Engineering PapersSearch

SEARCH · Engineering Papers

Results for “Sensitivity and Specificity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Goal-directed ultrasound in the detection of long-bone fractures

BACKGROUND: New portable ultrasound (US) systems are capable of detecting fractures in the remote setting. However, the accuracy of ultrasound by physicians with minimal ultrasound training is unknown. METHODS: After one hour of standardized training, physicians with minimal US experience clinically evaluated patients presenting with pain and trauma to the upper arm or leg. The investigators then performed a long-bone US evaluation, recording their impression of fracture presence or absence. Results of the examination were compared with routine plain or computer aided radiography (CT). RESULTS: 58 patients were examined. The sensitivity and specificity of US were 92.9% and 83.3%, and of the physical examination were 78.6% and 90.0%, respectively. US provided improved sensitivity with less specificity compared with physical examination in the detection of fractures in long bones. CONCLUSION: Ultrasound scans by minimally trained clinicians may be used to rule out a long-bone fracture in patients with a medium to low probability of fracture.

Validation Studies

Combining Information on Multiple Detection Techniques to Estimate the Effect of Patent Foramen Ovale on Susceptibility to Decompression Illness

The assembly and the maintenance of the International Space Station is expected to require hundreds of extravehicular excursions (EVA's) in the next 10 years. During an EVA, in order to allow movement and bending of limbs, spacesuit pressures are reduced to about 4.3 psi. as compared with about 14.7 psi. for normal atmospheric pressure at sea level. However, the exposure of astronauts to reduced pressures in spacesuits, is conducive to fonnation and growth of gas bubbles within venous blood or tissues, which could cause decompression illness (DCI), a pathology best known to occur among deep-sea divers when they return to the surface. To reduce the risk of DCI, astronauts adjust to the reduced pressure in stages for a prolonged time known as a "pre-breathe" period prior to their extravehicular activity. Despite the use of pre-breathe protocols, an increased risk of DCI can arise for about 25% of humans who have a small hole, known as a patent foramen ovale (PFO), between two chambers of the heart. The atrial septum's fossa oval is, an embryological remnant of a flap between the septae primum and secundum allows fetal right atrial blood to pass into the left atrium, and usually closes after birth (Hagen, et al,. 1984). If fusion does not occur, a valve-like opening, the foramen ovale persists between the two atria. It has been suggested that astronauts with PFO's might be at greater risk of stroke or other serious neurological DCI because bubbles from a venous site may traverse a PFO, travel to the aorta and then enter the cerebral circulatory system causing a stroke (Figure 1). Astronauts are not now screened for PFO's, however consideration is being given to doing so. Here, we study three main methods abbreviated here as "ITE", "TCD" and "TEE", for detecting PFO's in living subjects. All involve the introduction of bubbles into a vein, immediately after which a sensory probe attempts to detect the bubbles in systemic circulation. Presence of the injected bubbles in the systemic circulation is indicative of a PFO. More detailed descriptions are given after the explanation of PFO's under Figure I. Even if a true PFO affects the risk of DCI, there remains a question of how effective screening would be if the detection method has errors of omission and/or commission. Of the three methods studied here, TEE is the "gold standard", matching autopsy results with near-perfect sensitivity and specificity (Schneider, et al. , 1996). However TEE is also the most difficult method to implement, requiring an internal esophagal probe, and is therefore not widely used. Currently, the easiest to use and most common PFO detection method is TTE, which uses an external chest probe. This method has a specificity of near 100%, but suffers from a low sensitivity rate (about 30%). More recently, TCD has been developed, which uses ultrasound probes to detect the presence of bubbles in cerebral arteries. Studies indicate that TCD is quite effective, having a sensitivity of about 91% and a specificity of about 93% (Droste, et al., 1999) when applied correctly, however implementation is difficult and requires considerable training.

Feiveson, Alan H.

Biochemical Detection and Identification False Alarm Rate Dependence on Wavelength Using Laser Induced Fluorescence

Most organic and many inorganic materials absorb strongly in specific wavelength ranges in the deep UV between about 220nm and 300nm. Excitation within these absorption bands results in native fluorescence emission. Each compound or composite material, such as a bacterial spore, has a unique excitation-emission fingerprint that can be used to provide information about the material. The sensitivity and specificity with which these materials can be detected and identified depends on the excitation wavelength and the number and location of observation wavelengths.We will present data on our deep ultraviolet Targeted Ultraviolet Chemical Sensors that demonstrate the sensitivity and specificity of the sensors. In particular, we will demonstrate the ability to quantitatively differentiate a wide range of biochemical agent targets against a wide range of background materials. We will describe the relationship between spectral resolution and specificity in target identification, as well as simple, fast, algorithms to identify materials.Hand-held, battery operated instruments using a deep UV laser and multi-band detection have been developed and deployed on missions to the Antarctic, the Arctic, and the deep ocean with the capability of detecting a single bacterial spore and to differentiate a wide range of organic and biological compounds.

native flourescence

Multi-contrast machine learning improves schistosomiasis diagnostic performance

Schistosomiasis currently affects over 250 million people and remains a public health burden despite ongoing global control efforts. Conventional microscopy is a practical tool for diagnosis and screening ofSchistosoma haematobium, but identification of eggs requires a skilled microscopist. Here we present a machine learning (ML)-based strategy for automated detection ofS. haematobiumthat combines two imaging contrasts, brightfield (BF) and darkfield (DF), to improve diagnostic performance. We collected BF and DF images of urine samples, many of them containingS. haematobiumeggs, during two different field studies in Côte d’Ivoire using a mobile phone-based microscope, the SchistoScope. We then trained separate egg-detection ML models and compared the patient-level performance of BF and DF models alone to combinations of BF and DF models, using annotations from trained microscopists as the gold standard. We found that models trained on DF images, and almost all BF and DF combinations, performed significantly better than models trained on BF images only. When models were trained on images from the first field study (n = 349 patients, 748 images of each contrast), patient-level classification performance on patient images from the second study (n = 375 patients, 752 images of each contrast) met the WHO Diagnostic Target Product Profile (TPP) sensitivity and specificity for the monitoring and evaluation use case (sensitivity for all models and combinations was >75% when evaluated at a confidence score threshold that resulted in specificity >96.5%). When we used images from both field studies for the training set, performance of the models was improved. Overall, this work shows that the use of DF and BF increases the performance of ML models on images from devices with low-cost optics, while retaining the portability, power, and time-to-results of the WHO’s diagnostic TPP. DF requires no additional sample preparation and does not increase the complexity of the imaging system. It thus offers a practical means to improve performance of automated diagnostics forS. haematobiumas well as other microscopy-based diagnostics.

Infectious Diseases

LC/MS Method for the Determination of Stable Isotope Labeled Promethazine in Human Plasma

Promethazine (PMZ) is taken by astronauts orally (PO), intramuscularly (IM) or rectally (PR) for space motion sickness. LC/MS method was developed with off-line solid phase extraction to measure plasma concentrations of PMZ given as stable isotope-labeled (SIL) formulations by the three different routes of administration simultaneously. Samples (0.5ml) were loaded on to Waters Oasis HLB co-polymer cartridges and eluted with 1.0 mL methanol. HPLC separation of the eluted sample was performed using an Agilent Zorbax SB-CN column (50 x 2.1 mm) at a flow rate of 0.2 mL/min for 6 min. Acetonitrile/ ammonium acetate (30 mM) in water (3:2, v/v), pH 5.6 plus or minus 0.1, was used as the mobile phase for separation. Concentrations of PMZ, PMZ-d4 and PMZ-d7 and chlorpromazine (internal standard) were determined using a Micromass ZMD single quadrupole mass spectrometer with Electrospray Ionization (ESI). ESI mass spectra were acquired in positive ion mode with selected ion monitoring of [M+ H]dot plus. The method is rapid, reproducible and the assay specific parameters are listed in a table. A novel, sensitive and specific method for the measurement of PMZ and SIL PMZ in human plasma is reported.

Zuwei, Wang

Manned Lunar Missions: An Exercise in Propulsion Trades and Sensitivities

A recent study performed for the In-Space Propulsion Technology Office at the Marshall Space Flight Center investigated the effects of using different propellant types on the different stages required to perform a manned lunar mission. The original study included investigations into propellant type, propellant storage technology options and sensitivities to specific impulse variations for a lunar orbit rendezvous mission. The initial mission characteristics were based on previous work led by Langley Research Center. Outlined in this paper are the results of that study and the work that followed. A lunar direct return architecture was added to the analysis. Since both architectures required assembly of the various propulsive stages in low Earth orbit and multiple launches to deliver those stages, investigations of launch sequence and scheduling sensitivities were also included. Results show that lunar direct return architectures require more mass to complete missions when compared to lunar orbit rendezvous missions. Within the given architectures, trends in the results tended to be very similar with the architectures indicating very little sensitivity to launch sequence and specific impulse variations and indicating more sensitivity to the propellant choice made for each stage and the time between launches. Even though this study investigates a small subset of the possible lunar architecture trade space, it does begin to outline some of the issues that must be investigated and the characteristics of the mission and the mission elements that are of most importance to a full architecture assessment.

Percy, Thomas K.

Leveraging intermediate resonances to probe CP violation at colliders

We explore the phenomenological impact of interference in tree-level contributions to three-body final states in $2\rightarrow 3$ scattering processes. This work introduces a novel search strategy leveraging asymmetries to enable sensitivity to CP-violating effects in less well-explored regions of phase space. Analytically, we demonstrate the effectiveness of this observable in probing interference between Standard Model charged-current decays and effective left-handed vector interactions, illustrated in a toy model featuring a scalar leptoquark, $S_1 \sim (3, 1, -\,1/3)$. Numerically, we apply this framework to studying the process $pp\rightarrow b \tau \nu $; unlike traditional high-$p_T$ searches or “bump hunts”, this approach utilizes an intermediate energy regime – where new physics is neither light enough to be produced on shell or heavy enough to justify an effective field theory treatment. A proof-of-principle analysis at parton level demonstrates a percent-level asymmetry, with sensitivity also to BSM weak-CP phase. While the specific phase sensitivity is diminished at particle level due to showering and detector effects, a machine learning classifier can recover sensitively to the presence of SM-BSM interference, significantly outperforming standard analysis methods. Notably discrimination between BSM signal and SM background could be achieved at the 2$\sigma $ level for the current LHC dataset and 8$\sigma $ at the High-Luminosity LHC. Moreover, this asymmetry observable as defined can also be more broadly applied to other searches for CP-violation in $2\rightarrow 3$ processes in present and future collider environments.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS

Micromotional studies of utricular and canal afferents

The long-range goal of this research was to refine our understanding of the sensitivity of the vestibular components of the ear to very-low-amplitude motion, especially, the role of gravity in this sensitivity. We focused on the American bullfrog--a common animal subject for vestibular sensory research. Our principal experimental method was to apply precise, sinusoidal microrotational stimuli to an anesthetized animal subject, to record the resulting responses in an individual vestibular nerve fiber from the intact ear, and to use intracellular dye to trace the fiber and thus identify the vestibular sensor that gave rise to it. In this way, we were able to identify specific micromotional sensitivities and to associate those sensitivities definitely with specific sensors. Furthermore, by recording from nerve fibers after they leave the intact inner-ear cavity, we were able to achieve these identifications without interrupting the delicate micromechanics of the inner ear. We were especially concerned with the relative roles of the utricle and the anterior semicircular canal in the sensing of microrotational motion of the head about horizontal axes, and with the role of gravity in mediating that sensing process in the utricle. The functional characterization of individual nerve fibers was accomplished with a conventional analytical tool, the cycle histogram, in which the nerve impulse rate was plotted against the phase of the sinusoidal stimulus.

Lewis, Edwin R.

Degree Of Diminution In Vagal-Cardiac Activity Predicts Sudden Death In Familial Dysautonomia When Resting Tachycardia Is Absent

Patients with familial dysautonomia (FD) have an increased risk of sudden death, but sensitive and specific predictors of sudden death in FD are lacking. Methods. We recorded 10-min resting high-fidelity 12-lead ECGs in 14 FD patients and in 14 age/gender-matched healthy subjects and studied 25+ different heart rate variability (HRV) indices for their ability to predict sudden death in the FD patients. Indices studied included those from 4 "nonlinear" HRV techniques (detrended fluctuation analysis, approximate entropy, correlation dimension, and PoincarC analyses). The predictive value of PR, QRS, QTc and JTc intervals, QT dispersion (QTd), beat-to-beat QT and PR interval variability indices (QTVI and PRVI) and 12- lead high frequency QRS ECG (150-250 Hz) were also studied. FD patients and controls (C) differed (Pless than 0.0l) with respect to 20+ of the HRV indices (FD less than C) and with respect to QTVI and PRVI (FDBC) and HF QRS- related root mean squared voltages (FDBC) and reduced amplitude zone counts (FD less than C). They differed less with respect to PR intervals (FD less than C) and JTc intervals (FD greater than C) (P less than 0.05 for both) and did not differ at all with respect to QRS and QTc intervals and to QTd. Within 12 months after study, 2 of the 14 patients succumbed to sudden cardiac arrest. The best predictor of sudden death was the degree of diminution in HRV vagal-cardiac (parasympathetic) parameters such as RMSSD, the SDl of Poincare plots, and HF spectral power. Excluding the two FD patients who had resting tachycardia (HR greater than 100, which confounds traditional HRV analyses), the following criteria were independently 100% sensitive and 100% specific for predicting sudden death in the remaining 12 FD patients during spontaneous breathing: RMSSD less than 13 ms and/or PoincarC SD1 less than 9 ms. In FD patients without supine tachycardia, the degree of diminution in parasympathetic HRV parameters (by high-fidelity ECG) predicts incipient death.

Schlegel, T. T.

Sampling of Trace Atmospheric Constituents Above the Surface of Mars from a Montgolfiere Balloon

We suggest that use of an aerially deployed, solar-heated balloon, or Montgolfiere, during a Martian polar summer could provide an optimal platform for atmospheric measurements near the surface. Solar Montgolfieres are empty balloons with a hole in the bottom that fill with ambient atmosphere while failing and are rapidly heated in by the sun, thus providing buoyancy. Such a balloon would be driven by the Martian winds in the constant sunlight of a high latitude entry and could provide a traverse of thousands of kilometers. It would encircle the Martian north polar region over a period,likely lasting over one earth month, and its altitude could be controlled as low as 100 meters to as high as 4000 meters above the surface. The significant payload of tens of kilograms allowed by this technology could readily accommodate the mass of instrumentation and the power source needed for a sensitive search for disequilibrium species that might provide the atmospheric signature of localized subsurface biological or geological activity. A mass spectrometer used in combination with gas enrichment techniques can provide sensitivities to sub parts per billion for several species of interest. Additional highly specific and sensitive detectors can search for other species or measurements of their mixing ratio variation along the path of the balloon. It would be useful to combine these atmospheric measurements with electromagnetic sounding to search for variations in subsurface conductivity that might indicate the presence of subsurface water. After a month of operation, the balloon could also soft land the DBMS to provide additional data on soil samples from a 1-2 meter subsurface drill. In order to float a 30-kg payload at altitudes between 100 m and 4000 m above the Martian north polar surface, an aluminized polyethylene Montgolfiere would be approximately 29 meters in diameter and have a mass of 27 kg. Altitude variations could be accomplished by means of an upper vent to release hot gas, as has been tested at JPL, or be means of a simple, internal winch mechanism to decrease the volume of the balloon. JPL has successfully deployed three polyethylene Montgolfieres at 4-6 mbar pressure in the Earth's stratosphere and will be deploying a 20-m diameter polyethylene Montgolfiere later in 2001.

Jones, Jack A.

Pulmonary venous flow determinants of left atrial pressure under different loading conditions in a chronic animal model with mitral regurgitation

BACKGROUND: The aim of our study was to quantitatively compare the changes and correlations between pulmonary venous flow variables and mean left atrial pressure (mLAP) under different loading conditions in animals with chronic mitral regurgitation (MR) and without MR. METHODS: A total of 85 hemodynamic conditions were studied in 22 sheep, 12 without MR as control (NO-MR group) and 10 with MR (MR group). We obtained pulmonary venous flow systolic velocity (Sv) and diastolic velocity (Dv), Sv and Dv time integrals, their ratios (Sv/Dv and Sv/Dv time integral), mLAP, left ventricular end-diastolic pressure, and MR stroke volume. We also measured left atrial a, x, v, and y pressures and calculated the difference between v and y pressures. RESULTS: Average MR stroke volume was 10.6 +/- 4.3 mL/beat. There were good correlations between Sv (r = -0.64 and r = -0.59, P <.01), Sv/Dv (r = -0.62 and r = -0.74, P <.01), and mLAP in the MR and NO-MR groups, respectively. Correlations were also observed between Dv time integral (r = 0.61 and r = 0.57, P <.01) and left ventricular end-diastolic pressure in the MR and NO-MR groups. In velocity variables, Sv (r = -0.79, P <.001) was the best predictor of mLAP in both groups. The sensitivity and specificity of Sv = 0 in predicting mLAP 15 mm Hg or greater were 86% and 85%, respectively. CONCLUSION: Pulmonary venous flow variables correlated well with mLAP under altered loading conditions in the MR and NO-MR groups. They may be applied clinically as substitutes for invasively acquired indexes of mLAP to assess left atrial and left ventricular functional status.

Pulmonary Veins/physiopathology

High Frequency QRS ECG Accurately Detects Cardiomyopathy

High frequency (HF, 150-250 Hz) analysis over the entire QRS interval of the ECG is more sensitive than conventional ECG for detecting myocardial ischemia. However, the accuracy of HF QRS ECG for detecting cardiomyopathy is unknown. We obtained simultaneous resting conventional and HF QRS 12-lead ECGs in 66 patients with cardiomyopathy (EF = 23.2 plus or minus 6.l%, mean plus or minus SD) and in 66 age- and gender-matched healthy controls using PC-based ECG software recently developed at NASA. The single most accurate ECG parameter for detecting cardiomyopathy was an HF QRS morphological score that takes into consideration the total number and severity of reduced amplitude zones (RAZs) present plus the clustering of RAZs together in contiguous leads. This RAZ score had an area under the receiver operator curve (ROC) of 0.91, and was 88% sensitive, 82% specific and 85% accurate for identifying cardiomyopathy at optimum score cut-off of 140 points. Although conventional ECG parameters such as the QRS and QTc intervals were also significantly longer in patients than controls (P less than 0.001, BBBs excluded), these conventional parameters were less accurate (area under the ROC = 0.77 and 0.77, respectively) than HF QRS morphological parameters for identifying underlying cardiomyopathy. The total amplitude of the HF QRS complexes, as measured by summed root mean square voltages (RMSVs), also differed between patients and controls (33.8 plus or minus 11.5 vs. 41.5 plus or minus 13.6 mV, respectively, P less than 0.003), but this parameter was even less accurate in distinguishing the two groups (area under ROC = 0.67) than the HF QRS morphologic and conventional ECG parameters. Diagnostic accuracy was optimal (86%) when the RAZ score from the HF QRS ECG and the QTc interval from the conventional ECG were used simultaneously with cut-offs of greater than or equal to 40 points and greater than or equal to 445 ms, respectively. In conclusion 12-lead HF QRS ECG employing RAZ scoring is a simple, accurate and inexpensive screening technique for cardiomyopathy. Although HF QRS ECG is highly sensitive for cardiomyopathy, its specificity may be compromised in patients with cardiac pathologies other than cardiomyopathy, such as uncomplicated coronary artery disease or multiple coronary disease risk factors. Further studies are required to determine whether HF QRS might be useful for monitoring cardiomyopathy severity or the efficacy of therapy in a longitudinal fashion.

Schlegel, Todd T.

Ensembles of radial basis function networks for spectroscopic detection of cervical precancer

The mortality related to cervical cancer can be substantially reduced through early detection and treatment. However, current detection techniques, such as Pap smear and colposcopy, fail to achieve a concurrently high sensitivity and specificity. In vivo fluorescence spectroscopy is a technique which quickly, noninvasively and quantitatively probes the biochemical and morphological changes that occur in precancerous tissue. A multivariate statistical algorithm was used to extract clinically useful information from tissue spectra acquired from 361 cervical sites from 95 patients at 337-, 380-, and 460-nm excitation wavelengths. The multivariate statistical analysis was also employed to reduce the number of fluorescence excitation-emission wavelength pairs required to discriminate healthy tissue samples from precancerous tissue samples. The use of connectionist methods such as multilayered perceptrons, radial basis function (RBF) networks, and ensembles of such networks was investigated. RBF ensemble algorithms based on fluorescence spectra potentially provide automated and near real-time implementation of precancer detection in the hands of nonexperts. The results are more reliable, direct, and accurate than those achieved by either human experts or multivariate statistical algorithms.

Cervix Neoplasms/pathology

Accuracy for detection of simulated lesions: comparison of fluid-attenuated inversion-recovery, proton density--weighted, and T2-weighted synthetic brain MR imaging

OBJECTIVE: The objective of our study was to determine the effects of MR sequence (fluid-attenuated inversion-recovery [FLAIR], proton density--weighted, and T2-weighted) and of lesion location on sensitivity and specificity of lesion detection. MATERIALS AND METHODS: We generated FLAIR, proton density-weighted, and T2-weighted brain images with 3-mm lesions using published parameters for acute multiple sclerosis plaques. Each image contained from zero to five lesions that were distributed among cortical-subcortical, periventricular, and deep white matter regions; on either side; and anterior or posterior in position. We presented images of 540 lesions, distributed among 2592 image regions, to six neuroradiologists. We constructed a contingency table for image regions with lesions and another for image regions without lesions (normal). Each table included the following: the reviewer's number (1--6); the MR sequence; the side, position, and region of the lesion; and the reviewer's response (lesion present or absent [normal]). We performed chi-square and log-linear analyses. RESULTS: The FLAIR sequence yielded the highest true-positive rates (p < 0.001) and the highest true-negative rates (p < 0.001). Regions also differed in reviewers' true-positive rates (p < 0.001) and true-negative rates (p = 0.002). The true-positive rate model generated by log-linear analysis contained an additional sequence-location interaction. The true-negative rate model generated by log-linear analysis confirmed these associations, but no higher order interactions were added. CONCLUSION: We developed software with which we can generate brain images of a wide range of pulse sequences and that allows us to specify the location, size, shape, and intrinsic characteristics of simulated lesions. We found that the use of FLAIR sequences increases detection accuracy for cortical-subcortical and periventricular lesions over that associated with proton density- and T2-weighted sequences.

NASA Discipline Neuroscience

Polarization sensitivity analysis of an earth remote sensing instrument - The MODIS-N phase B study

Polarization analysis software that employs Jones matrix formalism to calculate the polarization sensitivity of an instrument design was developed at Hughes Danbury Optical Systems. The code is capable of analyzing the full ray bundle at its angles of incidence for each optical surface. Input is based on the system ray trace and the thin film coating design at each surface. The MODIS-N (Moderate Resolution Imaging Spectrometer) system is used to demonstrate that it is possible to meet stringent requirements on polarization insensitivity associated with planned remote sensing instruments. Analysis indicates that a polarization sensitivity less than or equal to 2 percent was achieved in all desired spectral bands at all pointing angles, per specification. Polarization sensitivities were as high as 10 percent in similar remote sensing instruments.

Waluschka, E.

Comparisons of Bispectral and Polarimetric Retrievals of Marine Boundary Layer Cloud Microphysics: Case Studies Using a LES-Satellite Retrieval Simulator

Many passive remote-sensing techniques have been developed to retrieve cloud microphysical properties from satellite-based sensors, with the most common approaches being the bispectral and polarimetric techniques. These two vastly different retrieval techniques have been implemented for a variety of polar-orbiting and geostationary satellite platforms, providing global climatological data sets. Prior instrument comparison studies have shown that there are systematic differences between the droplet size retrieval products (effective radius) of bispectral (e.g., MODIS, Moderate Resolution Imaging Spectroradiometer) and polarimetric (e.g., POLDER, Polarization and Directionality of Earth's Reflectances) instruments. However, intercomparisons of airborne bispectral and polarimetric instruments have yielded results that do not appear to be systematically biased relative to one another. Diagnosing this discrepancy is complicated, because it is often difficult for instrument intercomparison studies to isolate differences between retrieval technique sensitivities and specific instrumental differences such as calibration and atmospheric correction. In addition to these technical differences the polarimetric retrieval is also sensitive to the dispersion of the droplet size distribution (effective variance), which could influence the interpretation of the droplet size retrieval. To avoid these instrument-dependent complications, this study makes use of a cloud remote-sensing retrieval simulator. Created by coupling a large-eddy simulation (LES) cloud model with a 1-D radiative transfer model, the simulator serves as a test bed for understanding differences between bispectral and polarimetric retrievals. With the help of this simulator we can not only compare the two techniques to one another (retrieval intercomparison) but also validate retrievals directly against the LES cloud properties. Using the satellite retrieval simulator, we are able to verify that at high spatial resolution (50 m) the bispectral and polarimetric retrievals are highly correlated with one another within expected observational uncertainties. The relatively small systematic biases at high spatial resolution can be attributed to different sensitivity limitations of the two retrievals. In contrast, a systematic difference between the two retrievals emerges at coarser resolution. This bias largely stems from differences related to sensitivity of the two retrievals to unresolved inhomogeneities in effective variance and optical thickness. The influence of coarse angular resolution is found to increase uncertainty in the polarimetric retrieval but generally maintains a constant mean value.

Miller, Daniel J.

Comparisons of Bispectral and Polarimetric Retrievals of Marine Boundary Layer Cloud Microphysics: Case Studies Using a LES- Satellite Retrieval Simulator

Many passive remote-sensing techniques have been developed to retrieve cloud microphysical properties from satellite-based sensors, with the most common approaches being the bispectral and polarimetric techniques. These two vastly different retrieval techniques have been implemented for a variety of polar-orbiting and geostationary satellite platforms, providing global climatological data sets. Prior instrument comparison studies have shown that there are systematic differences between the droplet size retrieval products (effective radius) of bispectral (e.g., MODIS, Moderate Resolution Imaging Spectroradiometer) and polarimetric (e.g., POLDER, Polarization and Directionality of Earth's Reflectances) instruments. However, intercomparisons of airborne bispectral and polarimetric instruments have yielded results that do not appear to be systematically biased relative to one another. Diagnosing this discrepancy is complicated, because it is often difficult for instrument intercomparison studies to isolate differences between retrieval technique sensitivities and specific instrumental differences such as calibration and atmospheric correction. In addition to these technical differences the polarimetric retrieval is also sensitive to the dispersion of the droplet size distribution (effective variance), which could influence the interpretation of the droplet size retrieval. To avoid these instrument-dependent complications, this study makes use of a cloud remote-sensing retrieval simulator. Created by coupling a large-eddy simulation (LES) cloud model with a 1-D radiative transfer model, the simulator serves as a test bed for understanding differences between bispectral and polarimetric retrievals. With the help of this simulator we can not only compare the two techniques to one another (retrieval intercomparison) but also validate retrievals directly against the LES cloud properties. Using the satellite retrieval simulator, we are able to verify that at high spatial resolution (50m) the bispectral and polarimetric retrievals are highly correlated with one another within expected observational uncertainties. The relatively small systematic biases at high spatial resolution can be attributed to different sensitivity limitations of the two retrievals. In contrast, a systematic difference between the two retrievals emerges at coarser resolution. This bias largely stems from differences related to sensitivity of the two retrievals to unresolved inhomogeneities in effective variance and optical thickness. The influence of coarse angular resolution is found to increase uncertainty in the polarimetric retrieval but generally maintains a constant mean value.

Miller, Daniel J.

The case for aerodynamic sensitivity analysis

No specific solutions are offered, nor verified by applications, for its subject problem which is sensitivity analysis in Computational Fluid Dynamics (CFD). Instead, a plea is made to the CFD community for extending their present capability to include sensitivity analysis. The plea is made from the viewpoint of an aeronautical engineer, not an expert in CFD methods, who needs the sensitivity information when working at the junction of aerodynamics, structures, active controls, and other disciplines whose inputs need to be integrated in aircraft design.

Sobieszczanski-Sobieski, Jaroslaw