SEARCH · Engineering Papers
Results for “Short circuiting”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
An atomistic perspective on short-circuit diffusion in materials [Slides]
Interface and dislocation diffusion often control the rate of microstructural evolution during processes such as precipitation, coarsening, creep and recovery.
Impact of collector network aggregation of solar and type 4 wind farms for short circuit studies
Explore the source record for details and available documents.
Accuracy of Short Circuit Software for Vendor-Specific IBR Models with Negative Sequence Current
Explore the source record for details and available documents.
Assessing Inverter-Based Resources Modeling Gaps in Commonly Used Short-Circuit Programs
Explore the source record for details and available documents.
Modeling of Hybrid Farm in Grid Following and Grid Forming Modes for Short Circuit Studies
Explore the source record for details and available documents.
Assessing Inverter-Based Resources Modeling Gaps in Commonly Used Short-Circuit Programs
Explore the source record for details and available documents.
A comprehensive model to capture electrical discharge and spark channel evolution during spark-ignition processes
Emissions reduction through engine efficiency improvements is a priority for automakers who have turned to unconventional engine operation such as highly dilute, boosted, and stratified charge. Given its importance to flame initiation and sustained turbulent flame propagation, reliable and accurate spark ignition models are necessary to design ignition systems that reduce cyclic indicated mean effective pressure (IMEP) variability and increase engine efficiency in these operation modes. In this paper, secondary electric circuit, short-circuit, blowout, and re-strike sub-models are added to the Lagrangian-Eulerian spark ignition (LESI) model to simulate electrical discharge and spark channel elongation in an inert cross-flow combustion vessel. First, the physics of the underlying sub-models are described and the governing equations discussed with the spark channel voltage expression playing a critical role. Then, the experimental and simulations setups are presented. The results section begins with the derivation of spark channel voltage from experimental results. Then, electrical discharge and spark channel elongation simulations in inert flows are carried out using LESI and compared against experimental results. Finally, the results validate the model's ability to accurately predict spark channel elongation, as well as the occurrence of short-circuits, blowouts, re-strikes, and end of discharge.
Grid Strength Assessment for High Levels of Inverter-based Resources in the Puerto Rico Power
A system-wide assessment of the Puerto Rico power system grid strength is studied when considering high levels of inverter-based resource penetration. This study is carried out in PSSE and assesses the impact of inverter-based resource (IBR) contributions in response to three-phase ground faults. A hypothetical 100% inverter-based generation scenario is created to assess the extreme impact on short circuit levels and a realistic scenario is considered to assess the impact to short circuit ratios. The overall conclusion is that short circuit capacity and current will drastically decrease in a high IBR scenario, an effect that is quantified in this paper. The short circuit ratio metric is typically used to assess the impact of IBR but generally overestimates grid strength due to not accounting for the impact from multiple IBRs. Other methods such as equivalent circuit based short circuit ratio and weighted short circuit ratio offer a more comprehensive consideration for multiple IBRs and can better account for their mutual interactions. The work presented in this paper is part of the PR100 study.
Leveraging Structures in Fault Diagnosis for Lithium-Ion Battery Packs
Lithium-ion battery systems consist of a varying number of single cells, designed to meet specific application requirements for output voltage and capacity. Effective fault diagnosis in these battery systems is an essential prerequisite for ensuring their safe and reliable operation. To address this need, we introduce a novel model-based fault diagnosis approach that distinguishes itself by leveraging informative structures inherent in battery systems such as architecture, uniformity among the constituent cells, and sparsity of fault occurrences to enhance its fault diagnosis capabilities. The proposed approach formulates a moving horizon estimation (MHE) problem, incorporating such structural information to estimate different fault signals—specifically, internal short circuits, external short circuits, and voltage and current sensors faults. We conduct various simulations to evaluate the performance of the proposed approach under different fault types and magnitudes. The obtained results validate the proposed approach and promise effective fault diagnosis for battery systems.
Lithium-Ion Batteries with Safer Current Collectors
The US Department of Energy’s Oak Ridge National Laboratory and Soteria Battery Innovation Group collaborated to develop a metallized polymer film as a current collector for lithium-ion batteries and design slit patterns for electrodes to improve battery safety. The metallized polymer film serves as a fuse that will break under high temperature resulting from a short circuit. Consequently, the short circuit will be broken and the heat generated from the short circuit will be alleviated to avoid thermal runaway. The electrodes with slit patterns are expected to be broken into small segments upon mechanical impact, which can isolate the damaged electrodes from the rest. Thus, the heat generation associated with the mechanical impact will be reduced, along with the likelihood of thermal runaway. This effort aimed to improve lithium-ion battery safety by replacing traditional metal foils with metallized polymer films as current collector and introducing slit patterns to battery electrodes. The metallized polymer films were polyethylene terephthalate with a thin metal (aluminum for cathodes and copper for anodes) coating on both sides. Slit patterns with various geometries and dimensions were designed via simulation. Temperature distribution on cells with electrodes with and without slit patterns was also simulated via nemerical modeling. Electrodes on traditional metal foils and metallized polymer films were coated via a pilot-scale slot-die coater at the US Department of Energy Battery Manufacturing Facility at Oak Ridge National Laboratory. The electrodes were calendered to 35% porosity and punched out with and without slit patterns. Pouch cells were assembed with the electrodes inside a dry room for electrochemical and safety testing. Electrodes coated on metallized polymer films exhibited comparable electrochemical performance to their counterparts coated on traditional metal foils. They also showed improved safety in nail penetration and indentation tests.
Electrothermal Phenomena in Ferroelectrics
Physical properties of lead-zirconate-titanate (PZT) ceramics change according to the initial electric poling process and electrical boundary conditions. This paper reports the electrothermal, piezothermal, and piezoelectric coupling phenomena in ferroelectrics from thermodynamics viewpoints, in particular, thermal property differences between unpoled and poled PZT’s in the poling direction for open circuit and short circuit conditions. We propose a new terminology, “secondary electrothermal” coupling factor kλ, which is analogous to the electromechanical coupling factor k, relating the elastic compliances under short- and open-circuit conditions, in order to explain the fact that the short-circuit condition exhibited the larger thermal diffusivity than the open-circuit condition. On the other hand, the unpoled specimen exhibits the lowest thermal diffusivity. This tutorial paper was authored for providing comprehensive knowledge on equilibrium and time-dependent thermodynamics in ferroelectrics.
Data-Driven Cyber-Attack Detection for PV Farms via Time-Frequency Domain Features
The internetworking of grid-connected power electronics converters (PECs) in photovoltaic (PV) farms has inevitably expanded the cyber-attack surfaces. Here this paper presents a comprehensive study on cyber-attack detection and diagnosis for PEC-enabled PV farms via single waveform sensor to distinguish between normal conditions, open-circuit faults, short-circuit faults, and cyber-attacks. To our knowledge, this has not been attempted before. Firstly, we propose frequency-domain magnitude-based residuals to identify short-circuit faults and a time-domain mean current vector-based feature to distinguish open-circuit faults from other threats. These features can fully reflect the specific physical characteristics of PV farms during threat duration. Secondly, unlike micro phasor measurement units (µPMU) and raw electric waveform-based methods, the proposed innovative features can address novel cyber-attacks that are excluded from the training process. Thirdly, an online hardware-in-the-loop (HIL) testbed using the OPAL-RT real-time digital simulator has verified the effectiveness. The monitoring system runs in real-time while using HIL as an operational solar farm and a National Instruments (NI) data acquisition card as the electric waveform sensor at the point of coupling.
Ensuring a Nuclear Power Plant Safe State Following an EMP Event - Task 7 Deliverable: EMP Testing of Secondary Coupling to Instrumentation Cables
Sandia National Laboratories performed tests to address the potential vulnerability concerns of a coupled High-Altitude Electromagnetic Pulse (HEMP) inducing secondary coupling onto critical instrumentation and control cables in a nuclear power plant, with specific focus on early-time HEMP. Three types of receiving cables in nine configurations were tested to determine transfer functions between two electrically separated cables referenced to the common mode input current on the transmitting cable. One type of transfer function related the input short circuit current and resulting open circuit voltage on the receiving cable. The other transfer function related the input short circuit current and the resulting short circuit current on the receiving cable. A 500 A standard HEMP waveform was input into the transfer functions to calculate peak coupling values on the receiving cables. The highest level of coupling using the standard waveform occurred when cables were in direct contact, with a peak short circuit current of 85 A and open circuit voltage of 9.8 kV, while configurations with separated cables predicted coupling levels of less than 5 A or 500 V.
Frequency Stability Enhancement in a Fully Solar Power Grid: A Case Study on the Saudi Model
Recently, renewable energy sources (RES) such as solar photovoltaic (PV) have been recognized for their significant potential. Several studies have explored the issue of frequency stability with high RES penetration. A significant observation related to this issue is the decline in the weighted short circuit ratio (WSCR), which has the potential to adversely affect system stability. This research uniquely focuses on the gradual transition of the Saudi Electricity Company (SEC) system to a fully integrated solar PV grid, offering insight and methodology that can be adapted for other power systems. While a variety of mitigation methods are available, synchronous condensers (SC) were used in this study to stabilize grid frequency, and their implementation has been shown to improve the overall performance of the system. In response to the observed decline in WSCR, a comprehensive short circuit analysis was applied across all regions in the Saudi power grid model to evaluate the reduction in short circuit power and highlight areas requiring enhancement. Finally, scenarios illustrating frequency response with a gradual increase in SCR were analyzed, with the objective of establishing a stable, fully solar PV power system that is resilient to sudden power grid disturbances.
Impedance sources (Z sources) with inherent fault protection for resilient and fire-free electricity grids
Modern societies would not survive without electricity and at the same time electrical faults could cause and have caused many catastrophes—mainly deadly fires—to our societies. There are two types of electricity sources: the voltage source such as generators, charged batteries and capacitors, and the current source such as charged inductors, current-regulated rectifiers, and superconducting magnetic energy storage. An “ideal” voltage source—that is often-sought-or-intentionally engineered—generates a constant voltage irrespective of its load current, and an “ideal” current source injects a constant current irrespective of its load voltage. However, two problems exist: (1) voltage or current sources do not represent many emerging natural/renewable energy sources such as wind turbine generators, photovoltaic cells, and fuel cells, whose output voltage and current are strongly dependent on each other, and (2) a short-circuit fault to an artificially-made and controlled “ideal” voltage source or an open-circuit fault to an “ideal” current source can cause catastrophic failures of the source itself and its surrounding circuits due to large (theoretically infinite) short-circuit current or open-circuit voltage. Here we introduce an impedance source concept to represent, characterize, and model those electricity sources whose output voltage and current are strongly dependent on each other. First, we found that many electric sources with no feedback (or active) control of their output voltage and/or current are a natural impedance source with inherent fault protection at short-circuit or open-circuit faults. Second, any electrical source can be artificially controlled to mimic a natural impedance source. Finally, we show how to apply natural impedance sources and nature-mimicking artificially-controlled sources to the electricity grid—the most complex machine ever made by human beings—to realize electricity grids that are naturally stable, self-protected against electrical faults, and resilient to natural and human-made events.
Value Proposition of UV-Absorbers in PV Module Encapsulation
Various common crystalline silicon cell technologies were exposed to UVA radiation (1.24 Wm-2 nm-1 at 340 nm peak) on the front and back faces at 45 degrees Celsius for periods up to 3000 h, representing about 3 y of solar exposure in Phoenix, Arizona, USA. The resulting degradation of the open-circuit voltage and short-circuit current is presented. Of the various cell types examined, significant levels of degradation were seen in all cases. Less degradation was generally found after UV irradiation of cell fronts and older cell types, whereas a bifacial PERC type exposed on the rear showed about 25% degradation in short circuit current, attributable to lack of a diffused surface field. Selected cells were exposed to UV irradiation with the addition of long pass UV filters to replicate UV-absorbers in encapsulants. Modern cell designs are sensitive to UV-ID because of reduced or eliminated front and back surface field and increased dependence on high quality surface passivation. Single transformation of the independent variable (t, kW h/m^2) could be used to achieve a linear model of the data to extrapolate to 50 y. Solar Advisor Model (SAM) shows appropriate filtering of UV-irradiation can improve LCOE and net present value of plant. Some advanced cell types are seen to be UV-resistant (cell level solutions also exist). Solutions therefore exist on the cell, glass, and encapsulant level. Changes over time in each of these would also need to be considered (solarization, encapsulant browning...).