Computerized optimal control system design for reusable and expendable boost vehicles.

An optimization technique has been developed which combines the practical features of hybrid simulation of the dynamic system under study with the systematic approach of modern control theory where a mathematically formulated design criterion is optimized by functional minimization. Standard hybrid computer optimization methods using high-speed repetitive simulations and gradient minimization schemes have been extended to obtain time-varying optimal gain schedules and reduce the sensitivity of the optimized system to parameter and disturbance uncertainties. In this approach the performance index is expressed in meaningful engineering terms that reflect the interactions among all major disciplines, structures, control/actuation system design, aerodynamics and performance. The basic optimization technique is developed and its application to current aerospace control problems including the space shuttle is presented in detail. In the discussion of the application, the controllers resulting from the technique are compared with controllers developed by conventional methods. The paper concludes with a review of the advantages and disadvantages of the technique and plans for future applications.

Connor, C. L.↗

Radiative transfer in shrub savanna sites in Niger: Preliminary results from HAPEX-Sahel. Part 3: Optical dynamics and vegetation index sensitivity to biomass and plant cover

A shrub savannah landscape in Niger was optically characterized utilizing blue, green, red and near-infrared wavelengths. Selected vegetation indices were evaluated for their performance and sensitivity to describe the complex Sahelian soil/vegetation canopies. Bidirectional reflectance factors (BRF) of plants and soils were measured at several view angles, and used as input to various vegetation indices. Both soil and vegetation targets had strong anisotropic reflectance properties, rendering all vegetation index (6) responses to be a direct function of sun and view geometry. Soil background influences were shown to alter the response of most vegetation indices. N-space greenness had the smallest dynamic range in VI response, but the n-space brightness index provided additional useful information. The global environmental monitoring index (GEMI) showed a large 6 dynamic range for bare soils, which was undesirable for a vegetation index. The view angle response of the normalized difference vegetation index (NDVI), atmosphere resistant vegetation index (ARVI) and soil atmosphere resistant vegetation index (SARVI) were asymmetric about nadir for multiple view angles, and were, except for the SARVI, altered seriously by soil moisture and/or soil brightness effects. The soil adjusted vegetation index (SAVI) was least affected by surface soil moisture and was symmetric about nadir for grass vegetation covers. Overall the SAVI, SARVI and the n-space vegetation index performed best under all adverse conditions and were recommended to monitor vegetation growth in the sparsely vegetated Sahelian zone.

vanLeeuwen, W. J. D.↗

The value of assessing pulmonary venous flow velocity for predicting severity of mitral regurgitation: A quantitative assessment integrating left ventricular function

Although alteration in pulmonary venous flow has been reported to relate to mitral regurgitant severity, it is also known to vary with left ventricular (LV) systolic and diastolic dysfunction. There are few data relating pulmonary venous flow to quantitative indexes of mitral regurgitation (MR). The object of this study was to assess quantitatively the accuracy of pulmonary venous flow for predicting MR severity by using transesophageal echocardiographic measurement in patients with variable LV dysfunction. This study consisted of 73 patients undergoing heart surgery with mild to severe MR. Regurgitant orifice area (ROA), regurgitant stroke volume (RSV), and regurgitant fraction (RF) were obtained by quantitative transesophageal echocardiography and proximal isovelocity surface area. Both left and right upper pulmonary venous flow velocities were recorded and their patterns classified by the ratio of systolic to diastolic velocity: normal (>/=1), blunted (<1), and systolic reversal (<0). Twenty-three percent of patients had discordant patterns between the left and right veins. When the most abnormal patterns either in the left or right vein were used for analysis, the ratio of peak systolic to diastolic flow velocity was negatively correlated with ROA (r = -0.74, P <.001), RSV (r = -0.70, P <.001), and RF (r = -0.66, P <.001) calculated by the Doppler thermodilution method; values were r = -0.70, r = -0.67, and r = -0.57, respectively (all P <.001), for indexes calculated by the proximal isovelocity surface area method. The sensitivity, specificity, and predictive values of the reversed pulmonary venous flow pattern for detecting a large ROA (>0.3 cm(2)) were 69%, 98%, and 97%, respectively. The sensitivity, specificity, and predictive values of the normal pulmonary venous flow pattern for detecting a small ROA (<0.3 cm(2)) were 60%, 96%, and 94%, respectively. However, the blunted pattern had low sensitivity (22%), specificity (61%), and predictive values (30%) for detecting ROA of greater than 0.3 cm(2) with significant overlap with the reversed and normal patterns. Among patients with the blunted pattern, the correlation between the systolic to diastolic velocity ratio was worse in those with LV dysfunction (ejection fraction <50%, r = 0.23, P >.05) than in those with normal LV function (r = -0.57, P <.05). Stepwise linear regression analysis showed that the peak systolic to diastolic velocity ratio was independently correlated with RF (P <.001) and effective stroke volume (P <.01), with a multiple correlation coefficient of 0.71 (P <.001). In conclusion, reversed pulmonary venous flow in systole is a highly specific and reliable marker of moderately severe or severe MR with an ROA greater than 0.3 cm(2), whereas the normal pattern accurately predicts mild to moderate MR. Blunted pulmonary venous flow can be seen in all grades of MR with low predictive value for severity of MR, especially in the presence of LV dysfunction. The blunted pulmonary venous flow pattern must therefore be interpreted cautiously in clinical practice as a marker for severity of MR.

Non-NASA Center↗

Cryogenic Refractive Index of Heraeus Homosil Glass

This paper reports measurements of the refractive index of Homosil (Heraeus) over the wavelength range of 0.343.16 m and temperature range of 120335 K. These measurements were performed by using the Cryogenic High Accuracy Refraction Measuring System (CHARMS) facility at the NASAs Goddard Space Flight Center. These measurements were in support of an integrated Structural-Thermal-Optical-Performance (STOP) model that was developed for a field-widened Michelson interferometer that is being built and tested for the High Spectral Resolution Lidar (HSRL) project at the NASA Langley Research Center (LaRC). The cryogenic refractive index measurements were required in order to account for the highly sensitivity performance of the HSRL instrument to changes in refractive index with temperature, temperature gradients, thermal expansion, and deformation due to mounting stresses. A dense coverage of the absolute refractive index over the aforementioned wavelength and temperature ranges was used to determine the thermo-optic coefficient (dndT) and dispersion relation (dnd) as a function of wavelength and temperature. Our measurements of Homosil will be compared with measurements of other glasses from the fused silica family studied in CHARMS as well as measurements reported elsewhere in literature.

Homosil↗

Cryogenic Refractive Index of Heraeus Homosil Glass

This paper reports measurements of the refractive index of Homosil (Heraeus) over the wavelength range of 0.34-3.16 microns and temperature range of 120-335 K. These measurements were performed by using the Cryogenic High Accuracy Refraction Measuring System (CHARMS) facility at the NASAs Goddard Space Flight Center. These measurements were in support of an integrated Structural-Thermal-Optical-Performance (STOP) model that was developed for a field-widened Michelson interferometer that is being built and tested for the High Spectral Resolution Lidar (HSRL) project at the NASA Langley Research Center (LaRC). The cryogenic refractive index measurements were required in order to account for the highly sensitivity performance of the HSRL instrument to changes in refractive index with temperature, temperature gradients, thermal expansion, and deformation due to mounting stresses. A dense coverage of the absolute refractive index over the aforementioned wavelength and temperature ranges was used to determine the thermo-optic coefficient (dn/dT) and dispersion relation (dn/d(lamda)) as a function of wavelength and temperature. Our measurements of Homosil will be compared with measurements of other glasses from the fused silica family studied in CHARMS as well as measurements reported elsewhere in literature.

cryogenic↗

Photometry and polarimetry of Titan - Pioneer 11 observations and their implications for aerosol properties

Pioneer 11 measurements of Titan's limb darkening and polarization at red and blue wavelengths are refined, and the integrated disk brightness measurements at phase angles from 22 to 96 deg, over which Titan's phase coefficient averages about 0.014 magnitudes/deg in both colors, are reduced. Comparisons of the data with vertically homogeneous multiple scattering models indicate that the single-scattering phase functions of the aerosols in both colors are flat at scattering angles between 80 and 150 deg, with a small peak at larger scattering angles. Although a vertically homogeneous model in which particles are assumed to scatter as spheres cannot simultaneously match the polarization observations of both colors for any refractive index, observed polarizations are most sensitive to the particle properties near optical depth 1/2 in each color. Models based on single scattering by spheres can therefore be successful over a range of refractive indices, if the size of the particles increases with depth and if the cross section of the particles increases sufficiently rapidly with decreasing wavelength.

Tomasko, M. G.↗

On the numerical performance of three-dimensional thick shell elements using a hybrid/mixed formulation

Three-dimensional thick shell elements with 8, 16, and 18 nodes are formulated by using the hybrid/mixed method. In bending applications, these elements are free from locking effect and give improved stress predictions. Finite element equations are derived from the Hellinger-Reissner variational principle in which both the displacement and stress fields are approximated by independent interpolation functions. For the assumption of stress parameters, three guidelines are followed: (1) suppression of kinematic deformation modes, (2) invariant element property, and (3) the constraint index exhibited by the element, when applied to constrained-media problems, must be greater than or equal to one. Numerical results are presented to show the element's behavior characteristics regarding sensitivity to locking, distortion effect (patch tests), mesh convergence and the accuracy of stress evaluation.

Graf, W.↗

The Fast Radio Burst Luminosity Function and Death Line in the Low-Twist Magnetar Model

We explore the burst energy distribution of fast radio bursts(FRBs)in the low-twist magnetar model ofWadiasingh & Timokhin(WT19). Motivated by the power-lawfluence distributions of FRB121102, we proposean elementary model for the FRB luminosity function of individual repeaters with an inversion protocol thatdirectly relates the power-law distribution index of magnetar short burstfluences to that for FRBs. The protocolindicates that the FRB energy scales virtually linearly with crust/field dislocation amplitude, if magnetar shortbursts prevail in the magnetoelastic regime. Charge starvation in the magnetosphere during bursts(required inWT19)for individual repeaters implies the predicted burstfluence distribution is narrow,3 decades for yieldingstrains and oscillation frequencies feasible in magnetar crusts. Requiring magnetic confinement and chargestarvation, we obtain a death line for FRBs, which segregates magnetars from the normal pulsar population,suggesting only the former will host recurrent FRBs. We convolve the burst energy distribution for individualmagnetars to define the distribution of luminosities in evolved magnetar populations. The broken power-lawluminosity function’s low-energy character depends on the population model, while the high-energy index tracesthat of individual repeaters. Independent of the evolved population, the broken power-law isotropic-equivalentenergy/luminosity function peaks at∼1037–1040erg with a low-energy cutoff at∼1037erg. Lastly, we considerthe localfluence distribution of FRBs andfind that it can constrain the subset of FRB-producing magnetarprogenitors. Our model suggests that improvements in sensitivity may reveal aflattening of the global FRBfluencedistribution and saturation in FRB rates.

Cosmology↗

Controller design for the improvement of feedback properties: A method for tuning the weight in the evaluation function of the LQG theory

In the controller design of a linear time-invariant system, it is important to improve the feedback properties such as robust stability and sensitivity. In the multi-input multi-output case, these properties can be estimated by using the singular values of return difference matrix. The design method to obtain better singular-value-points is desired. How to tune the weight matrix of performance index and/or covariance matrix of noise in the Linear Quadratic Gaussian (LQC) theory to get a desired singular-value-plot was studied. First, the property of singular-value plots of return difference matrix of a system designed by LQG theory is examined from the viewpoint of tuning weight. Second, a distance between real singular-value-plots and a desired plot is defined, and the weight of performance index is numerically determined by quasi-Newton method so that the distance is minimized.

Saeki, Masami↗

A design study of a photorefractive page composer

A laboratory demonstration and preliminary system analysis of a page composer designed to have the dual advantages of low optical loss and small size, were reported. The current page composer is optically addressed and functions by virtue of optically induced refractive index changes in the active material. Laboratory demonstrations of the device were successfully performed using 10 x 10 bit and 128 x 128 bit data arrays. It was established that the only significant obstacle to the construction of a brass-board model working at megabit data rates is the lack of sensitivity of the photorefractive materials which were considered during the course of this study. Possible materials for future consideration are the photoplastics. While they have more than the required sensitivity, their stability and suitability for double exposure holography was not investigated. If a sufficiently sensitive material is found, then the photorefractive page composer could be built to perform in a highly efficient fashion which would result in a overall reduction of the size of the memory system and an easing of the requirements upon the sensitivity of the holographic recording material.

Source record↗

Use of an Improved Radiation Amplification Factor to Estimate the Effect of Total Ozone Changes on Action Spectrum Weighted Irradiances and an Instrument Response Function

Multiple scattering radiative transfer results are used to calculate action spectrum weighted irradiances and fractional irradiance changes in terms of a power law in ozone OMEGA, U(OMEGA/200)(sup -RAF), where the new radiation amplification factor (RAF) is just a function of solar zenith angle. Including Rayleigh scattering caused small differences in the estimated 30 year changes in action spectrum-weighted irradiances compared to estimates that neglect multiple scattering. The radiative transfer results are applied to several action spectra and to an instrument response function corresponding to the Solar Light 501 meter. The effect of changing ozone on two plant damage action spectra are shown for plants with high sensitivity to UVB (280-315 run) and those with lower sensitivity, showing that the probability for plant damage for the latter has increased since 1979, especially at middle to high latitudes in the Southern Hemisphere. Similarly, there has been an increase in rates of erythemal skin damage and pre-vitamin D3 production corresponding to measured ozone decreases. An example conversion function is derived to obtain erythemal irradiances and the UV index from measurements with the Solar Light 501 instrument response function. An analytic expressions is given to convert changes in erythemal irradiances to changes in CIE vitamin-D action spectrum weighted irradiances.

Herman, Jay R.↗

Normalization of multidirectional red and NIR reflectances with the SAVI

Directional reflectance measurements were made over a semi-desert gramma grassland at various times of the growing season. View angle measurements from +40 to -40 degrees were made at various solar zenith angles and soil moisture conditions. The sensitivity of the Normalized Difference Vegetation Index (NDVI) and the Soil Adjusted Vegetation Index (SAVI) to bidirectional measurements was assessed for purposes of improving remote temporal monitoring of vegetation dynamics. The SAVI view angle response was found to be symmetric about nadir while the NDVI response was strongly anisotropic. This enabled the view angle behavior of the SAVI to be normalized with a cosine function. In contrast to the NDVI, the SAVI was able to minimize soil moisture and shadow influences for all measurement conditions.

Huete, A. R.↗

Dust Optical Properties derived from Sun/Sky Measurements and Satellite Data

We derive the optical properties of dust originating from the Sahara and nearby regions using a combination of ground based and satellite measurements. The AErosol ROBotic NETwork (AERONET) sun/sky radiances from Cap Verde and Sede Boker are used together with Landsat TM data over Senegal and the Atlantic Ocean. The data introduce a cascade of increasing complexity of dust optical properties: The sky aureole radiance is sensitive mainly to the dust size distribution; the TM data over the ocean at 150 deg scattering angle are also sensitive to the spectral refractive index from 470 to 2,210 nm. The TM data over the land measure the balance between the dust scattering and absorption of light reflected by the bright surface, thus very sensitive to dust spectral absorption. Sky radiance at scattering angle of 120 deg, add sensitivity to the dust nonsphericity. Preliminary results, indicative of the ambient dust in the entire atmospheric column, show that dust is less absorbing and with smaller nonspherical properties than anticipated from in situ measurements. Dust is dominated by particles with effective radius of 2 to 2.5 micron, refractive index for wavelengths less then 1 micron of 1.53-0.001i and nonsphericity that increases the phase function at 120 deg above that of spheres by 1.8 and 1.7 at 673 nm down to 1.2 and 1.3 for 1020 nm for Cap Verde and Sede Boker respectively. No significant nonsphericity effect is noticed for scattering angle of 150 deg. This agrees with a mixture of 30% and 45% respectively of Mishchenko et al (JGR, 102, 1997: plate 5 on page 16,841) "polydisperse equiprobable shape mixture of prolate and oblate spheroids with aspect ratios ranging from 1.4 to 2.21, with the rest being spherical particles.

Kaufman, Yoram J.↗

Reliability Sensitivity Analysis and Design Optimization of Composite Structures Based on Response Surface Methodology

This report discusses the development and application of two alternative strategies in the form of global and sequential local response surface (RS) techniques for the solution of reliability-based optimization (RBO) problems. The problem of a thin-walled composite circular cylinder under axial buckling instability is used as a demonstrative example. In this case, the global technique uses a single second-order RS model to estimate the axial buckling load over the entire feasible design space (FDS) whereas the local technique uses multiple first-order RS models with each applied to a small subregion of FDS. Alternative methods for the calculation of unknown coefficients in each RS model are explored prior to the solution of the optimization problem. The example RBO problem is formulated as a function of 23 uncorrelated random variables that include material properties, thickness and orientation angle of each ply, cylinder diameter and length, as well as the applied load. The mean values of the 8 ply thicknesses are treated as independent design variables. While the coefficients of variation of all random variables are held fixed, the standard deviations of ply thicknesses can vary during the optimization process as a result of changes in the design variables. The structural reliability analysis is based on the first-order reliability method with reliability index treated as the design constraint. In addition to the probabilistic sensitivity analysis of reliability index, the results of the RBO problem are presented for different combinations of cylinder length and diameter and laminate ply patterns. The two strategies are found to produce similar results in terms of accuracy with the sequential local RS technique having a considerably better computational efficiency.

Rais-Rohani, Masoud↗

Impact of Assimilating GOES-Derived Land Surface Variables into the PSU/NCAR MM5

Land surface processes are known to have a profound impact on the overlying atmosphere over a wide range of spatial and temporal scales. Many atmospheric numerical models include special parameterizations to improve the specification and partitioning of surface fluxes which are critical to the accurate prediction of warm season boundary layer behavior, organized mesoscale circulations, and convective precipitation. However, the added degrees of freedom resulting from the inclusion of vegetation and soil schemes require the specification of additional surface parameters such as vegetative resistances, green vegetation fraction, leaf area index, soil physical and hydraulic characteristics, and the vertical distribution of soil moisture. As satellite data have become more readily available in recent years, many investigations have attempted to use these new measurements to infer missing components of the surface energy budget. Sensitivity studies have shown land-skin temperature (LST) tendencies during the mid-morning hours are strongly sensitive to the surface moisture availability (a function of soil wetness and vegetation) and less sensitive to other parameters such as surface roughness. Based upon results from these and other studies, developed a simple technique that dynamically assimilates Geostationary Operational Environmental Satellite (GOES) derived land-surface products into the surface energy budget of a mesoscale model. The purpose of this paper is to demonstrate that assimilating the GOES satellite data has the potential to improve the representation of land surface characteristics within the model without prior knowledge of the land surface characteristics. The assimilation technique is presented in Section 2 and the numerical experiments are detailed in Section 3. Preliminary results and conclusions are presented in Sections 4 and 5, respectively.

Lapenta, William M.↗

A2111: A z= 0.23 Butcher-Oemler Cluster with a Non-Isothermal Atmosphere and Normal Metallicity

We report results from an x-ray spectral study of the z=0.23 Abell 2111 galaxy cluster using the Advanced Satellite for Astrophysics and Cosmology and the ROSAT Position Sensitive Proportional Counter. By correcting for the energy-dependent point-spread function of the instruments, we have examined the temperature structure of the cluster. The cluster's core within 3 is found to have a temperature of 5.4 +/- 0.5 keV, significantly higher than 2.8 +/-0.7 keV in the surrounding region of r = 3-6. This radially decreasing temperature structure can be parameterized by a polytropic index of gamma less than 1.4. Furthermore, the intracluster medium appears clumpy on scales less than 1. Early studies have revealed that the x-ray centroid of the cluster shifts with spatial scale and the overall optical and x-ray morphology is strongly elongated. These results together suggest that A2111 in undergoing a merger, which is likely responsible for the high fraction of blue galaxies observed in the cluster. We have further measured the abundance of the medium as 0.25 +/- 0.14 solar. This value is similar to those of nearby clusters which do not show a large blue galaxy function, suggesting that star formation in disk galaxies and subsequent loss to the intracluster medium do not drastically alter the average abundance of a cluster since z=0.23.

Wang, Q. Daniel↗

Rational Design of Nanoplasmonic Array Geometries for Biosensing

Background: Molecular diagnostics provide early and accurate diagnosis, which is essential for the prevention and treatment of infectious as well as chronic diseases. These tests are designed to detect disease-specific bioanalytes such as nucleic acid (DNA or RNA) or protein (antigens, antibodies) biomarkers. In the context of infectious disease diagnosis, nucleic acid-based detection methods are known to provide more specific and sensitive results. Here, the presence of a unique sequence belonging to the pathogenic genomic material is targeted to identify species, organism, genera and/or antimicrobial resistant gene markers. The majority of the common nucleic acid based diagnostic techniques require amplification (polymerase chain reaction, isothermal amplification etc.) of the pathogenic genetic material prior to detection impacting diagnostic speed, complexity, and cost thereby limiting ease of use. Thus, the development of simplified nucleic acid-based diagnostics that can be even used in resource-poor settings may hugely benefit patients across the globe. Nanopath is a molecular diagnostics company utilizing a solid-state nanosensor to enable sequence-specific detection of target nucleic acids without the need of amplification. These nanostructures enable ultra-sensitive biomarker detection using geometric, feature-dependent properties highly dependent on the local dielectric environment, allowing them to be sensitive to low concentration binding events. This paper describes an application of this approach to provide highly relevant clinical information within a single doctor’s office visit. Intro: The Nanopath team is in collaboration with NASA (National Aeronautics and Space Administration) and NIST (National Institute of Standards and Technology) to push the bounds of the fundamental physics associated with their biosensing platform. The ability of metals to support electromagnetic surface waves gives rise to surface plasmons when optically illuminated. This property, and its strong sensitivity to changes in the local refractive index, allows for the use of metal nanoparticles as ultra-sensitive transducers. In prior work by members of this team, ensembles of randomly oriented nanoparticles (i.e., colloidal nanorods dispersed on chip) were employed for sequence-specific nucleic acid sensing (1-3). While these particle sensors have the advantage of rapid fabrication, they suffer from low sensitivity and quality factor due to the random particle dispersity. In contrast, in this study we employ ordered array nanoparticle ensembles which can be used to improve sensor sensitivity and figure-of-merit. Study Methods Overview: In this talk, we detail the results of sensing experiments and computational simulations to outline a rational design of the structure of these plasmonic nanoparticle arrays for biomolecular sensing. Through simulation and experiment, we iteratively tailor nanostructure dimension to provide high quality signal and large resonance shifts upon modeled nucleic acid binding. In particular, full-wave electromagnetic simulations were conducted using Lumerical photonic simulation software in which periodic boundary conditions were applied in the x- and y- dimensions for each of the nanoplasmonic sensor geometries. To simulate the resonance response to changes in the bulk solution in contact with the sensor surface, the refractive index of the surrounding media was changed appropriately. Nucleic acid hybridization events were modeled using either using spherical structures approximating the relevant radius of genomic material as estimated by polymer models, or as conformal layers with the known refractive indices for nucleic acids. On the basis of initial simulations, nanosensors were fabricated using traditional electron-beam lithography protocols at NIST. To evaluate consensus between simulations and experiments, bulk sensing experiments were carried out in which the resonance peaks were obtained by submerging the sensors in refractive index standards. Key nanosensor characteristics including resonance peak locations, resonance peak shifts as a function of refractive index, and figure of merit (FOM) of extinction curves were examined between the experimental and simulation results prior to proceeding with simulations on additional geometries and more complex solution conditions, and further device fabrication. This iterative process is repeated toward a rational design of nanoplasmonic array geometries for biosensing optimizing response for targeted disease detection. In summary, this study puts forth a methodology for rational design and characterization of regularly spaced nanoparticle arrays for optics-based biosensing. The results of this study will allow for more informed design of nanostructure geometries towards sequence-specific nucleic acid detection. These improved designs have the potential to improve clinical sensitivity and limit-of-detection across disease indication.

sensor↗