Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SiB”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

An imaging evaluation of the simultaneously integrated boost breast radiotherapy technique

To evaluate in-field megavoltage (MV) imaging of simultaneously integrated boost (SIB) breast fields to determine its feasibility in treatment verification for the SIB breast radiotherapy technique, and to assess whether the current-imaging protocol and treatment margins are sufficient. For nine patients undergoing SIB breast radiotherapy, in-field MV images of the SIB fields were acquired on days that regular treatment verification imaging was performed. The in-field images were matched offline according to the scar wire on digitally reconstructed radiographs. The offline image correction results were then applied to a margin recipe formula to calculate safe margins that account for random and systematic uncertainties in the position of the boost volume when an offline correction protocol has been applied. After offline assessment of the acquired images, 96% were within the tolerance set in the current department-imaging protocol. Retrospectively performing the maximum position deviations on the Eclipse™ treatment planning system demonstrated that the clinical target volume (CTV) boost received a minimum dose difference of 0.4% and a maximum dose difference of 1.4% less than planned. Furthermore, applying our results to the Van Herk margin formula to ensure that 90% of patients receive 95% of the prescribed dose, the calculated CTV margins were comparable to the current departmental procedure used. Based on the in-field boost images acquired and the feasible application of these results to the margin formula the current CTV-planning target volume margins used are appropriate for the accurate treatment of the SIB boost volume without additional imaging.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Graphitic Carbon Materials for Advanced Sodium-Ion Batteries

Lithium-ion batteries (LIBs) have dominated the energy storage market for more than two decades; however, the quest for lower-cost battery alternatives is rapidly expanding, especially for large-scale applications. Sodium-ion batteries (SIBs) have recently experienced an impressive resurgence owing to the earth's abundance of sodium resources and the similar electrochemistry of SIBs and the well-established LIBs. Nonetheless, whereas cost-effective and reliable graphite anodes have served as a cornerstone in current LIB technology, one of the major limitations of SIBs has been the inability to exploit graphite as an electrode because of its negligible sodium storage capability. Recently, however, clear progress has been made in preparing high-performance graphitic carbon anodes for SIBs with new findings on the mechanisms of sodium storage. This paper aims to review the progress made in understanding the sodium storage mechanisms in graphitic carbon materials and comprehensively summarize the start-of-the-art achievements by surveying the correlations among the type of graphitic material, microstructure, sodium storage mechanisms, and electrochemical performance in SIBs. In addition, perspectives related to practical applications, including the electrolyte, coulombic efficiency, and applicability in sodium-ion full cells, are also presented.

25 ENERGY STORAGE↗

A Self‐Healing Chemistry‐Enabled Organic Cathode for Sustainable and Stable Sodium‐Ion Batteries

Sodium‐on batteries (SIBs) are promising alternatives to lithium‐ion batteries (LIBs) because of the low cost, abundance, and high sustainability of sodium resources. Analogous to LIBs, the high‐capacity electrodes in SIBs always suffer from rapid capacity decay upon long‐term cycling due to the particle pulverization induced by a large volume change. Circumventing particle pulverization plays a critical role in developing high‐energy and long‐life SIBs. Herein, tetrahydroxy‐1,4‐benzoquinone disodium salt (TBDS) that can self‐heal the cracks by hydrogen bonding between hydroxyl group and carbonyl group is employed as a cathode for sustainable and stable SIBs. The self‐healing TBDS exhibits long cycle life of 1000 cycles with a high rate capability up to 2 A g −1 due to the fast Na‐ion diffusion reaction in the TBDS cathode. The intermolecular hydrogen bonding has been comprehensively characterized to understand the self‐healing mechanism. The hydrogen bonding‐enabled self‐healing organic materials are promising for developing high‐energy and long‐cycle‐life SIBs.

25 ENERGY STORAGE↗

Simultaneous Integrated Boost Intensity-Modulated Radiotherapy in Patients With High-Grade Gliomas

Purpose: We analyzed outcomes of simultaneous integrated boost (SIB) intensity-modulated radiotherapy (IMRT) in patients with high-grade gliomas, compared with a literature review. Methods and Materials: Forty consecutive patients (WHO grade III, 14 patients; grade IV, 26 patients) treated with SIB-IMRT were analyzed. A dose of 2.0 Gy was delivered to the planning target volume with a SIB of 0.4 Gy to the gross tumor volume with a total dose of 60 Gy to the gross tumor volume and 50 Gy to the planning target volume in 25 fractions during 5 weeks. Twenty patients received temozolomide chemotherapy. Results: At a median follow-up of 13.4 months (range, 3.7-55.9 months), median survival was 14.8 months. One- and 2-year survival rates were 78% and 65%, respectively, for patients with grade III tumors and 56% and 31%, respectively, for patients with grade IV tumors. Age ({<=}50 vs. >50), grade (III vs. IV), subtype (astrocytoma vs. oligodendroglioma or mixed), and a Zubrod performance score (0-1 vs. >2) were predictive of survival. Of 25 (63%) patients who had recurrences, 17 patients had local failure, 9 patients had regional failure, and 1 patient had distant metastasis. Toxicities were acceptable. Conclusions: SIB-IMRT with the dose/fractionation used in this study is feasible and safe, with a survival outcome similar to the historical control. The shortening of treatment time by using SIB-IMRT may be of value, although further investigation is warranted to prove its survival advantage.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Esophageal Cancer Dose Escalation Using a Simultaneous Integrated Boost Technique

Purpose: We previously showed that 75% of radiation therapy (RT) failures in patients with unresectable esophageal cancer are in the gross tumor volume (GTV). We performed a planning study to evaluate if a simultaneous integrated boost (SIB) technique could selectively deliver a boost dose of radiation to the GTV in patients with esophageal cancer. Methods and Materials: Treatment plans were generated using four different approaches (two-dimensional conformal radiotherapy [2D-CRT] to 50.4 Gy, 2D-CRT to 64.8 Gy, intensity-modulated RT [IMRT] to 50.4 Gy, and SIB-IMRT to 64.8 Gy) and optimized for 10 patients with distal esophageal cancer. All plans were constructed to deliver the target dose in 28 fractions using heterogeneity corrections. Isodose distributions were evaluated for target coverage and normal tissue exposure. Results: The 50.4 Gy IMRT plan was associated with significant reductions in mean cardiac, pulmonary, and hepatic doses relative to the 50.4 Gy 2D-CRT plan. The 64.8 Gy SIB-IMRT plan produced a 28% increase in GTV dose and comparable normal tissue doses as the 50.4 Gy IMRT plan; compared with the 50.4 Gy 2D-CRT plan, the 64.8 Gy SIB-IMRT produced significant dose reductions to all critical structures (heart, lung, liver, and spinal cord). Conclusions: The use of SIB-IMRT allowed us to selectively increase the dose to the GTV, the area at highest risk of failure, while simultaneously reducing the dose to the normal heart, lung, and liver. Clinical implications warrant systematic evaluation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Understanding High-Voltage Behavior of Sodium-Ion Battery Cathode Materials Using Synchrotron X-ray and Neutron Techniques: A Review

Despite substantial research efforts in developing high-voltage sodium-ion batteries (SIBs) as high-energy-density alternatives to complement lithium-ion-based energy storage technologies, the lifetime of high-voltage SIBs is still associated with many fundamental scientific questions. In particular, the structure phase transition, oxygen loss, and cathode–electrolyte interphase (CEI) decay are intensely discussed in the field. Synchrotron X-ray and neutron scattering characterization techniques offer unique capabilities for investigating the complex structure and dynamics of high-voltage cathode behavior. In this review, to accelerate the development of stable high-voltage SIBs, we provide a comprehensive and thorough overview of the use of synchrotron X-ray and neutron scattering in studying SIB cathode materials with an emphasis on high-voltage layered transition metal oxide cathodes. We then discuss these characterizations in relation to polyanion-type cathodes, Prussian blue analogues, and organic cathode materials. Finally, future directions of these techniques in high-voltage SIB research are proposed, including CEI studies for polyanion-type cathodes and the extension of neutron scattering techniques, as well as the integration of morphology and phase characterizations.

25 ENERGY STORAGE↗

A Novel NASICON‐Type Na 4 MnCr(PO 4 ) 3 Demonstrating the Energy Density Record of Phosphate Cathodes for Sodium‐Ion Batteries

Abstract Sodium‐ion batteries (SIBs) have attracted incremental attention as a promising candidate for grid‐scale energy‐storage applications. To meet practical requirements, searching for new cathode materials with high energy density is of great importance. Herein, a novel Na superionic conductor (NASICON)‐type Na 4 MnCr(PO 4 ) 3 is developed as a high‐energy cathode for SIBs. The Na 4 MnCr(PO 4 ) 3 nanoparticles homogeneously embedded in a carbon matrix can present an extraordinary reversible capacity of 160.5 mA h g −1 with three‐electron reaction at ≈3.53 V during the Na + extraction/insertion process, realizing an unprecedentedly high energy density of 566.5 Wh kg −1 in the phosphate cathodes for SIBs. It is intriguing to reveal the underlying mechanism of the unique Mn 2+ /Mn 3+ , Mn 3+ /Mn 4+ , and Cr 3+ /Cr 4+ redox couples via X‐ray absorption near‐edge structure spectroscopy. The whole electrochemical reaction undergoes highly reversible single‐phase and biphasic transitions with a moderate volume change of 7.7% through in situ X‐ray diffraction and ex situ high‐energy synchrotron X‐ray diffraction. Combining density functional theory (DFT) calculations with the galvanostatic intermittent titration technique, the superior performance is ascribed to the low ionic‐migration energy barrier and desirable Na‐ion diffusion kinetics. The present work can offer a new insight into the design of multielectron‐reaction cathode materials for SIBs.

Zhang, Jian↗

Solvothermal-Derived S-Doped Graphene as an Anode Material for Sodium-Ion Batteries

Sodium–ion batteries (SIBs) have attracted enormous attention in recent years due to the high abundance and low cost of sodium. However, in contrast to lithium–ion batteries, conventional graphite is unsuitable for SIB anodes because it is much more difficult to intercolate the larger Na ions into graphite layers. Therefore, it is critical to develop new anode materials for SIBs for practical use. Here, heteroatom–doped graphene with high doping levels and disordered structures is prepared using a simple and economical thermal process. The solvothermal–derived graphene shows excellent performance as an anode material for SIBs. It exhibits a high reversible capacity of 380 mAh g –1 after 300 cycles at 100 mA g –1 , excellent rate performance 217 mAh g –1 at 3200 mA g –1 , and superior cycling performance at 2.0 A g –1 during 1000 cycles with negligible capacity fade.

25 ENERGY STORAGE↗

Chemical Synthesis of 3D Graphene-Like Cages for Sodium-Ion Batteries Applications

Sodium (Na) super ion conductor structured Na3V2(PO4)3 (NVP) is extensively explored as cathode material for sodium-ion batteries (SIBs) due to its large interstitial channels for Na+ migration. The synthesis of 3D graphene-like structure coated on NVP nanoflakes arrays via a one-pot, solid-state reaction in molten hydrocarbon is reported. The NVP nanoflakes are uniformly coated by the in situ generated 3D graphene-like layers with the thickness of 3 nm. As a cathode material, graphene covered NVP nanoflakes exhibit excellent electrochemical performances, including close to theoretical reversible capacity (115.2 mA h g-1 at 1 C), superior rate capability (75.9 mA h g-1 at 200 C), and excellent cyclic stability (62.5% of capacity retention over 30000 cycles at 50 C). Furthermore, the 3D graphene-like cages after removing NVP also serve as a good anode material and deliver a specific capacity of 242.5 mA h g-1 at 0.1 A g-1. The full SIB using these two cathode and anode materials delivers a high specific capacity (109.2 mA h g-1 at 0.1 A g-1) and good cycling stability (77.1% capacity retention over 200 cycles at 0.1 A g-1).

Cao, Xinxin↗

Humins-Derived Hard Carbon as a Low-Cost Material for Sodium-Ion Battery Anodes

The growing demand for sodium-ion batteries (SIBs) in grid storage underscores the need for electrode materials that balance performance and cost, including sustainable and robust carbon sources. The equitable and abundant distribution of materials for SIBs, along with their superior low-temperature performance, safety, and fast-charging capability, further distinguishes them from lithium-ion batteries (LIBs). Hard carbon (HC) is the state-of-the-art anode for SIBs, but current commercial HC production is localized mostly to one region of the world, raising concerns about supply chain vulnerability, critical material dependency, and environmental aspects. Here, the first demonstration of humins, an abundant biorefinery byproduct, as a precursor for HC anodes for sodium-ion storage is reported. Humins were carbonized at 1100 degrees C-1300 degrees C, and the resulting materials were subjected to comprehensive materials and electrochemical characterization. Among the temperatures studied, humins-derived hard carbon synthesized at 1200 degrees C delivers an initial reversible capacity 270mA h g-1 , with stable cycling performance up to 500 cycles and excellent rate capability, representing the optimal performance. This study establishes humins as a promising and low-cost carbon source that provides a route to mitigate supply chain risks and valorizes an underutilized biorefinery waste stream for high-performance SIB anodes.

25 ENERGY STORAGE↗

Toward MBenes Battery Electrode Materials: Layered Molybdenum Borides for Li-Ion Batteries

Lithium-ion and sodium-ion batteries (LIBs and SIBs) are crucial in our shift toward sustainable technologies. In this work, the potential of layered boride materials (MoAlB and Mo 2 AlB 2 ) as novel, high-performance electrode materials for LIBs and SIBs, is explored. It is discovered that Mo 2 AlB 2 shows a higher specific capacity than MoAlB when used as an electrode material for LIBs, with a specific capacity of 593 mAh g -1 achieved after 500 cycles at 200 mA g -1 . It is also found that surface redox reactions are responsible for Li storage in Mo 2 AlB 2 , instead of intercalation or conversion. Moreover, the sodium hydroxide treatment of MoAlB leads to a porous morphology and higher specific capacities exceeding that of pristine MoAlB. When tested in SIBs, Mo 2 AlB 2 exhibits a specific capacity of 150 mAh g -1 at 20 mA g -1 . These findings suggest that layered borides have potential as electrode materials for both LIBs and SIBs, and highlight the importance of surface redox reactions in Li storage mechanisms.

25 ENERGY STORAGE↗

Rationally-Designed Configuration of Directly-Coated Ni3S2/Ni Electrode by RGO Providing Superior Sodium Storage

Designing nanocomposite materials is an effective approach for enhancing the performance of sodium-ion batteries (SIBs), and understanding the synergy among components is critically important for new, better materials design. Herein, a directly reduced graphene oxide (RGO) decorated anode electrode was designed and tested for SIBs, in which uniform RGO coating onto the Ni3S2/Ni electrode was realized using facile hydrothermal reactions. The results indicate that the RGO/Ni3S2/Ni electrode delivers a high reversible specific capacity of 448.6 mAh g-1, high capacity retention of 96.5% after 100 cycles, and excellent rate capability of 263.1 mAh g-1 at 800 mA g-1. Compared with the Ni3S2/Ni electrode, the improved performance of the RGO/Ni3S2/Ni electrode benefits from RGO-promoted displacement reaction of Ni3S2 with sodium. DFT calculations reveal that the RGO layer can significantly improve the electron mobility of the RGO/Ni3S2 + Na structure, and the hybrid interaction between the C-p state of RGO and the Ni-p, Ni-d, and S-p states of Ni3S2 is the major reason for why RGO can improve the electrical transport properties.

Song, Xiaosheng↗

Intensity-Modulated Radiotherapy as Primary Therapy for Prostate Cancer: Report on Acute Toxicity After Dose Escalation With Simultaneous Integrated Boost to Intraprostatic Lesion

Purpose: To report on the acute toxicity of a third escalation level using intensity-modulated radiotherapy for prostate cancer (PCa) and the acute toxicity resulting from delivery of a simultaneous integrated boost (SIB) to an intraprostatic lesion (IPL) detected on magnetic resonance imaging (MRI), with or without spectroscopy. Methods and Materials: Between January 2002 and March 2007, we treated 230 patients with intensity-modulated radiotherapy to a third escalation level as primary therapy for prostate cancer. If an IPL (defined by MRI or MRI plus spectroscopy) was present, a SIB was delivered to the IPL. To report on acute toxicity, patients were seen weekly during treatment and 1 and 3 months after treatment. Toxicity was scored using the Radiation Therapy Oncology Group toxicity scale, supplemented by an in-house-developed scoring system. Results: The median dose to the planning target volume was 78 Gy. An IPL was found in 118 patients. The median dose to the MRI-detected IPL and MRI plus spectroscopy-detected IPL was 81 Gy and 82 Gy, respectively. No Grade 3 or 4 acute gastrointestinal toxicity developed. Grade 2 acute gastrointestinal toxicity was present in 26 patients (11%). Grade 3 genitourinary toxicity was present in 15 patients (7%), and 95 patients developed Grade 2 acute genitourinary toxicity (41%). No statistically significant increase was found in Grade 2-3 acute gastrointestinal or genitourinary toxicity after a SIB to an IPL. Conclusion: The results of our study have shown that treatment-induced acute toxicity remains low when intensity-modulated radiotherapy to 80 Gy as primary therapy for prostate cancer is used. In addition, a SIB to an IPL did not increase the severity or incidence of acute toxicity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Toxicity Assessment of Pelvic Intensity-Modulated Radiotherapy With Hypofractionated Simultaneous Integrated Boost to Prostate for Intermediate- and High-Risk Prostate Cancer

Purpose: To evaluate the toxicity of pelvic intensity-modulated radiotherapy (IMRT) with hypofractionated simultaneous integrated boost (SIB) to the prostate for patients with intermediate- to high-risk prostate cancer. Methods and Materials: A retrospective toxicity analysis was performed in 30 consecutive patients treated definitively with pelvic SIB-IMRT, all of whom also received androgen suppression. The IMRT plans were designed to deliver 70 Gy in 28 fractions (2.5 Gy/fraction) to the prostate while simultaneously delivering 50.4 Gy in 28 fractions (1.8 Gy/fraction) to the pelvic lymph nodes. The National Cancer Institute Common Terminology Criteria for Adverse Events, version 3.0, was used to score toxicity. Results: The most common acute Grade 2 events were cystitis (36.7%) and urinary frequency/urgency (26.7%). At a median follow-up of 24 months, late toxicity exceeding Grade 2 in severity was uncommon, with two Grade 3 events and one Grade 4 event. Grade 2 or greater acute bowel toxicity was associated with signficantly greater bowel volume receiving {>=}25 Gy (p = .04); Grade 2 or greater late bowel toxicity was associated with a higher bowel maximal dose (p = .04) and volume receiving {>=}50 Gy (p = .02). Acute or late bladder and rectal toxicity did not correlate with any of the dosimetric parameters examined. Conclusion: Pelvic IMRT with SIB to the prostate was well tolerated in this series, with low rates of Grade 3 or greater acute and late toxicity. SIB-IMRT combines pelvic radiotherapy and hypofractionation to the primary site and offers an accelerated approach to treating intermediate- to high-risk disease. Additional follow-up is necessary to fully define the long-term toxicity after hypofractionated, whole pelvic treatment combined with androgen suppression.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of Spatially Fractionated Radiotherapy (GRID) and Definitive Chemoradiotherapy With Curative Intent for Locally Advanced Squamous Cell Carcinoma of the Head and Neck: Initial Response Rates and Toxicity

Purpose: To present results and acute toxicity in 14 patients with bulky (>=6 cm) tumors from locally advanced squamous cell carcinoma of the head and neck who received spatially fractionated radiotherapy (GRID) therapy to the bulky mass followed by concomitant chemoradiotherapy using simultaneous integrated boost intensity-modulated radiotherapy (SIB-IMRT). Methods and Materials: GRID therapy to the GTV was delivered by creating one treatment field with a checkerboard pattern composed of open-closed areas using a multileaf collimator. The GRID prescription was 20 Gy in one fraction. Chemotherapy started the day of GRID therapy and continued throughout the course of SIB-IMRT. The SIB-IMRT prescription was 66, 60, and 54 Gy to the planning target volume (PTV), intermediate-risk PTV, and low-risk PTV, respectively, in 30 fractions. Results: With a median follow-up of 19.5 months (range, 2-38 months), the overall control rate of the GRID gross tumor volume was 79% (11 of 14). The most common acute skin and mucosal toxicities were Grade 3 and 2, respectively. Conclusion: For the treatment of locally advanced neck squamous cell carcinoma of the head and neck, GRID followed by chemotherapy and SIB-IMRT is well tolerated and yields encouraging clinical and pathologic responses, with similar acute toxicity profiles as in patients receiving chemoradiotherapy without GRID.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Impact of Gastric Filling on Radiation Dose Delivered to Gastroesophageal Junction Tumors

Purpose: This study examined the impact of gastric filling variation on target coverage of gastroesophageal junction (GEJ) tumors in three-dimensional conformal radiation therapy (3DCRT), intensity-modulated radiation therapy (IMRT), or IMRT with simultaneous integrated boost (IMRT-SIB) plans. Materials and Methods: Eight patients previously receiving radiation therapy for esophageal cancer had computed tomography (CT) datasets acquired with full stomach (FS) and empty stomach (ES). We generated treatment plans for 3DCRT, IMRT, or IMRT-SIB for each patient on the ES-CT and on the FS-CT datasets. The 3DCRT and IMRT plans were planned to 50.4 Gy to the clinical target volume (CTV), and the same for IMRT-SIB plus 63.0 Gy to the gross tumor volume (GTV). Target coverage was evaluated using dose-volume histogram data for patient treatments simulated with ES-CT sets, assuming treatment on an FS for the entire course, and vice versa. Results: FS volumes were a mean of 3.3 (range, 1.7-7.5) times greater than ES volumes. The volume of the GTV receiving >=50.4 Gy (V{sub 50.4Gy}) was 100% in all situations. The planning GTV V{sub 63Gy} became suboptimal when gastric filling varied, regardless of whether simulation was done on the ES-CT or the FS-CT set. Conclusions: Stomach filling has a negligible impact on prescribed dose delivered to the GEJ GTV, using either 3DCRT or IMRT planning. Thus, local relapses are not likely to be related to variations in gastric filling. Dose escalation for GEJ tumors with IMRT-SIB may require gastric filling monitoring.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

An Analysis of Plan Robustness for Esophageal Tumors: Comparing Volumetric Modulated Arc Therapy Plans and Spot Scanning Proton Planning

Purpose: Planning studies to compare x-ray and proton techniques and to select the most suitable technique for each patient have been hampered by the nonequivalence of several aspects of treatment planning and delivery. A fair comparison should compare similarly advanced delivery techniques from current clinical practice and also assess the robustness of each technique. The present study therefore compared volumetric modulated arc therapy (VMAT) and single-field optimization (SFO) spot scanning proton therapy plans created using a simultaneous integrated boost (SIB) for dose escalation in midesophageal cancer and analyzed the effect of setup and range uncertainties on these plans. Methods and Materials: For 21 patients, SIB plans with a physical dose prescription of 2 Gy or 2.5 Gy/fraction in 25 fractions to planning target volume (PTV){sub 50Gy} or PTV{sub 62.5Gy} (primary tumor with 0.5 cm margins) were created and evaluated for robustness to random setup errors and proton range errors. Dose–volume metrics were compared for the optimal and uncertainty plans, with P<.05 (Wilcoxon) considered significant. Results: SFO reduced the mean lung dose by 51.4% (range 35.1%-76.1%) and the mean heart dose by 40.9% (range 15.0%-57.4%) compared with VMAT. Proton plan robustness to a 3.5% range error was acceptable. For all patients, the clinical target volume D{sub 98} was 95.0% to 100.4% of the prescribed dose and gross tumor volume (GTV) D{sub 98} was 98.8% to 101%. Setup error robustness was patient anatomy dependent, and the potential minimum dose per fraction was always lower with SFO than with VMAT. The clinical target volume D{sub 98} was lower by 0.6% to 7.8% of the prescribed dose, and the GTV D{sub 98} was lower by 0.3% to 2.2% of the prescribed GTV dose. Conclusions: The SFO plans achieved significant sparing of normal tissue compared with the VMAT plans for midesophageal cancer. The target dose coverage in the SIB proton plans was less robust to random setup errors and might be unacceptable for certain patients. Robust optimization to ensure adequate target coverage of SIB proton plans might be beneficial.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Potential of porous nodal-line semi-metallic carbon for sodium-ion battery anode

As an alternative to lithium-ion batteries (LIBs), sodium-ion batteries (SIBs) have attracted much attention because sodium is abundant, cost-effective, and environmentally benign. However, due to the larger size of Na-ion compared to the Li-ion, graphite does not work well as an anode for SIBs, as it does for LIBs. In this work, based on first-principles calculations, we show that the recently proposed topological semi-metallic carbon, HZGM-42, has great potential as an anode material for SIBs. With a large capacity of 318.5 mAhg -1 , low diffusion barrier of 0.08–0.21 eV, low average open-circuit voltage of 0.43 V, and a small volume expansion of 1.85%, the all-carbon topological quantum HZGM-42 has high energy density, good rate capability, and excellent cycling stability and can serve as a universal anode material for both LIBs and SIBs.

25 ENERGY STORAGE↗