SEARCH · Engineering Papers
Results for “SPEED LIMIT”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Path-independent Speed Limits for Open Quantum Systems
Explore the source record for details and available documents.
Alkali-metal turbine geometry as affected by blade-speed limitations
Alkali metal turbine design limitation imposed by blade velocity
Aircraft design for flight below the sonic boom speed limit
The avoidance of sonic booms places a constraint on aircraft design and can lead to unusual new configurations. From a comparison among several candidate designs, it is shown that an oblique-wing aircraft offers many advantages when structure, stability, flight efficiency, and airport noise are considered jointly.
Aircraft design for flight below the sonic boom speed limit
The avoidance of sonic booms places a constraint on aircraft design and can lead to unusual new configurations. From a comparison among several candidate designs, it is shown that an oblique winged aircraft offers many advantages when structure, stability, flight efficiency, and airport noise are considered jointly.
SEE Test Report for Arizona Microtek AZ88923 High Speed Limiting Post Amplifier
The primary purpose of this testing is to characterize the Texas Instruments AZ88923 post amplifier for susceptibility to single-event latchup (SEL) and other destructive Single-Event Effects (SEE). These data will be used to assess the destructive SEE risk for the OSIRIS-REx Laser Altimeter (OLA). A secondary goal is to assess the susceptibility of the post amplifier to single-event transients (SET) and other nondestructive SEE. In particular, the loss-of-signal feature could give rise to some significant anomalies. However, it is not used on OLA.
Hypervelocity sampling at Enceladus: Is there a speed limit for biosignature detection?
No abstract provided
Breaking the universal speed limit: Emission of radiation by superluminal sources
Abstract Not Provided
Scalar Speed Limits and Cosmology: Acceleration from D-cceleration
Explore the source record for details and available documents.
Global limits on kinetic Alfvenon speed in quasineutral plasmas
Large-amplitude kinetic Alfvenon (exact Alfven soliton) matching condition is investigated in quasineutral electron-ion and electron-positron-ion plasmas immersed in a uniform magnetic field. Using the standard pseudopotential method, the magnetohydrodynamics equations are exactly solved, and a global allowed matching condition for propagation of kinetic solitary waves is derived. It is remarked that, depending on the plasma parameters, the kinetic solitons can be sub-Alfvenic or super-Alfvenic, in general. It is further revealed that, either upper or lower soliton speed-limit is independent of fractional plasma parameters. Furthermore, the soliton propagation angle with respect to that of the uniform magnetic field is found to play a fundamental role in controlling the soliton matching speed-range.
Enriching OpenStreetMap network data for transportation applications: Insights into the impact of urban congestion on accessibility
OpenStreetMap (OSM) data is a valuable open-source resource for various transportation, traffic, and planning applications. However, OSM network data lack operating traffic speed information, which is critical for transport planning and operations. Addressing this shortcoming, this study leverages commercial vendor data (to serve as ground truth) with exogenous, open-source variables characterizing local transport infrastructure, land use, and demographic information to predict average congested traffic speeds on OSM networks. Three machine-learning models were tested and estimated for OSM links with and without speed limit information in the Denver metropolitan region. Among these, XGBoost performed best, with mean absolute errors of 3.27 and 3.62 mph for links with and without speed limits, respectively. The developed models accurately predicted traffic speeds for different hours and days of the week compared to ground truth data. Using these predicted speeds, drive accessibility scores were computed for the Denver region for different time periods using the Mobility Energy Productivity (MEP) metric to understand the impact of congestion on energy-efficient accessibility. Results show that congestion-adjusted drive accessibility can be significantly lower compared to accessibility calculated using free flow speeds. Specifically, weekday evening hours saw a 42 % drop in accessibility due to reduced speeds, particularly around downtown Denver. Across the Denver metro region, approximately half as many opportunities and jobs are accessible in under 20 min by car during the evening peak period relative to free flow conditions. These findings underscore the importance of using congestion-adjusted operating speeds rather than speed limits in accessibility calculations, as reliance on speed limits can substantially overestimate energy-efficient drive accessibility in large, car-centric cities susceptible to significant congestion. In conclusion, the methodology presented here could further enrich OSM network data, making them useful for an even broader range of transportation applications.
Low-speed test limit of V/STOL model located vertically off-center
A vertically off-centered V/STOL model - a 2-ft-diam three-bladed aluminum propeller operating in a rotor mode - is tested in an 8 by 12 ft wind tunnel with and without ground plane along with an associated 3 by 4.5 ft test section insert. The objective was to assess the effect of the vertically off-centered model on the low-speed test limit. The aerodynamic data of the model at a constant negative angle of attack (-3 deg) are recorded at selected tunnel dynamic pressures to provide adequate data points to define the model lift variation with respect to the tip speed ratio. The adverse effect of the rotor low-speed test limit is observed in the form of lift change with respect to the tip speed ratio. A major conclusion is that for rotors tested with a ground plane or in the vicinity of the floor, the ratio of distance between floor and model to rotor radius defines the low-speed test limits.
Dry Cask Shipments of ATR Spent Nuclear Fuel at INL
The High Load Charger (HLC) cask will be replacing the Advanced Test Reactor (ATR) spent fuel transfer cask that has been used at Idaho National Laboratory (INL) to wet-transfer spent ATR fuel elements from ATR to Idaho Nuclear Technology and Engineering Center (INTEC) in order to support future plans at both facilities. INTEC intends to discontinue use of the CPP-666 storage pools in compliance with the Idaho Settlement Agreement and the basins will no longer be available to store spent ATR fuel elements. In order to support the core-internals change out in 2021 for ATR, spent ATR fuel elements must be removed from the canal and shipped to INTEC. INL contractors will use the HLC cask for safe, dry transfer of spent Advanced Test Reactor (ATR) fuel elements between the ATR Complex managed by Battelle Energy Alliance, LLC and the Idaho Nuclear Technology and Engineering Center (INTEC) managed by Fluor Idaho, LLC. The HLC cask (also known as the High Load Charging Cask or High Load Charger) is a lead-shielded, stainless steel transfer container originally designed in 1954 by the Idaho Nuclear Corporation to meet the radiation and contamination controls requirements of the time for shipment of spent nuclear fuel. The cask has been modified over the years and is currently used for wet-to-dry transfers at INTEC. It is approved only for out-of-commerce transfers. The cask will arrive at the ATR where eight spent ATR fuel elements will be loaded into two, newly-designed buckets. Each bucket is a quarter section, right-cylinder shape that has four compartments. The cask will be lifted out of the ATR canal allowing most of the water to drain from the cask. Processing the 12,500 kg cask will be completed in ATR and then transported on a tractor trailer to INTEC where the loaded buckets will be removed from the cask. The loaded buckets will undergo a drying process before placing the four buckets into a canister for long-term storage in the Irradiated Fuel Storage Facility (IFSF) at INTEC. A new transportation plan that was submitted to, and approved by, the U.S. Department of Energy to provide the cask safety basis, which describes the hazard analysis and accident analysis for the cask during transport. Supporting accident analysis include criticality, thermal, dose, and drop analyses. Of particular interest for this cask was the drop analysis from which was derived the speed limit for the transport. The drop analysis addressed drops in air onto an unyielding surface and in water onto an energy-absorbing pad for the cask in the ATR facility. These analyses are typically applied as the bounding drop scenarios during transport; however, this resulted in a safety basis speed limit of 12.9 kph. In order to more accurately represent the in-transit accident scenario, LS-DYNA software was procured and the model was updated to more closely represent the potential drop heights and impact surfaces of asphalt and soil for the cask while in transit. This analysis resulted in a safety basis speed limit of 48 kph. This safety basis speed limit is more practical to implement and control.
Dry Cask Shipments of ATR Spent Nuclear Fuel at INL - 19600
The High Load Charger (HLC) cask will be replacing the Advanced Test Reactor (ATR) spent fuel transfer cask that has been used at Idaho National Laboratory (INL) to wet-transfer spent ATR fuel elements from ATR to Idaho Nuclear Technology and Engineering Center (INTEC) in order to support future plans at both facilities. INTEC intends to discontinue use of the CPP-666 storage pools in compliance with the Idaho Settlement Agreement and the basins will no longer be available to store spent ATR fuel elements. In order to support the core-internals change out in 2021 for ATR, spent ATR fuel elements must be removed from the canal and shipped to INTEC. INL contractors will use the HLC cask for safe, dry transfer of spent Advanced Test Reactor (ATR) fuel elements between the ATR Complex managed by Battelle Energy Alliance, LLC and the Idaho Nuclear Technology and Engineering Center (INTEC) managed by Fluor Idaho, LLC. The HLC cask (also known as the High Load Charging Cask or High Load Charger) is a lead-shielded, stainless steel transfer container originally designed in 1954 by the Idaho Nuclear Corporation to meet the radiation and contamination controls requirements of the time for shipment of spent nuclear fuel. The cask has been modified over the years and is currently used for wet-to-dry transfers at INTEC. It is approved only for out-of-commerce transfers. The cask will arrive at the ATR where eight spent ATR fuel elements will be loaded into two, newly-designed buckets. Each bucket is a quarter section, right-cylinder shape that has four compartments. The cask will be lifted out of the ATR canal allowing most of the water to drain from the cask. Processing the 12,500 kg cask will be completed in ATR and then transported on a tractor trailer to INTEC where the loaded buckets will be removed from the cask. The loaded buckets will undergo a drying process before placing the four buckets into a canister for long-term storage in the Irradiated Fuel Storage Facility (IFSF) at INTEC. A new transportation plan that was submitted to, and approved by, the U.S. Department of Energy to provide the cask safety basis, which describes the hazard analysis and accident analysis for the cask during transport. Supporting accident analysis include criticality, thermal, dose, and drop analyses. Of particular interest for this cask was the drop analysis from which was derived the speed limit for the transport. The drop analysis addressed drops in air onto an unyielding surface and in water onto an energy-absorbing pad for the cask in the ATR facility. These analyses are typically applied as the bounding drop scenarios during transport; however, this resulted in a safety basis speed limit of 12.9 kph. In order to more accurately represent the in-transit accident scenario, LS-DYNA software was procured and the model was updated to more closely represent the potential drop heights and impact surfaces of asphalt and soil for the cask while in transit. This analysis resulted in a safety basis speed limit of 48 kph. This safety basis speed limit is more practical to implement and control. (authors)
Assessing the effects of noise abatement measures on health risks: A case study in Istanbul
In recent decades, noise pollution caused by industrialization and increased motorization has become a major concern around the world because of its adverse effects on human well-being. Therefore, transportation agencies have been implementing noise abatement measures in order to reduce road traffic noise. However, limited attention is given to noise in environmental assessment of road transportation systems. This paper presents a framework for a health impact assessment model for road transportation noise emissions. The model allows noise impacts to be addressed with the health effects of air pollutant and greenhouse gas emissions from road transportation. The health damages assessed in the model include annoyance, sleep disturbance, and cardiovascular disease in terms of acute myocardial infarction. The model was applied in a case study in Istanbul in order to evaluate the change in health risks from the implementation of noise abatement strategies. The noise abatement strategies evaluated include altering pavement surfaces in order to absorb noise and introducing speed limits. It was shown that significant improvements in health risks can be achieved using open graded pavement surfaces and introducing speed limits on highways. - Highlights: • Transportation noise has a significant effect on health. • Noise should be included in the environmental assessment of transportation systems. • Traffic noise abatement measures include noise reducing pavements and speed limits. • Noise abatement measures help reduce the health risks of transportation noise. • Speed limit reduction on uncongested roads is an effective way to reduce health risks.
Limiting critical speed response on the SSME Alternate High Pressure Fuel Turbopump (ATD HPFTP) with bearing deadband
Yammamoto (1954) described the influence of bearing deadband on the critical speed response of a rotor-bearing system. Practical application of these concepts to limit critical speed response of turbopump rotors is described. Nonlinear rotordynamic analyses are used to define the effect of bearing deadband and rotor unbalance on the Space Shuttle Main Engine Alternate High Pressure Fuel Turbopump. Analysis results are used with hot fire test data to verify the presence of a lightly damped critical speed within the operating speed range. With the proper control of rotor unbalance and bearing deadband, the response of this critical speed is reduced to acceptable levels without major design modifications or additional sources of damping.