Ion Mobility Spectrometry (IMS) and Mass Spectrometry

In a media of finite viscosity, the Coulomb force of external electric field moves ions with some terminal speed. This dynamics is controlled by “mobility” - a property of the interaction potential between ions and media molecules. This fact has been used to separate and characterize gas-phase ions in various modes of ion mobility spectrometry (IMS) developed since 1970. Commercial IMS devices were introduced in 1980-s for field detection of volatile traces such as explosives and chemical warfare agents. Coupling to soft-ionization sources, mass spectrometry (MS), and chromatographic methods in 1990-s had allowed IMS to handle complex samples, enabling new applications in biological and environmental analyses, nanoscience, and other areas. Since 2003, the introduction of commercial systems by major instrument vendors started bringing the IMS/MS capability to broad user community. The other major development of last decade has been the differential IMS or “field asymmetric waveform IMS” (FAIMS) that employs asymmetric time-dependent electric field to sort ions not by mobility itself, but by the difference between its values in strong and weak electric fields. Coupling of FAIMS to conventional IMS and stacking of conventional IMS stages have enabled two-dimensional separations that dramatically expand the power of ion mobility methods.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Production of highly-enriched 134Ba for a reference material for isotope dilution mass spectrometry measurements

Isotope dilution mass spectrometry (IDMS) is an analytical technique capable of providing accurate and precise quantitation of trace isotope abundance and assay providing measurement uncertainties below 1 %. To achieve these low uncertainties, the IDMS method ideally utilizes chemically pure “spike” solutions that consist of a single highly enriched isotope that is well-characterized relating to the abundance of companion isotopes and concentration in solution. To address a current demand for accurate 137Cs/137Ba ratio measurements for “age” determination of radioactive 137Cs sources, Idaho National Laboratory (INL) is producing enriched 134Ba isotopes that are tobe used for IDMS spikes to accurately determine 137Ba accumulation from the decay of 137Cs. The final objective of this work it to provide a homogenous set of reference materials that the National Institute of Standards and Technology can certify as standard reference materials used for IDMS. The process that was developed at INL for the separation and isolation of Ba isotopes, chemical purification of the isotopes in solution, and the encapsulation of the materials will be described.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Five Micron High Resolution MALDI Mass Spectrometry Imaging with Simple, Interchangeable, Multi-Resolution Optical System

High-spatial resolution mass spectrometry imaging (MSI) is crucial for the mapping of chemical distributions at the cellular and subcellular level. In this work, we improved our previous laser optical system for matrix-assisted laser desorption ionization (MALDI)-MSI, from ~9 μm practical laser spot size to a practical laser spot size of ~4 μm, thereby allowing for 5 μm resolution imaging without oversampling. This is accomplished through a combination of spatial filtering, beam expansion, and reduction of the final focal length. Most importantly, the new laser optics system allows for simple modification of the spot size solely through the interchanging of the beam expander component. Using 10×, 5×, and no beam expander, we could routinely change between ~4, ~7, and ~45 μm laser spot size, in less than 5 min. We applied this multi-resolution MALDI-MSI system to a single maize root tissue section with three different spatial resolutions of 5, 10, and 50 μm and compared the differences in imaging quality and signal sensitivity. We also demonstrated the difference in depth of focus between the optical systems with 10× and 5× beam expanders. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Towards High-Resolution Tissue Imaging Using Nanospray Desorption Electrospray Ionization Mass Spectrometry Coupled to Shear Force Microscopy

Constant mode ambient mass spectrometry imaging (MSI) of tissue sections with high lateral resolution of better than 10 μm was performed by combining shear force microscopy with nanospray desorption electrospray ionization (nano-DESI). Shear force microscopy enabled precise control of the distance between the sample and nano-DESI probe during MSI experiments and provided information on sample topography. Proof-of-concept experiments were performed using lung and brain tissue sections representing spongy and dense tissues, respectively. Topography images obtained using shear force microscopy were comparable to the results obtained using contact profilometry over the same region of the tissue section. Variations in tissue height were found to be dependent on the tissue type and were in the range of 0–5 μm for lung tissue and 0–3 μm for brain tissue sections. Ion images of phospholipids obtained in this study are in good agreement with literature data. Normalization of nano-DESI MSI images to the signal of the internal standard added to the extraction solvent allowed us to construct high-resolution ion images free of matrix effects. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fourier Transform-Ion Cyclotron Resonance Mass Spectrometry as a Platform for Characterizing Multimeric Membrane Protein Complexes

Membrane protein characterization is consistently hampered by challenges with expression, purification, and solubilization. Among several biophysical techniques employed for their characterization, native-mass spectrometry (MS) has emerged as a powerful tool for the analysis of membrane proteins and complexes. Here, two MS platforms, the FT-ICR and Q-ToF, have been explored to analyze the homotetrameric water channel protein, AquaporinZ (AqpZ), under non-denaturing conditions. This 97 kDa membrane protein complex can be readily liberated from the octylglucoside (OG) detergent micelle under a range of instrument conditions on both MS platforms. Increasing the applied collision energy of the FT-ICR collision cell yielded varying degrees of tetramer (97 kDa) liberation from the OG micelles, as well as dissociation into the trimeric (72 kDa) and monomeric (24 kDa) substituents. Tandem-MS on the Q-ToF yielded higher intensity tetramer signal and, depending on the m/z region selected, the observed monomer signal varied in intensity. Precursor ion selection of an m/z range above the expected protein signal distribution, followed by mild collisional activation, is able to efficiently liberate AqpZ with a high S/N ratio. The tetrameric charge state distribution obtained on both instruments demonstrated superpositioning of multiple proteoforms due to varying degrees of N-terminal formylation. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Secondary ion mass spectrometry: The application in the analysis of atmospheric particulate matter

Currently, considerable attention has been paid to atmospheric particulate matter (PM) investigation due to its importance in human health and global climate change. Surface characterization of PM is important since the chemical heterogeneity between the surface and bulk may vary its impact on the environment and human being. Secondary ion mass spectrometry (SIMS) is a surface technique with high surface sensitivity, capable of high spatial chemical imaging and depth profiling. Recent research shows that SIMS holds great potential in analyzing both surface and bulk chemical information of PM. In this review, we presented the working principal of SIMS in PM characterization, summarized recent applications in PM analysis from different sources, discussed its advantages and limitations, and proposed the future development of this technique with a perspective in environmental sciences.

aerosol↗

Determining aromatic and aliphatic carboxylic acids in biomass-derived oil samples using 2,4-dinitrophenylhydrazine and liquid chromatography-electrospray injection-mass spectrometry/mass spectrometry

Converting biomass to a useful fuel commonly incorporates the pyrolysis of the biomass feed stock. The base liquid fraction usually contains high concentrations of ketones, aldehydes and carboxylic acids, of which each can cause detrimental issues related to the storage and upgrading process. Knowing the carbonyl species and the concentration of each will provide value information to the pyrolysis researchers, specifically as that community branches into more targeted end-products such as jet fuel or biogenic-derived oxygenate-containing fuel products. The analysis of aldehydes, ketones and small alkyl carboxylic acids using 2,4-dinitrophenylhydrazine (DNPH) derivation method has been well documented and the method is commonly used the analytical community. By using liquid chromatograph coupled to tandem mass spectrometry, biomass sample analysis can be complete with identification of most carbonyl species. The issue of identifying isobaric ketone and aldehyde compounds can be resolved by utilizing differences in retention time or characteristic fragment ions of ketones and aldehydes. One issue which could not resolved using published methods was identifying aromatic or large non-aromatic carboxylic acids from their corresponding hydroxyl aldehyde or ketone analogs. By modifying the current method for determining carbonyls in biomass samples, carboxylic and hydroxyl-carbonyl can be determined. A careful adjustment of the pH during the extraction procedure and extended heating time of the DNPH solution allowed for the successful derivation of aromatic carboxylic acids. Like other dinitrophenylhydrazones, carboxylic acid derivatives also produce a unique secondary ion pattern, which was useful to distinguish these species from the non-acid analogs.

bio-oil↗

Combustion chemistry of the propanol isomers - investigated by electron ionization and VUV-photoionization molecular-beam mass spectrometry

The combustion of 1-propanol and 2-propanol was studied in low-pressure, premixed flat flames using two independent molecular-beam mass spectrometry (MBMS) techniques. For each alcohol, a set of three flames with different stoichiometries was measured, providing an extensive data base with in total twelve conditions. Profiles of stable and intermediate species, including several radicals, were measured as a function of height above the burner. The major-species mole fraction profiles in the 1-propanol flames and the 2-propanol flames of corresponding stoichiometry are nearly identical, and only small quantitative variations in the intermediate species pool could be detected. Differences between flames of the isomeric fuels are most pronounced for oxygenated intermediates that can be formed directly from the fuel during the oxidation process. The analysis of the species pool in the set of flames was greatly facilitated by using two complementary MBMS techniques. One apparatus employs electron ionization (EI) and the other uses VUV light for single-photon ionization (VUV-PI). The photoionization technique offers a much higher energy resolution than electron ionization and as a consequence, near-threshold photoionization-efficiency measurements provide selective detection of individual isomers. The EI data are recorded with a higher mass resolution than the PI spectra, thus enabling separation of mass overlaps of species with similar ionization energies that may be difficult to distinguish in the photoionization data. The quantitative agreement between the EI- and PI-datasets is good. In addition, the information in the EI- and PI-datasets is complementary, aiding in the assessment of the quality of individual burner profiles. The species profiles are supplemented by flame temperature profiles. The considerable experimental efforts to unambiguously assign intermediate species and to provide reliable quantitative concentrations are thought to be valuable for improving the mechanisms for higher alcohol combustion. (author)

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

An algorithm to correct saturated mass spectrometry ion abundances for enhanced quantitation and mass accuracy in omic studies

The mass accuracy and peak intensity of ions detected by mass spectrometry (MS) measurements are essential to facilitate compound identification and quantitation. However, high concentration species can easily cause problems if their ion intensities reach beyond the limits of the detection system, leading to distorted and non-ideal detector response (e.g. saturation), and largely precluding the calculation of accurate m/z and intensity values. Here we present an open source computational method to correct peaks above a defined intensity (saturated) threshold determined by the MS instrumentation such as the analog-to-digital converters or time-to-digital converters used in conjunction with time-of-flight MS. In this method, the isotopic envelope for each observed ion above the saturation threshold is compared to its expected theoretical isotopic distribution. The most intense isotopic peak for which saturation does not occur is then utilized to re-calculate the precursor m/z and correct the intensity, resulting in both higher mass accuracy and greater dynamic range. The benefits of this approach were evaluated with proteomic and lipidomic datasets of varying complexities. After correcting the high concentration species, reduced mass errors and enhanced dynamic range were observed for both simple and complex omic samples. Specifically, the mass error dropped by more than 50% in most cases with highly saturated species and dynamic range increased by 1-2 orders of magnitude for peptides in a blood serum sample.

Environmental Molecular Sciences Laboratory↗

Toxicokinetics of benzo[a]pyrene in humans: Extensive metabolism as determined by UPLC-accelerator mass spectrometry following oral micro-dosing

Benzo[a]pyrene (BaP), produces tumors of skin, lung, liver, kidney and stomach in animals, enhances lung cancer in epidemiological studies and is a known human carcinogen. The EPA cancer slope risk factor for oral BaP exposure is 1 per mg/kg-day. The remarkable sensitivity (attomole 14C; precision 0.5-2% in biological samples) of accelerator mass spectrometry (AMS) makes possible [14C]-BaP dosing of humans with de minimus risk. A micro-dose of 46 ng (5 nCi), was given in 3 separate cycles to 5 human volunteers with a minimum 2 weeks between dosing. Blood was collected over 72 hours and BaP and BaP metabolites ([14C]-BaPeq) measured using AMS. [14C]-BaPeq appeared in plasma with an average Tmax of 75 minutes and Cmax 116-326 fM (29-82 fg/mL). Non-compartmental half-lives in plasma ranged from 30.7-114.2 hours and area under the curve values (AUC0-72 hr) 649-2060 fg x hr x mL-1. A two compartmental model yielded first-order rate constants (Ka, K12, K21, Kela and Kelß) of 0.92, 0.49, 0.12, 0.05 and 0.01 fg/hr, respectively. The T1/2a and T1/2ß were 1.14 and 89 hours, respectively. The actual interval between dosing was 20-420 days with no impact on a low intra-individual variation. No covalent [14C]-BaPeq-DNA adducts from peripheral blood mononuclear cells (PBMCs) were detected (LLOD of 10 fg [14C]-BaPeq adducts/mg DNA) 12-72 hours post-dosing negating the use of this cancer biomarker in risk assessment. We assert that the most relevant model for humans is humans. AMS and micro-dosing could be used to enhance the accuracy of pharmacokinetics and potentially risk assessments.

pharmacokinetcs, Polycyclic aromatic hydrocarbons↗

Resolution and Mass Range Performance in Distance-of-flight Mass Spectrometry with a Multichannel Focal-Plane Camera Detector.

Distance-of-flight mass spectrometry (DOFMS) is a velocity-based mass-separation technique in which ions are separated in space along the plane of a spatially selective detector. In the present work, a solid-state charge-detection array, the focal-plane camera (FPC), was incorporated into the DOFMS platform. Use of the FPC with our DOFMS instrument resulted in improvements in analytical performance, usability, and versatility over a previous generation instrument that employed a microchannel-plate/phosphor DOF detector. Notably, FPC detection provided resolution improvements of at least a factor of 2, with typical DOF linewidths of 300 μm (R((fwhm)) = 1000). The merits of solid-state detection for DOFMS are evaluated, and methods to extend the DOFMS mass range are considered.

Array Detection↗

Bayesian Integration and Characterization of Composition C-4 Plastic Explosives Based on Time-of-Flight Secondary Ion Mass Spectrometry and Laser Ablation-Inductively Coupled Plasma Mass Spectrometry

Key elements regarding the use of non-radioactive ionization sources will be presented as related to explosives detection by mass spectrometry and ion mobility spectrometry. Various non-radioactive ionization sources will be discussed along with associated ionization mechanisms pertaining to specific sample types.

Bayesian integration↗

Evaluation of a Reference-Free Collision Cross Section Calibration Strategy for Proteomics Using SLIM-Based High-Resolution Ion Mobility Spectrometry–Mass Spectrometry

Ion mobility spectrometry (IMS) is a gas-phase analytical technique that separates ions with different sizes and shapes and is compatible with mass spectrometry (MS) to provide an additional separation dimension. The rapid nature of the IMS separation combined with the high sensitivity of MS-based detection and the ability to derive structural information on analytes in the form of the property collision cross section (CCS) makes IMS particularly well-suited for characterizing complex samples in -omics applications. In such applications, the quality of CCS from IMS measurements is critical to confident annotation of the detected components in the complex -omics samples. However, most IMS instrumentation in mainstream use requires calibration to calculate CCS from measured arrival times, with the most notable exception being drift tube IMS measurements using multifield methods. The strategy for calibrating CCS values, particularly selection of appropriate calibrants, has important implications for CCS accuracy, reproducibility, and transferability between laboratories. The conventional approach to CCS calibration involves explicitly defining calibrants ahead of data acquisition and crucially relies upon availability of reference CCS values. In this work, we present a novel reference-free approach to CCS calibration which leverages trends among putatively identified features and computational CCS prediction to conduct calibrations post-data acquisition and without relying on explicitly defined calibrants. We demonstrated the utility of this reference-free CCS calibration strategy for proteomics application using high-resolution structures for lossless ion manipulations (SLIM)-based IMS-MS. In conclusion, we first validated the accuracy of CCS values using a set of synthetic peptides and then demonstrated using a complex peptide sample from cell lysate.

59 BASIC BIOLOGICAL SCIENCES↗

Mass spectrometry-based proteomics: existing capabilities and future directions

Mass spectrometry-based proteomics provides a means for identification, characterization, and quantification of biomolecules that are integral components of the processes essential for life. Characterization of proteins present in a biological system at the proteome and sub-proteomes (e.g., the phosphoproteome, proteoglycome, or degradome/peptidome) levels provides a foundation for understanding fundamental aspects as well as potentially a range of translational applications. Emerging technologies such as ion mobility separations coupled with mass spectrometry and microchip-based - proteome measurements combined with continued enhancement of MS instrumentation and separation techniques, such as reversed phase liquid chromatography and potentially capillary electrophoresis, show great promise for both broad undirected as well as targeted measurements and will be critical for e.g., the proteome-wide characterization of post translational modifications and identification, or the verification, and validation of potential biomarkers of disease. MS-based proteomics is also increasingly demonstrating great potential for contributing to our understanding of the dynamics, reactions, and roles proteins and peptides play advancing our understanding of biology on a system wide level for a wide range of applications, from investigations of microbial communities, bioremediation, and human health and disease states alike.

59 BASIC BIOLOGICAL SCIENCES↗

Correlating Nanoscale Secondary Ion Mass Spectrometry and Atom Probe Tomography Analysis of Uranium Enrichment in Metallic Nuclear Fuel

Distribution and enrichment of 235U within nuclear fuels are essential to material performance and reactor safety. With the development of metallic U fuels, understanding 235U homogeneity has become increasingly important, however, it is difficult to map with high spatial, and mass resolution to analyze both matrix and secondary phase precipitates. Here, we analyze 235U enrichment in matrix and carbide phases in LEU-Mo via two chemical imaging modalities: nanoscale secondary ion mass spectrometry (nanoSIMS) and atom probe tomography (APT). NanoSIMS and APT provided consistent results, with no statistically significant difference between measured and nominal enrichment (19.75 % 235U).

U-10Mo, atom probe tomography, nanoscale secondary↗

Lithium formate ion clusters formation during electrospray ionization: Evidence of magic number clusters by mass spectrometry and ab initio calculations

Small cationic and anionic clusters of lithium formate were generated by electrospray ionization and their fragmentations were studied by tandem mass spectrometry (collision-induced dissociation with N{sub 2}). Singly as well as multiply charged clusters were formed in both positive and negative ion modes with the general formulae, (HCOOLi){sub n}Li{sup +}, (HCOOLi){sub n}Li{sub m}{sup m+}, (HCOOLi){sub n}HCOO{sup −}, and (HCOOLi){sub n}(HCOO){sub m}{sup m−}. Several magic number cluster (MNC) ions were observed in both the positive and negative ion modes although more predominant in the positive ion mode with (HCOOLi){sub 3}Li{sup +} being the most abundant and stable cluster ion. Fragmentations of singly charged positive clusters proceed first by the loss of a dimer unit ((HCOOLi){sub 2}) followed by the loss of monomer units (HCOOLi) although the former remains the dominant dissociation process. In the case of positive cluster ions, all fragmentations lead to the magic cluster (HCOOLi){sub 3}Li{sup +} as the most abundant fragment ion at higher collision energies which then fragments further to dimer and monomer ions at lower abundances. In the negative ion mode, however, singly charged clusters dissociated via sequential loss of monomer units. Multiply charged clusters in both positive and negative ion modes dissociated mainly via Coulomb repulsion. Quantum chemical calculations performed for smaller cluster ions showed that the trimer ion has a closed ring structure similar to the phenalenylium structure with three closed rings connected to the central lithium ion. Further additions of monomer units result in similar symmetric structures for hexamer and nonamer cluster ions. Thermochemical calculations show that trimer cluster ion is relatively more stable than neighboring cluster ions, supporting the experimental observation of a magic number cluster with enhanced stability.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Quantifying element incorporation in multispecies biofilms using nanoscale secondary ion mass spectrometry image analysis

Elucidating nutrient exchange in microbial communities is an important step in understanding the relationships between microbial systems and global biogeochemical cycles, but these communities are complex and the interspecies interactions that occur within them are not well understood. Phototrophic consortia are useful and relevant experimental systems to investigate such interactions as they are not only prevalent in the environment, but some are cultivable in vitro and amenable to controlled scientific experimentation. Nanoscale secondary ion mass spectrometry (NanoSIMS) is a powerful, high spatial resolution tool capable of visualizing the metabolic activities of single cells within a biofilm, but quantitative analysis of the resulting data has typically been a manual process, resulting in a task that is both laborious and susceptible to human error. In this work, the authors describe the creation and application of a semiautomated image-processing pipeline that can analyze NanoSIMS-generated data, applied to phototrophic biofilms as an example. The tool employs an image analysis process, which includes both elemental and morphological segmentation, producing a final segmented image that allows for discrimination between autotrophic and heterotrophic biomass, the detection of individual cyanobacterial filaments and heterotrophic cells, the quantification of isotopic incorporation of individual heterotrophic cells, and calculation of relevant population statistics. The authors demonstrate the functionality of the tool by using it to analyze the uptake of 15 N provided as either nitrate or ammonium through the unicyanobacterial consortium UCC-O and imaged via NanoSIMS. The authors found that the degree of 15N incorporation by individual cells was highly variable when labeled with 15 NH 4 + , but much more even when biofilms were labeled with 15 NO 3 – . In the 15 NH 4 + -amended biofilms, the heterotrophic distribution of 15 N incorporation was highly skewed, with a large population showing moderate 15 N incorporation and a small number of organisms displaying very high 15 N uptake. The results showed that analysis of NanoSIMS data can be performed in a way that allows for quantitation of the elemental uptake of individual cells, a technique necessary for advancing research into the metabolic networks that exist within biofilms with statistical analyses that are supported by automated, user-friendly processes.

59 BASIC BIOLOGICAL SCIENCES↗

Indexing Permafrost Soil Organic Matter Degradation Using High-Resolution Mass Spectrometry

Microbial degradation of soil organic matter (SOM) is a key process for terrestrial carbon cycling, although the molecular details of these transformations remain unclear. This study reports the application of ultrahigh resolution mass spectrometry to profile the molecular composition of SOM and its degradation during a simulated warming experiment. A soil sample, collected near Barrow, Alaska, USA, was subjected to a 40-day incubation under anoxic conditions and analyzed before and after the incubation to determine changes of SOM composition. A CHO index based on molecular C, H, and O data was utilized to codify SOM components according to their observed degradation potentials. Compounds with a CHO index score between –1 and 0 in a water-soluble fraction (WSF) demonstrated high degradation potential, with a highest shift of CHO index occurred in the N-containing group of compounds, while similar stoichiometries in a base-soluble fraction (BSF) did not. Additionally, compared with the classical H:C vs O:C van Krevelen diagram, CHO index allowed for direct visualization of the distribution of heteroatoms such as N in the identified SOM compounds. We demonstrate that CHO index is useful not only in characterizing arctic SOM at the molecular level but also enabling quantitative description of SOM degradation, thereby facilitating incorporation of the high resolution MS datasets to future mechanistic models of SOM degradation and prediction of greenhouse gas emissions.

Environmental Molecular Sciences Laboratory↗