Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SPARK CHAMBER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

EGRET detection of high energy gamma rays from the gamma-ray burst of 3 May 1991

On May 3, 1991, the Energetic Gamma Ray Experiment Telescope on the Compton Gamma Ray Observatory detected a gamma-ray burst both in the energy measurement subsystem and independently in the spark chamber assembly. Six individual photons were detected in the spark chamber, allowing a determination of the burst arrival direction which was l(II) = 171.9 deg +/- 1.3 deg, b(II) = 5.3 deg +/- 1.1 deg. Three energy spectra were measured from 1 to 200 MeV; they were measured during the first second after the Burst and Transient Sources Experiment trigger, the next two seconds, and the subsequent four seconds. The first two spectra exhibit a similar differential spectra index of about -2.2 with no apparent high-energy cut-off. By the time of the third spectrum, an additional soft component is evident.

Schneid, E. J.↗

50-500 MeV observations of LMC supernova 1987A

Since the discovery of the supernova outburst in the LMC in 1987, two attempts (on day 55 and day 407) have been made to measure the high energy gamma-ray flux in the range 50-500 MeV, by using a balloon-borne spark chamber telescope. On day 55, no positive signal was seen from the source. A 3 sigma upper limit of 2.9 x 10 to the -5th ph/sq cm s was obtained after the analysis of the spark chamber data. Preliminary analysis of the quick look data obtained in the second flight shows that the gamma-ray flux even on day 407 was less than 9 x 10 to the -4th ph/sq cm s (3 sigma).

Sumner, T. J.↗

Performance of and planned improvements to a mountain altitude cosmic ray mass spectrometer

A cosmic ray mass spectrometer with superconducting magnet, wire spark chambers, and time-of-flight scintillation counters has been operated at an altitude of 2750 meters. Various specifications of the spectrometer are presented and the method of event analysis described. Corrections to the data, resolutions and efficiencies of the spark chambers, and momentum resolution are discussed. Recent and planned improvements of the apparatus are indicated.

Jones, J. J.↗

The time-of-flight system on the Goddard medium energy gamma-ray telescope

A scintillation counter time-of-flight system has been incorporated into the Goddard 50 cm by 50 cm spark chamber gamma-ray telescope. This system, utilizing constant fraction timing and particle position compensation, digitizes up to 10 ns time differences to six bit accuracy in less than 500 ns. Event selection decisions, discriminating against upward-moving particles, are made prior to spark chamber triggering. The performance of this system during a November 1978 balloon flight is discussed.

Ross, R. W.↗

Observation of gamma ray bursts and flares by the EGRET telescope on the Compton Gamma Ray Observatory

The Energetic Gamma Ray Experiment Telescope (EGRET) on the Compton Gamma Ray Observatory has observed energetic gamma ray bursts and flares. On May 3, 1991, EGRET detected a gamma ray burst both in the energy measuring NaI (Tl) scintillator and independently in the spark chamber imaging assembly. The NaI spectra were accumulated by a special BURST mode of EGRET. The spectra were measured over a range from 1 to 200 MeV, in three sequential spectra of 1,2, and 4 seconds. During the peak of the burst, six individual gamma rays were detected in the spark chamber, allowing a determination of the burst arrival direction. The intense flares of June were also detected. A solar flare on June 4 was observed to last for several minutes and for a brief time, less than a minute, had significant emission of gamma rays exceeding 150 MeV.

Schneid, E. J.↗

An investigation of high-multiplicity gamma events in pp collisions with c.m. energies between 22 and 62 GeV

An experiment was conducted at the CERN intersecting storage rings using colliding proton beams to investigate high-multiplicity gamma-ray events. The objective of the study was to reveal certain features of multiple pion production as well as other possible mechanisms of gamma-ray production. The detector system consisted of ten planes of spark chambers, three scintillation counter hodoscopes and two arrays of lead-glass Cerenkov counters, the first array containing 16 counters and the second, 60 counters. The event trigger was obtained from the Cerenkov counters, and the energies in all the Cerenkov counters after trigger, as well as the information on all the charged particles given by the scintillation counters and spark chambers were recorded on magnetic tape. The relationship between the number of gamma-rays per event and the number of Cerenkov counters triggered by a neutral secondary was established by means of a Monte Carlo calculation.

Dell, G. F.↗

Neural network classification of questionable EGRET events

High energy gamma rays (greater than 20 MeV) pair producing in the spark chamber of the Energetic Gamma Ray Telescope Experiment (EGRET) give rise to a characteristic but highly variable 3-D locus of spark sites, which must be processed to decide whether the event is to be included in the database. A significant fraction (about 15 percent or 10(exp 4) events/day) of the candidate events cannot be categorized (accept/reject) by an automated rule-based procedure; they are therefore tagged, and must be examined and classified manually by a team of expert analysts. We describe a feedforward, back-propagation neural network approach to the classification of the questionable events. The algorithm computes a set of coefficients using representative exemplars drawn from the preclassified set of questionable events. These coefficients map a given input event into a decision vector that, ideally, describes the correct disposition of the event. The net's accuracy is then tested using a different subset of preclassified events. Preliminary results demonstrate the net's ability to correctly classify a large proportion of the events for some categories of questionables. Current work includes the use of much larger training sets to improve the accuracy of the net.

Meetre, C. A.↗

The Nagoya cosmic-ray muon spectrometer 3, part 2: Track detector

The twelve wide gap spark chambers were utilized as the track detectors of the Nagoya cosmic-ray muon spectrometer not only to obtain the precise locations of particles, but also to get some information about the correspondences between segments of trajectories. The area of each chamber is 150 x 70 sq cm and the width of a gap is 5 cm. The gas used is He at the atmospheric pressure. Each three pairs of them are placed on both sides of the deflection magnet. All images of sparks for each event are projected through the mirror system and recorded by two cameras stereoscopically. The mean detection efficiency of each chamber is 95 + or - 2% and the spacial resolution (jitter and drift) obtained from the prototype-experiment is 0.12 mm. Maximum detectable momentum of the spectrometer is estimated at about 10 TeV/c taking into account these characteristics together with the effects of the energy loss and multiple Coulomb scattering of muons in the iron magnet.

Shibata, S.↗

High-voltage spark atomic emission detector for gas chromatography

A dc-powered, double-gap, miniature nanosecond spark source for emission spectrochemical analysis of gas chromatographic effluents is described. The spark is formed between two thoriated tungsten electrodes by the discharge of a coaxial capacitor. The spark detector is coupled to the gas chromatograph by a heated transfer line. The gas chromatographic effluent is introduced into the heated spark chamber where atomization and excitation of the effluent occurs upon breakdown of the analytical gap. A microcomputer-controlled data acquisition system allows the implementation of time-resolution techniques to distinguish between the analyte emission and the background continuum produced by the spark discharge. Multiple sparks are computer averaged to improve the signal-to-noise ratio. The application of the spark detector for element-selective detection of metals and nonmetals is reported.

Calkin, C. L.↗

Progress report on a new search for free e/3 quarks in the cores of 10(15) - 10(16) eV air showers

The Leeds 3 sq m Wilson cloud chamber is being used in a new search for free e/3 quarks close to the axes of 10 to the 15th power - 10 to the 16th power eV air showers. A ratio trigger circuit is used to detect the incidence of air shower cores; the position of the shower center and the axis direction are determined from photographs of current-limited spark chambers. It is thus possible, for the first time, to know where we have looked for quarks in air showers and to select for scanning only those cloud chamber photographs where we have good evidence that the shower axis was close to the chamber. 250 g/sq cm of lead/concrete absorber above the cloud chamber serve to reduce particle densities and make a quark search possible very close to the shower axes. The current status of the search is given.

Hodson, A. L.↗

Fiberglas balloon gondola.

Fiberglas balloon gondola used to eliminate environmental problems in photomultipliers and spark chambers carried by high altitude balloons

HIGH ALTITUDE BALLOON PROGRAM↗