Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Server power”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

An Approach to Reasoning Service Migration in Data and Reasoning Fabric (DRF) Implementation

In this paper we consider service migration problem for Data and Reasoning Fabric (DRF) enabled airspace operations assuming a fixed cloud/edge infrastructure with allocated computing, storage and power resources, where cloud/edge servers, and communication stations are in a wired connected network, while vehicles use a wireless network for communication. The objective is to automatically select the best location for the requested service execution, which achieves minimum cost while satisfying the user quality of service (QoS) and available resources constraints. To this end, estimates of the response time, consumed energy and total cost are defined for each potential compute location. A mixed-integer linear program is then formulated and solved to identify optimal compute locations given QoS constraints, network infrastructure limitations, with worst-case vehicle positioning. The approach is applied to trajectory re-planning use case to avoid a collision with an emergency vehicle in real time.

Air mobility↗

Updating the Thermal Vacuum Chambers at the NASA Johnson Space Center

Chambers A and B are two large thermal vacuum chambers at Johnson Space Center which enable space simulation for unmanned and human-rated missions, respectively. With the resurgence in deep space missions for scientific research and various private commercial ventures, these chambers are expected to be used frequently for at least the next decade. For qualifying the James Webb Space Telescope, upgrades to Chamber A were performed which included the addition of a 12.5 kW refrigeration system with helium shrouds capable of simulating deep space environment and an efficient and reliable LN2 natural flow thermosiphon system for the thermal shield. Continuous improvements since then have focused on ensuring operational readiness by modernizing the data acquisition, recording, controls, and visualization systems for both chambers and clean room. These upgrades will be the focus of this paper. Controlling the Cryochambers was enhanced by moving from a 32-bit SCADA system to a 64-bit architected system. Infrastructural changes involved installing redundant power circuits, adding new servers, network switches, and including load balancing with fail-over between servers to minimize downtime. Instead of distributed servers, 3 redundant servers are used to share configurations. Configurations are now kept in a shared SQL instance making it easy to deploy and maintain. During this upgrade process many sub-systems (PLCs and NI PXI interfaces to sensors) were upgraded from the prior OPC-DA to the more secure OPC-UA protocol. Cryo-system PLCs were updated to allow Ganni cycle floating pressure calculations from any cold box to be sent to any compressor. During the project, the team recreated over 70,000 live data points, 50000 historical data points, and 4000 alarms. Finally, the graphical interfaces were upgraded to support HTML 5 in conjunction shared pages were implemented reducing the total number of webpages by over 75%. These system updates reinvigorated the previous SCADA system which had reached its end of life. The same look and feel was maintained while providing operators with an updated interface to control, troubleshoot, and record. The new system architecture is more robust and easier to maintain creating a path forward to address remaining problem points and implement additional features.

Cody Schaefer↗

Updating the Thermal Vacuum Chambers at the NASA Johnson Space Center

Chambers A and B are two large thermal vacuum chambers at Johnson Space Center which enable space simulation for unmanned and human-rated missions, respectively. With the resurgence in deep space missions for scientific research and various private commercial ventures, these chambers are expected to be used frequently for at least the next decade. For qualifying the James Webb Space Telescope, upgrades to Chamber A were performed which included the addition of a 12.5 kW refrigeration system with helium shrouds capable of simulating deep space environment and an efficient and reliable LN2 natural flow thermosiphon system for the thermal shield. Continuous improvements since then have focused on ensuring operational readiness by modernizing the data acquisition, recording, controls, and visualization systems for both chambers and clean room. These upgrades will be the focus of this paper. Controlling the Cryochambers was enhanced by moving from a 32-bit SCADA system to a 64-bit architected system. Infrastructural changes involved installing redundant power circuits, adding new servers, network switches, and including load balancing with fail-over between servers to minimize downtime. Instead of distributed servers, 3 redundant servers are used to share configurations. Configurations are now kept in a shared SQL instance making it easy to deploy and maintain. During this upgrade process many sub-systems (PLCs and NI PXI interfaces to sensors) were upgraded from the prior OPC-DA to the more secure OPC-UA protocol. Cryo-system PLCs were updated to allow Ganni cycle floating pressure calculations from any cold box to be sent to any compressor. During the project, the team recreated over 70,000 live data points, 50000 historical data points, and 4000 alarms. Finally, the graphical interfaces were upgraded to support HTML 5 in conjunction shared pages were implemented reducing the total number of webpages by over 75%. These system updates reinvigorated the previous SCADA system which had reached its end of life. The same look and feel was maintained while providing operators with an updated interface to control, troubleshoot, and record. The new system architecture is more robust and easier to maintain creating a path forward to address remaining problem points and implement additional features.

Cody Schaefer↗

High availability through full redundancy of the CMS detector controls system

The CMS detector control system (DCS) is responsible for controlling and monitoring the detector status and for the operation of all CMS sub detectors and infrastructure. This is required to ensure safe and efficient data taking so that high quality physics data can be recorded. The current system architecture is composed of more than 100 servers in order to provide the required processing resources. An optimization of the system software and hardware architecture is under development to ensure redundancy of all the controlled subsystems and to reduce any downtime due to hardware or software failures. The new optimized structure is based mainly on powerful and highly reliable blade servers and makes use of a fully redundant approach, guaranteeing high availability and reliability. The analysis of the requirements, the challenges, the improvements and the optimized system architecture as well as its specific hardware and software solutions are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The environmental footprint of data centers in the United States

Much of the world's data are stored, managed, and distributed by data centers. Data centers require a tremendous amount of energy to operate, accounting for around 1.8% of electricity use in the United States. Large amounts of water are also required to operate data centers, both directly for liquid cooling and indirectly to produce electricity. For the first time, we calculate spatially-detailed carbon and water footprints of data centers operating within the United States, which is home to around one-quarter of all data center servers globally. Our bottom-up approach reveals one-fifth of data center servers direct water footprint comes from moderately to highly water stressed watersheds, while nearly half of servers are fully or partially powered by power plants located within water stressed regions. Approximately 0.5% of total US greenhouse gas emissions are attributed to data centers. We investigate tradeoffs and synergies between data center's water and energy utilization by strategically locating data centers in areas of the country that will minimize one or more environmental footprints. Our study quantifies the environmental implications behind our data creation and storage and shows a path to decrease the environmental footprint of our increasing digital footprint.

54 ENVIRONMENTAL SCIENCES↗

NAS Parallel Benchmarks Results 3-95

The NAS Parallel Benchmarks (NPB) were developed in 1991 at NASA Ames Research Center to study the performance of parallel supercomputers. The eight benchmark problems are specified in a "pencil and paper" fashion, i.e., the complete details of the problem are given in a NAS technical document. Except for a few restrictions, benchmark implementors are free to select the language constructs and implementation techniques best suited for a particular system. In this paper, we present new NPB performance results for the following systems: (a) Parallel-Vector Processors: CRAY C90, CRAY T90 and Fujitsu VPP500; (b) Highly Parallel Processors: CRAY T3D, IBM SP2-WN (Wide Nodes), and IBM SP2-TN2 (Thin Nodes 2); and (c) Symmetric Multiprocessors: Convex Exemplar SPPIOOO, CRAY J90, DEC Alpha Server 8400 5/300, and SGI Power Challenge XL (75 MHz). We also present sustained performance per dollar for Class B LU, SP and BT benchmarks. We also mention future NAS plans for the NPB.

Saini, Subhash↗

NAS Parallel Benchmarks Results

The NAS Parallel Benchmarks (NPB) were developed in 1991 at NASA Ames Research Center to study the performance of parallel supercomputers. The eight benchmark problems are specified in a pencil and paper fashion i.e. the complete details of the problem to be solved are given in a technical document, and except for a few restrictions, benchmarkers are free to select the language constructs and implementation techniques best suited for a particular system. In this paper, we present new NPB performance results for the following systems: (a) Parallel-Vector Processors: Cray C90, Cray T'90 and Fujitsu VPP500; (b) Highly Parallel Processors: Cray T3D, IBM SP2 and IBM SP-TN2 (Thin Nodes 2); (c) Symmetric Multiprocessing Processors: Convex Exemplar SPP1000, Cray J90, DEC Alpha Server 8400 5/300, and SGI Power Challenge XL. We also present sustained performance per dollar for Class B LU, SP and BT benchmarks. We also mention NAS future plans of NPB.

Subhash, Saini↗

Energy Performance Testing of Asetek's RackCDU System at NREL's High Performance Computing Data Center

In this study, we report on the first tests of Asetek's RackCDU direct-to-chip liquid cooling system for servers at NREL's ESIF data center. The system was simple to install on the existing servers and integrated directly into the data center's existing hydronics system. The focus of this study was to explore the total cooling energy savings and potential for waste-heat recovery of this warm-water liquid cooling system. RackCDU captured up to 64% of server heat into the liquid stream at an outlet temperature of 89 degrees F, and 48% at outlet temperatures approaching 100 degrees F. This system was designed to capture heat from the CPUs only, indicating a potential for increased heat capture if memory cooling was included. Reduced temperatures inside the servers caused all fans to reduce power to the lowest possible BIOS setting, indicating further energy savings potential if additional fan control is included. Preliminary studies manually reducing fan speed (and even removing fans) validated this potential savings but could not be optimized for these working servers. The Asetek direct-to-chip liquid cooling system has been in operation with users for 16 months with no necessary maintenance and no leaks.

97 MATHEMATICS AND COMPUTING↗

Energy Efficiency in Small Server Rooms: Field Surveys and Findings

Fifty-seven percent of US servers are housed in server closets, server rooms, and localized data centers, in what are commonly referred to as small server rooms, which comprise 99percent of all server spaces in the US. While many mid-tier and enterprise-class data centers are owned by large corporations that consider energy efficiency a goal to minimize business operating costs, small server rooms typically are not similarly motivated. They are characterized by decentralized ownership and management and come in many configurations, which creates a unique set of efficiency challenges. To develop energy efficiency strategies for these spaces, we surveyed 30 small server rooms across eight institutions, and selected four of them for detailed assessments. The four rooms had Power Usage Effectiveness (PUE) values ranging from 1.5 to 2.1. Energy saving opportunities ranged from no- to low-cost measures such as raising cooling set points and better airflow management, to more involved but cost-effective measures including server consolidation and virtualization, and dedicated cooling with economizers. We found that inefficiencies mainly resulted from organizational rather than technical issues. Because of the inherent space and resource limitations, the most effective measure is to operate servers through energy-efficient cloud-based services or well-managed larger data centers, rather than server rooms. Backup power requirement, and IT and cooling efficiency should be evaluated to minimize energy waste in the server space. Utility programs are instrumental in raising awareness and spreading technical knowledge on server operation, and the implementation of energy efficiency measures in small server rooms.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Status of the CMS Detector Control System

The Compact Muon Solenoid (CMS) is a CERN multi-purpose experiment that exploits the physics of the Large Hadron Collider (LHC). The Detector Control System (DCS) is responsible for ensuring the safe, correct and efficient operation of the experiment, and has contributed to the recording of high quality physics data. The DCS is programmed to automatically react to the LHC operational mode. CMS sub-detectors bias voltages are set depending on the machine mode and particle beam conditions. An operator provided with a small set of screens supervises the system status summarized from the approximately 6M monitored parameters. Using the experience of nearly two years of operation with beam the DCS automation software has been enhanced to increase the system efficiency by minimizing the time required by sub-detectors to prepare for physics data taking. From the infrastructure point of view the DCS will be subject to extensive modifications in 2012. The current rack mounted control PCs will be replaced by a redundant pair of DELL Blade systems. These blade servers are a high-density modular solution that incorporates servers and networking into a single chassis that provides shared power, cooling and management. This infrastructure modification associated with the migration to blade servers will challenge the DCS software and hardware factorization capabilities. The on-going studies for this migration together with the latest modifications are discussed in the paper.

Bauer, Gerry↗

Power system model parameter conditioning tool

A power system model parameter conditioning tool including a server control processor in communication with phasor measurement unit monitored data records of multiple disturbance events, a model calibration unit providing event screening, power system model simulation, and simultaneous tuning of model parameters. The model calibration performing a simulation using default model parameters, the processor comparing the simulation results to the monitored data. If the prediction is within threshold, then terminating conditioning; else performing parameter identifiability analysis to determine differing effects of various model parameters on power system model accuracy, selecting a parameter set causing a degradation in power system model prediction, and updating the default model parameters corresponding to members of the parameter set with values selected to reduce the degradation. A method and a non-transitory computer readable medium are also disclosed.

Baone, Chaitanya Ashok↗

Recovery Act: Development of a Very Dense Liquid Cooled Compute Platform

The objective of this project was to design and develop a prototype very energy efficient high density compute platform with 100% pumped refrigerant liquid cooling using commodity components and high volume manufacturing techniques. Testing at SLAC has indicated that we achieved a DCIE of 0.93 against our original goal of 0.85. This number includes both cooling and power supply and was achieved employing some of the highest wattage processors available.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Chemical Inventory Management at NASA Lewis Research Center

The Chemical Management System (CMS) is a client/server application developed with Power Builder and Sybase for the Lewis Research Center (LeRC). Power Builder is a client-server application development tool, Sybase is a Relational Database Management System. The entire LeRC community can access the CMS from any desktop environment. The multiple functions and benefits of the CMS are addressed.

Kraft, Shirley S.↗

A 1kV, 480V Power Electronics Hub for DER Integration in Commercial Buildings

Power electronic (PE) systems are increasingly being integrated into distribution and sub-distribution networks in support of distributed energy resource integration (DERs), electric vehicle (EV) charging (particularly in the case of fast charging infrastructure), and improvement in power quality for high performance computing and/or servers farms. This provides an opportunity to research and develop integrated PE systems that can function as single systems thereby bringing additional functionality and benefits to the overall system. The goal of this paper is to demonstrate foundational technologies and capabilities for a multiport power electronics energy hub that can intelligently coordinate and control integrated sources and loads. The focus for this digest is on a commercial building use case which is demonstrated in hardware.

Starke, Michael↗

Shedding light on U.S. small and midsize data centers: Exploring insights from the CBECS survey

As demand for digital services accelerates, the energy and environmental footprint of data centers faces increasing scrutiny. While hyperscale cloud facilities have driven efficiency gains, small and midsize U.S. data centers remain a critical yet underexamined segment with significant untapped potential for energy savings. This study leverages data from the Commercial Buildings Energy Consumption Survey (CBECS) to analyze trends in server stocks, computing customers, cooling system adoption and efficiency, and geospatial distribution from 2012 to 2018. Findings reveal a sharp decline in small and midsize data centers, from 1.764 million to 1.398 million, with server counts dropping from 5.177 million to 4.262 million—aligning with the broader shift toward cloud computing. More than 40 % of servers in small data centers and 55 % in midsize data centers are housed in office buildings, and over half of all servers are concentrated in climate zones 5A (cold), 3A (mixed-humid), and 4A (mixed-humid), with the highest densities in metropolitan hubs. While direct expansion units remain the dominant cooling system, a clear transition toward more energy-efficient solutions, particularly air economizers, is evident. By integrating server and cooling system distributions, we estimate Power Usage Effectiveness (PUE) and Water Usage Effectiveness (WUE) for U.S. data centers by size and year. Results show that midsize data centers are more energy-efficient but more water-intensive due to the widespread use of water-cooled chillers. These findings highlight the trade-offs in cooling system selection and provide a critical foundation for policies aimed at enhancing efficiency in an evolving data center landscape.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The MolSSI QCArchive project: An open-source platform to compute, organize, and share quantum chemistry data

The Molecular Sciences Software Institute's (MolSSI) Quantum Chemistry Archive (QCArchive) project is an umbrella name that covers both a central server hosted by MolSSI for community data and the Python-based software infrastructure that powers automated computation and storage of quantum chemistry (QC) results. The MolSSI-hosted central server provides the computational molecular sciences community a location to freely access tens of millions of QC computations for machine learning, methodology assessment, force-field fitting, and more through a Python interface. Facile, user-friendly mining of the centrally archived quantum chemical data also can be achieved through web applications found at the website. The software infrastructure can be used as a standalone platform to compute, structure, and distribute hundreds of millions of QC computations for individuals or groups of researchers at any scale. The QCArchiveInfrastructure is open-source (BSD-3C), code repositories can be found at github, and releases can be downloaded via PyPI and Conda. This article is categorized under: Electronic Structure Theory > Ab Initio Electronic Structure Methods Software > Quantum Chemistry Data Science > Computer Algorithms and Programming

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Data-Analysis System for Entry, Descent, and Landing

A report describes the Entry Descent Landing Data Analysis (EDA), which is a system of signal-processing software and computer hardware for acquiring status data conveyed by multiple-frequency-shift-keying tone signals transmitted by a spacecraft during descent to the surface of a remote planet. The design of the EDA meets the challenge of processing weak, fluctuating signals that are Doppler-shifted by amounts that are only partly predictable. The software supports both real-time and post processing. The software performs fast-Fourier-transform integration, parallel frequency tracking with prediction, and mapping of detected tones to specific events. The use of backtrack and refinement parallel-processing threads helps to minimize data gaps. The design affords flexibility to enable division of a descent track into segments, within each of which the EDA is configured optimally for processing in the face of signal conditions and uncertainties. A dynamic-lock-state feature enables the detection of signals using minimum required computing power less when signals are steadily detected, more when signals fluctuate. At present, the hardware comprises eight dual-processor personal-computer modules and a server. The hardware is modular, making it possible to increase computing power by adding computers.

Pham, Timothy↗

Yahoo! Compute Coop (YCC). A Next-Generation Passive Cooling Design for Data Centers

The purpose of the Yahoo! Compute Coop (YCC) project is to research, design, build and implement a greenfield "efficient data factory" and to specifically demonstrate that the YCC concept is feasible for large facilities housing tens of thousands of heat-producing computing servers. The project scope for the Yahoo! Compute Coop technology includes: - Analyzing and implementing ways in which to drastically decrease energy consumption and waste output. - Analyzing the laws of thermodynamics and implementing naturally occurring environmental effects in order to maximize the "free-cooling" for large data center facilities. "Free cooling" is the direct usage of outside air to cool the servers vs. traditional "mechanical cooling" which is supplied by chillers or other Dx units. - Redesigning and simplifying building materials and methods. - Shortening and simplifying build-to-operate schedules while at the same time reducing initial build and operating costs. Selected for its favorable climate, the greenfield project site is located in Lockport, NY. Construction on the 9.0 MW critical load data center facility began in May 2009, with the fully operational facility deployed in September 2010. The relatively low initial build cost, compatibility with current server and network models, and the efficient use of power and water are all key features that make it a highly compatible and globally implementable design innovation for the data center industry. Yahoo! Compute Coop technology is designed to achieve 99.98% uptime availability. This integrated building design allows for free cooling 99% of the year via the building's unique shape and orientation, as well as server physical configuration.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗