Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “STATIC STABILITY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

MP-ALOE: an r2SCAN dataset for universal machine learning interatomic potentials

We present MP-ALOE, a dataset of nearly 1 million DFT calculations using the accurate r2SCAN meta-generalized gradient approximation. Covering 89 elements, MP-ALOE was created using active learning and primarily consists of off-equilibrium structures. We benchmark a machine learning interatomic potential trained on MP-ALOE, and evaluate its performance on a series of benchmarks, including predicting the thermochemical properties of equilibrium structures; predicting forces of far-from-equilibrium structures; maintaining physical soundness under static extreme deformations; and molecular dynamic stability under extreme temperatures and pressures. MP-ALOE shows strong performance on all of these benchmarks and is made public for the broader community to utilize.

Kuner, Matthew C↗

Deployment of Dynamic Neural Network Optimization to Minimize Heat Rate During Ramping for Coal Power Plants (Final Technical Report)

Much success was achieved throughout the course of this project. A successful implementation of Dynamic Neural Network Optimization (D-NNO) was coupled with Adaptive Predictive Controls (APC) and a novel hardware installation comprised of an advanced sensor network (ASN) measuring mass-weighted averages of flue gas constituents above the horizontal superheater of a coal-fired utility boiler. From 2019 through 2023 (including an extension due to COVID delays), the team was able to prototype, evaluate, deploy, iterate, and ultimately finalize an advanced closed-loop control D-NNO system which demonstrated the ability to: •improve unit efficiency ~2.0% relative to unoptimized operation (represented as total fuel fired per MWh generated) •improve unit NOx emission rates 10%+ beyond static optimization baselines •improve unit temperature stability as much as 58% and on average 12% •improve operating load stability as much as 35% The culmination of this project has generated an advanced methodology of deploying specially designed recurrent neural networks (long short-term memory, gated recurrent unit, encoder-decoder networks, transformers, etc.), customized trajectory planning and closed-loop optimization modules capable of adapting to live electric grid responses and demands, self-tuning and adaptive expert controls constantly adjusting prediction parameters to real-time unit behavior, and a hardware/software package able to reliably calculate net unit heat rate (NUHR) in real-time using flue gas constituents, machine learning, and known combustion relationships. Through this real-time NUHR value, immediate feedback on system adjustments relative to operating efficiency was available, allowing for rapid improvements to system performance. In addition to development and deployment of the advanced D-NNO system, the approach methodology has been readily commercialized through the project platform Griffin Open Systems, LLC, the D-NNO software platform host. Similar methodologies to those developed by this project have already been deployed at 5 other units across the United States, with another 6 implementations scheduled, and more expected. Over the course of the project, multiple academic papers were submitted and accepted for publication within esteemed academic journals, and PhD students were trained and graduated, as well as undergraduate students becoming involved and participating to project objectives.

01 COAL, LIGNITE, AND PEAT↗

Unveiling Charge Transport and Degradation Mechanisms of Aqueous Zn|α-MoO 3 Batteries in Conventional Concentration and Water-in-Salt Electrolytes: A Multi-Modal In Situ and Operando Study

Herein charge storage and transport properties are elucidated and cell degradation mechanisms of rechargeable aqueous Zn|alpha-MoO 3 batteries in three electrolyte systems (3 m ZnSO 4 , 3 m ZnCl 2 , and 30 m ZnCl 2 [12.5 m] water-in-salt (WIS)) are distinguished by a combination of in situ X-ray diffraction (XRD), in situ X-ray absorption spectroscopy (XAS), operando optoelectrochemistry, and operando energy dispersive X-ray diffraction (EDXRD). In conventional concentration 3 m electrolytes, in situ XRD and XAS, as well as ex situ scanning transmission electron microscopy data collectively support Zn 2+ as the primary charge carrier. In addition, these systems are susceptible to cathode dissolution, Zn corrosion coupled with the hydrogen evolution reaction, and the resultant formation of basic zinc salt phases. The multi-modal in situ and operando experimental analyses validate facile H+ intercalation and extraction in concentrated 30 m ZnCl 2 WIS electrolyte. Via operando EDXRD, reaction front and charge transport limitation during discharge and charge in the viscous WIS electrolyte are spatially tracked. Here this work provides new insight into the stability and degradation mechanisms of aqueous zinc batteries during static storage and upon dynamic cycling, and highlights the utility of in situ and operando techniques in understanding the superior stability of WIS electrolytes.

25 ENERGY STORAGE↗

Metastable antiphase boundary ordering in CaFe 2 O 4

CaFe 2 O 4 is an $\textit{S}$ = 5/2 antiferromagnet exhibiting two magnetic orders that shows regions of coexistence at some temperatures. Using a Green’s function formalism, we model neutron scattering data of the spin wave excitations in this material, elucidating the microscopic spin Hamiltonian. In doing so, we suggest that the low-temperature A phase order (↑↑↓↓) finds its origins in the freezing of antiphase boundaries created by thermal fluctuations in a parent B phase order (↑↓↑↓). In this work, the low-temperature magnetic order observed in CaFe 2 O 4 is thus the result of a competition between the exchange coupling along $\textit{c}$, which favors the B phase, and the single-ion anisotropy, which stabilizes thermally generated antiphase boundaries, leading to static metastable A phase order at low temperatures.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Quantum computing in power systems

Electric power systems provide the backbone of modern industrial societies. Enabling scalable grid analytics is the keystone to successfully operating large transmission and distribution systems. However, today's power systems are suffering from ever-increasing computational burdens in sustaining the expanding communities and deep integration of renewable energy resources, as well as managing huge volumes of data accordingly. These unprecedented challenges call for transformative analytics to support the resilient operations of power systems. Recently, the explosive growth of quantum computing techniques has ignited new hopes of revolutionizing power system computations. Quantum computing harnesses quantum mechanisms to solve traditionally intractable computational problems, which may lead to ultra-scalable and efficient power grid analytics. This paper reviews the newly emerging application of quantum computing techniques in power systems. We present a comprehensive overview of existing quantum-engineered power analytics from different operation perspectives, including static analysis, transient analysis, stochastic analysis, optimization, stability, and control. We thoroughly discuss the related quantum algorithms, their benefits and limitations, hardware implementations, and recommended practices. We also review the quantum networking techniques to ensure secure communication of power systems in the quantum era. Finally, we discuss challenges and future research directions. This paper will hopefully stimulate increasing attention to the development of quantum-engineered smart grids.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A novel large-scale EV charging scheduling algorithm considering V2G and reactive power management based on ADMM

Electric vehicle aggregators (EVAs) that utilize vehicle-to-grid (V2G) technologies can function as both controllable loads and virtual power plants, providing key energy management services to the distribution system operator (DSO). EVAs can also balance the grid’s reactive power as a virtual static VAR compensator (SVC) and provide voltage stability by utilizing advanced electric vehicle (EV) chargers that are capable of four-quadrant operations to provide reactive power management. Finally, managed charging can benefit EVAs themselves by minimizing power factor penalties in their electricity bills. In this paper, we propose a novel EV charging scheduling algorithm based on a hierarchical distributed optimization framework that minimizes peak load and provides reactive power compensation for the DSO by collaboration with EVAs that manage both the active and the reactive charging and discharging power of participating EVs. Utilizing the alternative direction method of multipliers (ADMM), the proposed distributed optimization approach scales well with increased EV charging infrastructure by balancing active and reactive power while decreasing computational burden. In our proposed hierarchical approach, each EVA schedules the active and reactive EV charging and discharging power for 1) reactive power compensation in order to minimize power factor penalty and electricity cost accrued by the EVA, 2) satisfaction of each EV’s energy demand at minimal charging cost, and 3) peak shaving and load management for the DSO. When compared with an uncoordinated charging model, the efficacy of this proposed model is successfully demonstrated through a 300% decreased peak EV load for the DSO, 28% lower electricity costs for EV users, and 98.55% smaller power factor penalty, along with 17.58% lower overall electricity costs, for EVAs. The performance of our approach is validated in a case study with 50 EVs at multiple EVAs in an IEEE 13-bus test case and compared the results with uncoordinated EV charging.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Adaptive Protection and Validated Models to Enable Deployment of High Penetrations of Solar PV (PV-MOD)

The availability and validation of various PV models in commercial tools differ, with some models not yet thoroughly validated for advanced inverter functionalities and reliable performance under weak system conditions. Many existing models do not fully incorporate new inverter control functions, which can affect system stability. The increasing deployment of solar PV and other inverter-based resources (IBRs), including distributed energy resources (DERs), is influencing the reliable operation of protection schemes in distribution systems and microgrids. Emerging adaptive protection schemes (APS) offer new opportunities for protecting these systems during varying configurations and DER operating conditions, though their demonstration and validation remain limited. Adaptive protection schemes face similar challenges, as they are typically designed for specific configurations. There is a growing need for tools and methodologies to streamline the deployment of adaptive protection for safe and reliable DER integration. The project main objective was to develop and validate high-fidelity generic models of solar PV facilities for stability, protection, EMT, and QSTS analyses. This objective was achieved, and these models can now be integrated into commercial software tools, enabling utilities, vendors, and developers to study high-penetration PV systems more confidently. The project also demonstrated advanced applications of these models, including the design and deployment of adaptive protection schemes in high-penetration field applications and microgrids, supporting grid safety and reliability. Several milestones were reached by the end of the project. A sophisticated inverter test plan was developed, and inverters representative of the North American marketplace were selected. EPRI and NREL tested various inverters, conforming to IEEE standards. Improvements were made to existing generic models of IBR units, IBR plants, and aggregated feeders for various analyses. The first generic electromagnetic transient (EMT) model for a solar PV plant was developed, conforming to IEEE Std 2800™-2022 and validated against laboratory measurements of a 2.2 MVA large-scale battery energy storage system (BESS) inverter. That model was then used to produce reference responses illustrating examples of validated and verified IBR plant models that pass or fail tests for technical minimum capability and performance as specified in the IEEE standard. The developed, tested, and validated generic models can be used for transmission planning, stability assessments, expansion planning, and evaluating potential future IBR interconnection requirements. They can also support interconnection screens and conformity assessments of IBR plants, including solar PV. The project significantly contributed to the ongoing standardization and model-based representation and verification of IBR responses. The project further addressed challenges of common distribution protection schemes with increasing deployment of DER by developing, validating, and demonstrating adaptive protection schemes (APS) that can improve the reliable and safe integration of DER into distribution systems. New APS were designed using improved DER models for three common distribution systems: a radial feeder, a meshed network, and a microgrid. Modeling and hardware-in-the-loop (HIL) testing of the APS were conducted, successfully showing their effectiveness and selectivity. Proof-of-concept field demonstration was achieved for two APS, i.e., one on a radial feeder and another one in a microgrid. Field demonstration could not be achieved for the APS on a meshed network, primarily due apprehension of one utility partner and also due to limited access to the protective algorithms in the network protectors. Guidelines developed from the lessons learned in the project lay out the general process followed in the design, installation, and commissioning of APS for various distribution systems. Distribution utility partners’ apprehension about field demonstration of the new APS were addressed—with varying success—by taking a stepped risk-management approach of modeling of a wide range of sensitivities first, performing in-depth proof-of-concept testing in the laboratory including HIL next, and finally deliberately implementing and commissioning the actual protection equipment and algorithms into parts of—or in parallel operation to—the three real distribution systems. Future work should include pilot projects that further show the acceptable performance of the developed APS before these schemes be rolled out more widely. Inclusion of both utility and original equipment manufacturers (OEMs) in future projects could increase chances of successful field demonstration. Despite challenges in achieving the field demonstration goal of the project for all three APS, the research significantly contributed to the innovation of adaptive protection solutions for scalable and reliable DER integration into distribution systems. This project significantly enhances the understanding of the impact of using appropriate inverter models on distribution and transmission (T&D) systems. By addressing the limitations of existing generic models, the project introduces high-fidelity models for stability, protection, electromagnetic transient (EMT), and quasi-static time series (QSTS) analyses. These models, integrated into commercial software tools, enable utilities, vendors, and developers to confidently study high-penetration PV systems. The project also demonstrates advanced applications, including adaptive protection schemes (APS) for distribution systems and microgrids, ensuring grid safety and reliability. The technical effectiveness and economic feasibility of the methods are evident through the development and validation of sophisticated inverter test plans and the selection of representative inverters. Testing by EPRI and NREL on retail, commercial, and utility-scale inverters, conforming to IEEE standards, underscores the robustness of the models. Improvements to existing generic models for various analyses further enhance their validity and applicability. The project also identifies gaps in common distribution protection schemes and designed new APS using improved DER models, demonstrating their effectiveness through modeling and hardware-in-the-loop (HIL) testing. The project’s benefits to the public are manifold. By advancing the standardization and model-based representation of IBR response, it supports transmission planning, stability assessments, and future IBR interconnection requirements. The generic models can facilitate better communication between transmission planners and developers, supporting expected IBR plant capability and performance. Additionally, the development of APS for radial feeders, meshed networks, and microgrids supports the integration of distributed energy resources (DERs) into distribution systems, enhancing grid reliability and safety. The project’s emphasis on thorough testing and simplicity in design ensures practical and scalable solutions for DER integration.

14 SOLAR ENERGY↗

An Ultrastable Aqueous Iodine-Hydrogen Gas Battery

Rechargeable hydrogen gas batteries are highly desirable for large-scale energy storage because of their long life cycle, high round trip efficiency, fast reaction kinetics, and hydrogen gas profusion. Coupling advanced cathode chemistries with hydrogen gas anode is an emerging and exciting area of research. Here, a novel high-performance aqueous iodine-hydrogen gas (I 2 -H 2 ) battery using iodine as cathode and hydrogen gas as the electrocatalytic anode in environmentally benign aqueous electrolytes is reported. The working chemistry of the battery involves I 2 /I - solid-liquid reactions occurring over the cathode along with H 2 /H 2 O gas-liquid reactions at the anode, achieving a high rate performance of 100 C and long-lasting stability of over 60 000 cycles. Additionally, the static aqueous I 2 -H 2 battery displays a volumetric capacity of 15.5 Ah L -1 along with good self-healing capability towards cell overcharge. The current battery design exhibits robust electrochemical performance irrespective of acidic, neutral, and alkaline electrolyte systems. This study paves the way towards the industrialization of economically effective, high-power density, and long-term I 2 -H 2 batteries for large-scale energy storage applications.

08 HYDROGEN↗

Unraveling the Crystallization Kinetics of 2D Perovskites with Sandwich-Type Structure for High-Performance Photovoltaics

2D perovskite solar cells with high stability and high efficiency have attracted significant attention. A systematical static and dynamic structure investigation is carried out to show the details of 2D morphology evolution. A dual additive approach is used, where the synergy between an alkali metal cation and a polar solvent leads to high-quality 2D perovskite films with sandwich-type structures and vertical phase segregation. Such novel structure can induce high-quality 2D slab growth and reduce internal and surface defects, resulting in a high device efficiency of 16.48% with enhanced continuous illumination stability and improved moisture (55-60%) and thermal (85°C) tolerances. Transient absorption spectra reveal the carrier migration from low n to high n species with different kinetics. An [PbI 6 ] 4- octagon coalescence transformation mechanism coupled with metal and organic cations wrapped is proposed. By solvent vapor annealing, a recrystallization and reorientation of the 2D perovskite slabs occurs to form an ideal structure with improved device performance and stability.

36 MATERIALS SCIENCE↗

Compression rate effects on the Bi-III stability field in dynamic diamond anvil cell XFEL studies of bismuth

This study aims to resolve conflicting observations of bismuth’s high-pressure phase transitions across static, intermediate, and shock compression regimes. We probed its high-pressure structural sequence using the dynamic diamond anvil cell with and time-resolved X-ray diffraction with microsecond resolution at an X-ray free-electron laser. At room temperature and pressures up to 20 gigapascals, bismuth evolves through the same structural sequence previously identified under static compression. However, the transformation behavior differs in important ways under dynamic loading. In particular, the transition from the incommensurate intermediate-pressure phase to the high symmetry high pressure phase begins at pressures about 2 to 4 gigapascals lower than in static experiments, and the onset of this transformation depends on the compression rate. As a result, the stability field of the intermediate-pressure phase is reduced under rapid compression. Our results suggest that at sufficiently fast loading rates the intermediate phase may be bypassed entirely, consistent with previous shock-compression observations.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Corrosion Response of Ni-19Cr-5Fe in Molten NaCl-MgCl 2 Salt

Ni-based alloys are strong candidates for use in high-temperature molten salt reactors due to their superior corrosion resistance and mechanical stability compared to stainless steels. In this study, the static corrosion behavior of a Ni-19Cr-5Fe model alloy was systematically evaluated in a purified molten NaCl-MgCl 2 salt at 700°C for 30, 240, and 500 h. Post-exposure analyses were conducted to assess microstructural evolution, corrosion depth, and elemental depletion profiles. Corrosion rates, quantified by chromium depletion depth, followed an inverse power-law trend with increasing exposure time, indicating diffusion-limited kinetics. This trend is attributed to limitations in mass transport in the static salt and to the progressive local depletion of reactive chromium species. Coupled electron backscatter diffraction and energy dispersive X-ray spectroscopy analysis further revealed that the grain boundary character significantly influences corrosion susceptibility: high-angle grain boundaries exhibited pronounced Cr depletion and pitting, while low-angle and Σ3 boundaries remained comparatively resistant. These results offer valuable insight into the role of microstructure in corrosion processes and reinforce the importance of time-dependent material evaluation in molten salt environments relevant to advanced reactor designs.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Thermally induced cracking on the massive concrete structure of the NSLS II synchrotron and its engineering remediation

Synchrotron accelerator facilities such as the NSLS II require extreme stability, both transient (short-term) and quasi-static (long-term) to achieve the desired resolution performance. Consequently, even μm-level movements, particularly differential movements between locations in the concrete structure supporting the accelerator electron beam lattice (storage ring) or high sensitivity experiments (experimental floor) will lead to serious degradation of its performance. Differential settlement in the overall structure or structural movement exceeding anticipated levels will inevitably degrade the performance and will require intervention. Presented in this paper are the design philosophy of the NSLS II ring structure favoring a monolithic ring, the observed cracking behavior of the young NSLS II concrete following casting and in combination with extreme ambient temperature fluctuation, the results of a non-linear, high-fidelity numerical analysis used to emulate the observed cracking and establish the driving mechanism, the numerical analysis-based identification of the crack-arresting solution and finally the implementation of the remediation solution and the long-term performance of the adopted engineering solution. The multi-stage process revealed that computational methods such as non-linear finite element methods have the potential of providing engineering guidance even when complex structures and in combination with non-linear materials, such as steel reinforcement and concrete are involved.

42 ENGINEERING↗

Dynamic Symmetry Breaking in Chiral Magnetic Systems

The Dzyaloshinskii–Moriya interaction (DMI) in magnetic systems stabilizes spin textures with preferred chirality, applicable to next-generation memory and computing architectures. In perpendicularly magnetized heavy-metal/ferromagnet films, the interfacial DMI originating from structural inversion asymmetry and strong spin-orbit coupling favors chiral Néel-type domain walls (DWs) whose energetics and mobility remain at issue. Thus, a new effect is characterized in which domains expand unidirectionally in response to a combination of out-of-plane and in-plane magnetic fields, with the growth direction controlled by the in-plane field strength. These growth directionalities and symmetries with applied fields cannot be understood from static treatments alone. The authors theoretically demonstrate that perpendicular field torques stabilize steady-state magnetization profiles highly asymmetric in elastic energy, resulting in a dynamic symmetry breaking consistent with the experimental findings. This phenomenon sheds light on the mechanisms governing the dynamics of Néel-type DWs and expands the utility of field-driven DW motion to probe and control chiral DWs.

36 MATERIALS SCIENCE↗

Reactive Extrusion of Waste Plastics with Compatibilizer and Lightly Pyrolyzed Crumb Rubber for Asphalt Modification

Modifying asphalt is a potentially high-value application for reusing waste plastics because of the high-volume usage of asphalt in highway construction. However, simply blending hot plastics and asphalt encounters difficulties related to the poor solubility of polymers, which limits the formation of a swollen network with asphalt molecules. The polymer phases also tend to coalesce and separate from asphalt during high-temperature storage in static conditions. The present study developed an innovative process to stabilize waste plastics in asphalt and improve binder storage stability by using lightly pyrolyzed crumb rubber together with a chemical compatibilizer. Both polymers were extruded to produce a thermoplastic elastomer (TPE) for asphalt modification. The mechanical performance and chemical reactions of TPEs were characterized via tension test and Fourier transform infrared spectroscopy. The storage stability and rheological properties of modified binder blends were evaluated through laboratory asphalt stability test and dynamic shear rheometer test. Polymer phases and network structures were characterized through optical microscopy. It was found that the pyrolyzed and reactive extrusion process improved the rubber solubility and polymer interaction, and therefore the storage stability of modified binder blends. The co-existence of rigid plastic and soft rubbery regimes in an entangled network provided a promising pathway to improve the mechanical performance of asphalt binders in both high- and low-temperature domains.

Ma, Yuetan↗

Experimental Investigation of Polymer Induced Fouling of Heater Tubes in the First-Ever Polymer Flood Pilot on Alaska North Slope

Mineral fouling in heat exchangers has been extensively investigated by researchers in recent times. The oil and gas industry has a long history of fouling issues in production systems as a result of produced fluids treatment. Due to decline in production rates in oilfields new technologies are being developed and field tested in pilots. Polymer flooding is one such technology that involves addition of polymers to injection fluids to enhance oil production. A polymer flood pilot has been set up in the Schrader Bluff viscous oil reservoir at Milne Point field on the Alaska North Slope (ANS). The results from the pilot are encouraging, however a major concern of the operator is the influence of polymer on the production system after breakthrough, especially the fouling in heat exchangers. This study investigates the propensity of polymer fouling on the heater tubes as a function of different variables, with the ultimate goal of determining safe and efficient operating conditions. This work applies a multi-experimental approach to study the severity of polymer-induced fouling in both dynamic and static states of produced fluids as well as studying the stability of polymer solutions at different temperatures. A unique experimental setup was designed and developed in-house to simulate the fouling process on the heating tube. The influence of heating tube skin temperature, tube material, and polymer concentration on fouling tendency was investigated. Each test was run five times with the same tube, and in each run, the freshly prepared synthetic brine and polymer solution was heated from 77°F to 122°F to mimic field-operating conditions. The heating time and fouling amount were recorded for each run. Dynamic Scale Loop (DSL) tests were conducted to study fouling due to polymer at different temperatures (165°F to 350°F) in a dynamic state of fluid flow where the fluids mimic the residence time of fluids in the heat exchanger on the field pilot. Cloud point measurement has also been conducted to find the critical temperature at which the polymer in solution becomes unstable and precipitates out. The morphology and composition of the deposit samples were analyzed by environmental scanning electron microscopy (ESEM) and X-ray diffraction (XRD), respectively. It was found that the presence of polymer in produced fluids would aggravate the fouling issues on both carbon steel and stainless-steel surfaces at all tested skin temperatures. Only higher skin temperatures of 250°F and 350°F could cause polymer-induced fouling issues on the copper tube surface, and the fouling tendency increased with polymer concentration. At the lower skin temperatures of 165°F, no polymer-induced fouling was identified on the copper tube. A critical temperature that is related to the cloud point of the polymer solution was believed to exist, below which polymer-induced fouling would not occur, and only mineral scale was deposited but above which the polymer would aggravate the fouling issue. The cloud point of the tested polymer solution was determined to be between 220°F and 230°F. In the DSL tests it was found that at higher skin temperatures of 250°F and 350°F tube blocking was observed in the DSL tests whereas the tests at 165°F and 200°F did not show any tube blocking in the same time period. These experiments also manifested the influence of cloud point of the solution as deposit rate increased significantly in both carbon steel and stainless-steel tubes when the skin temperature was higher than the solution cloud point. The results of this study have provided guidance to the operator for the field-operations.

Dhaliwal, Anshul↗

Borehole breakout modeling in arkose and granite rocks

The existence of a deep borehole in the Earth’s crust disturbs the local stresses and creates a stress concentration that may result in breakout and damage to the borehole. Maintaining wellbore integrity mitigates environmental impacts such as groundwater contamination, gas leakage to the atmosphere, and fluid spills and seepage at the surface. In this paper, the stability of deep boreholes (5 km) is examined by laboratory experiments and numerical models in the context of nuclear waste disposal in Israel. Two rock types in southern Israel are considered: the crystalline basement (granite) and the Zenifim Formation (arkose). A series of room-temperature triaxial rock deformation experiments were conducted at different confining pressures. This mechanical characterization was then used to parameterize the elastic properties and damage behavior of the rocks. This facilitated modeling the stability of the deep boreholes by two different formulations of damage rheology: a dynamic-oriented formulation used to model deformation immediately after the creation of the open hole and a quasi-static formulation used to model longer stress corrosion regime. The calibrated modeling results indicate greater stability with Zenifim arkose than the crystalline granite for deep borehole conditions despite the granite having a greater triaxial compressive strength. Dissipation associated with dilation and porous compaction in the arkose during deformation plays a significant stabilizing role in the borehole compared to crystalline rocks. These results suggest that common strength-based borehole stability assessment may lead to inaccurate predictions. Three-dimensional modeling of bottom-hole stress conditions and the effects of transient borehole geometry show conventional two-dimensional analysis may not be conservative when predicting borehole damage.

58 GEOSCIENCES↗

Thermal stability of 3D interface Cu/Nb nanolaminates

Nanocrystalline alloys are promising structural materials yet lack thermal stability in many cases. Recent work shows that interface structure has an outsize effect on the thermal behavior of nanostructured alloys. Here, this work focuses on the role of controlled heterophase interface structure in the thermal evolution of model Cu/Nb nanolaminates. We introduce 3D interfaces containing nanoscale heterogeneities in all spatial dimensions between Cu and Nb, forming 3D Cu/Nb. TEM, nanoindentation, and DSC are used in tandem to establish thermal stability and to identify shifts in microstructure as a function of static annealing temperature. 3D interfaces are shown to survive annealing to 300 °C for 1 hr., while 3D Cu/Nb microstructure evolves to form low-density and voided regions correlating to the onset of layer pinch-off between 500 and 600 °C annealing temperatures. A diffusivity- and vacancy energetics-based mechanism is developed to explain void formation driven by 3D interface degradation at elevated temperature.

3D interfaces↗

Enhanced Stability and Sensitivity for CA-125 Detection Under Microfluidic Shear Flow Using Polyethylene Glycol-Coated Biosensor

The microfluidic-based point-of-care (POC) diagnostic tool has garnered significant interest in recent years, offering rapid and cost-effective disease detection. There is a growing trend toward integrating microfluidic platforms with biosensors, aligning lab-on-a-chip technologies with POC diagnostic devices. Despite numerous efforts to incorporate biosensors into microfluidic systems, researchers have performed very limited investigations on the stability of biomarker detection when biosensors operate under microfluidic shear flow conditions. Gold nanoparticles (AuNPs) are a widely employed material in capacitive biosensors for antibody immobilization and sensitivity enhancement. However, AuNPs have limitations in providing stable detection of biomarkers within microfluidic shear flow due to their agglomeration nature. This study addresses these limitations by employing 2 kDa polyethylene glycol (PEG) as an intermediate biofunctional layer to immobilize CA-125 antibodies on gold-interdigitated electrodes for the stable and accurate detection of CA-125 antigens. The stabilities and sensitivities of AuNPs and PEG-coated biosensors are evaluated under both static drop and microfluidic shear flow conditions for CA-125 antigen detection. The experimental results demonstrate a capacitive signal response (5660 pF at 10 kHz) 2.2 times higher using the PEG-coated biosensor than the signal (2551 pF at 10 kHz) measured by the AuNP-coated biosensor in the detection of CA-125 antigen–antibody conjugation under static drop conditions, indicating the higher sensitivity of the PEG-coated biosensor. Additionally, the PEG-coated biosensor exhibits better consistency for the CA-125 antigen detection between static drop and microfluidic shear flow conditions (Cp decrease in percentage (ΔCp%↓) = 2.9% at 10 kHz) compared to the electrical signals measured using the AuNP-coated biosensor (ΔCp%↓ = 32.4% at 10 kHz), which suggests that the PEG-coated biosensor demonstrates higher stability for CA-125 antigen detection under microfluidic shear flow conditions. With these significant improvements brought by the PEG-coated biosensor, especially under microfluidic conditions, a substantial hurdle in developing electrical biosensors for POC diagnostic applications has been overcome, expediting further advancements in the field.

36 MATERIALS SCIENCE↗