Engineering PapersSearch

SEARCH · Engineering Papers

Results for “STORAGE TANK”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

FY25 Organic Evaporation Testing in Support of Hanford Sample-and-Send

The Hanford Waste Treatment and Immobilization Plant (WTP) is being built to treat and immobilize the approximately 56 million gallons of radioactive mixed waste stored in 156 underground storage tanks. The baseline method for immobilization of Low-Activity Waste (LAW) is vitrification, but additional immobilization capacity is needed to supplement the initial LAW melters. Additionally, efforts are being undertaken to accelerate the disposition of Pre-Treated Waste (PTW) in Hanford’s West Area. An alternative cementitious waste form is being investigated as an alternative immobilization method. However, one impediment to a cementitious waste form is the presence of Land Disposal Restricted (LDR) organic chemicals in tank waste, which are regulated on a concentration-based standard in the final waste form. Hence, if the quantity of organics in PTW and LAW is high enough, treatment may be needed to destroy or remove said organics to make a waste form compatible with disposal in a mixed low level waste landfill. This work evaluates evaporation as a potential avenue for treatment of LDR organics to eliminate the impediment and permit possible use of a cementitious waste form.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W

Affinity of LDR Organics to Cementitious Materials and Activated Carbon

The Hanford site stores approximately 56 million gallons of radioactive and hazardous waste in underground storage tanks. The current low-activity waste (LAW) vitrification facility does not have the capacity to immobilize all of the LAW. Therefore, cementitious waste forms are being evaluated as a cost-effective supplemental waste treatment, focusing on the solidification/immobilization of Land Disposal Restricted (LDR) organics, which is currently not recognized by the Environmental Protection Agency (EPA) as a standard treatment method (40 CFR 268.42). Previous efforts by the EPA and waste management agencies have highlighted the potential for cementitious materials to retain certain organic species through physical (encapsulation) and chemical (sorption) interactions.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W

Improved Fundamental Understanding of Aluminum Chemistry and Interactions of Aluminate Anion with Co-Anions: ORNL Project Progress Report

The U.S. Department of Energy (DOE)’s Hanford Site in Washington State houses 177 underground storage tanks containing millions of gallons of nuclear and chemical waste with high aluminum content. Aluminum (Al) salt reactions with strong bases produce aluminum hydroxides, like boehmite (γ-AlOOH), which are main components of insoluble nuclear waste sludge. Understanding the morphology, crystallinity, and dissolution behavior of boehmite under waste tank conditions is necessary for improving waste management and mitigation strategies. The ORNL team uses in situ multimodal analysis strategy to study Al chemistry of simulated tank waste using microfluidic reactors and advanced chemical imaging and mass spectrometry (MS) techniques. Because the SALVI device is vacuum compatible and transferrable among different platforms, we can use it in scanning electron microscopy (SEM), vacuum ultraviolet single photon mass spectrometry (VUV SPI-MS), and time-of-flight secondary ion mass spectrometry (ToF-SIMS) to study the chemical speciation and colloid stability in liquids in this project. Additionally, ex situ transmission electron microscopy (TEM) and x-ray diffraction (XRD) spectroscopy can be used to verify particle phase to further the understanding of the Al-bearing phases. This report gives a summary of the technical progress of the ORNL tasks. A plan for year 2 performance is recommended in the summary.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W

Heavy-Duty Hydrogen Station Equipment Performance Device (HD HyStEP) Specifications and Design Considerations

The original Hydrogen Station Equipment Performance (HyStEP) device was commissioned in 2015 and was critical for the rapid validation of light-duty (LD) hydrogen fueling stations. As applications for hydrogen as a heavy-duty (HD) transportation fuel continue to grow, new heavy-duty stations are being developed to fuel these vehicles that require larger onboard storage tank systems to meet HD transportation demands and drive cycles. The differences in size and geometry from LD vehicles have driven the creation of new hydrogen fueling protocols that will enable safe and economical fueling of HD vehicles. With the new requirements that are set out in HD fueling protocols like SAE J601-5, a new HyStEP-like device is needed to evaluate the capabilities of high-flow hydrogen stations to fuel HD vehicles to the new protocol standard. To create a heavy-duty HyStEP (HD HyStEP) device, an effort has been undertaken to evaluate the requirements that would form the basis for the design of a successful HD HyStEP device. The primary design goal of this HD HyStEP device is its capability of following a test methodology similar to what is outlined in CSA HGV 4.3, which guides the validation of LD fueling dispensers but with adjustments to verify adherence to the HD fueling protocols (SAE J2601-5) for 70 MPa and 35 MPa pressure class vehicles rather than the LD fueling protocols (SAE J2601). The design presented here aims to provide information that enables the creation of an HD HyStEP device that achieves the primary design goal while being informed by the years of experience from the current HyStEP operators.

08 HYDROGEN

FY25 Task 5: Small-Scale Mixing

The U.S. Department of Energy (DOE) Hanford Site has 177 underground storage tanks that contain a complex and diverse mix of chemical and radioactive wastes from past nuclear fuel reprocessing and waste management operations. The strategy of the DOE Hanford Field Office is to retrieve this waste, ~20 vol% of which is in the form of insoluble undissolved solids (UDS) or sludge, and treat it via immobilization at the Hanford Waste Treatment and Immobilization Plant (WTP). The diverse properties and characteristics of Hanford tank waste lead to major challenges related to its transport from the underground tanks to the WTP. These challenges, however, can be addressed by investigating the behavior of tank waste samples and simulant materials and evaluating their behavior against the capabilities of mixing and transport system designs that may be incorporated to retrieve and treat the waste.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W

Demonstration Test Report: Vacuum Thermal Desorption (VTD) Testing to Support West Area Waste Feed Test 2

Approximately 54 million gallons of radioactive and hazardous waste are stored in underground storage tanks at the U.S. Department of Energy’s (DOE’s) Hanford Site in southeastern Washington State. The Hanford Waste Treatment and Immobilization Plant (WTP) is being constructed to immobilize the waste in glass waste forms. The baseline configuration of the WTP includes a Pretreatment Facility to separate the wastes into a small volume of high-level waste (HLW) containing most of the radioactivity and a larger volume of low-activity waste (LAW) containing most of the non-radioactive chemicals. The HLW will be converted to glass in the HLW vitrification facility for ultimate disposal at a federal repository.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W

Next Generation Multi-Use Heavy-Duty High-Flow Direct-Fill Hydrogen Refueling Station with Standardized Design (CRADA Final Report)

The Contractor will build a liquid hydrogen (LH2) fueling station model that is capable of simulating the amount of hydrogen transferred from the liquid storage tank to the vehicle, depending on the station’s design and control scheme. This modeling work will allow the Parties to seek the design and control scheme of an LH2 station that can fill a targeted number of vehicles while meeting a time-average flow rate of 10 kg/min for each fill. While evaluating a high dispensing performance station design and control scheme, the Contractor will analyze the design and control scheme are economically viable.

08 HYDROGEN

Intern Poster Session 08/13: Autonomous Nuclear Robotics: Applications in nuclear waste inspection and hot cell experiments

The nuclear industry is experiencing renewed interest in autonomous robotics, yet most deployed systems remain teleoperated with limited autonomy. This work presents two contributions toward fully autonomous nuclear robotic systems: autonomous waste inspection at the Hanford Site and an autonomous hot cell laboratory framework. Inspections of Hanford's underground waste storage tanks are performed manually at significant cost and personnel exposure. We developed a reinforcement-learning (RL) training pipeline for a custom-built inspection arm. In parallel, we are designing an autonomous laboratory framework for post-irradiation examination in hot cells at the Specimen Preparation Laboratory (SPL) that integrates computer vision, task and motion planning, hardware execution, and operator-in-the-loop control. These systems demonstrate a path toward safer, more efficient nuclear operations by reducing human exposure while maintaining rigorous human oversight at critical decision points.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS

Optimal Operation of Residential High Performance Water Heater for Reduction of Electricity Cost and Peak Demand Through Field Validation

Water heating accounts for about 18% of a typical US home’s energy use. Modern water heaters have enabled control options through APIs, offering customers the opportunity to reduce their energy cost and peak demand by dynamically adjusting settings. A water heater’s capacity to store energy using its storage tank makes it an asset for peak demand reduction and energy cost savings. For this reason, a mixed-integer linear programming model is proposed to minimize the energy cost of a high-performance water heater while also reducing the peak demand of the residential household under a time-of-use utility rate by dynamically changing the water heater’s running mode. Specifically, a multi-objective optimization model is formulated to determine the mode settings of the water heater considering hot water use, time-of-use rate, and peak demand limit of the residential household. The mode settings are associated with different dead bands of water temperature for triggering on/off action of the heat pump and heating element. A 66-gal hybrid electric high performance water heater was used for numerical simulation and practical experiments. The simulation results were well aligned with measurements of practical experiments, validating the soundness of the thermodynamic model. In addition, reductions of energy cost, enabling affordability, and reducing peak demand are demonstrated. The research team also developed a software framework with dashboards to automatically and continuously monitor and manage devices.

Liu, Guodong [ORNL] (ORCID:0000000213498608)

Retrieval of Tank Waste from Storage

This book will provide an overview of the key elements in remediating complex waste sites using the Hanford Site as a case study. In this chapter, the existing infrastructure to store and transfer Hanford wastes, a short history of operations in Hanford Tank Farms, the SST retrieval needs and subsequent DST waste handling operations for retrieval, treatment, and closure are discussed. Waste retrieval operational examples are summarized.

Fountain, Matthew S.

An analysis of Potential Benefits of Adding Diurnal Thermal Storage in Geothermal Heat Pump Systems

Geothermal heat pumps (GHP) are highly efficient for space heating and cooling, utilizing the subsurface of the ground as seasonal energy storage through borehole heat exchangers (i.e., heat stored in summer is used to provide heating in winter, and cold stored in winter is used to provide cooling in summer). On the other hand, diurnal thermal energy storage can actively be charged and discharged for load shifting. Conventional thermal energy storage uses tanks filled with thermal storage media (such as phase change materials) and heat exchangers. It occupies building floor space or land areas outside the building, which may not be available especially in residential buildings. This paper will introduce a novel configuration that can utilize existing GHP system for both diurnal and seasonal thermal storage. This system can actively charge the ground on daily basis by injecting heat or cold in borehole heat exchangers. A simulation model was created for the novel configuration. Computer simulations were conducted using the model for the new GHP system serving a typical single-family house in three U.S. cities representing hot, warm, and cold climates. Based on simulation results, the potential benefits of load shifting and downsize of the expensive ground heat exchangers used by the GHP system were assessed.

Anees, Fady [ORNL]

Conformable, Composite Tank for Liquid Hydrogen Storage in Heavy-duty Ground Transportation

Raytheon Technologies Research Center (RTRC), with its partners, Argonne National Labs and University of Dayton Research Institute proposed to design and manufacture a conformable composite tank prototype to store liquid Hydrogen (LH2) for heavy-duty truck applications. A dual-wall tank concept was proposed where an outer shell covers and protects an inner pressure vessel that stores liquid hydrogen. The inner pressure vessel is liner-less and designed with a conformable concept, derived from prior RTRC ARPA-E program where multiple vessels are coalesced into one, maximizing space utilization and reducing surface area for heat leak. The gap between the dual wall is evacuated of air pressure, and filled with multi-layer insulation to minimize radiative heat transfer. Fiber reinforced composites were proposed for light-weighting and conformable shape manufacture. To minimize LH2 leakage, carbon nanotubes-infused composites were proposed, in addition to use of thin plies. The project was divided into two 18-month budget periods (BP), BP1 and BP2, separated by a Go/No-Go gate review. The high-level goal for BP1 was to demonstrate the feasibility of the overall approach, the tank design, material selection, and manufacturing methodology, build and test a prototype tank; and the goal for BP2 was to design and manufacture a conformal tank per DOE requirements (minimum 20 kg of LH2) and perform a successful test of the tank. The program was terminated about two-thirds of the way through BP1. The outcome of this program would have permitted long-haul trucks and construction vehicles to use liquid Hydrogen, reducing the emission of green-house gases. This technology is applicable to other transportation sectors as well.

08 HYDROGEN

Dehumidification energy storage using a stratified liquid desiccant tank

Liquid desiccants can play an important role in reducing dehumidification energy requirements in the built environment. Because they are in a liquid state, the desiccant can be easily stored and then used to dehumidify buildings during peak energy consumption periods. By maintaining stratification between concentrated and diluted desiccant solutions, a single tank can be used to store liquid desiccant for energy storage purposes. Using a stratified tank instead of separate tanks for dilute and concentrated solutions will reduce storage costs and increase energy storage densities for liquid desiccant systems. This paper describes the experimental validation and one-dimensional modeling of a stratified liquid desiccant tank. The stratified tank prototype developed achieved 80 % of the theoretical energy storage density based on an imposed desiccant concentration change. Here, the stratified tank model was able to reasonably reproduce the experimental results. Using this model, the impact of varying operational conditions on the energy density of the stratified liquid desiccant energy storage was evaluated. Depending on the operating conditions, stratified liquid desiccant energy storage using aqueous LiCl up to 40 wt% can achieve energy storage densities in excess of 330 kWh/m 3 .

25 ENERGY STORAGE

Improved Design Standard for High Temperature Molten Nitrate Salt Tank Design

The Preliminary Design Guide Outline is intended to create a first iteration of the sections of the future Molten Salt Design guide, with an emphasis on gaps in the current industry accepted standard base that already exists. This outline will be a skeleton for the standard moving forward. With this outline, gaps within the current knowledge base are outlined to guide research moving forward.

14 SOLAR ENERGY

SAM Two-Phase Flow Model Development and Applications for Operational Transients in Advanced Reactors

As advanced nuclear technologies continue to develop, the need for the flexible operation and generation of these advanced reactors becomes necessary to maximize economic potential. As large-scale experiments are not always feasible, modeling and simulations of advanced reactors play a crucial role in design optimization and analysis. The SAM (System Analysis Module) code developed at Argonne National Laboratory is a state-of-the-art system-level thermal-hydraulic code aimed at simulating advanced reactor systems. Recent code developments have implemented two-phase flow modeling using the homogeneous equilibrium model, and a new steam generator component has been developed to utilize the two-phase flow implementation. In addition to verification tests, a load-following simulation was performed to model a realistic load-following transient in a proposed integrated system consisting of a conceptual advanced reactor known as the Advanced Burner Test Reactor (ABTR) and thermal energy storage (TES) tanks. The integrated system model uses two large TES tanks designed for sodium and a model helical coil steam generator to simulate the operational load-following transient. The flow rates of the feedwater and secondary loops are regulated to meet a prescribed steam generator load consistent with the electricity demand over a 24-h period. In conclusion, the results found the ABTR system was able to maintain stable reactor conditions and primary- and secondary-side characteristics over the course of the load-following transient.

Advanced Burner Test Reactor (ABTR)

Design Basis Document / Owner’s Technical Specification for Nitrate Salt Systems in CSP Projects (Final Technical Report)

The number of commercial coal, gas, and nuclear projects built over the past 100 years number in the thousands. As such, there is a large database, available to a wide range of commercial engineering contractors, on proven designs. In essence, unsuccessful designs have, through generations of iterations, been identified and then deleted from further consideration. In contrast, the number of commercial parabolic trough projects using nitrate salt for the thermal storage media is perhaps 60. Further, the number of commercial central receiver projects using nitrate salt as the working fluid is on the order of 20, including estimates for China. Given the relative immaturity of salt technology, and commercial pressures to successfully bid new solar projects into a mature electricity market, solar projects often promise more than has been delivered. The Design Basis Document / Owner’s Technical Specification is a first step in the iteration process. The report describes the successful features of commercial projects, outlines a range equipment and system failures in projects that didn’t operate as intended, and provides a draft set of design changes intended to correct the known problems. The product of the study is 3 volumes of technical material; one volume is on parabolic trough technologies; a second is on central receiver technologies, and the third is on potential design changes to parabolic trough and central receiver projects. The 3 volumes, which total some 590 pages, can be found at https://www.solardynllc.com/csp-plant-technologies. One of the principal topics in the report is the use of functional or prescriptive specifications. Functional specifications describe what the equipment needs to do, consistent with the minimum legal requirements of the local jurisdictions. The details of how this is to be accomplished is developed by the engineering contractor. Prescriptive specifications, which are developed by the Owner, prescribe to the engineering contractor how the functional requirements are to be met. This arrangement ensures that the favorable experience from a previous project is repeated. One example is the design code for the hot salt tank in central receiver projects. The closest design basis is API Standard 650 Welded Steel Tanks for Oil Storage. However, the maximum design temperature in API 650 is 260 °C. As such, solar projects have typically adopted a hybrid Code approach, in which allowable material stresses are taken from ASME Section II Materials. Further, since the tanks experience daily changes in temperature and in (static) pressure, and since portions of the tank can operate at stresses beyond the elastic range, the low cycle fatigue life of the tank is conducted using the rules of Section VIII Division 2. However, in a recent study by NREL, the principal damage mechanism was identified as creep rather than fatigue. Further, design stresses permitted under Section VIII Division 2, corresponding to a fatigue life of 30 years, result in projected creep lifetimes of only 2 to 5 years. An alternate design approach, prescribed by the Owner, would be based on Code sections intended for high temperature service in the creep regime. A candidate is Section III Division 5. Granted, this is a nuclear code section, and it’s use would not likely be mandated by local jurisdictions. However, the effects of creep have been deemed to be of sufficient importance that one nuclear project developer, and one central receiver project developer, have stipulated in the tank design specification that the equipment be designed to the requirements of Section III Division 5.

14 SOLAR ENERGY

Nuclear Waste Tank Emission Contributions to Particle Size Distribution

Pollutants from anthropogenic activities including industrial processes are ubiquitous to the environment. To understand the impact from industrial aerosol on climate and human health, industrial aerosol needs to be better characterized. Here, in this study, particle number concentrations were used as a proxy for atmospheric pollutants, which include both particles and gases. Particle concentration and size distribution were measured using a scanning mobility particle sizer (SMPS) approximately 4.5 km from primary industrial areas at the Savannah River Site in Aiken, SC. Industrial areas include numerous nuclear waste storage and processing tanks. The SMPS data were divided into two groups depending on the wind direction measured onsite to categorize transport from the industrial area or from elsewhere. Industrial contributions were found to have a higher concentration of particles with sizes less than 200 nm, 859 ± 564 cm -3 , in comparison to non-industrial attributed particles, 733 ± 495 cm -3 on average from March-July 2021. For sizes larger than 200 nm, industrial and non-industrial particles have a similar concentration, 89 ± 59 cm -3 and 99 ± 61 cm -3 , with non-industrial concentrations being slightly larger. To confirm that industrial particles could travel to the sampling location, air dispersion modeling was completed for specific case studies during the sampling period. The atmospheric dispersion modeling results confirmed that particles released at the industrial areas reached the sampling location when the wind direction was favorable for transport from the industrial areas. The greater concentration of smaller-sized particles in industrial emissions has implications for typical particulate measurements (PM2.5), heath impacts, and climatological influences.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W

Design Considerations for Phase Change Material-Incorporated Heat Exchangers in Water Heating

In recent years, the buildings sector has seen major pushes towards decarbonization through innovations that promote deep electrification. 20% of an average household's energy use comes from water heating, and in the US, over half of all households still use gas water heaters. Of those that use electricity for water heating, the majority use resistive elements rather than heat pump water heaters (HPWHs), the latter of which use 60-70% less energy than the former. However, HPWHs tend to have larger dimensions, preventing current 50-80-gallon tanks on the market from fitting into smaller utility closets sized for 30-40 gallons, such as those found in manufactured housing. Additionally, these smaller HPWHs tend to underperform relative to their larger counterparts. One solution that addresses both space and performance concerns is thermal energy storage, and in particular, phase change materials (PCMs). This study outlines the design process used to produce novel PCM heat exchangers for use in small-volume HPWH tanks, including the identification of design constraints and performance targets relevant to real-world applications. To ensure optimal PCM utilization and tank storage capacity, this works seeks to co-maximize surface area and PCM volume; therefore, this research targets triply periodic minimal surface (TPMS) lattices, which boast enhanced heat transfer capabilities compared to traditional heat exchanger geometries. Starting with a suite of TPMS lattices, we demonstrate a systematic approach for narrowing down feasible designs that comply with identified constraints while meeting PCM performance objectives. Our current results indicate that tuning lattice properties can effectively produce geometries that provide enough energy storage to achieve a 50-gallon capacity out of a 40-gallon HPWH, even when placing the PCM heat exchanger inside the tank. Additionally, we demonstrate successful fabrication of lattices with these tuned properties.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI