Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Signal conditioning”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Simultaneous measurement of temperature and strain using four connecting wires

This paper describes a new signal-conditioning technique for measuring strain and temperature which uses fewer connecting wires than conventional techniques. Simultaneous measurement of temperature and strain has been achieved by using thermocouple wire to connect strain gages to signal conditioning. This signal conditioning uses a new method for demultiplexing sampled analog signals and the Anderson current loop circuit. Theory is presented along with data to confirm that strain gage resistance change is sensed without appreciable error because of thermoelectric effects. Furthermore, temperature is sensed without appreciable error because of voltage drops caused by strain gage excitation current flowing through the gage resistance.

Parker, Allen R., Jr.↗

B and F Signal Conditioner Checkout Unit

ATK Thiokol Propulsion, Test Services uses B&F Signal Conditioning units to provide excitation power and shunt calibration information to the data recording systems. Gage measurements such as force, temperature, pressure, strain, etc. are recorded using this equipment. Approximately 2500 reusable instrumentation B&F Signal Conditioning units were purchased over an interval from 1978 to 1988 at a cost of around $1000 each. Through use and over time, the relay contacts on the signal conditioning mode cards have become corroded, resulting in excessive contact resistance. This causes inaccurate and inconsistent calibration data and could jeopardize the test results. These signal conditioning cards are needed for product testing for an estimated five more years, therefore, it is necessary to develop a solution to isolate the malfunctioning units for repair. The current screening method requires Test Area technicians to check cards manually, however the connections and measurements required for this process are inefficient and time consuming. To resolve this problem, funding was approved to design and build two B&F Signal Conditioner Checkout Units. Each unit will allow technicians to test relay contact resistance on signal conditioning mode cards before they are installed for data collection procedures. This tool will allow Test Area to resolve calibration accuracy problems and extend the life of the data acquisition equipment, as well as save troubleshooting time for the technicians.

Magleby, Alyssa↗

The use of silicon microsensors in smart skins for aerodynamic research

A futuristic look at what should be pursued in terms of measurement instrumentation for aerodynamic research is presented. A cursory method is given for incorporating silicon microsensors, signal conditioning, and signal processing into a thin skin which will ultimately become the surface of an airfoil. Polyimide is the candidate material suggested for use as the skin because of its flexibility and IC processing compatibility. Specifications are given for the detection of boundary layer phenomena of current interest.

Carraway, Debra L.↗

Applications of SPICE for modeling miniaturized biomedical sensor systems

This paper proposes a model for a miniaturized signal conditioning system for biopotential and ion-selective electrode arrays. The system consists of three main components: sensors, interconnections, and signal conditioning chip. The model for this system is based on SPICE. Transmission-line based equivalent circuits are used to represent the sensors, lumped resistance-capacitance circuits describe the interconnections, and a model for the signal conditioning chip is extracted from its layout. A system for measurements of biopotentials and ionic activities can be miniaturized and optimized for cardiovascular applications based on the development of an integrated SPICE system model of its electrochemical, interconnection, and electronic components.

Microelectrodes↗

Instrument For Simulation Of Piezoelectric Transducers

Electronic instrument designed to simulate dynamic output of integrated-circuit piezoelectric acceleration or pressure transducer. Operates in conjunction with external signal-conditioning circuit, generating square-wave signal of known amplitude for use in calibrating signal-conditioning circuit. Instrument also useful as special-purpose square-wave generator in other applications.

Mcnichol, Randal S.↗

Distributed Small-Signal Stability Conditions for Inverter-Based Unbalanced Microgrids

The proliferation of inverter-based generation and advanced sensing, controls, and communication infrastructure have facilitated accelerated deployment of microgrids. A coordinated network of microgrids can maintain reliable power delivery to critical facilities during extreme events. Low-inertia offered by the power-electronics–interfaced energy resources, however, can present significant challenges to ensuring stable operation of the microgrids. In this work, distributed small-signal stability conditions for inverter-based microgrids are developed that involve the droop-controller parameters and the network parameters (e.g. line impedances, loads). The distributed closed-form parametric stability conditions derived in this paper can be verified in a computationally efficient manner, facilitating reliable design and operations of networks of microgrids. Dynamic phasor models have been used to capture the effects of electromagnetic transients. Furthermore, numerical results are presented, along with PSCAD simulations, to validate the analytical stability conditions. Effects of design choices, such as the conductor types, and inverter sizes, on the small-signal stability of inverter-based microgrids are investigated to derive useful engineering insights.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Advanced life support control/monitor instrumentation concepts for flight application

Development of regenerative Environmental Control/Life Support Systems requires instrumentation characteristics which evolve with successive development phases. As the development phase moves toward flight hardware, the system availability becomes an important design aspect which requires high reliability and maintainability. This program was directed toward instrumentation designs which incorporate features compatible with anticipated flight requirements. The first task consisted of the design, fabrication and test of a Performance Diagnostic Unit. In interfacing with a subsystem's instrumentation, the Performance Diagnostic Unit is capable of determining faulty operation and components within a subsystem, perform on-line diagnostics of what maintenance is needed and accept historical status on subsystem performance as such information is retained in the memory of a subsystem's computerized controller. The second focus was development and demonstration of analog signal conditioning concepts which reduce the weight, power, volume, cost and maintenance and improve the reliability of this key assembly of advanced life support instrumentation. The approach was to develop a generic set of signal conditioning elements or cards which can be configured to fit various subsystems. Four generic sensor signal conditioning cards were identified as being required to handle more than 90 percent of the sensors encountered in life support systems. Under company funding, these were detail designed, built and successfully tested.

Heppner, D. B.↗

Motor Controller System For Large Dynamic Range of Motor Operation

A motor controller system uses a rotary sensor with a plurality of signal conditioning units, coupled to the rotary sensor. Each of these units, which is associated with a particular range of motor output shaft rotation rates, generate a feedback signal indicative of the position of the motor s output shaft. A controller (i) converts a selected motor output shaft rotation rate to a corresponding incremental amount of rotational movement for a selected fixed time period, (ii) selects, at periodic completions of the selected fixed time period, the feedback signal from one of the signal conditioning units for which the particular range of motor output shaft rotation rates associated therewith encompasses the selected motor output shaft rotation rate, and (iii) generates a motor drive signal based on a difference between the incremental amount of rotational movement and the feedback signal from the selected one of the signal conditioning Units.

Howard, David E.↗

MMIC DHBT Common-Base Amplifier for 172 GHz

Figure 1 shows a single-stage monolithic microwave integrated circuit (MMIC) power amplifier in which the gain element is a double-heterojunction bipolar transistor (DHBT) connected in common-base configuration. This amplifier, which has been demonstrated to function well at a frequency of 172 GHz, is part of a continuing effort to develop compact, efficient amplifiers for scientific instrumentation, wide-band communication systems, and radar systems that will operate at frequencies up to and beyond 180 GHz. The transistor is fabricated from a layered structure formed by molecular beam epitaxy in the InP/InGaAs material system. A highly doped InGaAs base layer and a collector layer are fabricated from the layered structure in a triple mesa process. The transistor includes two separate emitter fingers, each having dimensions of 0.8 by 12 m. The common-base configuration was chosen for its high maximum stable gain in the frequency band of interest. The input-matching network is designed for high bandwidth. The output of the transistor is matched to a load line for maximum saturated output power under large-signal conditions, rather than being matched for maximum gain under small-signal conditions. In a test at a frequency of 172 GHz, the amplifier was found to generate an output power of 7.5 mW, with approximately 5 dB of large-signal gain (see Figure 2). Moreover, the amplifier exhibited a peak small-signal gain of 7 dB at a frequency of 176 GHz. This performance of this MMIC single-stage amplifier containing only a single transistor represents a significant advance in the state of the art, in that it rivals the 170-GHz performance of a prior MMIC three-stage, four-transistor amplifier. [The prior amplifier was reported in "MMIC HEMT Power Amplifier for 140 to 170 GHz" (NPO-30127), NASA Tech Briefs, Vol. 27, No. 11 (November 2003), page 49.] This amplifier is the first heterojunction- bipolar-transistor (HBT) amplifier built for medium power operation in this frequency band. The performance of the amplifier as measured in the aforementioned tests suggests that InP/InGaAs HBTs may be superior to high-electron-mobility (HEMT) transistors in that the HBTs may offer more gain per stage and more output power per transistor.

Paidi, Vamsi↗

Design of digital acquisition for beam current monitor

As a part of the Proton Improvement Plan – II (PIP-II) at Fermilab, instrumentation systems are being modernized to take advantage of the higher speeds and ease of use offered by standardized embedded systems like MicroTCA. A rear-transition module (RTM) is being designed to interface with said embedded systems. In each of the four identical channels on the RTM, the differential signal from an alternating-current current transformer (ACCT) transimpedance amplifier will again be amplified by a differential operation-amplifier, then filtered by a low-pass topology. The conditioned signal is then digitized at a maximum of 10MS/s by an analog to digital converter (ADC) integrated circuit. After digitization, the ADC passes the data to an off the shelf AdvancedMC (AMC) Xilinx FPGA module using low voltage differential signals. This paper will describe the simulation of analog circuitry for signal conditioning, simulation of digital signal integrity based on physical design as well as verification of design characteristics critical to signal integrity. This work aims to create a methodology that can be applied to future RTMs requiring application of high-speed digital design principles.

White, R.Turner [Fermilab]↗

Design of Digital Acquisition for Beam Current Monitor

As a part of the Proton Improvement Plan II (PIP-II) at Fermilab, instrumentation systems are being modernized to take advantage of the higher speeds and ease of use offered by standardized embedded systems like MicroTCA. A rear-transition module (RTM) is being designed to interface with said embedded systems. In each of the four identical channels on the RTM, the differential signal from an alternating-current current transformer (ACCT) transimpedance amplifier will again be amplified by a differential operation-amplifier, then filtered by a low-pass topology. The conditioned signal is then digitized at a maximum of 10MS/s by an analog to digital converter (ADC) integrated circuit. After digitization, the ADC passes the data to an off the shelf AdvancedMC (AMC) Xilinx FPGA module using low voltage differential signals. This paper will describe the simulation of analog circuitry for signal conditioning, simulation of digital signal integrity based on physical design as well as verification of design characteristics critical to signal integrity. This work aims to create a methodology that can be applied to future RTMs requiring application of high-speed digital design principles.

White, Turner [Fermilab] (ORCID:0009000348159256)↗

A modular, programmable measurement system for physiological and spaceflight applications

The NASA-Ames Sensors 2000! Program has developed a small, compact, modular, programmable, sensor signal conditioning and measurement system, initially targeted for Life Sciences Spaceflight Programs. The system consists of a twelve-slot, multi-layer, distributed function backplane, a digital microcontroller/memory subsystem, conditioned and isolated power supplies, and six application-specific, physiological signal conditioners. Each signal condition is capable of being programmed for gains, offsets, calibration and operate modes, and, in some cases, selectable outputs and functional modes. Presently, the system has the capability for measuring ECG, EMG, EEG, Temperature, Respiration, Pressure, Force, and Acceleration parameters, in physiological ranges. The measurement system makes heavy use of surface-mount packaging technology, resulting in plug in modules sized 125x55 mm. The complete 12-slot system is contained within a volume of 220x150x70mm. The system's capabilities extend well beyond the specific objectives of NASA programs. Indeed, the potential commercial uses of the technology are virtually limitless. In addition to applications in medical and biomedical sensing, the system might also be used in process control situations, in clinical or research environments, in general instrumentation systems, factory processing, or any other applications where high quality measurements are required.

Hines, John W.↗

Digitally Calibrated TR Modules Enabling Real-Time Beamforming SweepSAR Architectures

SweepSAR, a novel radar architecture that depends on a DBF (digital beamforming) array, requires calibration accuracies that are order(s) of magnitude greater than is possible with traditional techniques, such as a priori characterization of TR (transmit/receive) modules in thermal vacuum chambers, or simple loop-back of the calibration signal. The advantages of a SweepSAR architecture are so great that it is worth applying significant resources to calibration efforts. Due to the nature of the DBF, each channel contains a digitizer and very powerful digital processor. Each channel can independently digitize (with the digitizer) and analyze (with the processor) its channel's unique calibration signal, and extract the relevant calibration parameters, namely channel gain and channel phase delay commonly referred to as the gain (or amplitude) and phase of the channel. Using the processor, each channel's gain and phase can theoretically be estimated with arbitrary precision through averaging a sufficiently large number of samples. Systematic errors and the changing gain and phase of the channels, typically due to temperature drifts, limits how long the averaging can occur, which limits the precision of the calibration estimate. However, results indicate that calibration knowledge of both the transmit and receive chains of each TR module can be improved by one or two orders of magnitude. Due to the digital nature of the receiver data, the channel's gain and phase may be corrected by a similar amount, while the transmit chain can only be corrected in a traditional manner. To implement Sweep SAR, the order of magnitude improvement in the knowledge of the channel's gain and phase is needed, and the control of the receiver to a similar level is required. Inherent to the DBF array is the individual digitization of each of the array's receiver channels. Current systems typically combine all of the analog signals in the array into one or two analog channels, which are then digitized and processed. All signal conditioning performed prior to digitization is done using analog hardware (which is less precise than digital signal conditioning and dependent on temperature). The DBF digitizes every signal prior to combining, and can therefore analyze and correct received signals, as well as analyze signals that are being transmitted through analog hardware (by sampling a copy and digitizing). Each channel of a DBF also has a powerful processor. With this combination, one is able to digitize, analyze, and correct each channel prior to its being combined. A unique factor is the ability to digitize and analyze (in real time) each of the array's channels independently, allowing one to achieve unprecedented knowledge of each channel's performance (gain and phase), and since the combining is done digitally, each receive channel can be corrected prior to combining. This enables an unprecedented level of accuracy and control through onboard processing. SweepSAR promises significant increases in instrument capability for solid earth and biomass remote sensing, while reducing mission mass and cost. This new instrument concept requires new methods for calibrating the multiple channels, which must be combined onboard, in real time. New methods are being developed for digitally calibrating digital beam-forming arrays to reduce development time, risk, and cost of precision calibrated TR modules for array architectures by accurately tracking modules' characteristics through closed-loop digital calibration, thus tracking systematic changes regardless of temperature.-

Hoffman, James P.↗

Single-chip microcontrollers for switchgear control

A switchgear controller utilizing a microcontroller is described. The primary goal was to mimic the functions and performance of the generic controller board with a microcontroller board which will cause the power automation system to consume less power. The code for the microcontroller implementation on a development board has been developed, and the signal conditioning for the signals to the microcontroller has been designed and tested. The implementation of this decision system for data gathering, command control, fault detection, and circuit protection, when compared to other implementations, provides more functions and better response while reducing weight, volume, and power consumption.

Watson, Karan↗

SMART: The Future of Spaceflight Avionics

A novel avionics approach is necessary to meet the future needs of low cost space and lunar missions that require low mass and low power electronics. The current state of the art for avionics systems are centralized electronic units that perform the required spacecraft functions. These electronic units are usually custom-designed for each application and the approach compels avionics designers to have in-depth system knowledge before design can commence. The overall design, development, test and evaluation (DDT&E) cycle for this conventional approach requires long delivery times for space flight electronics and is very expensive. The Small Multi-purpose Advanced Reconfigurable Technology (SMART) concept is currently being developed to overcome the limitations of traditional avionics design. The SMART concept is based upon two multi-functional modules that can be reconfigured to drive and sense a variety of mechanical and electrical components. The SMART units are key to a distributed avionics architecture whereby the modules are located close to or right at the desired application point. The drive module, SMART-D, receives commands from the main computer and controls the spacecraft mechanisms and devices with localized feedback. The sensor module, SMART-S, is used to sense the environmental sensors and offload local limit checking from the main computer. There are numerous benefits that are realized by implementing the SMART system. Localized sensor signal conditioning electronics reduces signal loss and overall wiring mass. Localized drive electronics increase control bandwidth and minimize time lags for critical functions. These benefits in-turn reduce the main processor overhead functions. Since SMART units are standard flight qualified units, DDT&E is reduced and system design can commence much earlier in the design cycle. Increased production scale lowers individual piece part cost and using standard modules also reduces non-recurring costs. The benefit list continues, but the overall message is already evident: the SMART concept is an evolution in spacecraft avionics. SMART devices have the potential to change the design paradigm for future satellites, spacecraft and even commercial applications.

Alhorn, Dean C.↗

Wireless Temperature-Monitoring System

A relatively inexpensive instrumentation system that includes units that are connected to thermocouples and that are parts of a radio-communication network has been developed to enable monitoring of temperatures at multiple locations. Because there is no need to string wires or cables for communication, the system is well suited for monitoring temperatures at remote locations and for applications in which frequent changes of monitored or monitoring locations are needed. The system can also be adapted to monitoring of slowly varying physical quantities, other than temperature, that can be transduced by solid-state electronic sensors. The system comprises any number of transmitting units and a single receiving unit (see figure). Each transmitting unit includes connections for as many as four external thermocouples, a signal-conditioning module, a control module, and a radio-communication module. The signal- conditioning module acts as an interface between the thermocouples and the rest of the transmitting unit and includes a built-in solid ambient-temperature sensor that is in addition to the external thermocouples. The control module is a "system-on-chip" embedded processor that includes analog-to-digital converters, serial and parallel data ports, and an interface for local connection to an analog meter that is used during installation to verify correct operation. The radio-communication module contains a commercial spread-spectrum transceiver that operates in the 900-MHz industrial, scientific, and medical (ISM) frequency band. This transceiver transmits data to the receiving unit at a rate of 19,200 baud. The receiving unit includes a transceiver like that of a transmitting unit, plus a control module that contains a system-on-chip processor that includes serial data port for output to a computer that runs monitoring and/or control software, a parallel data port for output to a printer, and a seven-segment light-emitting-diode display.

Solano, Wanda↗

Wireless Temperature-Monitoring System

A relatively inexpensive instrumentation system that includes units that are connected to thermocouples and that are parts of a radio-communication network has been developed to enable monitoring of temperatures at multiple locations. Because there is no need to string wires or cables for communication, the system is well suited for monitoring temperatures at remote locations and for applications in which frequent changes of monitored or monitoring locations are needed. The system can also be adapted to monitoring of slowly varying physical quantities, other than temperature, that can be transduced by solid-state electronic sensors. electronic sensors. The system comprises any number of transmitting units and a single receiving unit. Each transmitting unit includes connections for as many as four external thermocouples, a signal-conditioning module, a control module, and a radio-communication module. The signal-conditioning module acts as an interface between the thermocouples and the rest of the transmitting unit and includes a built-in solid ambient temperature sensor that is in addition to the external thermocouples. The control module is a system-on-chip embedded processor that includes analog-to-digital converters, serial and parallel data ports, and an interface for local connection to an analog meter that is used during installation to verify correct operation. The radio-communication module contains a commercial spread-spectrum transceiver that operates in the 900-MHz industrial, scientific, and medical (ISM) frequency band. This transceiver transmits data to the receiving unit at a rate of 19,200 baud. The receiving unit includes a transceiver like that of a transmitting unit, plus a control module that contains a system-on-chip processor that includes serial data port for output to a computer that runs monitoring and/or control software, a parallel data port for output to a printer, and a seven-segment light-emitting-diode display. Each transmitting unit is battery-powered and can operate for at least seven days continuously while reporting temperatures every half hour. The receiving unit is powered by a wall-mounted transformer source. The receiving unit responds to each transmitting unit and reports the readings of each of the four thermocouples and of the ambient-temperature sensor of the transmitting unit. The end-to-end accuracy of the system is plus or minus 0.2 C over the temperature range from 0 to 100 C. The radio-communication range between the receiving and transmitting units is approximately equal to 0.5 mile (approximately equal to 0.8 km).

Solano, Wanda↗