Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Sensor fabrication”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Multiplexable intrinsic Fabry–Perot interferometric fiber sensors for multipoint hydrogen gas monitoring

This Letter presents an approach to produce multiplexable optical fiber chemical sensor using an intrinsic Fabry–Perot interferometer (IFPI) array via the femtosecond laser direct writing technique. Using the hydrogen-sensitive palladium (Pd) alloy as a functional sensory material, Pd alloy coated IFPI devices can reproducibly and reversibly measure hydrogen concentrations with a detection limit of 0.25% at room temperature. Seven IFPI sensors were fabricated in one fiber and performed simultaneous temperature and hydrogen measurements at seven different locations. This Letter demonstrates a simple yet effective approach to fabricate multiplexable fiber optical chemical sensors for use in harsh environments.

Cao, Rongtao↗

Laser-induced graphene gas sensors for environmental monitoring

Artemesia tridentatais a foundational plant taxon in western North America and an important medicinal plant threatened by climate change. Low-cost fabrication of sensors is critical for developing large-area sensor networks for understanding and monitoring a range of environmental conditions. However, the availability of materials and manufacturing processes is still in the early stages, limiting the capacity to develop cost-effective sensors at a large scale. In this study, we demonstrate the fabrication of low-cost flexible sensors using laser-induced graphene (LIG); a graphitic material synthesized using a 450-nm wavelength bench top laser patterned onto polyimide substrates. We demonstrate the effect of the intensity and focus of the incident beam on the morphology and electrical properties of the synthesized material. Raman analyses of the synthesized LIG show a defect-rich graphene with a crystallite size in the tens of nanometers. This shows that the high level of disorder within the LIG structure, along with the porous nature of the material provide a good surface for gas adsorption. The initial characterization of the material has shown an analyte response represented by a change in resistance of up to 5% in the presence of volatile organic compounds (VOCs) that are emitted and detected byArtemisiaspecies. Bend testing up to 100 cycles provides evidence that these sensors will remain resilient when deployed across the landscapes to assess VOC signaling in plant communities. The versatile low-cost laser writing technique highlights the promise of low-cost and scalable fabrication of LIG sensors for gas sensor monitoring.

Chemistry↗

Flow Sensor Test Article (F-STAr) (Design and Fabrication Status Report)

The Flow Sensor Test Article (F-STAr) is a test article currently under construction for the Mechanisms Engineering Test Loop (METL). F-STAr was designed to provide high sodium flowrate capabilities for sensor calibration, component testing, and fluid studies. Figure 1 shows two solid model views of the new test article. F-STAr includes a high-capacity pump that can provide a nominal flowrate of 120 GPM; a test section support structure that can accommodate a wide array of sub-test articles and their instrumentation; and finally, a heating and cooling system to aid in controlling the testing environment. Initially, F-STAr will be configured to test liquid metal flow sensors, specifically field shift sensors like the Eddy Current Flow Sensors (ECFS) based on the RDT C4-7T standard. To test these sensors, two test sections were designed that attempt to model Sodium Fast Reactor (SFR) outlet conditions. Figure 2 shows models of the “Full-Scaled Test Section” (FSTS) that represents a generic SFR fuel handling socket and a “Pseudo-Scaled Test Section” (PSTS) that represents a generic array of scaled fuel handling sockets. While F-STAr will be configured to test ECFS’s, it can also be outfitted to meet other experimental needs. For example, F-STAr could be setup with a test section that includes a fluidic diode or a component test investigating the performance of hydrodynamic bearings. Other test sections include studies of sodium thermal hydraulics like thermal striping. Overall, F-STAr is a flexible test article designed to accommodate many needs. This report will provide a status update on the design and construction of F-STAr. Manufacturing of all components has commenced, and several components have already been completed. These components include the pump and test section assembly stand. Other components, such as the heater, have been completed but were rejected due to the vendor not meeting the requirements of the purchase order. Lastly, the submersible flowmeter and main flange components are under construction, and their status will be reviewed in this report. Overall, most of the F-STAr components and parts will be completed by the end of September 2022.

42 ENGINEERING↗

Zinc Oxide–Graphene Nanocomposite-Based Sensor for the Electrochemical Determination of Cetirizine

A nanocomposite electrode of graphene (Gr) and zinc oxide (ZnO) nanoparticles was fabricated to study the electrochemical oxidation behavior of an anti-inflammatory drug, i.e., cetirizine (CET). The voltametric response of CET for bare CPE, Gr/CPE, ZnO/CPE, and the ZnO-Gr nanocomposite electrode was studied. The modifier materials were characterized using scanning electron microscopy (SEM), energy-dispersive X-ray spectroscopy (EDS), and X-ray powder diffraction (XRD) to comprehend the surface morphology of the utilized modifiers. The influence of pH, scan rate, and accumulation time on the electrooxidation of CET was examined. It was found that the electrochemical oxidation of CET was diffusion-controlled, in which two protons and two electrons participated. The detection limit was found to be 2.8 × 10 -8 M in a linearity range of 0.05–4.0 µM. Study of excipients was also performed, and it was found that they had negligible interference with the peak potential of CET. The validation and utility of the fabricated nanocomposite sensor material were examined by analyzing clinical and biological samples. Stability testing of the nanocomposite electrode was conducted to assess the reproducibility, determining that the developed biosensor has good stability and high efficiency in producing reproducible results.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Electrochemical Detection of Oxycodone and Its Main Metabolites with Nafion-Coated Single-Walled Carbon Nanotube Electrodes

Oxycodone is a strong opioid frequently used as an analgesic. Although proven efficacious in the management of moderate to severe acute pain and cancer pain, use of oxycodone imposes a risk of adverse effects such as addiction, overdose, and death. Fast and accurate determination of oxycodone blood concentration would enable personalized dosing and monitoring of the analgesic as well as quick diagnostics of possible overdose in emergency care. However, in addition to the parent drug, several metabolites are always present in the blood after a dose of oxycodone, and to date, there is no electrochemical data available on any of these metabolites. In this paper, a single-walled carbon nanotube (SWCNT) electrode and a Nafion-coated SWCNT electrode were used, for the first time, to study the electrochemical behavior of oxycodone and its two main metabolites, noroxycodone and oxymorphone. Both electrode types could selectively detect oxycodone in the presence of noroxycodone and oxymorphone. However, we have previously shown that addition of a Nafion coating on top of the SWCNT electrode is essential for direct measurements in complex biological matrices. Therefore, in this work, the Nafion/SWCNT electrode was further characterized and used for measuring clinically relevant concentrations of oxycodone in buffer solution. The limit of detection for oxycodone with the Nafion/SWCNT sensor was 85 nM, and the linear range was 0.5–10 μM in buffer solution. Furthermore, this study shows that the fabricated Nafion/SWCNT sensor has potential to be applied in clinical concentration measurements.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Neutron irradiation and electrical characterisation of the first 8” silicon pad sensor prototypes for the CMS calorimeter endcap upgrade

As part of its HL-LHC upgrade program, the CMS collaboration is replacing its existing endcap calorimeters with a high-granularity calorimeter (CE). The new calorimeter is a sampling calorimeter with unprecedented transverse and longitudinal readout for both electromagnetic and hadronic compartments. Due to its compactness, intrinsic time resolution, and radiation hardness, silicon has been chosen as active material for the regions exposed to higher radiation levels. The silicon sensors are fabricated as 20 cm (8”) wide hexagonal wafers and are segmented into several hundred pads which are read out individually. As part of the sensor qualification strategy, 8” sensor irradiation with neutrons has been conducted at the Rhode Island Nuclear Science Center (RINSC) and followed by their electrical characterisation in 2020-21. The completion of this important milestone in the CE's R&D program is documented in this paper and it provides detailed account of the associated infrastructure and procedures.The results on the electrical properties of the irradiated CE silicon sensors are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Analysis of Temperature Effects on GS-13 Short Period Sensors Utilizing Sandia's Seismic Sensor Temperature Testbed

Sandia National Laboratories has fabricated a Seismic Sensor Temperature Testbed (SSTT) suitable for exposing sensors under test to a range of reasonably stable temperatures while a co-located reference sensor is maintained at room temperature. The testbed has proven sufficiently quiet to allow recording of high-coherence signals from regional earthquakes in the passband of the seismometers, allowing a direct comparison of signals between the sensors under test and the reference sensor.

47 OTHER INSTRUMENTATION↗

Commercially Fabricated Antenna-Coupled Transition Edge Sensor Bolometer Detectors for Next-Generation Cosmic Microwave Background Polarimetry Experiment

We report on the development of commercially fabricated multi-chronic antenna-coupled transition edge sensor (TES) bolometer arrays for cosmic microwave background (CMB) polarimetry experiments. The orders of magnitude increase in detector count for next-generation CMB experiments require a new approach in detector wafer production to increase fabrication throughput. Here, we describe collaborative efforts with a commercial superconductor electronics fabrication facility (SeeQC, Inc.) to fabricate antenna-coupled TES bolometer detectors. We have successfully fabricated an operational dual-polarization, dichroic sinuous antenna-coupled TES detector array on a 150-mm-diameter wafer. The fabricated detector arrays have average yield of 95% and excellent uniformity across the wafer. Both RF characteristics and TES bolometer properties are suitable for CMB observations. We successfully fabricated different types of TES bolometers optimized for frequency multiplexing readout, time-domain multiplexing readout, and microwave SQUID multiplexing readout. We also demonstrated high production throughput. We discuss the motivation, design considerations, fabrication processes, test results, and how industrial detector fabrication could be a path to fabricate hundreds of detector wafers for future CMB polarimetry experiments.

47 OTHER INSTRUMENTATION↗

Simulation and Experimental Results of Interdigital Capacitor (IDC) Sensors to Monitor Insulation Degradation of Cables

The efficacy of using interdigital capacitor (IDC) sensors to monitor cable insulation aging was studied through electromagnetic simulations and experimental measurements. Simulation results on both planar and conformal dielectric materials indicated that IDCs on thin substrates and with conducting backplanes provide superior performance in terms of higher capacitance. An airgap study showed that even a very small airgap between the sensor and the cable’s insulation results in significant reduction in capacitance; therefore, airgaps should be minimized. Finally, cables that underwent accelerated aging exposure in an oven were tested using fabricated IDC sensors. Measurement results showed a 12.5% increase in capacitance when the IDC was pressed against the insulation versus a 91.3% increase in capacitance when the IDC was pressed against the jackets of the cables for cable specimens ranging from unaged to aged 35 days.

Cable NDE, Interdigital Capacitance↗

Enhanced ZIF-8-enabled colorimetric CO 2 sensing through dye-precursor synthesis

The accumulation of carbon dioxide (CO 2 ) within enclosed spaces, along with volatile organic compounds, under certain humidity, temperature, and ventilation conditions is associated with detrimental human health symptoms such as fatigue. Color-based chemical sensing is a promising approach to detect CO 2 levels relevant to indoor air quality through producing fast, quantifiable output visible to the naked eye. In a prior work, a colorimetric gas sensor was fabricated through synthesizing the metal-organic framework, ZIF-8, as the adsorbent, followed by post-synthetic mixing with a dye, phenol red (PSP), and primary amine, ethylenediamine (ED). While this sensor (termed PSP-ED/ZIF-8) maintained its structural integrity in atmospheric conditions and exhibited an increasing fuchsia-to-yellow color change with increasing CO 2 levels in dry environment, the colorimetric response greatly suffered in the presence of humid CO 2 . Here in this work, a significantly improved colorimetric CO 2 sensor (referred to as ED/PSP:ZIF-8) is accomplished through directly incorporating phenol red in the ZIF-8 metal and linker precursor solutions and then blending with ethylenediamine. MATLAB-generated color distributions and in-situ ultraviolet-visible (UV-Vis) spectroscopic studies quantitatively demonstrate an enhanced colorimetric gas response of ED/PSP:ZIF-8 compared to that of PSP-ED/ZIF-8 across an important range of CO 2 for indoor air quality monitoring (500 – 3500 ppm) and across a range of humidity. The new sensor also exhibits high selectivity to CO 2 compared to select volatile organic compounds, such as acetone and ethanol, which contribute to human health symptoms experienced indoors. The enhanced performance is attributed to the proposed incorporation of phenol red within ZIF-8, while maintaining the chemical stability of the MOF.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Impact of Thermal Stress on Attachment and Stability of High Temperature Strain Sensors

Static and dynamic strain sensing is required in high-temperature (HT), harsh-environments (HE) for industrial, aerospace, and energy sector applications to ensure equipment and process safety, reduce the cost of operation and maintenance, and increase process efficiency. Challenges that arise in HT HE sensing applications include device mounting, packaging, integrity, and stability to HT HE conditions. In previously reported work, static and dynamic strain surface acoustic wave resonator (SAWR) sensors were fabricated on langasite (LGS) and mounted on Inconel 625 strain beams for wireless testing up to 400°C. In this work, it has been identified that after subjecting the mounted SAWR strain sensor to thermal cycling between 100°C and 425°C, the measured sensitivity to dynamic strain decreased by 73% due to cracking at the adhesive/LGS interface, further deteriorating after additional thermal cycles. Strain modeling of the mounted LGS sensor chip up to 400°C revealed the existence of concentrated strain at the borders of the LGS chip. Microcracks caused by dicing make the chip boarders the most susceptible location for cracks to initiate when the sensor is subjected to thermal stress. In an attempt to mitigate the high strain at the LGS chip borders due to heating, adhesive shaping is proposed in this work. Simulations indicate a strain reduction of 50% at the border is achieved using both circular and triangular adhesive shapes, while also reducing the maximum strain over the entire adhesive/LGS interface by around 30%. Furthermore, the technique is thus promising for improving the integrity, reliability, and stability of static and dynamic strain sensors, particularly while operating under HT HE with several hundreddegree Celsius temperature excursions.

47 OTHER INSTRUMENTATION↗

Development of coated heat flux gauges for fast responding measurements

Thermal systems often exhibit transient behaviors that have important implications for the operation of the system and can be difficult to predict. For these reasons, experimental testing is often required to ensure system durability requirements are achieved. One important parameter governing the survivability of components in hot, high-stress environments is the heat flux into the part that dictates the temperature distribution for the component. However, sensors required to experimentally characterize heat fluxes in extreme environments must also be resilient. Here, this study presents the development of coated heat transfer gauges capable of robust, high-frequency measurements in turbine research facilities. The addition of a protective coating increases the durability of the gauge, but inherent of that coating is the attenuation of high-frequency temperature penetrations. As a result, this study first outlines the use of analytical solutions to define a gauge design for a specific frequency range and heat transfer, ensuring that subsurface signals can be rectified to surface conditions through inverse methods. Then, the fabrication of polyimide substrate sensors with a parylene-F coating is described. Micro surface heaters added to the custom sensors were used to determine important geometric and thermal properties necessary to calculate accurate surface heat flux. Ultimately, this work shows increased sensor robustness in a turbine test bed and experimentally validates that the frequency response of the fabricated sensors meet the design intent.

47 OTHER INSTRUMENTATION↗

Poly(lactic acid)-Based Ink for Biodegradable Printed Electronics With Conductivity Enhanced through Solvent Aging

Biodegradable electronics is a rapidly growing field, and the development of controllably biodegradable, high-conductivity materials suitable for additive manufacturing under ambient conditions remains a challenge. Here, printable conductive pastes that employ poly(lactic acid) (PLA) as a binder and tungsten as a conductor are demonstrated. These composite conductors can provide enhanced stability in applications where moisture may be present, such as environmental monitoring or agriculture. Post-processing the printed traces using a solvent-aging technique increases their conductivity by up to 2 orders of magnitude, with final conductivities approaching 5000 S/m. Such techniques could prove useful when thermal processes including heating or laser sintering are limited by the temperature constraints of typical biodegradable substrates. Finally, both accelerated oxidative and hydrolytic degradation of the printed composite conductors are examined, and a fully biodegradable capacitive soil moisture sensor is fabricated and tested.

36 MATERIALS SCIENCE↗

Low-cost sensor-based damage localization for large-area monitoring of FRP composites

Abstract In recent years, there has been growing interest in self-sensing structural materials across research and industry sectors. Detecting and locating structural damage typically requires numerous sensors wired to a data acquisition (DAQ) circuit, rendering implementation impractical in real structures. This paper proposes an innovative, cost-effective sensor network for damage detection and localization in fiber-reinforced polymer composites. The innovation encompasses three key elements: (1) utilizing carbon fiber tows within the composite as piezoresistive sensors, eliminating the need for additional foreign sensor devices; (2) introducing a novel sensor layout wherein sensor tow branches with varied resistance values are connected in parallel, reducing the number of connections to the DAQ circuit and cutting manufacturing costs significantly; (3) developing a practical sensor terminal fabrication technique to minimize manufacturing expenses. The proposed design methodology for the branch resistance values is first validated using a demonstration panel. Subsequently, the overall strategy is assessed by conducting impact tests on carbon and glass fiber-reinforced composite specimens. Results validate the sensor’s ability to accurately detect and locate structural damage.

Demo, Luke B. (ORCID:0000000208806522)↗

Surface-Mediated Interconnections of Nanoparticles in Cellulosic Fibrous Materials toward 3D Sensors

Fibrous materials serve as an intriguing class of 3D materials to meet the growing demands for flexible, foldable, biocompatible, biodegradable, dis- posable, inexpensive, and wearable sensors and the rising desires for higher sensitivity, greater miniaturization, lower cost, and better wearability. The use of such materials for the creation of a fibrous sensor substrate that interfaces with a sensing film in 3D with the transducing electronics is however difficult by conventional photolithographic methods. Here, a highly effective pathway featuring surface-mediated interconnection (SMI) of metal nanoclusters (NCs) and nanoparticles (NPs) in fibrous materials at ambient conditions is demon- strated for fabricating fibrous sensor substrates or platforms. Bimodally distrib- uted gold–copper alloy NCs and NPs are used as a model system to demonstrate the semiconductive-to-metallic conductivity transition, quantized capacitive charging, and anisotropic conductivity characteristics. Upon coupling SMI of NCs/NPs as electrically conductive microelectrodes and surface-mediated assembly (SMA) of the NCs/NPs as chemically sensitive interfaces, the resulting fibrous chemiresistors function as sensitive and selective sensors for gaseous and vaporous analytes. Finally, this new SMI–SMA strategy has significant implications for manufacturing high-performance fibrous platforms to meet the growing demands of the advanced multifunctional sensors and biosensors.

36 MATERIALS SCIENCE↗

Fabrication of bulk alumina structures with humidity sensing capabilities using direct ink write technique

Purpose The purpose of this study is to evaluate different 3D structures for humidity sensing that will enable the fabrication of complex geometries with high moisture sensitivity. Design/methodology/approach Humidity sensors based on alumina ceramics were fabricated using direct ink write (DIW) technique. Different engineered surface area, polymer binder ratio and post-processing treatment were considered to increase moisture sensitivity. Findings It was found that the binder ratio plays an important role in controlling the rheology of the paste during printing and determining the pore size after post-processing treatment. The sensibility of the fabricated humidity sensor was investigated by measuring its capacitance response toward relative humidity (RH) varying from 40% to 90% RH at 25°C. It is shown that using 3D lattice design, printed alumina humidity sensor could improve sensitivity up to 31.6 pF/RH%, over an order of magnitude higher than solid alumina. Originality/value Most of the alumina humidity sensors available are films in nature because of manufacturing difficulties, which limited its potential of higher sensitivity, and thus broader applications. In this paper, a novel 3D alumina humidity sensor was fabricated using DIW 3D printing technology.

Engineering↗

Additively manufactured strain sensors for in-pile applications

Accurate, real-time monitoring of strain in fuel, cladding, and structural components of nuclear reactors is critical to better understand radiation induced phenomena during reactor tests and operations. The data provided is crucial to verify physics-based, multiscale modeling and simulation efforts, which aim to shorten the timeline for the development of new nuclear materials. Resistive strain gauges have limited performance during in-pile experiments due to the harsh operating conditions and limited physical space between fuel and cladding components. In this work, aerosol jet printing using silver nanoparticle inks was used to fabricate interdigitated electrode capacitive strain gauges on aluminum alloy 6061 tensile specimens. Here to simulate the temperatures of a traditional light water reactor, the capacitive strain gauges were tested with a mechanical test frame up to 300 °C and compared to commercially available bondable resistive strain gauges. The printed capacitive strain gauges exhibited a gauge factor of 1.0 and showed higher reproducibility and predictability of strain sensing performance than the resistive strain gauge. The results demonstrate the potential of aerosol jet printing to fabricate strain sensors with predictable performance and reduced invasiveness for high-temperature applications with confined spacing.

36 MATERIALS SCIENCE↗

Paper-based gold nanoparticles decorated SWCNTs chemiresistive sensor for sensitive detection of As(III) based on electrochemical doping

A paper-based chemiresistive sensor consisting of a single-walled carbon nanotubes network with electrodeposited gold nanoparticles (AuNPs-SWCNTs) was developed for the sensitive detection of As(III). A new sensing strategy was also proposed combined with a paper-based device for As(III) chemiresistive detection based on the electrochemical doping of As(0) on the AuNPs-SWCNTs channel. Here, the proposed paper-based chemiresistive sensor was manufactured by wax printing and vacuum deposition using a water-based SWCNTs ink. The sensor sensitivity was enhanced by optimizing the volume of SWCNTs ink used in the formation of the sensing network in the paper and the sweep segment of cyclic voltammetry used for the electrochemical deposition of AuNPs. Additionally, the mechanism of the sensing strategy based on the electrochemical n-doping of As(0) to the AuNPs-SWCNTs sensing channel was investigated using a liquid-ion gated FET system. The As(III) concentration detected by the as-fabricated chemiresistive sensor is as low as 1.35 × 10 -5 μM which is even lower than the maximum permissible concentration in drinking water defined by the WHO. In this paper, we provide a simple strategy for developing paper-based chemiresistive sensors with unique properties for practical As(III) determination.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗