At-Speed Defect Localization by Combining Laser Scanning Microscopy and Power Spectrum Analysis.
Abstract not provided.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Abstract not provided.
The strongly constrained and appropriately normed (SCAN) meta-GGA exchange–correlation functional is constructed as a chemical environment-determined interpolation between two separate energy densities: one describes single-orbital electron densities accurately and another describes slowly varying densities accurately. To conserve constraints known for the exact exchange–correlation functional, the derivatives of this interpolation vanish in the slowly varying limit. While theoretically convenient, this choice introduces numerical challenges that degrade the functional’s efficiency. We have recently reported a modification to the SCAN meta-GGA, termed restored-regularized-SCAN (r 2 SCAN) , that introduces two regularizations into SCAN, which improve its numerical performance at the expense of not recovering the fourth order term of the slowly varying density gradient expansion for exchange. Here, we show the derivation of a progression of density functional approximations [regularized SCAN (rSCAN), r++SCAN, r 2 SCAN, and r 4 SCAN] with increasing adherence to exact conditions while maintaining a smooth interpolation. The greater smoothness of r 2 SCAN seems to lead to better general accuracy than the additional exact constraint of SCAN or r 4 SCAN does.
Abstract INTRODUCTION In multicenter Alzheimer's disease studies, amyloid positron emission tomography (PET) visual reads are typically performed centrally by a few experts. Incorporating a broader reader network enhances scalability and generalizability. METHODS Ten neuroimaging experts from eight Alzheimer's Disease Research Centers (ADRCs) visually read 180 amyloid PET scans (30 scans and 15 duplicate scans for each of four tracers, imaged across a wide variety of scanners), using preferred reading software without anatomical imaging or quantitation. Scans were classified as elevated or non‐elevated per tracer‐specific criteria. Inter‐ and intra‐rater agreement was assessed. RESULTS Inter‐rater agreement was substantial (Fleiss’κ = 0.78), with full consensus on 69% of scans. Inter‐rater reliability was substantial to perfect across tracers (Fleiss’κ = 0.70–0.87). Intra‐rater agreement was substantial to perfect (Cohen'sκ = 0.79‐1). Scans with intermediate (10–40 Centiloid) quantitation had lower reader agreement. DISCUSSION A multicenter expert network achieved substantial agreement classifying amyloid PET scans. These scans provide a standard for reader training and reliability assurance in future studies. Highlights Calibration methods ensure reliable amyloid positron emission tomography (PET) visual reads across multiple raters. Substantial agreement is possible across readers using their preferred tools. Agreement is also substantial regardless of the amyloid PET tracer used. Scans with intermediate (10–40 Centiloid) quantitation have lower reader agreement. The calibration set will become a training tool for amyloid PET visual read studies.
Structured light scanning is used to create a digital twin of a manufactured part, where features are extracted to determine if the part meets the designer’s intent and required tolerances. This paper describes repeatability and reproducibility analyses for a commercially-available structured light scanning system and measurement artifact. The repeatability study used five repeated scans at 15 measurement positions. Repeatability was assessed by randomly selecting one of the five scans at each of the 15 positions and creating a part mesh. This process was performed 50 times and the statistics for the dimension variations were calculated to isolate the scanning effects only. The same sequence was then performed for 10 of the 15 positions and five of the 15 positions to evaluate the repeatability sensitivity to the number of measurement positions. Reproducibility was assessed by selecting 15 positions to create a mesh and repeating the 15-position measurement sequence 10 times using different positions for each mesh construction. The statistics for the dimension variations were then calculated. This incorporated the effects of both scanning and the position and orientation of the part relative to the scanner. This sequence was repeated for 10-position and five-position scans to evaluate the corresponding sensitivity. Finally, the artifact dimensions from structured light scanning were compared to coordinate measuring machine measurements of the same features.
Background: The quality of Digital Volume Correlation (DVC) full-field displacement measurements depends directly on the characteristics of the X-ray Computed Tomography (XCT) equipment, and scan procedures used to acquire the tomographic images. Objective: In this work, we seek to experimentally study the effects of XCT equipment and tomographic scan procedures on the quality of these images for DVC analysis, and to survey the level of DVC error that may be achieved using standard XCT operating procedures. Methods: Six participants in an interlaboratory study acquired high-quality XCT scans of a syntactic foam before and after rigid body motion. The resulting images were correlated using commercial DVC software to quantify error sources due to random image noise, reconstruction artifacts, as well as systematic spatial or temporal distortion. Results: In the absence of rigid body motion, the standard deviation of the displacement measurements ranged from 0.012 to 0.043 voxels using a moderate subvolume size, indicating that subvoxel measurement resolution could readily be achieved with a variety of XCT equipment and scan recipes. Comparison of consecutive scans without rigid body motion showed transient dilatational displacement gradients due to self-heating of the X-ray source and/or thermal expansion of the foam. Evaluation of the scans after rigid body motion showed significant, machine-specific spatial distortion in the displacement fields of up to 0.5 voxels; new approaches to remove this error need to be developed. Conclusions: Analysis of the scan protocols used in the interlaboratory study, as well as a complementary parametric sensitivity study, showed that the DVC error was strongly influenced by the XCT equipment, but could be mitigated by adjusting the total scan duration.
The Ka-Band Scanning ARM Cloud Radar (KASACR) records cloud properties. ARM's scanning cloud radars are dual-frequency, dual-polarization Doppler radars mounted on a common scanning pedestal. Each pedestal includes a Ka-band radar (2kW peak power) and the deployment location determines whether the second radar is a W-band (1.7 kW peak power) or an X-band (20 kW peak power). Beamwidths for Ka-bands paired with W-bands are roughly matched at 0.3 degrees. The X-band beamwidth is approximately 1 degree. Due to the narrow antenna beamwidth, ARM’s scanning cloud radars use scanning strategies unlike typical weather radars. Rather than focusing on plan position indicator, or PPI, scans, the KASACR uses range height indicator, or RHI, scans at numerous azimuths to obtain cloud volume data. Measurements collected with the KASACR are copolar and cross-polar radar reflectivity, Doppler velocity, spectra width and spectra when not scanning, and linear depolarization ratio. KASACR data from the 2018–2019 Cloud, Aerosol, and Complex Terrain Interactions (CACTI) field campaign in Argentina are now available as b1-level products. Building on the original CACTI operational data, the b1-level products feature improved data quality resulting from extensive analyses and corrections. The data are cross-calibrated to a common point, datastreams are corrected for operational issues that occurred during the campaign, and several data quality masks and basic derived products are incorporated. For more information, read the CACTI radar b1-level processing report.
The Ka-Band Scanning ARM Cloud Radar (KASACR) records cloud properties. ARM's scanning cloud radars are dual-frequency, dual-polarization Doppler radars mounted on a common scanning pedestal. Each pedestal includes a Ka-band radar (2kW peak power) and the deployment location determines whether the second radar is a W-band (1.7 kW peak power) or an X-band (20 kW peak power). Beamwidths for Ka-bands paired with W-bands are roughly matched at 0.3 degrees. The X-band beamwidth is approximately 1 degree. Due to the narrow antenna beamwidth, ARM’s scanning cloud radars use scanning strategies unlike typical weather radars. Rather than focusing on plan position indicator, or PPI, scans, the KASACR uses range height indicator, or RHI, scans at numerous azimuths to obtain cloud volume data. Measurements collected with the KASACR are copolar and cross-polar radar reflectivity, Doppler velocity, spectra width and spectra when not scanning, and linear depolarization ratio. KASACR data from the 2018–2019 Cloud, Aerosol, and Complex Terrain Interactions (CACTI) field campaign in Argentina are now available as b1-level products. Building on the original CACTI operational data, the b1-level products feature improved data quality resulting from extensive analyses and corrections. The data are cross-calibrated to a common point, datastreams are corrected for operational issues that occurred during the campaign, and several data quality masks and basic derived products are incorporated. For more information, read the CACTI radar b1-level processing report.
Disclosed here is a scanning probe microscope system and method for operating the same for producing scanning probe microscope images at fast scan rates and reducing oscillation artifacts. In some embodiments, an inverse consistent image registration method is used to align forward and backward scan traces for each line of the scanning microscope image. In some embodiments, the aligned forward and backward scan traces are combined using a weighting factor favoring the scan trace with higher smoothness. In some embodiments, the scanning probe microscope image is a potentiometry map and a method is provided to extract from the potentiometry map a conductivity map.
Image plates (IPs), or phosphor storage screens, are a technology employed frequently in inertial confinement fusion (ICF) and high energy density plasma (HEDP) diagnostics because of their sensitivity to many types of radiation, including, x rays, protons, alphas, beta particles, and neutrons. Prior studies characterizing IPs are predicated on the signal level remaining below the scanner saturation threshold. Since the scanning process removes some signal from the IP via photostimulated luminescence, repeatedly scanning an IP can bring the signal level below the scanner saturation threshold. This process, in turn, raises concerns about the signal response of IPs after an arbitrary number of scans and whether such a process yields, for example, a constant ratio of signal between the nth and n + 1st scan. Here, the sensitivity of IPs is investigated when scanned multiple times. It is demonstrated that the ratio of signal decay is not a constant with the number of scans and that the signal decay depends on the x-ray energy. As such, repeatedly scanning an IP with a mixture of signal types (e.g., x ray, neutron, and protons) enables ICF and HEDP diagnostics employing IPs to better isolate a particular signal type.
SCAN+rVV10 has been demonstrated to be a versatile van der Waals (vdW) density functional that delivers good predictions of both energetic and structural properties for many types of bonding. Recently, the r 2 SCAN functional was devised as a revised form of SCAN with improved numerical stability. In this work, we refit the rVV10 functional to optimize the r 2 SCAN+rVV10 vdW density functional and test its performance for molecular interactions and layered materials. Our molecular tests demonstrate that r 2 SCAN+rVV10 outperforms its predecessor SCAN+rVV10 in both efficiency (numerical stability) and accuracy. This good performance is also found in lattice-constant predictions. In comparison with benchmark results from higher-level theories or experiments, r 2 SCAN+rVV10 yields excellent interlayer binding energies and phonon dispersions for layered materials.
In 2023, the Technologist in Communities (TIC) program hosted its inaugural scanning tour across the American Southwest, with a goal of investigating the region's leading public mobility systems and their integration with on-demand public mobility services. The scanning tour concept was inspired by and named after a U.S. Department of Transportation Federal Highway Administration practice of hosting "scanning tours," both domestically and abroad, to explore innovative transportation practices throughout the 1990s and early 2000s. Guided by the idea that "seeing is believing," scanning tours created opportunities for government and industry representatives to collectively experience new technologies and best practices firsthand. In 2023, the National Renewable Energy Laboratory (NREL) followed suit by leading the inaugural TIC scanning tour. TIC, part of the Technology Integration program within the U.S. Department of Energy's (DOE's) Vehicle Technologies Office, supports positive energy and mobility outcomes in communities across rural to urban contexts. TIC enables technical experts to work directly with leaders and stakeholders in communities and assist them in implementing promising new technologies. This first TIC scanning tour invited NREL, DOE, and industry experts to survey innovative public mobility practices and their integration into public transit systems across the Southwest. The tour's goals included examining the state of innovation in public mobility in cities, communities, and airports; facilitating collaboration between entities; and sparking potential new partnerships. The following report summarizes key findings from the scanning tour.
Near-field X-ray speckle tracking has been used in phase-contrast imaging and tomography as an emerging technique, providing higher contrast images than traditional absorption radiography. Most reported methods use sandpaper or membrane filters as speckle generators and digital image cross-correlation for phase reconstruction, which has either limited resolution or requires a large number of position scanning steps. Recently, we have proposed a novel coded-mask-based multi-contrast imaging (CMMI) technique for single-shot measurement with superior performance in efficiency and resolution compared with other single-shot methods. We present here a scanning CMMI method for the ultimate imaging resolution and phase sensitivity by using a coded mask as a high-contrast speckle generator, the flexible scanning mode, the adaption of advanced maximum-likelihood optimization to scanning data, and the multi-resolution analysis. Scanning CMMI can outperform other speckle-based imaging methods, such as X-ray speckle vector tracking, providing higher quality absorption, phase, and dark-field images with fewer scanning steps. Scanning CMMI is also successfully demonstrated in multi-contrast tomography, showing great potentials in high-resolution full-field imaging applications, such as in vivo biomedical imaging.
This paper presents an impedance scan study on the real-world power system in Australia that has observed 17 to 20 Hz intermittent subsynchronous oscillations. Through the impedance scan of each of the IBRs, both individually and collectively, potential resonance modes are identified. The impedance scans were carried out using electromagnetic transient PSCAD models of the network. The network comprises of site-specific, black-boxed models of IBRs supplied by the generators. The impedance scan approach was divided in three major steps: (1) the first step is to identify IBRs where impedance analysis needs to be performed based on the magnitude of oscillations observed at their points of interconnection (POIs); (2) the second step focuses on performing impedance scans at selected IBRs in single-machine infinite-bus (SMIB) configuration to identify internal resonance modes of an IBR and to evaluate if any of these modes become unstable under certain grid conditions; (3) the third step performs impedance scans at a few selected IBRs while connected to the wider network model to obtain the impedance response of both the IBR and the grid - this step evaluates control interactions among IBRs. The impedance scan study found that a few IBRs have an underdamped resonance mode at around 17 Hz, which becomes unstable under a certain operating condition. Another interesting finding was that certain IBRs increase the effective grid impedance seen by another IBR in proximity for a particular operating condition. Under this operating condition, the resulting subsynchronous oscillation mode is more pronounced due to a combination of control interactions among IBRs through the transmission network under study and a resonance mode inside the IBRs.
Laser powder bed fusion (L-PBF) has emerged as one of the mainstream additive manufacturing approaches for fabricating metal parts with complex geometries and intricate internal structures. However, large deformation associated with rapid heating and cooling can lead to build failure and requires post-processing which may increase manufacturing cost and prolong the production period. Here in this work, an island scanning pattern design method is proposed to optimize the scanning direction of each island in order to reduce part deformation after cutting off the build platform. The objective of this optimization is to minimize the upward bending of the part after sectioning, which allows the part deformation to satisfy the tolerance requirement or reduce the post heat treatment time. Inherent strain method is employed in the sequential finite element analysis consisting of layer-by-layer activations and sectioning for fast residual distortion prediction. Full sequential sensitivity analysis for the formulated optimization is provided to update the island scanning directions. To show the feasibility and effectiveness of the proposed method, the scanning patterns of a block structure and a connecting rod were designed and parts were fabricated using an open architecture L-PBF machine. The fabrication experiments demonstrated that the residual deformation of both parts fabricated by optimized scanning pattern can be reduced by over 50% compared to the initial scanning patterns, which demonstrate the effectiveness of the proposed method.
This study investigated the effects of laser scanning speed on the microstructure, phase transformation and properties of NiTi alloys fabricated by laser powder bed fusion (LPBF). In this study, the contributions of metallurgical factors under different scanning speeds, such as Ni evaporation, Ni4Ti3 precipitation, dislocations and internal stress, to the transformation temperature and transformation latent heat were clarified through specially designed experiments. Ni evaporation is found to have the most profound effect, followed by precipitation. Increasing scanning speed is found to reduce Ni loss, thus cause less increase in the transformation temperature and transformation heat of the LPBF-NiTi alloys. Increasing scanning speed also increases the microstructure non-uniformity and thus widens the transformation temperature interval. The orientations of residual stress exhibit strong crystallographic stiffness dependence. The LPBF-NiTi alloys with different scanning speeds all exhibited high strains (>13.4%) and excellent shape memory effect. A LPBF-NiTi honeycomb structure exhibited 96% shape recovery rate after a 60% pre-compressive deformation. Besides, there is an optimum scanning speed for minimum porosity and smallest average pore size. However, the pore structure is found to have weak influence on the tensile behaviour of the LPBF-NiTi alloys, possibly due to the high defect tolerance of the martensitic transformation.
The parallel development of ultramicroelectrodes (UMEs) and groundbreaking scanning probe microscopy techniques in the late 1980s led to the development of the scanning electrochemical microscope. Scanning electrochemical microscopy (SECM) was born from the idea of using a tiny electrode to measure the local electrochemical behavior at operating electrodes. From its foundations, the technique displayed an inherent versatility in measuring sample properties beyond topography. It allowed experimenters to measure and map chemical reactions occurring at diverse interfaces, from inspecting the reversibility of redox mediators at metal electrodes, to detecting the hallmarks of cellular respiration on living plant leaves. Related but distinct electrochemical scanning probe techniques, such as electrochemical atomic force microscopy (EC-AFM), scanning ion conductance microscopy (SICM), and scanning electrochemical cell microscopy (SECCM) have developed in parallel. These techniques have demonstrated exquisite spatial resolution down to the nanoscale regime. However, it is the proposition of this review that SECM remains unmatched at revealing the chemical aspects of electrochemistry. Furthermore, it is our intention to review and demonstrate that the versatile architecture of SECM continues to evolve and address fundamental and emerging challenges in the fields of energy storage and conversion, chemical biology, materials science, and environmental chemistry, among others.
In the realm of X-ray ptychography experiments, a considerable amount of ptychography scans are typically performed within a field of view encompassing the target sample. While it is crucial to obtain overlapping scans in small increments over the region of interest for achieving high-resolution sample reconstruction, a significant number of these scans often redundantly measure the empty background within the wide field of view. To address this inefficiency, an innovative algorithm is proposed that introduces automatic guidance for data acquisition. The algorithm first directs the scan point to actively search for the object of interest within the field of view. Subsequently, it intelligently scans along the perimeter of the sample, strategically acquiring measurements exclusively within the boundary of the region of interest. By employing this approach, a reduction in the number of measurements required to obtain high-resolution reconstruction images is demonstrated, as compared with conventional raster scanning methods. Furthermore, the automatic guidance provided by the algorithm offers the added advantage of saving valuable time during the reconstruction process. Through practical implementation on real experiments, these findings showcase the efficacy of the proposed algorithm in enhancing the efficiency and accuracy of X-ray ptychography experiments. This novel approach holds immense potential for advancing sample analysis and imaging techniques in various scientific disciplines.
The U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) User Facility (Mather and Voyles 2013) deployed the first ARM Mobile Facility (AMF1; Miller et al. 2016) near LaPorte, Texas to support the Tracking Aerosol Convection Interactions Experiment (TRACER) (Jensen et al. 2025) near Houston, Texas. From October 2021 to September 2022, AMF1 was deployed to 29.67° N, 95.06° W near LaPorte, Texas and the 2nd Generation C-band Scanning ARM Precipitation Radar (CSAPR2) was deployed to a supplementary site at 29.53° N, 95.28° W (Figure 1). During an intensive operational period (IOP) from 1 June to 30 September 2022, the CSAPR2 sampled precipitation echoes in an adaptive scanning mode following the Multisensor Agile Adaptive Scanning (MAAS) framework (Kollias et al. 2020). MAAS helped optimize the CSAPR2 scan strategy to perform frequent plan position indicator (PPI) and range height indicator (RHI) scans (Lamer et al. 2023). Details of the CSAPR2 scanning, data processing, and calibration procedures used by the principal investigator (PI), and the PI data files are described by Oue et al. (2023). Details of the CSAPR2 operational performance, ARM data processing and correction procedures, and data quality masks are described by Feng et al. (2024a).