Optical Relays for Imaging Scintillators

Cygnus is a dual beam high-energy radiographic x-ray source. Ten years ago, three large zoom lenses were assembled to collect images from 200 mm x 200 mm square scintillators. The zoom capability allows zooming down to a 60 mm x 60 mm picture from the scintillator. Current radiographic imaging needs now require larger 270 mm x 270 mm square scintillators and the capability to use both 92 mm x 92 mm and 62 mm x 62 mm CCD cameras, and a new lens design to meet these needs. This zoom lens incorporates 11 elements and is designed to be telecentric. It images a scintillator emitting light peaking at 435 nm, so special glass types are required for the lens elements. Much larger elliptical pellicles are needed to deflect the scintillator light out of the x-ray path into the lens. The optical axis of the imaging system must be colinear with the x-ray axis. Two scintillators are positioned in each of two Cygnus x-ray axes, for a total of four scintillators and four lens systems. An optional configuration will be shown, enabling two lens systems imaging opposite sides of a single scintillator, for a total of four lenses and two scintillators. Although this configuration has advantages, it suffers from crosstalk. Care must be taken to analyze the anti-reflection coatings applied to all the elements in the imaging chain, including the CCD array and

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Advances in High Resolution Ultrafast Scintillators for Fast timing Applications

Scintillation detectors exhibiting high spatial resolution and fast timing capabilities are of vital importance for synchrotron sources. These detectors may be exposed to a variety of X-ray energies (up to 140 keV) and used in high frame rate applications. Here, we describe the advances in the development of thin-film LuI3:Ce scintillators for higher energy X-ray imaging, with fast timing and high spatial resolution. When grown in a single crystalline form, these scintillators are bright, producing 115 000 photons/MeV. However, to achieve high spatial resolution, these scintillators are grown in thin-film form with a microcolumnar structure, controllable to column diameters of <1-30 mu m. Thus, a much thicker scintillator layer (10 mu m-3 mm or higher) may be grown, providing superior X-ray absorption while achieving high resolutions of 50 mu m or better, at the cost of reduced light yield. To study the timing characteristics of the scintillator, time-resolved X-ray excited optical luminescence (TR-XEOL) was performed on two different sets of three samples of LuI3 at the 1-BM beamline of the Advanced Photon Source at Argonne National Laboratory. Besides, we report timing measurements obtained using a photomultiplier tube (PMT) and oscilloscope at Radiation Monitoring Devices (RMD) Inc. Using the TR-XEOL, we determined the decay constants of LuI3 as a function of Ce doping, recording a fast decay component as low as 3.6 ns (39%), one of the fastest values recorded in inorganic scintillators. This fast decay opens up numerous novel applications, where ultrahigh frame rates are important using synchrotron X-rays. This article will discuss fabrication, characterization, and potential applications for this novel scintillator.

fast timing↗

Melt Blending: A Tool to Simplify Plastic Scintillator Synthesis

Plastic scintillators are widely used as radiation detection media in homeland security and nuclear physics applications. Their attributes include low cost, scalability to large detector volumes, and additive compounding to enable additional material and detection features, such as pulse shape discrimination (PSD), gamma-ray spectroscopy, aging resistance, and coincidence timing. However, traditional chemically cured plastic scintillators (CCS) require long reaction times, and hazardous wet chemical procedures performed by specially trained personnel, and can leave residual monomer, resulting in deleterious optical and material properties. Here, we synthesize melt blended scintillators (MBSs) in 2.5 days using easily accessible solid-state compounding of commercially-available poly(styrene) with 30–60 wt% fluorene-based compound “P2” to create monolithic detectors with < 100 ppm residual monomer, in several form factors. Further, the best scintillation performance was recorded for 60 wt% P2 in Styron 665, including gamma-ray light yield 139% of EJ- 200 commercial scintillator and PSD figure of merit (FOM) value of 2.65 at 478 keVee, approaching P2 organic glass scintillator (OGS). The capability of MBS to generate fog-resistant scintillators and poly(methyl methacrylate) (PMMA)-based scintillators for use in challenging environments is also demonstrated.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Measuring Thickness-Dependent Relative Light Yield and Detection Efficiency of Scintillator Screens

Digital camera-based neutron imaging systems consisting of a neutron scintillator screen optically coupled to a digital camera are the most common digital neutron imaging system used in the neutron imaging community and are available at any state-of-the-art imaging facility world-wide. Neutron scintillator screens are the integral component of these imaging system that directly interacts with the neutron beam and dictates the neutron capture efficiency and image quality limitations of the imaging system. This work describes a novel approach for testing neutron scintillators that provides a simple and efficient way to measure relative light yield and detection efficiency over a range of scintillator thicknesses using a single scintillator screen and only a few radiographs. Additionally, two methods for correlating the screen thickness to the measured data were implemented and compared. An example 6LiF:ZnS scintillator screen with nominal thicknesses ranging from 0–300 μm was used to demonstrate this approach. The multi-thickness screen and image and data processing methods are not exclusive to neutron scintillator screens but could be applied to X-ray imaging as well. This approach has the potential to benefit the entire radiographic imaging community by offering an efficient path forward for manufacturers to develop higher-performance scintillators and for imaging facilities and service providers to determine the optimal screen parameters for their particular beam and imaging system.

42 ENGINEERING↗

Characterization of a boron-loaded deuterated liquid scintillator for fast and thermal neutron detection

The preparation and characterization of novel boron-loaded deuterated liquid scintillators (BLDLS) are presented for the first time to investigate the performance of a detector sensitive to both fast and thermal neutrons intended for future neutron spectroscopy measurements. Three deuterated toluene-based scintillation cocktails were produced, one without boron, one loaded with ortho-carborane (natural boron isotopic abundance), and one with 96 wt% 10B enriched ortho-carborane. General optical and material properties were analyzed to include the composition, density, index of refraction, photoluminescence emission spectra, and absorbance spectra in addition to the relative light yield, resolution, relative efficiency, and pulse-shape-discrimination performance for all three scintillators and a hydrogen-based EJ-309 scintillator to evaluate the effects of boron loading in comparison with a common commercially-available scintillator and feasibility for future neutron spectroscopy measurements. Finally, the detection of shielded neutron sources was explored to capitalize on the 10B thermal neutron capture reaction. The results showed loading the scintillators with boron deteriorated the PSD performance slightly compared to the unloaded deuterated scintillator and resulted in a relative light yield loss of 26% and 41% for the 10B enriched and natural boron BLDLS, respectively. Lastly, the BLDLS have a higher relative detection efficiency than the unloaded deuterated scintillator for shielded neutron sources, based on total count rate, a desirable characteristic for missions related to finding and characterizing illicitly-trafficked special nuclear material.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Pulse-shape discrimination in water-based scintillators

This work describes a class of liquid scintillators that contain mostly water (>50 wt% of the entire composition) and can discriminate between interactions induced by neutrons and gamma rays. Here, by balancing the interface interactions between the components of the formulation, these scintillators form emulsions that can be thermodynamically stable. This approach, which considers a quantity known as the hydrophilic–lipophilic difference, requires consideration of the salinity and temperature as well as characterization of the surfactants and oil phase. Emulsions comprised of water and various oils were characterized first. Then, the effect of scintillating dyes in the oil phase was considered, followed by the construction of partial phase diagrams of the emulsions. For transparent oil-in-water emulsions with a single phase, the scintillation light yield and metrics related to pulse-shape discrimination were measured. The best performing scintillators contained 33 wt% of a scintillating oil phase and exhibited a light yield that was as high as 18% of the light yield of a commercially available liquid scintillator that does not contain water (EJ-309). These water-based liquid scintillators exhibited a figure of merit of neutron/gamma ray discrimination as high as 1.79 at about 1500 keV ee .

36 MATERIALS SCIENCE↗

Picosecond measurements of plastic scintillator pulse shapes from gamma-ray interactions

An understanding of the pulse shape of organic scintillators can provide insight into scintillation mechanisms and inform the selection of the optimal detector material for a given application. Although the timing properties of organic scintillators have been extensively studied, significant discrepancies persist in reported rise and decay times. New plastic scintillating media have also been developed in recent years for which no literature data exist. The goal of this work is to provide high-precision measurements of the pulse shape of a suite of fast plastic organic scintillators from Eljen Technology—EJ-200, EJ-204, EJ-208, EJ-230, EJ-232, and EJ-232Q (with 0.5% benzophenone)—under excitation from $γ$-ray sources. The contributors to the system temporal resolution were quantified, and the dominant source of uncertainty was identified as the determination of the start time of a scintillation event. A pulse shape model was applied to the reconstructed temporal distributions, and rise and decay times were extracted and compared with manufacturer specifications. This work outlines a measurement approach to obtain the pulse shape of organic scintillators in response to $γ$-rays with temporal resolution on the order of tens of picoseconds, yielding data required for modeling plastic scintillator based detection systems for a range of applications.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Simultaneous measurement of organic scintillator response to carbon and proton recoils

Organic scintillators are widely used for neutron detection in both basic nuclear physics and applications. While the proton light yield of organic scintillators has been extensively studied, measurements of the light yield from neutron interactions with carbon nuclei are scarce. Demonstrate a new approach for the simultaneous measurement of the proton and carbon light yield of organic scintillators. Provide new carbon light yield data for the EJ-309 liquid and EJ-204 plastic organic scintillators. A 33-MeV 2 H + beam from the 88-Inch Cyclotron at Lawrence Berkeley National Laboratory was impinged upon a 3-mm-thick Be target to produce a high-flux, broad-spectrum neutron beam. The double time-of-flight technique was extended to simultaneously measure the proton and carbon light yields of the organic scintillators, wherein the light output associated with the recoil particle was determined using np and nC elastic scattering kinematics. The proton and carbon light yield relations of the EJ-309 liquid and EJ-204 plastic organic scintillators were measured over a recoil energy range of approximately 0.3 to 1 MeV and 2 to 5 MeV, respectively, for EJ-309, and 0.2 to 0.5 MeV and 1 to 4 MeV, respectively, for EJ-204. Furthermore, these data provide new insight into the ionization quenching effect in organic scintillators and key input for simulation of the response of organic scintillators for both basic science and a broad range of applications.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Metal Halide Scintillators with Fast and Self‐Absorption‐Free Defect‐Bound Excitonic Radioluminescence for Dynamic X‐Ray Imaging

Abstract Scintillators for radiation detection are of great significance in medical imaging, security, and nondestructive inspection. The current challenge for scintillators is to simultaneously achieve high scintillation light yield, fast radioluminescence, simple film fabrication, large X‐ray attenuation efficiency as well as stable and nontoxic compositions; no previous scintillators fulfill all the above requirements. Here, metal halide Rb 2 AgBr 3 , possessing defect‐bound excitonic radioluminescence, is shown as efficient and fast scintillators. This nontoxic and stable scintillator emits from excitons bound to neutral bromine vacancies, enjoying an efficient and spin‐allowed fast emission with minimized self‐absorption. Rb 2 AgBr 3 thus has a high light yield (25 600 photons MeV −1 ), fast scintillation decay time (5.31 ns), and a record value of light yield versus decay time (4821 photons MeV −1 ns −1 ). The close‐space sublimation method is developed for fast and scalable fabrication of oriented Rb 2 AgBr 3 films. The scintillator film is further integrated with commercial flat‐panel imagers, and the spatial resolution reaches 10.2 line pairs per millimeter at the modulation transfer function of 0.2, doubling the resolution of conventional CsI:Tl flat‐panel detectors. The dynamic X‐ray imaging and its use to real‐time monitoring of bone movement without ghosting effect is also demonstrated.

Zhang, Muyi↗

Scintillation event imaging with a single photon avalanche diode camera

Position and time measurements of scintillation events encode information about the radiation source. Single photon avalanche diode (SPAD) arrays offer multiple-megapixel spatial resolution and tens of picoseconds temporal resolution for detecting single photons. Current lensless designs for measuring scintillation events use sensors that are lower in spatial resolution. Camera-based designs use sensors that are lower in temporal resolution or readout rate and cannot image individual interactions. Here we propose to image scintillation events in a thick, monolithic scintillator using a high-resolution SPAD camera. We demonstrate that a commercial SPAD camera is able to gather sufficient signal to image individual scintillation events and observe 3D shifts in their spatial distribution. Simulations show that a SPAD camera can localize individual scintillation events in 3D. We report direct imaging of gamma-ray interactions in a scintillator with a SPAD camera. The proposed design may allow to measure complex signatures of individual particles interacting in the scintillator.

47 OTHER INSTRUMENTATION↗

Scintillation and cherenkov photon counting detectors with analog silicon photomultipliers for TOF-PET

Objective. Standard signal processing approaches for scintillation detectors in positron emission tomography (PET) derive accurate estimates for 511 keV photon time of interaction and energy imparted to the detection media from aggregate characteristics of electronic pulse shapes. The ultimate realization of a scintillation detector for PET is one that provides a unique timestamp and position for each detected scintillation photon. Detectors with these capabilities enable advanced concepts for three-dimensional (3D) position and time of interaction estimation with methods that exploit the spatiotemporal arrival time kinetics of individual scintillation photons. Approach. In this work, we show that taking into consideration the temporal photon emission density of a scintillator, the channel density of an analog silicon photomultiplier (SiPM) array, and employing fast electronic readout with digital signal processing, a detector that counts and timestamps scintillation photons can be realized. To demonstrate this approach, a prototype detector was constructed, comprising multichannel electronic readout for a bismuth germanate (BGO) scintillator coupled to an SiPM array. Main Results. In proof-of-concept measurements with this detector, we were able to count and provide unique timestamps for 66% of all optical photons, where the remaining 34% (two-or-more-photon pulses) are also independently counted, but each photon bunch shares a common timestamp. We show this detector concept can implement 3D positioning of 511 keV photon interactions and thereby enable corrections for time of interaction estimators. The detector achieved 17.6% energy resolution at 511 keV and 237 ± 10 ps full-width-at-half-maximum coincidence time resolution (CTR) (fast spectral component) versus a reference detector. We outline the methodology, readout, and approach for achieving this detector capability in first-ever, proof-of-concept measurements for scintillation photon counting detector with analog silicon photomultipliers. Significance. The presented detector concept is a promising design for large area, high sensitivity TOF-PET detector modules that can implement advanced event positioning and time of interaction estimators, which could push state-of-the-art performance.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Status of Scintillator Development at Fermilab

Fermilab has had a 20+ year history in producing scintillator and is now one of the largest producers of organic scintillator in the world. Its scintillator has been used in a wide variety of applications including archeology, volcanology, mining exploration, agriculture, national security, as well as more traditional applications in HEP and Astro-particle physics. We will survey these applications. We have a scintillator extrusion facility and recently we have added injection molding capacity. We will discuss ongoing and near-term future projects for these facilities. We discuss ongoing R&D to improve light yield and timing performance of the extruded scintillator and hence reduce cost. We will discuss methods to improve light yield of injection-molded scintillator by refinements in the scintillator chemistry and process. Finally, we will present longer-term future plans for making new scintillating materials tailored for specific applications.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Gallium oxide (Ga 2 O 3 ) energy dependent scintillation response to fast neutrons and flash gamma-rays

Gallium oxide is a newly emerged ultrawide bandgap (4.9 eV) semiconductor that is suitable as a combined electronics and radiation detection platform. We have experimentally demonstrated fast neutron and gamma-ray scintillation from Czochralski-grown β-Ga 2 O 3 in a recent series (October 2023) of experiments at the unmoderated pulsed neutron spallation source located at the Los Alamos Neutron Science Center. Using the neutron time-of-flight (TOF) technique and a fast-gated intensified CCD camera, we observed energy-dependent neutron scintillation for neutron energies ranging from 1 to 400 MeV, including the 14.1 MeV neutron energy relevant to D–T fusion. Neutron flux is quantified and calibrated by cascading the scintillator after the fission chamber, enabling a detailed analysis of temporal and energy-dependent characteristics of the scintillation events. Further, a pronounced scintillation signal from the spallation gamma flash with a temporal full width of half maximum of ~4 ns is indicative of the material’s rapid response. Neutron energy dependent scintillation is observed using the TOF method at a 22.6-m distance from the neutron source. These results highlight the possibility of developing a Ga 2 O 3 based fusion neutron diagnostic platform integrated with both scintillation and electronics functions on the integrated chip scale.

47 OTHER INSTRUMENTATION↗

On optical properties and scintillation performance of emerging Ga 2 O 3 : Crystal growth, emission mechanisms and doping strategies

As an emerging ultra-wide bandgap compound semiconductor, Ga 2 O 3 has attracted rapidly growing interest due to its unique physical properties for harsh condition applications. Compared to Ga 2 O 3 ’s electrical-characteristic based uses, such as power electronics, photodetectors and solar cells, a much less explored area for Ga 2 O 3 is its promising optical properties and its related scintillation capabilities. Undoped Ga 2 O 3 is a strong scintillator with excellent scintillation characteristics such as fast decay constants and encouraging light yield which is comparable to that of the classic Bi 4 Ge 3 O 12 (BGO) scintillator. The scintillation capability of Ga 2 O 3 can be precisely tuned via a series of approaches including systematic crystal growth control, post-growth annealing, targeted doping, and optimization of operation temperature. Here we summarize exciting progress of Ga 2 O 3 scintillators which have been pursued over the past few years. Our efforts cover a series of growth techniques of Ga 2 O 3 materials as well as discussion of emission mechanisms. Here we dedicate a targeted portion toward the doping strategies to improve the performance of Ga 2 O 3 . A detailed analysis is provided to compare the impact of different dopants. Through these efforts, we hope to provide useful perspectives to help accelerate the development of high performance Ga 2 O 3 scintillators.

36 MATERIALS SCIENCE↗

Scintillator light yield measurements with waveform digitizers

The proton light yield of organic scintillators has been measured extensively in recent years using fast waveform digitizers and large discrepancies exist in the values reported by different authors. In this letter, we address principles of digital signal processing that must be considered when conducting scintillator light yield measurements. Digitized waveform pulse height values are only proportional to the amount of scintillation light if the temporal shape of the scintillation pulse is independent of the amount of energy deposited. Finally, this is not the case for scintillation pulses resulting from fast neutron interactions in organic scintillators. Authors measuring proton light yield should therefore report pulse integral values and ensure that the integration length is long enough to capture most of the scintillation light.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Synthesis and processing of lithium-loaded plastic scintillators on the kilogram scale

Plastic scintillators that can discriminate between gamma rays, fast neutrons, and thermal neutrons were synthesized and characterized while considering the performance at the kilogram scale. The synthesis and processing of these plastic scintillators on the kilogram scale required examination of several factors. The examination of these factors was necessitated by the inclusion of 0.1 wt.% lithium-6 to enable detection of thermal neutrons. First, methacrylic acid was used as an additive to solubilize salts of lithium-6, which allow for a thermal-neutron capture reaction that produces scintillation light following energy transfer. Second, a trade-off between scintillation performance and processability was considered because the increasing content of the methacrylic acid that aided processability resulted in a sharp decrease in the light output. The use of small amounts of methacrylic acid (≤3 wt.%) resulted in better performance but required high processing temperatures. At large scales, these high temperatures could initiate exothermic polymerization that results in premature curing and/or defects. Additionally, the deleterious effects of the methacrylic acid may be mitigated by using m-terphenyl as a primary dye rather than 2,5-diphenyloxazole (PPO), which has been traditionally used in organic scintillators. Finally, the curing environment was controlled to avoid defects like cracking and discolouration​ while maintaining solubility of dopants during curing. For scintillators that were produced from kilogram-scale batches of precursors, the effective attenuation of scintillation light was characterized.

36 MATERIALS SCIENCE↗

Crystal Growth Scale-Up and Stability of RbSr 2 X 5 :Eu Scintillators

The discovery and development of new scintillation materials support national security needs. In these applications, large volumes of scintillator crystals are needed to achieve efficient screening for contraband. Therefore, one important step in the discovery of new scintillator compositions is testing their feasibility for scale-up and their stability. In this work, high-quality Ø22 mm crystals of two new scintillators RbSr 2 Br 5 :Eu and RbSr 2 I 5 :Eu were grown via the Vertical Bridgman method, and their scintillation properties were characterized. Here, the Ø22 mm RbSr 2 I 5 :Eu crystals could be grown with fast translation rates up to 3.5 mm/h. Both RbSr 2 Br 5 :Eu and RbSr 2 I 5 :Eu had high scintillation performance, including light yields of 46,000 and 61,000 ph/MeV, respectively, for Ø22 × 35 mm crystals. Additionally, properties related to physical stability were investigated, including the coefficients of thermal expansion via high-temperature X-ray diffraction (HTXRD) as well as moisture sensitivity. HTXRD confirmed the absence of solid–solid phase transitions and showed that RbSr 2 Br 5 had minimal thermal expansion anisotropy compared to RbSr 2 I 5 and some other inorganic metal halide scintillators, which favors the growth of large-sized crystals.

36 MATERIALS SCIENCE↗

Vertically Self-Oriented, Ultrafast 1D ZnO:Li Nanorods as Scintillators for Thermal Neutron Detection

Detection of special nuclear materials (SNMs) is of vital importance in the prevention of nuclear terrorism and to secure states’ national security. Neutron detection is a particularly useful tool to identify SNM, and neutron-sensitive scintillators have many promising properties, such as ease of use, good time resolution, and high detection efficiency. In this work, we develop highly stable, self-oriented, ultrafast 1D ZnO:Li (and codoped with Al, Ga, and In) nanorods (NRs) as thermal neutron-sensitive scintillators. Lithium-6 has high thermal neutron cross section for the (n, α) reaction in ZnO:Li scintillators which have a vertical nano array design greatly increasing the effective surface area and scintillation efficiency. Cost-effective low-temperature (95 °C) hydrothermal growth is used to obtain highly crystalline ZnO:Li nano scintillators by combining nuclear range data and electron transport mechanisms. Among the studies using low-temperature hydrothermal synthesis and a relatively low annealing temperature (≈350 °C) along with optimized NRs (length ≈ 5–8 μm, mean diameter ≈ 700 nm) for thermal neutron detection, this study reports the shortest scintillation decay time (≈ 470 ps) so far to the best of our knowledge. In conclusion, this nano array scintillator combines the advantages of a low-cost growth technique with environmentally friendly and widely available materials.

Ions↗