Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SQUIDs”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Vortex dynamics induced by scanning SQUID susceptometry

In this work, we measured the local magnetic response of a niobium thin film by applying a millitesla-scale AC magnetic field using a micron-scale field coil and detecting the response with a micron-scale pickup loop in a scanning superconducting quantum interference device (SQUID) susceptometry measurement. Near the film's critical temperature, we observed a steplike nonlinear and dissipative magnetic response due to the dynamics of a small number of vortex-antivortex pairs induced in the film by the local applied AC field. We modeled the dynamics of the measurement using a combined two-dimensional London-Maxwell and time-dependent Ginzburg-Landau approach, allowing us to construct a detailed real-space picture of the vortex motion causing the observed dissipative response. This work pushes scanning SQUID susceptometry of two-dimensional superconductors beyond the regime of linear response and lays the foundation for microscopic studies of vortex dynamics and pinning in superconducting devices and more exotic materials systems.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Improved microwave SQUID multiplexer readout using a kinetic-inductance traveling-wave parametric amplifier

We report on the use of a kinetic-inductance traveling-wave parametric amplifier (KITWPA) as the first amplifier in the readout chain of a microwave superconducting quantum interference device (SQUID) multiplexer (μmux). This μmux is designed to multiplex signals from arrays of low temperature detectors, such as superconducting transition-edge sensor microcalorimeters. When modulated with a periodic flux-ramp to linearize the SQUID response, the flux noise improves, on average, from 1.6 μ $\Phi$ 0 /$\sqrt{Hz}$ with the KITWPA off to 0.77 μ $\Phi$ 0 /$\sqrt{Hz}$ with the KITWPA on. When statically biasing the μmux to the maximally flux-sensitive point, the flux noise drops from 0.45 μ $\Phi$ 0 /$\sqrt{Hz}$ to 0.2 μ $\Phi$ 0 /$\sqrt{Hz}$⁠. We validate this new readout scheme by coupling a transition-edge sensor microcalorimeter to the μmux and detecting background radiation. In conclusion, the combination of μmux and KITWPA provides a variety of new capabilities including improved detector sensitivity and more efficient bandwidth utilization.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Robust and symmetric magnetic field dependency of superconducting diode effect in asymmetric Dirac semimetal SQUIDs

The recent demonstration of the superconducting diode effect (SDE) has generated renewed interest in superconducting electronics, in which devices such as compact superconducting diodes that can perform signal rectification with low-energy operations are needed. In this article, we present our results of robust and symmetric-in-magnetic-field SDE in asymmetric superconducting quantum interference devices (SQUIDs) realized in high-quality Dirac semimetal Cd 3 As 2 thin film grown by the molecular beam epitaxy technique. Consistent with previous work, a zero magnetic field SDE is observed. Furthermore, the difference in switching current is independent of the strength and polarity of an out-plane magnetic field in the range of −10 and 10 mT. We speculate that this robust symmetric-in-field SDE in our Dirac semimetal SQUIDs is due to the formation of helical spin texture, theoretically predicted in Dirac semimetals.

Current-voltage characteristic↗

Quantum Machine Learning with SQUID

In this work we present the Scaled QUantum IDentifier (SQUID), an open-source framework for exploring hybrid Quantum-Classical algorithms for classification problems. The classical infrastructure is based on PyTorch and we provide a standardized design to implement a variety of quantum models with the capability of back-propagation for efficient training. We present the structure of our framework and provide examples of using SQUID in a standard binary classification problem from the popular MNIST dataset. In particular, we highlight the implications for scalability for gradient-based optimization of quantum models on the choice of output for variational quantum models.

97 MATHEMATICS AND COMPUTING↗

Induced electric currents in the Alaska oil pipeline measured by gradient, fluxgate, and SQUID magnetometers

The field gradient method for observing the electric currents in the Alaska pipeline provided consistent values for both the fluxgate and SQUID method of observation. These currents were linearly related to the regularly measured electric and magnetic field changes. Determinations of pipeline current were consistent with values obtained by a direct connection, current shunt technique at a pipeline site about 9.6 km away. The gradient method has the distinct advantage of portability and buried- pipe capability. Field gradients due to the pipe magnetization, geological features, or ionospheric source currents do not seem to contribute a measurable error to such pipe current determination. The SQUID gradiometer is inherently sensitive enough to detect very small currents in a linear conductor at 10 meters, or conversely, to detect small currents of one amphere or more at relatively great distances. It is fairly straightforward to achieve imbalance less than one part in ten thousand, and with extreme care, one part in one million or better.

Campbell, W. H.↗

SQUID readout and ultra-low magnetic fields for Gravity Probe-B (GP-B)

The superconducting readout system to be used for resolving 0.001 arcsec changes in the gyroscope spin direction in the Relativity Gyroscope (GP-B) experiment is described. This system couples the London magnetic moment flux of the spinning gyro to a low noise superconducting quantum interference device (SQUID) detector. Resolution limits and noise performance of the detection system are discussed, and improvements obtained and expected with advanced SQUIDs are presented. Also described is the novel use of superconducting magnetic shielding techniques to obtain a 250 dB attenuation of the earth's magnetic field at the location of the gyroscopes. In this approach, expanded superconducting foil shields are coupled with fixed cylindrical superconducting shields and special geometric considerations to obtain the extremely high attenuation factor required. With these shielding techniques, it appears that the 0.5-Gauss earth field (which appears to the gyroscopes as an ac field at the satellite roll rate) can be reduced to the 10 to the -13th G level required by the experiment. Recent results concerning improvements in the performance of the superconducting foil techniques obtained with the use of a new computer-controlled cooling system are presented.

Lockhart, James M.↗

A YBCO RF-squid variable temperature susceptometer and its applications

The Superconducting QUantum Interference Device (SQUID) susceptibility using a high-temperature radio-frequency (rf) SQUID and a normal metal pick-up coil is employed in testing weak magnetization of the sample. The magnetic moment resolution of the device is 1 x 10(exp -6) emu, and that of the susceptibility is 5 x 10(exp -6) emu/cu cm.

Zhou, Luwei↗

Low Temperature SQUID for NDE Applications

We have developed a low temperature SuperConducting Quantum Interference Device - SQUID measurement system for detection of defects deep under the surface of aluminum structures using eddy current techniques. The system uses a two dimensional planar inducer with two different excitation frequencies to induce a current in the sample. We have developed a data analysis software program that enabled us to distinguish between round defects (holes), straight defects (slots) and slots close to holes simulating cracks starting from rivets in aluminum structures. We were able to detect defects that are 8mm below the surface. We have also measured the change in phase of the detected signal as a function of depth of the defect. This relationship can be used to determine the depth of hidden flaws. Using this analysis software with the high temperature SQUID system at NASA Langley we were able to detect slots close to holes in layered aluminum sample.

Wincheski, Buzz↗

TES Detector Noise Limited Readout Using SQUID Multiplexers

The availability of superconducting Transition Edge Sensors (TES) with large numbers of individual detector pixels requires multiplexers for efficient readout. The use of multiplexers reduces the number of wires needed between the cryogenic electronics and the room temperature electronics and cuts the number of required cryogenic amplifiers. We are using an 8 channel SQUID multiplexer to read out one-dimensional TES arrays which are used for submillimeter astronomical observations. We present results from test measurements which show that the low noise level of the SQUID multiplexers allows accurate measurements of the TES Johnson noise, and that in operation, the readout noise is dominated by the detector noise. Multiplexers for large number of channels require a large bandwidth for the multiplexed readout signal. We discuss the resulting implications for the noise performance of these multiplexers which will be used for the readout of two dimensional TES arrays in next generation instruments.

Staguhn, J. G.↗

Enhancements to a Superconducting Quantum Interference Device (SQUID) Multiplexer Readout and Control System

Far-infrared detector arrays such as the 16x32 superconducting bolometer array for the SAFIRE instrument (flying on the SOFIA airborne observatory) require systems of readout and control electronics to provide translation between a user-driven, digital PC and the cold, analog world of the cryogenic detector. In 2001, the National Institute of Standards and Technology (NIST) developed their Mark III electronics for purposes of control and readout of their 1x32 SQUID Multiplexer chips. We at NASA s Goddard Space Flight Center acquired a Mark 111 system and subsequently designed upgrades to suit our and our collaborators purposes. We developed an arbitrary, programmable multiplexing system that allows the user to cycle through rows in a SQUID array in an infinite number of combinations. We provided hooks in the Mark III system to allow readout of signals from outside the Mark 111 system, such as telescope status information. Finally, we augmented the heart of the system with a new feedback algorithm implementation, flexible diagnostic tools, and informative telemetry.

Forgione, J.↗

Gradiometer Using Middle Loops as Sensing Elements in a Low-Field SQUID MRI System

A new gradiometer scheme uses middle loops as sensing elements in lowfield superconducting quantum interference device (SQUID) magnetic resonance imaging (MRI). This design of a second order gradiometer increases its sensitivity and makes it more uniform, compared to the conventional side loop sensing scheme with a comparable matching SQUID. The space between the two middle loops becomes the imaging volume with the enclosing cryostat built accordingly.

Penanen, Konstantin↗

Practical SQUID Instrument for Nondestructive Testing

We report on the development of a scanning eddy-current imaging system designed to detect deep subsurface flaws in conducting materials. A high transition temperature (high-T c) superconducting quantum interference device (SQUID) magnetometer is employed to provide the required sensitivity at low frequencies, while a combination of small cylindrical high-Tc superconducting and A-metal shields enable the instrument to be scanned in a magnetically noisy environment, rather than the object under test. The shields are arranged to prevent unwanted excitation and ambient noise fields from reaching the SQUID, and to enhance spatial resolution and minimize undesirable edge effects. Thus far, the instrument has successfully detected cracks and pits through 10 layers of aluminum, with a combined thickness of 5 cm at room temperature.

Tralshawala, N.↗

Bandwidth and Aliasing in the Microwave SQUID Multiplexer

The microwave SQUID multiplexer (μmux) has enabled higher bandwidth or higher channel counts across a wide range of experiments in particle physics, astronomy, and spectroscopy. The large multiplexing factor coupled with recent commercial availability of microwave components and warm electronics readout systems make it an attractive candidate for systems requiring large cryogenic detector counts. Since the multiplexer is considered for both bolometric and calorimetric applications across several orders of magnitude of signal frequencies, understanding the bandwidth of the device and its interaction with readout electronics is key to appropriately designing and engineering systems. Here we discuss several important factors contributing to the bandwidth properties of μmux systems, including the intrinsic device bandwidth, interactions with warm electronics readout systems, and aliasing. Further, we present simulations and measurements of μmux devices coupled with SLAC Microresonator RF (SMuRF) tone-tracking electronics and discuss several implications for future experimental design.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Crosstalk Effects in Microwave SQUID Multiplexed TES Bolometer Readout

Transition-edge sensor (TES) bolometers are broadly used for background-limited astrophysical measurements from the far-infrared to mm-waves. Many planned future instruments require increasingly large detector arrays, but their scalability is limited by their cryogenic readout electronics. Microwave SQUID multiplexing offers a highly capable scaling solution through the use of inherently broadband circuitry, enabling readout of hundreds to thousands of channels per microwave line. As with any multiplexing technique, the channelization mechanism gives rise to electrical crosstalk which must be understood and controlled so as to not degrade the instrument sensitivity. Here, in this study, we explore implications relevant for TES bolometer array applications, focusing in particular on upcoming mm-wave observatories such as the Simons Observatory and AliCPT. We model the relative contributions of the various underlying crosstalk mechanisms, evaluate the difference between fixed-tone and tone-tracking readout systems, and discuss ways in which crosstalk nonlinearity will complicate on-sky measurements.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A microwave SQUID multiplexer optimized for bolometric applications

A microwave SQUID (superconducting quantum interference device) has been optimized for reading out large arrays of superconducting transition-edge sensor (TES) bolometers. We present the scalable cryogenic multiplexer chip design that may be used to construct an 1820-channel multiplexer for the 4-8 GHz rf band. The key metrics of yield, sensitivity, and crosstalk are determined through measurements of 455 readout channels, which span 4-5 GHz. The median white-noise level is 45 pA/ $\sqrt{Hz}$, evaluated at 2 Hz, with a 1/f knee ≤ 20 mHz after common-mode subtraction. The white-noise level decreases the sensitivity of a TES bolometer optimized for detection of the cosmic microwave background at 150 GHz by only 3%. The measured crosstalk between any channel pair is ≤ 0.3%.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Structure–function relationships for squid skin-inspired wearable thermoregulatory materials

Wearable thermoregulatory technologies have attracted widespread attention because of their potential for impacting individual physiological comfort and for reducing building energy consumption. Within this context, the study of materials and systems that can merge the advantageous characteristics of both active and passive operating modes has proven particularly attractive. Accordingly, our laboratory has drawn inspiration from the appearance-changing skin of Loliginidae (inshore squids) for the introduction of a unique class of dynamic thermoregulatory composite materials with outstanding figures of merit. Herein, we demonstrate a straightforward approach for experimentally controlling and computationally predicting the adaptive infrared properties of such bioinspired composites, thereby enabling the development and validation of robust structure–function relationships for the composites. Our findings may help unlock the potential of not only the described materials but also comparable systems for applications as varied as thermoregulatory wearables, food packaging, infrared camouflage, soft robotics, and biomedical sensing.

Liu, Panyiming (ORCID:0000000242223670)↗

Constraints on a split superconducting transition under uniaxial strain in Sr 2 RuO 4 from scanning SQUID microscopy

More than two decades after the discovery of superconductivity in Sr 2 RuO 4 , it is still unclear whether the order parameter has a single component or two degenerate components. For any two-component scenario, application of uniaxial strain is expected to lift the degeneracy, generating two distinct phase transitions. The presence of a second (lower-temperature) transition may be observable by probes that are sensitive to changes in the London penetration depth, λ, as a function of temperature, T. Furthermore, we use scanning SQUID microscopy combined with a uniaxial strain device to test for a second transition under strain. We only observe a single transition. Within the temperature range where a second transition has been suggested by μSR measurements, we further place a tight upper bound of less than 1% on the change in the zero temperature superfluid density n s ∝ λ –2 (0) due to a second transition, suggesting that such a transition does not occur. These results constrain theories of the order parameter in Sr 2 RuO 4 .

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Scanning SQUID study of ferromagnetism and superconductivity in infinite-layer nickelates

Infinite-layer nickelates R 1-x Sr x NiO 2 (R = La, Pr, Nd) are a class of superconductors with structural similarities to cuprates. Although long-range antiferromagnetic order has not been observed for these materials, magnetic effects such as antiferromagnetic spin fluctuations and spin-glass behavior have been reported. Different experiments have drawn different conclusions about whether the pairing symmetry is s or d wave. In this paper, we applied a scanning superconducting quantum interference device (SQUID) to probe the magnetic behavior of film samples of three infinite-layer nickelates (La 0.85 Sr 0.15 NiO 2 , Pr 0.8 Sr 0.2 NiO 2 , and Nd 0.775 Sr 0.225 NiO 2 ) grown on SrTiO 3 (STO), each with a nominal thickness of 20 unit cells. In all three films, we observed a ferromagnetic background. We also measured the magnetic susceptibility above the superconducting critical temperature in Pr 0.8 Sr 0.2 NiO 2 and La 0.85 Sr 0.15 NiO 2 and identified a non-Curie-Weiss dynamic susceptibility. Both magnetic features are likely due to NiO x nanoparticles. We investigated superconductivity in Pr 0.8 Sr 0.2 NiO 2 and Nd 0.775 Sr 0.225 NiO 2 , which exhibited inhomogeneous diamagnetic screening. The superfluid density inferred from the diamagnetic susceptibility in relatively homogeneous regions shows T-linear behavior in both samples. Finally, we observed superconducting vortices in Nd 0.775 Sr 0.225 NiO 2 . We determined a Pearl length of 330 µm for Nd 0.775 Sr 0.225 NiO 2 at 300 mK, both from the strength of the diamagnetism and from the size and shape of the vortices. These results highlight the importance of considering NiO x particles when interpreting experimental results for these films.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗