Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ScO”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Structure of the (110) Ln ScO 3 ( Ln =Gd,Tb,Dy) surfaces

The surface reconstruction on the (110) surface of LnScO 3 (Ln=Gd,Tb,Dy) has been investigated using x-ray photoelectron spectroscopy, atomic force microscopy, and transmission electron diffraction coupled with higher-level density-functional theory methods. The experimental techniques generate constraints on the surface chemistry and structure that are used to inform the theoretical comparison of a number of potential surface structures. The resulting structure is then compared to experimental aberration-corrected transmission electron microscopy results using multislice simulation. The surfaces of both single-crystalline substrates and hydrosauna synthesized nanoparticles exhibit a Sc-rich double layer with a Sc 3 O 4 termination.

36 MATERIALS SCIENCE↗

Parametric Modeling and Economic Analysis of a 2MW th 3-Stream sCO 2 Heat Exchanger

Here, this paper presents the design and cost optimization of a novel 2MW th 3-stream sCO2 plate-fin heat exchanger. This heat exchanger design is unique in that it uses reduced metal oxide particle-to-sCO2 heat exchanger for cost-effective energy storage applications. The design uses low velocity, laminar air as the re-oxidizing reactant to transfer the heat of the re-oxidizing reaction to a sCO2 power loop. The design of the heat exchanger is based on a 2-D, 3-fluid plate/fin heat transfer model. The model parameterizes the size, shape, and number of passages of the heat exchanger to calculate the temperature profile, pressure drop, and fluid velocities of all three fluids. Global heat exchanger parameters such as the effectiveness and total heat transferred to the sCO2 are then calculated for overall performance. Due to the value and increased use of sCO2 heat exchangers in power cycles, a cost model of the system based on the unique high temperature/high pressure operating conditions was created using quotes from reference projects and market analysis. These quoted air-to-sCO2 heat exchangers are then processed using multiple weighting factors pertinent to heat exchanger design, including heat exchanger type, maximum temperature, differential pressures, fluids, duty, and more. These factors are then used in an exponential function in order to generate a parameterized cost curve. The design and cost of the heat exchanger are then optimized using the SMPSO genetic algorithm in Python. The optimization objectives for the system are to maximize the overall system effectiveness, including an air recuperator for preheating, and to minimize unit costs. Additional constraints are added to the system for the sCO2 and air pressure drops, air velocity to reduce particle entrainment, and the length and volume of the heat exchanger.

Cost Model↗

SCO#1197 Addendum #4 OSR Characterization Database (Test Report)

A test plan was developed and approved in June of 2022. Testing was successfully performed to verify the functions of Version 2.0 of the OSR Characterization database. Checks verified that data remains consistent to tests previously performed using Microsoft Access® 2003, 2010 and 2016.

97 MATHEMATICS AND COMPUTING↗

Technologies for Enhanced Condensation in sCO 2 Power Cycles

The direct fired supercritical carbon dioxide power cycle has higher efficiency, compact machinery footprint, and is resilient under transient operation. It has been shown that improving the cycle main cooler significantly improves performance, including increased cycle efficiency, decreased cost of electricity and decreased cooler outlet temperatures. One way to improve this process is through enhanced condensation techniques and management of condensation fluid. This manuscript provides an overview of active and passive enhanced condensation technologies, with a focus on the passive approaches. compared to passive approaches, active approaches can have higher heat transfer enhancement, but the additional power and infrastructure can be problematic. The passive approaches identified include microfins (helical and herringbone), corrugated tubing, dimpled tubing and pin fins. After comparison it is found that the microfin geometry has the best performance characteristics followed by the additively manufactured pin fins. It is noted that current literature around additively manufactured enhancements is lacking, and investigation of conventional as well as novel geometries fabricated in this manner may be worth further investigation. Benchmark correlations for these geometries are identified and their limitations outlined. For further investigation, a matrix of test articles is presented for possible experimentation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Integrated Optimization and Control of a Hybrid Gas Turbine/sCO 2 Power System

During phase-I, the project team led by Echogen Power Systems (EPS) had two primary objectives based on investigating the application of gas turbines with supercritical carbon dioxide (sCO 2 ) power cycles. The first objective was to improve the overall efficiency and performance of a hybrid gas turbine/sCO 2 power system through a joint optimization of the two subsystems (gas turbine and sCO 2 power cycle) using non-linear optimization techniques that simultaneously evaluate thermal performance of the combined cycle. The hybrid power system included several points of interaction, including (but not limited to) gas turbine exhaust, fuel heating, inlet chilling and turbine cooling. The second objective was to establish a baseline transient response model of the hybrid power system and a notional microgrid and begin steps to integrate the control systems of the three major elements (gas turbine, sCO 2 cycle and grid controller). The project team established a baseline performance for a combined cycle power plant using a production gas turbine and scaled sCO 2 power cycle only utilizing exhaust heat recovery. Echogen’s non-linear techno-economic optimization code was extended by adding gas turbine component models derived from a in-house developed gas turbine design code. With the two cycles coupled by the gas turbine exhaust, design parameters of both cycles were allowed to vary simultaneously to determine performance opportunity versus isolated designs. Returning to the baseline gas turbine/sCO 2 power cycle transient models: Echogen had in-house developed sCO 2 cycle transient model in GT-Suite system simulation software, and had partnered with Siemens Finspång for gas turbine transient model, and Siemens PTI group to provide micro-grid load profile as well as hybrid power cycle generated load (power and frequency) analysis. The transient model for the SGT-750 Siemens gas turbine was a “black-box” functional mock-up interface (FMI) model developed by Siemens Industrial Turbomachinery in Finspång, Sweden. The SGT-750 is a twin-shaft gas turbine that produces 40 MW electricity with an efficiency of about 40% at ISO conditions. At 100% gas turbine throttle (load), the SGT-750 has average exhaust conditions of 114.6 kg/s and 469.8°C. The transient model for sCO 2 power cycle was developed by Echogen in GT-SUITE 1D system simulation software platform. The basic CO 2 flow circuit has single-shaft turbomachinery with net 11.5 MW electrical power output at design conditions. The power turbine has a double-ended shaft with one end connected to synchronous generator through a fixed-ratio gearbox. The other end of power turbine is connected to the compressor through a continuously variable transmission. The major components of the sCO 2 power cycle modeled include air cooled condenser/cooler, CO 2 compressor, recuperator, two waste heat exchanger coils, power turbine, continuous variable transmission, gearbox and generator. Integration of SGT-750 transient model and sCO 2 power cycle transient model was done in Matlab Simulink. In the integrated model, the gas turbine and sCO 2 power cycle interacted at two points, first one being the gas turbine exhaust gas flow rate and temperature, which were inputs to sCO 2 power cycle model. The second point was the distribution of micro-grid load demand signal between the SGT-750 generator and sCO 2 cycle generator. For a given combined-cycle load demand, the gas turbine load demand was equal to the total demand minus the sCO 2 cycle power generated. In the present study the integrated model was simulated for two cases of grid load demand: (i) for a step change, both positive-step and negative-step, in grid load demand (ii) for a micro-grid load demand curve provided by Siemens PTI group. Finally, the time series plots representing load demand versus integrated system response were presented including the sCO 2 power cycle control system performance plots. The actual generated power and frequency of both the generators, gas turbine and sCO 2 power cycle, was supplied to Siemens PTI group for dynamic grid assessment, results of which are provided in appendices.

03 NATURAL GAS↗

Supercritical Carbon Dioxide Primary Power Large-Scale Pilot Plant

The United States electrical power generation fleet encompasses a wide range of technologies, ranging from traditional combustion-based power generation, to nuclear power, to renewable energy. While the distribution of these assets continues to shift due to economic and regulatory influences, coal combustion continues to be a key part of the US energy portfolio. Despite the relative maturity of coal combustion technology, improvements in overall fuel-to-power efficiency and generation flexibility are still possible and will improve both the economic and environmental factors of coal combustion. Echogen Power Systems proposes to lead a world-class team including the University of Missouri, Electric Power Research Institute and Louis Perry Associates in the design, construction and operation of a 10MWe coal-fired supercritical carbon dioxide (sCO 2 ) large-scale pilot. This transformational technology uses sCO 2 as a working fluid instead of water to achieve high thermodynamic efficiencies that can significantly exceed advanced steam-Rankine cycles. Further, the compact nature of sCO 2 turbomachinery offers capital cost and footprint advantages, and the low maintenance of a water-free power cycle can significantly reduce operation and maintenance (O&M) costs over conventional steam-Rankine systems. Recent integration studies of sCO 2 with coal combustion power plants highlight the significant improvements in plant efficiency that sCO 2 can offer relative to even advanced steam Rankine cycles. At commercial scales, coal-sCO 2 plant net efficiency is predicted to be 39-44.0% (HHV), or 10-20% higher output than conventional steam-Rankine systems, which will significantly improve the competitiveness of coal-fired generation. This proposal builds upon projects previously funded by the Department of Energy, including DE-FE0025959 (High-Efficiency Thermal Integration of Closed Supercritical CO 2 Brayton Power Cycles with Oxy-Fired Heaters) and DE-NE0008470 (Conceptual Design for sCO 2 Power Cycle Test Facility). An appropriately-scaled and properly designed and operated pilot project is essential to overcome the natural risk-aversion of the power generation industry and project financing community. The 10 MWe coal-fired sCO 2 pilot power plant proposed herein will reduce the technical and economic risk of this transformational technology, enabling commercial deployment at the conclusion of the project. For the second phase of this project, Echogen lead a team that completed and refined the pilot system conceptual system and key component designs resulting in the completion of a front-end-engineering-design (FEED) study, completed the NEPA review process, completed the permitting process for construction and operation, refined the techno-economic analysis of the proposed system at commercial scale and received commitments for Phase III cost share. The end result of the program will be to demonstrate the technical and economic superiority of the sCO 2 power cycle for coal-fired operation. Major risk elements will have been retired with sufficient operation at high power to enable the power generation industry to move forward with the first commercial deployment of this transformational system.

01 COAL, LIGNITE, AND PEAT↗

Demonstration of a multi-channel fluidized bed particle–supercritical carbon dioxide heat exchanger for concentrating solar applications

High-temperature thermal energy storage in oxide particles at temperatures above 600°C can couple concentrated solar energy with high-efficiency thermal power cycles to provide dispatchable solar-driven electricity. Challenges remain in developing cost-effective primary heat exchangers, which require expensive alloys, to extract the high-temperature thermal energy from the particles to power cycle fluids, such as supercritical CO 2 (sCO 2 ) in recuperated Brayton cycles. To explore one pathway for cost-effective, high-temperature particle heat exchangers, the current study demonstrates a shell-and-plate, particle–sCO 2 heat exchanger with narrow- channel fluidized beds coupled with micro-channel sCO 2 flows in the heat exchanger walls. This study evaluates the feasibility of multiple parallel, narrow-channel fluidized beds in shell-and-plate particle–sCO 2 HXs, to achieve high bed-wall heat fluxes at elevated temperatures. A reduced-order model simulates the narrow- channel, fluidized-bed particle–sCO 2 heat exchanger to design the fluidized bed geometry, in terms of depth, height, and number of channels,for a nominal 40-kWth heat exchanger at particle and sCO 2 inlet temperatures up to 600 °C and 400 °C respectively. The resulting shell-and-plate heat exchanger design operates with bubbling fluidization of the downward-flowing oxide particles to enhance bed-wall heat transfer. The heat exchanger core is fabricated with etched sCO 2 micro-channels in thin wall plates that are diffusion bonded to spacer frames to form the shell-and-plate structure with 12 parallel, fluidized bed channels, 10.4 mm deep. The heat exchanger is tested at the National Solar Thermal Test Facility at Sandia National Laboratories with CARBOBEAD HSP particles at design particle flow rates of 0.20 kg s –1 and inlet temperatures up to 525 °C. Results show that fluidization across multiple parallel channel beds can maintain uniform particle inventory with a common freeboard zone above the heat exchanger core. Bubbling fluidization improves particle–wall heat transfer coefficients but also increases axial dispersion of particle thermal energy, which lowers the log- mean temperature difference such that total heat transfer remains relatively constant to within ±10% over a broad range of fluidization gas velocities. The axial dispersion required particle and sCO 2 flow rates to be increased by 25% over model-designed conditions to achieve the targeted 40 kWth, which indicates the importance of incorporating axial dispersion into heat exchanger design models and of deploying bed structures to suppress it. Furthermore, this study demonstrates the feasibility and preferred fluidizing gas conditions for particle heat exchangers for releasing high-temperature thermal energy storage systems.

14 SOLAR ENERGY↗

Cooperativity and Metal–Linker Dynamics in Spin Crossover Framework Fe(1,2,3-triazolate) 2

Cooperative interactions are responsible for the useful properties of spin crossover (SCO) materials–large hysteresis windows, critical temperatures near room temperature, and abrupt transitions–with hybrid framework materials exhibiting the greatest cooperativity and hysteresis of all SCO systems. However, little is known about the chemical origin of cooperativity in frameworks. Here, we present a combined experimental–computational approach for identifying the origin of cooperativity in the metal–organic framework (MOF) Fe(1,2,3-triazolate) 2 (Fe(TA) 2 ), which exhibits the largest known hysteresis window of all SCO materials and unusually high transition temperatures, as a roadmap for understanding the manipulation of SCO behavior in general. Variable-temperature vibrational spectroscopy provides evidence that “soft modes” associated with dynamic metal–linker bonding trigger the cooperative SCO transition. Thermodynamic analysis also confirms a cooperativity magnitude much larger than those of other SCO systems, while electron density calculations of Fe(TA) 2 support previous theoretical predictions that large cooperativity arises in materials where SCO produces considerable differences in metal–ligand bond polarities between different spin states. Taken together, this combined experimental–computational study provides a microscopic basis for understanding cooperative magnetism and highlights the important role of dynamic bonding in the functional behavior of framework materials.

36 MATERIALS SCIENCE↗

Machine Learning Prediction of the Experimental Transition Temperature of Fe(II) Spin-Crossover Complexes

Spin-crossover (SCO) complexes are materials that exhibit changes in the spin state in response to external stimuli, with potential applications in molecular electronics. It is challenging to know a priori how to design ligands to achieve the delicate balance of entropic and enthalpic contributions needed to tailor a transition temperature close to room temperature. Here, we leverage the SCO complexes from the previously curated SCO-95 data set [Vennelakanti et al. J. Chem. Phys. 159, 024120 (2023)] to train three machine learning (ML) models for transition temperature (T 1/2 ) prediction using graph-based revised autocorrelations as features. We perform feature selection using random forest-ranked recursive feature addition (RF-RFA) to identify the features essential to model transferability. Of the ML models considered, the full feature set RF and recursive feature addition RF models perform best, achieving moderate correlation to experimental T 1/2 values. We then compare ML T 1/2 predictions to those from three previously identified best-performing density functional approximations (DFAs) which accurately predict SCO behavior across SCO-95, finding that the ML models predict T 1/2 more accurately than the best-performing DFAs. In addition, we study ML model predictions for a set of 18 SCO complexes for which only estimated T 1/2 values are available. Upon excluding outliers from this set, the RF-RFA RF model shows a strong correlation to estimated T 1/2 values with a Pearson’s r of 0.82. In contrast, DFA-predicted T 1/2 values have large errors and show no correlation to estimated T 1/2 values over the same set of complexes. Overall, our study demonstrates slightly superior performance of ML models in comparison with some of the best-performing DFAs, and we expect ML models to improve further as larger data sets of SCO complexes are curated and become available for model training.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Scalable Compact Additively Manufactured Molten Salt to Supercritical Carbon Dioxide Heat Exchanger for Solar Thermal Application

Design of an additively manufactured molten salt (MS) to supercritical carbon dioxide (sCO 2 ) primary heat exchanger (PHE) for solar thermal power generation is presented. The PHE is designed to handle temperatures up to 720 °C on the MS side and an internal pressure of 200 bar on the sCO 2 side. In the core, MS flows through a three-dimensional periodic lattice network, while sCO 2 flows within pin arrays. The design includes integrated sCO 2 headers located within the MS flow, allowing for a counterflow design of the PHE. The sCO 2 headers are configured to enable uniform flow distribution into each sCO 2 plate while withstanding an internal pressure of 200 bar and minimizing obstruction to the flow of MS around it. The structural integrity of the design is verified on additively manufactured (AM) 316 stainless steel sub-scale specimens. An experimentally validated, correlation-based sectional PHE core thermofluidic model is developed to study the impact of flow and geometrical parameters on the PHE performance, with varied parameters including the mass flowrate, surface roughness, and PHE dimensions. A process-based cost model is used to determine the impact of parameter variation on build cost. The model results show that a heat exchanger with a power density of 18.6 MW/m 3 (including sCO 2 header volume) and effectiveness of 0.88 can be achieved at a heat capacity rate ratio of 0.8. As a result, the impact of design and AM machine parameters on the cost of the PHE are assessed.

14 SOLAR ENERGY↗

Narrow-Channel, Fluidized Beds for Effective Particle Thermal Energy Transport and Storage

Colorado School of Mines (Mines) led this program in collaboration with Sandia National Laboratories (Sandia) to characterize narrow-channel fluidized beds of aluminosilicate particles – supplied by Carbo Ceramics – as a means for releasing high-temperature thermal energy in particle heat exchangers and for capturing concentrated solar energy in indirect particle receivers. Single-channel, heat transfer experiments at Mines and reduced-order 1-D models and 3-D two-fluid, CFD models explored many aspects of counterflow, bubbling fluidized beds (net downward particle flow and upward gas flow) for enhancing particle-wall heat transfer at elevated temperatures. Results at Mines on single-channel test sections consistently showed that mild bubbling fluidization increases particle-wall heat transfer coefficients (h T,w ) regularly by more than 4.0x over h T,w values without fluidization at similar conditions (mean particle diameter d p , bed depth Δz b , and bed particle temperatures T p ). Insights from lab-scale tests and modeling studies provided Nusselt number correlations for h T,w and informed the design and fabrication (by Vacuum Process Engineering) of a nominal 40-kWth, particle-sCO 2 plate heat exchanger (HX) with 12 parallel narrow-channel, fluidized beds bounded by stainless-steel walls with embedded microchannels for high-pressure sCO 2 flows. Tests of the 40-kW th HX at the particle-sCO 2 HX test stand at Sandia's National Solar Thermal Test Facility (NSTTF) were limited, due to HX design, to particle inlet temperatures T p,in ≤ 520°C with maximum sCO 2 outlet temperatures T sCO2,out ≈ 440°C, which are well below design conditions for a primary HX in a sCO 2 power cycle for a Gen-3 concentrating solar power (CSP) plant. Total heat transfer $\dot{Q}_{HX}$ remains relatively constant with increased fluidization for fixed particle and sCO 2 inlet conditions because higher h T,w due to fluidization is offset by increased axial dispersion, which suppresses temperature differences between the particles and sCO 2 in the counterflow configuration. The axial dispersion reduces the effective overall heat transfer coefficient U based on T p,in to values around 200 W m -2 K -1 .

14 SOLAR ENERGY↗

Multi-fluid, earth battery energy systems and methods

The present disclosure relates to a system for storing and time shifting at least one of excess electrical power from an electrical power grid, excess electrical power from the power plant itself, or heat from a heat generating source, in the form of pressure and heat, for future use in assisting with a production of electricity. An oxy-combustion furnace is powered by a combustible fuel source, plus excess electricity, during a charge operation to heat a reservoir system containing a quantity of a thermal storage medium. During a discharge operation, a discharge subsystem has a heat exchanger which receives heated CO 2 from the reservoir system and uses this to heat a quantity of high-pressure, supercritical CO 2 (sCO 2 ) to form very-high-temperature, high-pressure sCO 2 at a first output thereof. The very-high-temperature, high-pressure sCO 2 is used to drive a Brayton-cycle turbine, which generates electricity at a first output thereof for transmission to a power grid. The Brayton-cycle turbine also outputs a quantity of sCO 2 which is reduced in temperature and pressure to a heat recuperator subsystem. The heat recuperator subsystem circulates the sCO 2 and re-heats and re-pressurizes the sCO 2 before feeding it back to the heat exchanger to be even further reheated, and then output to the Brayton-cycle turbine as a new quantity of very-high-temperature, high-pressure sCO 2 , to assist in powering the Brayton-cycle turbine.

Buschek, Thomas A.↗

Effect of annealing and supercritical CO 2 exposure at 750°C on the tensile properties of stainless steel and Ni-based structural alloys

Subsize dogbone tensile specimens of alloys 304H, 310HCbN, and 740H were exposed to 30 MPa supercritical CO 2 (sCO 2 ) for up to 4000 h at 750°C. Similar exposures in laboratory air were used to assess the specific role of sCO 2 exposure on the alloy tensile properties. Type 304H specimens were only embrittled by exposure in sCO 2 due to the formation of a thick Fe-rich oxide and C ingress in the bulk of the alloy. For 310HCbN and 740H, no effect of the sCO 2 environment was observed and a decrease of the alloy's ductility was associated with previously observed microstructure evolutions, for example, grain boundary carbide formation. The 740H was tested in the solution annealed condition and self-aging took place during 750°C exposures in sCO 2 and air with the formation of fine gamma prime precipitates leading to significant tensile strength increase. It was found that both 740H and 310HCbN have adequate sCO 2 compatibility for high-temperature commercial applications.

36 MATERIALS SCIENCE↗

Evaluation of coated steels in supercritical CO 2

The carburizing supercritical CO 2 (sCO 2 ) environment limits the use of lower cost steels in the lower temperature (450–650°C) portions of the sCO 2 Brayton cycle because of concerns about internal carburization and embrittlement. Results on a ferritic–martensitic steel and conventional and advanced austenitic steels at 450–650°C in 30 MPa sCO 2 with and without 1% O 2 and 0.1% H 2 O additions have indicated that sCO 2 environments will have lower maximum operating temperatures compared to steam plants. Pack Al and Cr coatings were evaluated at 650°C on T91 and 316H substrates and showed some benefit for up to 2000 h at 650°C, especially without impurities. However, characterization indicated Al 2 O 3 was not formed and Cr-rich carbides formed in the Cr coatings. With the addition of impurities in the sCO 2 , the coatings were less protective at 650°C. Subsequent exposures at 600°C in sCO 2 showed similar behavior. Postexposure evaluations included measuring the bulk C content and room temperature tensile properties. Finally, improvements were indicated but the tensile results were complicated by the high temperature pack coating process affecting the substrate properties.

36 MATERIALS SCIENCE↗

Unveiling the support effect in Pt-based catalysts for the selective catalytic oxidation of NH 3 under realistic diesel engine conditions

Pt catalysts have been widely used for the selective catalytic oxidation of NH 3 (NH 3 -SCO) in practical applications due to their high activity at low temperatures. However, more stringent regulations require further enhancement of low-temperature NH 3 -SCO activity. In this study, we investigated the influence of different supports, including aluminum oxide (Al 2 O 3 ), silica (SiO 2 ), and chabazite (CHA), on the NH 3 -SCO performance of Pt catalysts. Furthermore, our findings demonstrate that the Pt/CHA catalyst exhibited superior NH 3 -SCO performance under realistic diesel engine conditions, characterized by high space velocity and the presence of water vapor. Notably, the Pt/CHA catalyst achieved a significantly lower T 50 (temperature at which 50% NH 3 conversion is achieved) of 218 °C under conditions with both CO 2 and H 2 O, with a 56 °C reduction compared to the state-of-the-art Pt/Al 2 O 3 catalyst. The exceptional NH 3 -SCO performance is attributed to the high abundance of metallic Pt 0 species and the presence of rich and stable acid sites that facilitate NH 3 adsorption and activation. Furthermore, these results highlight CHA as a promising support for the Pt catalyst in NH 3 -SCO applications for diesel engine emission control.

36 MATERIALS SCIENCE↗

Effect of High Temperature CO 2 on Haynes 230 Alloy (Updated Jan 2021)

The supercritical carbon dioxide (sCO 2 ) Brayton cycle is a promising candidate for future nuclear reactors due to its ability to improve power cycle energy conversion efficiency. The sCO 2 Brayton cycle can operate with an efficiency of 45-50% at operating temperatures of 550-700 C. One of the greatest hurdles currently faced by sCO 2 Brayton cycles is the corrosivity of sCO 2 and the lack of long-term alloy corrosion and mechanical performance data, as these will be key to enhancing the longevity of the system, and thus the levelized cost of electricity. Past studies have shown that sCO 2 corrosion occurs through the formation of metal carbonates, oxide layers, and carburization, and alloys with Cr, Mo and Ni generally exhibit less corrosion. While stainless steels may offer sufficient corrosion resistance at the lower range of temperatures seen by the sCO 2 Brayton cycles, more expensive nickel-based alloys are typically needed for the higher temperature regions. This study investigates the effects of corrosion on the Haynes 230 alloy, with a preliminary view on changes in the mechanical properties. High temperature CO 2 is used for this study as the corrosion products are similar to that of supercritical CO 2 , allowing for an estimation of the susceptibility towards corrosion without the need for high pressure experimentation.

36 MATERIALS SCIENCE↗

Milestone Report: Effect of High Temperature CO 2 on Haynes 230 Alloy

The supercritical carbon dioxide (sCO 2 ) Brayton cycle is a promising candidate for future nuclear reactors due to its ability to improve power cycle energy conversion efficiency. The sCO 2 Brayton cycle can operate with an efficiency of 45-50% at operating temperatures of 550-700 C. One of the greatest hurdles currently faced by sCO 2 Brayton cycles is the extreme corrosivity of sCO 2 . This affects the longevity of the power cycle and thus the levelized cost of electricity. Past studies have shown that sCO 2 corrosion occurs through the formation of metal carbonates, oxide layers, and carburization, and alloys with Cr, Mo and Ni generally exhibit less corrosion. While stainless steels may offer sufficient corrosion resistance at the lower range of temperatures seen by the sCO 2 Brayton cycles, more expensive alloys such as Inconel and Haynes are typically needed for the higher temperature regions. This study investigates the effects of corrosion on the Haynes 230 alloy, focusing on changes in the mechanical properties.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗