acids were found within the KSB, distinct from the worldwide consensus of subtype B. Within the KSB, the gag gene sequences from donors O and P and those from the 20 HPs comprised two subclusters. In particular, sequences from donor O strongly clustered with those of eight HPs. Moreover, signature pattern analysis indicated that 14 signature nucleotides were shared between the HPs and LCs within KSB (p < 0.01). Among the 14 nucleotides, positions 9 and 5 belonged to clusters O and P, respectively. In conclusion, signature pattern analysis for the gag gene revealed 12 signature pattern residues within the KSB and also confirmed the previous conclusion that the 20 HPs were infected with viruses due to incompletely inactivated clotting factor IX. This study is the first genetic analysis of the HIV-1 gag gene in Korea.

59 BASIC BIOLOGICAL SCIENCES↗

Possible signatures of dissipation from time-series analysis techniques using a turbulent laboratory magnetohydrodynamic plasma

The frequency spectrum of magnetic fluctuations as measured on the Swarthmore Spheromak Experiment is broadband and exhibits a nearly Kolmogorov 5/3 scaling. It features a steepening region which is indicative of dissipation of magnetic fluctuation energy similar to that observed in fluid and magnetohydrodynamic turbulence systems. Two non-spectrum based time-series analysis techniques are implemented on this data set in order to seek other possible signatures of turbulent dissipation beyond just the steepening of fluctuation spectra. Presented here are results for the flatness, permutation entropy, and statistical complexity, each of which exhibits a particular character at spectral steepening scales which can then be compared to the behavior of the frequency spectrum.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A PERVASIVE BROAD COMPONENT IN H I EMISSION LINE PROFILES: TEMPERATURE, TURBULENCE, OR A HELIUM SIGNATURE?

Gaussian analysis of interstellar neutral hydrogen emission profiles has revealed a pervasive broad component with a width on the order of 34 km s{sup -1}. When present, this component can most readily be identified in high galactic latitude directions where the H I profiles are either intrinsically weak or simple. Examination of published data reveals that this characteristic line width has been found in a variety of other H I features including compact high-velocity clouds, very-high-velocity clouds, and the Magellanic Stream. When its presence is accounted for in the analysis of H I profiles, other families of line widths at 14 and 6 km s{sup -1} are clearly revealed. Possible mechanisms for producing this broad background component are discussed, including temperature, turbulence, and the critical ionization velocity effect. A line width on the order of 34 km s{sup -1} would imply a kinetic temperature of 24,000 K, too high to keep the gas neutral; hence it should not be observed in H I emission spectra. Turbulent motions could explain a pervasive broad component, but not why it always has the same numerical value in various classes of H I emission line features. The critical ionization velocity effect hypothesis is intriguing because 34 km s{sup -1} is the value for helium. Clearly, this could be a coincidence but the other prominent distribution peaks correspond to two families of critical ionization velocities of abundant interstellar elements including C, N, and O (about 14 km s{sup -1}) and metals (about 6 km s{sup -1}). Unfortunately, the mechanism by which this effect operates, even in laboratory situations, is not clearly understood. It is suggested that further investigation of the distribution of H I component line widths by allowing for the existence of a pervasive broad underlying component may cast a clearer light on this intriguing phenomenon.

74 ATOMIC AND MOLECULAR PHYSICS↗

A Monte Carlo Technique to Estimate Emissions from R&D Facilities

The Pacific Northwest National Laboratory (PNNL) operates multidisciplinary laboratory Research and Development (R&D) facilities for the U. S. Department of Energy and sampled air chemical emissions from some of these facilities from 1998 until 2008. Although sampling was not required for environmental compliance, PNNL conducted sampling to provide data to compare estimated release fractions to those used for emissions estimates and to verify that methods used to determine compliance with air regulations and permits conservatively predict actual emissions. Sampling also identifies and quantifies air toxics emitted to compare with compliance limits established by the State. The sampling data provides a unique opportunity to quantify emissions and investigate factors potentially impacting emissions. Previous work using this data set include a paper by Woodruff, Benar, and McCarthy1 who summarized the compliance approach used by PNNL and described sampling and analytical measurements for the first sampling campaigns. Conclusions reported in the paper were that none of the measurements of the target compounds exceeded a State acceptable source impact level (ASIL)2 even using significant overestimation factors, and that an average release fraction calculated from the data provided reasonable validation of the factor used in compliance assessments. Other reports using the data include the following: • A metric was developed by Ballinger, Duchsherer, and Metoyer3 to compare chemical signatures. The analysis found similarities in chemical signatures from three of the buildings but a markedly different signature from the fourth building. • A method was developed and used on the data to rank the chemical compounds that present the greatest risk to a potential downstream receptor and to determine whether the sampling parameters and detection limits provided sufficient resolution to verify compliance at potential receptor locations.4 • The stack data from one of the buildings was analyzed using a statistical technique called Positive Matrix Factorization (PMF) to identify the number and composition of major contributing sources to measured stack concentrations.5 In this analysis, a method is described that uses a Monte Carlo technique to produce a distribution of emission estimates from the measured data. The method is applied to one of the chemicals previously identified as more significant than others using the ranking process.4 Variations on the method are investigated and compared to determine their effects on the emission estimates.

Laboratory, air chemical emissions, volatile organ↗

Time-dependent behavioral data from zebrafish reveals novel signatures of chemical toxicity using point of departure analysis

High-content imaging of embryonic zebrafish behavior can be used as a screening approach to rapidly evaluate the relative potential for chemicals to cause toxicity. However, most statistical methods applied to these data so far transform movement values to incidence-based “hits” and calculate lowest effect levels (LELs), which loses individual fish resolution of behavior and defies hazard ranking due to reliance on applied dose levels. Here, we have developed and parallelized a workflow to calculate benchmark dose (BMD) values from dynamic, high-content zebrafish behavior data that scales for high-throughput chemical screening. To appropriately capture the dynamics of zebrafish response from light to dark stimulus, we summarized time-dependent data using both area under the curve and immediate change at the transition point into two novel metrics that characterized abnormal behavior as a function of chemical concentration. The BMD workflow was applied to calculate BMD 10 values of 1,060 ToxCast chemicals for 24 zebrafish endpoints, including behavior, mortality and morphology. The BMD 10 values provided better precision and separation than LELs for clustering chemicals since they were derived from models that best-fit their concentration-response curves. Clustering analysis revealed behavioral signatures as the most sensitive endpoints. High concordance in chemical activity was observed between ToxCast assays and zebrafish behavioral endpoints, however ToxPi analysis indicated that rankings based on in vitro data was not a reliable predictor of in vivo rankings for lower potency chemicals. The methods developed in this work will enable the use of high-content zebrafish behavioral screening data for BMD analysis in toxicological hazard assessment.

59 BASIC BIOLOGICAL SCIENCES↗

Rotor Magnet Fault Analysis in Permanent Magnet AC Machines Under Load Conditions - All Electric Transportation Systems

This paper studies the performance of a Permanent Magnet (PM) alternating-current (AC) machine when subjected to faults under load conditions. The effect of varying load torques, and unbalances are found to be potential causes of rotor faults, inducing physical magnet defects or broken rotor-PMs. The consequent and immediate impact on the machine quantities is observed through anomalous change in torque-speed characteristics and other vital signatures such as machine back-EMF/flux and motor current signatures (MCS). The present research study develops and illustrates a method to diagnose physical magnet defects (fault) in PMAC machines by estimating the machine torque/back-EMF constant, Ke. The constant Ke is a measure of magnet strength exhibiting the health of rotor PMs, indicative of faults. Advanced research studies and investigations are carried out to establish motor approximations and signature-based analysis as significant viable tools for diagnosing machine faults even under load conditions.

alternating current↗

Integrative epigenomic analysis reveals unique epigenetic signatures involved in unipotency of mouse female germline stem cells

Background: Germline stem cells play an essential role in establishing the fertility of an organism. Although extensively characterized, the regulatory mechanisms that govern the fundamental properties of mammalian female germline stem cells remain poorly understood. Results: We generate genome-wide profiles of the histone modifications H3K4me1, H3K27ac, H3K4me3, and H3K27me3, DNA methylation, and RNA polymerase II occupancy and perform transcriptome analysis in mouse female germline stem cells. Comparison of enhancer regions between embryonic stem cells and female germline stem cells identifies the lineage-specific enhancers involved in germline stem cell features. Additionally, our results indicate that DNA methylation primarily contributes to female germline stem cell unipotency by suppressing the somatic program and is potentially involved in maintenance of sexual identity when compared with male germline stem cells. Moreover, we demonstrate down-regulation of Prmt5 triggers differentiation and thus uncover a role for Prmt5 in maintaining the undifferentiated status of female germline stem cells. Conclusions: The genome-wide epigenetic signatures and the transcription regulators identified here provide an invaluable resource for understanding the fundamental features of mouse female germline stem cells.

59 BASIC BIOLOGICAL SCIENCES↗

Inplementation of an automated signal processing approach for the analysis of chemical spectral signatures collected from FT-IR mounted in an aircraft

The automated detection of chemical spectral signatures using a passive infrared Fourier Transform Infrared (FT-IR) Spectrometer mounted in an aircraft is a difficult challenge due to the small total infrared energy contribution of a particular chemical species compared to the background signature. The detection of spectral signatures is complicated by the fact that a large, widely varying infrared background is present that is coupled with the presence of a number of chemical interferents in the atmosphere. This paper describes a mathematical technique that has been demonstrated to automatically detect specific chemical species in an automated processing environment. The data analysis methodology has been demonstrated to be effective using data of low spectral resolution at low aircraft altitudes. An overview of the implementation and basic concepts of the approach are presented.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Feasibility of N-Gram Data-Structures for Next-Generation Pathogen Signature Design

We determined the most appropriate data structure for handling n-gram (also known as k-mer) string comparisons and storage for genomic sequence data that will scale in terms of memory and speed. This is critical to maintain LLNL as the leader in pathogen detection, as it will guide the design of the 'Next Generation' system for computational signature prediction. There are two parts to k-mer analysis for signature prediction that we investigated. First is the enumeration and frequency counting of all observed k-mers in a sequence database (k-mer is a biological term equivalent to the CS term n-gram). Second is the down-selection and pairing of k-mers to generate a signature. We determined that for the first part, suffix arrays are the preferred method to enumerate k-mers, being memory efficient and relatively easy and fast to compute. For the second part, a subset of the k-mers can be stored and manipulated in a hash, that subset determination based on desired frequency characteristics such as most/least frequent from a set, shared among sequence sets, or discriminating across sequence sets.

59 BASIC BIOLOGICAL SCIENCES↗

Extraction of O-isobutyl S-(2-diethylaminoethyl)methyl phosphothioate (Russian VX) and related chemical signatures from hot dogs and analysis by Liquid Chromatography with Detection by Mass Spectrometry (LC-MS) and Gas Chromatography with Detection by Mas

The following procedure describes the extraction of O-isobutyl S-(2- diethylaminoethyl)methyl phosphothioate (Russian VX) and related chemical signatures from hot dogs and analysis by Liquid Chromatography with Detection by Mass Spectrometry (LC-MS) and Gas Chromatography with Detection by Mass Spectrometry (GC-MS) to determine the Russian VX chemical attribution signatures present in a contaminated hot dog sample. These chemical attribution signatures may indicate the synthetic origin of the Russian VX sample.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Extraction of O-isobutyl S-(2-diethylaminoethyl)methyl phosphothioate (Russian VX) and related chemical signatures from liquid eggs and analysis by Liquid Chromatography with Detection by Mass Spectrometry (LC-MS) and Gas Chromatography with Detection by Mass Spectrometry (GC-MS)

The following procedure describes the extraction of O-isobutyl S-(2- diethylaminoethyl)methyl phosphothioate (Russian VX) and related chemical signatures from liquid eggs and analysis by Liquid Chromatography with Detection by Mass Spectrometry (LC-MS) and Gas Chromatography with Detection by Mass Spectrometry (GC-MS) to determine the Russian VX chemical attribution signatures present in a contaminated liquid egg sample. These chemical attribution signatures may indicate the synthetic origin of the Russian VX sample.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Sequence Length of HIV-1 Subtype B Increases over Time: Analysis of a Cohort of Patients with Hemophilia over 30 Years

We aimed to investigate whether the sequence length of HIV-1 increases over time. We performed a longitudinal analysis of full-length coding region sequences (FLs) during an HIV-1 outbreak among patients with hemophilia and local controls infected with the Korean subclade B of HIV-1 (KSB). Genes were amplified by overlapping RT-PCR or nested PCR and subjected to direct sequencing. Overall, 141 FLs were sequentially determined over 30 years in 62 KSB-infected patients. Phylogenetic analysis indicated that within KSB, two FLs from plasma donors O and P comprised two clusters, together with 8 and 12 patients with hemophilia, respectively. Signature pattern analysis of the KSB of HIV-1 revealed 91 signature nucleotide residues (1.1%). In total, 48 and 43 signature nucleotides originated from clusters O and P, respectively. Six positions contained 100% specific nucleotide(s) in clusters O and P. In-depth FL analysis for over 30 years indicated that the KSB FL significantly increased over time before combination antiretroviral therapy (cART) and decreased with cART. This increase occurred due to the significant increase in env and nef genes, originating in the variable regions of both genes. The increase in sequence length of HIV-1 over time suggests an evolutionary direction.

59 BASIC BIOLOGICAL SCIENCES↗

STATISTICAL ANALYSIS OF THE MAGNETIC HELICITY SIGNATURE OF THE SOLAR WIND TURBULENCE AT 1 AU

The absolute value of the magnetic helicity spectrum of the solar wind turbulence often has a peak at kinetic scales. This helicity signature is important for understanding the mechanism of the turbulent cascade. In this paper, a statistical analysis of the magnetic helicity is performed. For this purpose, a database of the solar wind intervals with the helicity signature was assembled using Wind spacecraft magnetic and plasma data. New statistically significant correlations between the magnetic helicity and the properties of the background plasma are found. The position of the signature within the spectrum depends on the proton gyroscale and the proton inertial scale. Possible mechanisms responsible for the observed trends are discussed. The helicity peak is interpreted as a result of two competing processes, one of which generates the helicity and the other one eliminates it.

79 ASTRONOMY AND ASTROPHYSICS↗

Statistical analysis of the chemical attribution signatures of 3-methylfentanyl and its methods of production

Chemical attribution of the origin of an illegal drug is a key component of forensic efforts aimed at combating illicit and clandestine manufacture of drugs and pharmaceuticals. The results of these studies yield detailed information on synthesis byproducts, reagents, and precursors that can be used to identify the method of manufacture. Here in the present work, chemical attribution signatures (CAS) associated with the synthesis of the analgesic 3-methylfentanyl, N-(3-methyl-1-phenethylpiperidin-4-yl)-N-phenylpropanamide, were investigated. Eighteen crude samples from six synthesis methods were generated, the analysis of which was used to identify signatures (i.e. chemical compounds) that were important in the discrimination of synthetic route. These methods were carefully selected to minimize the use of scheduled precursors, complicated laboratory equipment, number of steps, and extreme reaction conditions. Using gas and liquid chromatographies combined with time-of-flight mass spectrometry (GC-QTOF and LC-QTOF) over 160 distinct species were monitored. Lastly, analysis of this combined data set was performed using modern machine learning techniques capable of reducing the size of the data set, prioritizing key chemical attribution signatures, and identifying the method of production for blindly synthesized 3-methylfentanyl materials.

3-methylfentanyl↗

A low-latency graph computer to identify metastable particles at the Large Hadron Collider for real-time analysis of potential dark matter signatures

Abstract Image recognition is a pervasive task in many information-processing environments. We present a solution to a difficult pattern recognition problem that lies at the heart of experimental particle physics. Future experiments with very high-intensity beams will produce a spray of thousands of particles in each beam-target or beam-beam collision. Recognizing the trajectories of these particles as they traverse layers of electronic sensors is a massive image recognition task that has never been accomplished in real time. We present a real-time processing solution that is implemented in a commercial field-programmable gate array using high-level synthesis. It is an unsupervised learning algorithm that uses techniques of graph computing. A prime application is the low-latency analysis of dark-matter signatures involving metastable charged particles that manifest as disappearing tracks.

47 OTHER INSTRUMENTATION↗