sCO2 Research at NREL

This panel presentation gives a brief overview of and links to NREL's recent research related to sCO2 cycles. This includes PTES, PTES with CSP, Gen3 Gas, Gen3 Liquid, cycle design-point modeling, and cycle off-design modeling.

concentrating solar power↗

Local Heat Transfer Measurements in Cooler for sCO2 Power Cycles with Dilute Nitrogen and Argon Impurities

An experimental investigation of heat transfer in CO2 and CO2/N2 and CO2/argon mixtures undergoing cooling near the pseudocritical temperature has been conducted. The conditions are representative of direct sCO2 cycle coolers. Three tubing test articles were tested: conventional drawn tubing, an additively manufactured tube with a square cross section, and an additively manufactured tube with a square cross section and ribs angled 60° relative to the flow direction. The axial heat transfer coefficient distribution was determined with local wall temperature measurements. This work concludes that dilute concentrations (< 2%) of nitrogen and argon have a negligible impact on heat transfer coefficient and on friction factor.

Searle, Matthew↗

Off-Design Load Analysis of sCO2 Bottoming Cycle for a Natural Gas Combined Cycle Power Plant with Carbon Capture

This work starts with the optimal design from Pidaparti et. al (2024) to analyze the off-design performance of the power plant from 100% down to 50% load. The main operational findings and plant-efficiency for off-load conditions while maintaining the target CO2 capture rate are presented. The goal of the work is to determine if there is a relative advantage or disadvantage for the sCO2 bottoming cycle compared to the steam bottoming cycle in terms of reduced load efficiency performance for the NGCC with carbon capture. Results show nearly identical efficiency profiles for the two cases from 100% to 50% load.

Chinen, Anderson Soares↗

A Tracer Study on sCO2 Corrosion with Multiple Oxygen-Bearing Impurities

Abstract Several modern power production systems utilize supercritical CO 2 (sCO 2 ), which can contain O 2 and H 2 O as impurities. These impurities may degrade the compatibility of structural alloys through accelerated oxidation. However, it remains unclear which of these impurities plays a bigger role in high-temperature reactions taking place in sCO 2 . In this study, various model and commercial Fe‐ and Ni‐based alloys were exposed in 300 bar sCO 2 at 750 °C to low levels (50 ppm) of O 2 and H 2 O for 1,000 h. 18 O-enriched water was used to enable the identification of the oxygen source in the post-exposure characterization of the samples. However, oxygen from the water did not accumulate in the scale, which consisted of Cr 2 O 3 in the cases where a protective oxide formed. A 2wt.% Ti addition to a Ni-22%Cr model alloy resulted in the formation of thicker oxides in sCO 2 , while a 1wt.% Al addition reduced the scale thickness. A synergistic effect of both Al and Ti additions resulted in an even thicker oxide than what was formed solely by Ti, similar to observations for Ni-based alloy 282.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Optimization and Techno-Economic Comparison of Regenerators and Recuperators in sCO2 Recompression Brayton Cycles for Concentrating Solar Power Applications

Supercritical CO2 power cycles might be capable of providing the cost reductions and efficiency improvements necessary to reach concentrating solar power (CSP) cost targets, but require large, highly effective recuperators. Fixed-bed regenerators are a periodic heat exchanger that could be an effective yet low-cost alternative to these recuperators. This study presents a techno-economic comparison of regenerators and recuperators for a 100 MWe supercritical CO2 power cycle for CSP applications. We quantify the levelized cost of energy (LCOE) for the power plant with both types of heat exchangers, and explore sensitivity of LCOE to parameters such as CSP-specific capital costs, power cycle component capital costs, and regenerator valve replacements costs. Results indicate that the incumbent printed circuit heat exchangers achieve the lowest LCOE, unless the upper extreme of PCHE capital cost and lower extremes of regenerator and valve capital and O&M costs are realized. Sensitivity analysis also illustrates that the primary heat exchanger cost is the most influential of power cycle components, and that CSP component capital cost is more influential than power cycle capital costs. This illustrates the importance of reducing the cost of heliostats, receivers, and thermal energy storage for achieving CSP LCOE targets.

OTHER INSTRUMENTATION,SOLAR ENERGY↗

Design of an Additively Manufactured Recuperator With 800 °C Inlet Temperature for sCO2 Power Cycle Application

Abstract Recuperators with design temperatures at and above 800 °C can further increase the thermal efficiency of supercritical CO2 power cycles by enabling higher turbine exhaust temperatures. Mar-M247 is a well-suited nickel-based superalloy for high temperature service due to its high creep strength that prevents excessive material thickness being required for pressure containment. Additive manufacturing using a high-speed laser-directed energy deposition (L-DED) process presents a promising solution, with build trials demonstrating the ability to produce nonconventional flow channels for enhanced heat transfer. A design process is presented that includes aerothermal and mechanical evaluation to maximize performance within the constraints of the manufacturing process. A 2-D heat transfer network and pressure drop code allows prediction of flow distribution and its effect on overall thermal performance. Established literature correlations, along with CFD simulation, inform the prediction of heat transfer coefficients and friction factors for the flowpaths and enhancement features in the heat exchanger core. Mechanical evaluation using finite element analysis (FEA) modeling with the intent of the ASME Boiler & Pressure Vessel Code (BPVC) Section VIII, Div. 2 assesses the operational safety of the design. The detailed design features annular finned passages that take advantage of helical flow paths to distribute the flow from separated headers to shared heat transfer surfaces. Performance predictions for the recuperator at a 50 kW scale provide insights into the feasibility of the additively manufactured (AM) process to produce recuperators on a commercial scale that extend existing operating envelopes.

Engineering↗

MODELING AND TESTING OF A NOVEL ULTRA-LOW TEMPERATURE SCO2 OPPOSING PISTON EXPANDER

The Flameless Pressurized Oxy-Combustion (FPO) cycle, a novel flexible fuel technology, is being developed into a large pilot. This effort seeks to complete the preliminary engineering and planning of a 25 MWth Pilot Plant that will demonstrate the technology for scale-up to a commercial unit. The technology, pioneered by ITEA at the 5 MWth scale, must be brought to a higher technology readiness level (TRL) to be viable at the commercial scale. The 25 MWth pilot cycle was optimized for cost and technology development and demonstration. Preliminary drawings, layouts, and plans were defined. Process flow diagrams were used to describe the pilot configuration in greater detail. A heat and mass balance with stream data was created. A master equipment list specified the operating conditions for major pieces of equipment within the pilot using this heat and mass balance. The 25 MWth FPO pilot is assessed for environmental performance. A test campaign is developed to assess the type of test and number of hours required for pilot demonstration. The environmental performance is compared against projected performance at the commercial scale. This project builds upon extensive evaluation of the techno-economic performance of the FPO technology already performed by ITEA. This includes system improvements, such as the addition of a turbo-expander to the flue gas stream. Some of the performance-enhancing components are not as well defined as others. The primary goal of this effort was to bring all of the core cycle components to the same level of design maturity. A techno-economic assessment (TEA) evaluated the FPO technology at the commercial scale in comparison to the NETL baseline cases. The reference plants were used in combination with proprietary equipment estimates to build a plant capital cost and cost of electricity evaluation. FPO performed better than the sub-bituminous post-combustion capture cases. Further preliminary estimates of improvements to the FPO cycle show even further gains when compared to conventional carbon capture methods.

01 COAL, LIGNITE, AND PEAT↗

Gen3CSP sCO2 Loop Scope of Supply (V0.0.3)

The Generation 3 Concentrating Solar Power (Gen3CSP) supercritical carbon dioxide (sCO 2 ) coolant loop, typically referred to here as the `sCO 2 loop,' is designed to continuously remove heat from a primary heat exchanger (PHX) subsystem through a flow of sCO 2 as a substitute for a sCO 2 Brayton power cycle as shown in Figure 1-1. This system is designed to function as a pumped coolant loop operating at a high baseline pressure with a high degree of flexibility, stability, and autonomy to simplify operation of a Gen3CSP Topic 1 team Phase 3 pilot plant. The complete system includes a dedicated inventory management module to fill the main flow loop with CO2 and recovery CO2 during heating and venting operations to minimize the delivery of CO2 to the site.

20 FOSSIL-FUELED POWER PLANTS↗