Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SLIPSTREAM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Fluctuating pressures on wing surfaces in the slipstream of a single-rotor propfan

Measurements of the fluctuating pressure levels (FPLs) induced on a Propfan Test Assessment wing by the SR-7L propfan slipstream within the airplane flight envelope were obtained as a function of propfan operating conditions. It is shown that FPLS were high over most of the flight envelope, and that the spectra were dominated by the propfan first-order blade passage frequency tone. The highest FPLs were found at the lowest aircraft test altitudes and Mach numbers and for propfan conditions of lowest rotational tip speed and highest power.

Swift, G.↗

A multiblock/multigrid Euler analysis of a propfan transport with wing-mounted nacelles, including slipstream effects

A multiblock/multigrid computation of the inviscid flow over a wing-mounted propfan transport with propwash is presented. An explicit multistage scheme drives the integral Euler equations to a steady state solution, while an actuator disk approximates the slipstream effects of the propfan blades. Practical applications of detailed surface gridding, multiple block field grids and multigrid convergence acceleration are demonstrated.

Nishida, Brian A.↗

Reduction in efficiency of propellers due to slipstream

In the slipstream behind a propeller there is a considerable amount of kinetic energy which has been imparted to it by the engine without producing any corresponding propeller thrust. The increased absorption of power reduces the propeller efficiency. Attention has been previously directed to this question by Bendemann and Madelung and other writers. Their contribution serves to verify a simple method of calculating the reduction in the propeller efficiency due to the slip stream. That method of calculation is given here. Explanations and examples are given for as single propeller and for two propellers mounted in tandem.

Munk, Max M↗

The Theory of Propellers III : the Slipstream Contraction with Numerical Values for Two-Blade and Four-Blade Propellers

As the conditions of the ultimate wake are concerned both theoretically and practically, the magnitude of the slipstream contraction has been calculated. It will be noted that the contraction in a representative case is of the order of only 1 percent of the propeller diameter. In consequence, all calculations need involve only first-order effects. Curves and tables are given for the contraction coefficient of two-blade and four-blade propellers for various values of the advance ratio; the contraction coefficient is defined as the contraction in the diameter of the wake helix in terms of the wake diameter at infinity. The contour lines of the wake helix are also shown at four values of the advance ratio in comparison with the contour lines for an infinite number of blades.

Theodorsen, Theodore↗

Effect of Propeller Slipstream on Wing and Tail

The results of wind tunnel tests for the determination of the effect of a jet on the lift and downwash of a wing are presented in this report. In the first part, a jet without rotation and with constant velocity distribution is considered - the jet being produced by a specially designed fan. Three-component, pressure distribution, and downwash measurements were made and the results compared with existing theory. The effect of a propeller slipstream was investigated in the second part. In the two cases the jet axis coincided with the undisturbed wind direction. In the third part the effect of the inclination of the propeller axis to the wing chord was considered, the results being obtained for a model wing with running propeller.

Stuper, J↗

Some experiments on the slipstream effect

The models designated "Torino 30, 31, 32" are horizontal tail surfaces of rectangular, triangular, and elliptical plan form and all of the same profile section. Tests were carried out with the object being to determine the effect of the propeller slipstream on the aerodynamical characteristics of the horizontal stabilizer. The results presented correspond to a first series of tests made without an interposed wing and in which the distance between the plane of the propeller disk and the tail was maintained constant.

Ferrari, C↗

Rotor Vortex Filaments: Living on the Slipstream's Edge

The purpose of this paper is to gain a better understanding of rotor wake evolution in hover and axial flow by deriving an analytical solution for the time dependent behavior of vortex filament circulation and core size. This solution is applicable only for vortex filaments in the rotor far-wake. A primarily inviscid vortex/shear layer interaction (where the slipstream boundary is modeled as a shear layer) has been identified in this analytical treatment. This vortex/shear layer interaction results in decreasing, vortex filament circulation and core size with time. The inviscid vortex/shear layer interaction is shown, in a first-order treatment, to be of greater magnitude than viscous diffusion effects. The rate of contraction, and ultimate collapse, of the vortex filament core is found to be directly proportional to the rotor inflow velocity. This new insight into vortex filament decay promises to help reconcile several disparate observations made in the literature and will, hopefully, promote new advances in theoretical modeling of rotor wakes.

Young, Larry A.↗

Investigation of Longitudinal and Lateral Stability Characteristics of a Six-Propeller Deflected-Slipstream VTOL Model with Boundary-Layer Control Including Effects of Ground Proximity

An investigation of the longitudinal and lateral stability and control and Performance characteristics of a six-propeller deflected- slipstream vertical-take-off-and-landing (VTOL) model in the transition speed range was conducted in the 17-foot test section of the Langley 300-MPH 7- by 10-foot tunnel. A complete analysis of the data was not conducted. A modest amount of blowing boundary-layer control was necessary to achieve transition without wing stall.

Grunwald, Kalman J.↗

Lateral Stability and Control Characteristics of a Four-Propeller Deflected-Slipstream VTOL Model Including the Effects of Ground Proximity

The investigation of the lateral-directional stability and control characteristics of a four-propeller deflected-slipstream VTOL model in the transition speed range was conducted in the 17-foot test section of the Langley 300-MPH 7- by 10-foot tunnel. A large fairing on top of the rear fuselage was needed to eliminate directional instability in the power-off flaps-retracted condition. Even with this fairing some instability at small sideslip angles remained for power-on conditions with low flap deflections. The configuration exhibited a high level of dihedral effect which, coupled with the directional instability, will probably produce an undesirable Dutch roll oscillation.

Kuhn, Richard E.↗

Effectiveness of Boundary-layer Control, Obtained by Blowing over a Plain Rear Flap in Combination with a Forward Slotted Flap, in Deflecting a Slipstream Downward for Vertical Take-off

The wing employed in this investigation had a 67-percent-chord slotted flap in combination with a 33-percent-chord plain rear flap equipped with a full-span blowing nozzle. The tests were conducted in a static-thrust facility at the Langley Aeronautical Laboratory. The investigation indicated that the plain rear flap alone with a low momentum coefficient for boundary-layer control provided larger turning angles than the combined slotted and plain flaps without boundary-layer control.

HIGH-LIFT DEVICES - COMPLETE WINGS↗

Analysis of Air-Purifying Respirator (APR) and Powered Air-Purifying Respirator (PAPR) Cartridge Performance Testing on a Hanford AP Tank Farm Exhauster Slipstream: Volume 2 Raw Analytical Data

As the Tank Operations Contractor for U.S. Department of Energy operations at the Hanford site in Washington State, Washington River Protection Solutions (WRPS) is responsible for managing highly radioactive wastes stored in tanks at Hanford. WRPS tests air-purifying respirator (APR) and powered air-purifying respirator (PAPR) chemical cartridges commonly used at Hanford Tank Farms to determine the period of time that the cartridges would provide adequate performance for APRs and PAPRs used to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPC) from any vapors exiting headspaces in the storage tanks. The Occupational Safety and Health Administration (OSHA) Standard promulgated in Title 29 of the Code of the Federal Regulations (CFR) 1910.134(d)(3)(iii)(b)(2) specifies that for protection against gases and vapors, employers shall implement a schedule for cartridges to ensure that change-outs occur before the end of service life. The change schedule can be based on objective information or data that ensures cartridge change-outs occur before the end of their service life.[2-5] The primary function of the WRPS Cartridge Test Program is to obtain objective data to determine service lives for the APR and PAPR cartridges used at Hanford Tank Farms. WRPS contracted with Pacific Northwest National Laboratory to analyze the test data and offer an independent analysis and any recommendations. Volume 1 of this report summarizes data analysis of APR and PAPR cartridge testing on vapors from the AP tank farm exhauster. Previous testing of APR cartridges was conducted on the AP exhauster in June 2016. However, an AP exhauster upgrade was completed in September 2016. Two different APR cartridges from SCOTT Safety (Monroe, North Carolina) were assessed for the new AP exhauster source, along with two different PAPR cartridges—one from MSA Safety Inc. (Pittsburgh, Pennsylvania) and another from 3M (Maplewood, Minnesota). Volume 2 provides an introduction to the raw data, including analytical laboratory analysis results that supported the analysis and conclusions documented in Volume 1.

61 RADIATION PROTECTION AND DOSIMETRY↗

Sorbent Based Post-Combustion CO 2 Slipstream Testing

TDA Research, Inc. has developed a low-cost sorbent (alkalized alumina) based technology for post-combustion CO 2 capture. The sorbent runs in an isothermal process for adsorption and regeneration. Neither temperature swing nor pressure swing is needed. TDA designed a system which operated 10 fixed beds to simulate a moving bed process. The flow pattern was optimized to minimize the steam usage for regeneration. An excellent sorbent (Batch 1) was also developed with collaboration with our partner. The sorbent degraded after long term operation. We developed a reprocessing procedure, which can be conducted in situ, to restore the sorbent capture capacity as the fresh sorbent after running for about 1250 hours. The reprocessing extended the sorbent longevity significantly. TDA designed a pilot unit (40’ x 32’ x 11.5’), processing flue gas equivalent to 0.5 MW of power generation. It had 10 beds and each bed could hold 1.75 m 3 of sorbent. We worked with Springs Fabrication, Inc. to complete the construction of the pilot unit. It was then shipped and installed at NCCC. The pilot unit was kept running in 24-hour mode when the flue gas and steam were available. It could run automatically without operator on site. Parametric and long-term (2 months) tests were carried out successfully. The results showed that TDA’s process can achieve 90% capture and 95% CO 2 purity for both coal and NG flue gases. For coal flue gas, the system reached performance target when processing up to 0.62 MW flue gas, 24% higher than the design capacity. Thus, capital cost could be saved on the reactors and sorbent. The strip air flow was designed to be 0.25 of that of the flue gas. The test data showed the strip/flue ratio can be reduced to as little as 0.18, which saves the power consumption for the strip air blower. The pressure drop was found to be lower than what the empirical equation calculated. The sorbent still had 91.7% of original capacity after 3-month test. With the data from the pilot test, we updated the TEA. For a 550-MW e supercritical coal fired power plant with CO 2 capture, the capture cost for TDA’s process is $34.9/tonne CO 2 captured, which meets DOE’s goal of $40/tonne and is 17.1% less than the DOE baseline Case 12. Therefore, TDA’s process has a good potential for commercialization.

01 COAL, LIGNITE, AND PEAT↗

Slipstream Testing of Amine-Based Solvents at a Low-Rank Coal-Fired Power Plant

Conference presentation for 38th Annual International Pittsburgh Coal Conference, Virtual, September 20–23, 2021. To better assess mitigation strategies for aerosol reduction to extend solvent life, the University of North Dakota Energy & Environmental Research Center (EERC) installed a pilot-scale CO 2 absorption system at a lignite-fired plant in central North Dakota. The pilot-scale system was operated using both commercial KS-1™ solvent and advanced KS-21™ solvent provided by Mitsubishi Heavy Industries (MHI). MHI’s proprietary amine emission reduction unit (AERU™) technology was installed downstream of the absorber columns to reduce solvent losses by recovering amines at the system outlet. Fine particulate loading was measured throughout the capture system with and without a WESP operating and using both solvents. Captured particulate was brought back to the EERC to be analyzed for chemical composition and to be examined by scanning electron microscopy for particulate structure. These variables were then correlated to performance of particulate control devices in reducing aerosol formation and solvent losses.

01 COAL, LIGNITE, AND PEAT↗