Thermal Analysis of the Advanced Technology Large Aperture Space Telescope (ATLAST) 8 Meter Primary Mirror

The Advanced Technology Large Aperture Space Telescope (ATLAST) preliminary design concept consists of an 8 meter diameter monolithic primary mirror enclosed in an insulated, optical tube with stray light baffles and a sunshade. ATLAST will be placed in orbit about the Sun-Earth L2 and will experience constant exposure to the sun. The insulation on the optical tube and sunshade serve to cold bias the telescope which helps to minimize thermal gradients. The primary mirror will be maintained at 280K with an active thermal control system. The geometric model of the primary mirror, optical tube, sun baffles, and sunshade was developed using Thermal Desktop(R) SINDA/FLUINT(R) was used for the thermal analysis and the radiation environment was analyzed using RADCAD(R). A XX node model was executed in order to characterize the static performance and thermal stability of the mirror during maneuvers. This is important because long exposure observations, such as extra-solar terrestrial planet finding and characterization, require a very stable observatory wave front. Steady state thermal analyses served to predict mirror temperatures for several different sun angles. Transient analyses were performed in order to predict thermal time constant of the primary mirror for a 20 degree slew or 30 degree roll maneuver. This paper describes the thermal model and provides details of the geometry, thermo-optical properties, and the environment which influences the thermal performance. All assumptions that were used in the analysis are also documented. Parametric analyses are summarized for design parameters including primary mirror coatings and sunshade configuration. Estimates of mirror heater power requirements are reported. The thermal model demonstrates results for the primary mirror heated from the back side and edges using a heater system with multiple independently controlled zones.

Hornsby, Linda↗

Thermal Analysis of Compressible CO2 Flow for Major Equipment of Fire Detection System

A thermal analysis of the compressible CO2 flow for the Portable Fire Extinguisher (PFE) system has been performed. The purpose of this analysis is to determine the discharged CO2 mass from the PFE tank through the Temporary Sleep Station (TeSS) nozzle in reflecting to the latest design of the extended nozzle, and to evaluate the thermal issues associated to the latest nozzle configuration. A SINDA/FLUINT model has been developed for this analysis. The model includes the PFE tank and the TeSS nozzle, and both have initial temperature of 72 of. In order to investigate the thermal effect on the nozzle due to discharging C02, the PFE TeSS nozzle pipe has been divided into three segments. This model also includes heat transfer predictions for PFE tank inner and outer wall surfaces. The simulation results show that the CO2 discharge rates have fulfilled the minimum flow requirements that the PFE system discharges 3.0 Ibm CO2 in 10 seconds and 5.5 Ibm of CO2 in 45 seconds during its operation. At 45 seconds, the PFE tank wall temperature is 63 OF, and the TeSS nozzle cover wall temperatures for the three segments are 47 OF, 53 OF and 37 OF, respectively. Thermal insulation for personal protection is used for the first two segments of the TeSS nozzle. The simulation results also indicate that at 50 seconds, the remaining CO2 in the tank may be near the triple point (gas, liquid and solid) state and, therefore, restricts the flow.

Zhang, Michael Y.↗

Thermal Analysis of Compressible CO2 Flow for PFE TeSS Nozzle of Fire Detection System

A thermal analysis of the compressible CO2 flow for the Portable Fire Extinguisher (PFE) system has been performed. A SINDA/FLUINT model has been developed for this analysis. The model includes the PFE tank and the TeSS nozzle, and both have initial temperature of 72 F. In order to investigate the thermal effect on the nozzle due to discharging CO2, the PFE TeSS nozzle pipe has been divided into three segments. This model also includes heat transfer predictions for PFE tank inner and outer wall surfaces. The simulation results show that the CO2 discharge rates have fulfilled the minimum flow requirements that the PFE system discharges 3.0 Ibm CO2 in 10 seconds and 5.5 Ibm of CO2 in 45 seconds during its operation. At 45 seconds, the PFE tank wall temperature is 63 F, and the TeSS nozzle cover wall temperatures for the three segments are 47 F, 53 F and 37 F, respectively. Thermal insulation for personal protection is used for the first two segments of the TeSS nozzle. The simulation results also indicate that at 50 seconds, the remaining CO2 in the tank may be near the triple point (gas, liquid and solid) state and, therefore, restricts the flow.

Zhang, Y. Michael↗

Modeling of Heat Transfer and Ablation of Refractory Material Due to Rocket Plume Impingement

CR Tech's Thermal Desktop-SINDA/FLUINT software was used in the thermal analysis of a flame deflector design for Launch Complex 39B at Kennedy Space Center, Florida. The analysis of the flame deflector takes into account heat transfer due to plume impingement from expected vehicles to be launched at KSC. The heat flux from the plume was computed using computational fluid dynamics provided by Ames Research Center in Moffet Field, California. The results from the CFD solutions were mapped onto a 3-D Thermal Desktop model of the flame deflector using the boundary condition mapping capabilities in Thermal Desktop. The ablation subroutine in SINDA/FLUINT was then used to model the ablation of the refractory material.

Harris, Michael F.↗

An Upgrade of the Aeroheating Software "MINIVER"

Many software packages assist engineers with performing flight vehicle analysis, but some of these packages have gone many years without updates or significant improvements to their workflows. One such software, known as MINIVER, is a powerful yet lightweight tool that is used for aeroheating analyses. However, it is an aging program that has not seen major improvements within the past decade. As part of a collaborative effort with Florida Institute of Technology, MINIVER has received a major user interface overhaul, a change in program language, and will be continually receiving updates to improve its capabilities. The user interface update includes a migration from a command-line interface to that of a graphical user interface supported in the Windows operating system. The organizational structure of the preprocessor has been transformed to clearly defined categories to provide ease of data entry. Helpful tools have been incorporated, including the ability to copy sections of cases as well as a generalized importer which aids in bulk data entry. A visual trajectory editor has been included, as well as a CAD Editor which allows the user to input simplified geometries in order to generate MINIVER cases in bulk. To demonstrate its continued effectiveness, a case involving the JAXA OREX flight vehicle will be included, providing comparisons to captured flight data as well as other computational solutions. The most recent upgrade effort incorporated the use of the CAD Editor, and current efforts are investigating methods to link MINIVER projects with SINDA/Fluint and Thermal Desktop.

Louderback, Pierce M.↗

A Upgrade of the Aeroheating Software "MINIVER"

Many software packages assist engineers with performing flight vehicle analysis, but some of these packages have gone many years without updates or significant improvements to their workflows. One such software package, known as MINIVER, is a powerful yet lightweight tool used for aeroheating analyses. However, it is an aging program that has not seen major improvements within the past decade. As part of a collaborative effort with the Florida Institute of Technology, MINIVER has received a major user interface overhaul, a change in program language, and will be continually receiving updates to improve its capabilities. The user interface update includes a migration from a command-line interface to that of a graphical user interface supported in the Windows operating system. The organizational structure of the pre-processor has been transformed to clearly defined categories to provide ease of data entry. Helpful tools have been incorporated, including the ability to copy sections of cases as well as a generalized importer which aids in bulk data entry. A visual trajectory editor has been included, as well as a CAD Editor which allows the user to input simplified geometries in order to generate MINIVER cases in bulk. To demonstrate its continued effectiveness, a case involving the JAXA OREX flight vehicle will be included, providing comparisons to captured flight data as well as other computational solutions. The most recent upgrade effort incorporated the use of the CAD Editor, and current efforts are investigating methods to link MINIVER projects with SINDA/Fluint and Thermal Desktop.

Louderback, Pierce↗

The January 2015 Repressurization of ISS ATCS Loop B - Analysis Limitations and Concerns

In January 2013 a false ammonia leak alarm resulted in the shutdown and partial depressurization of one of the two International Space Station (ISS) External Active Thermal Control System (EATCS) loops. The depressurization resulted in a vapor bubble of 18 liters in warm parts of the stagnant loop. To repressurize the loop and regain system operation, liquid would have to be moved from the Ammonia Tank Assembly (ATA) into the loop. This resulted in the possibility of moving cold (as low as ‐30 C) ammonia into the water‐filled Internal Active Thermal Control System (IATCS) interface heat exchangers. Before moving forward, the freezing potential of the repressurization was evaluated through analysis - using both a Thermal Desktop SINDA/FLUINT model and hand calculations. The models yielded very different results, but both models indicated that heat exchanger freezing was not an issue. Therefore, the repressurization proceeded. The presentation describes the physical situation of the EATCS prior to repressurization and discusses the potential limits and pitfalls of the repressurization. The pre‐repressurization analytical models and their results are discussed. The successful repressurization is describled and the results of a post‐event model assessment is detailed.

Ungar, Eugene↗

Thermal Testing and Model Correlation of the Magnetospheric Multiscale (MMS) Observatories

The Magnetospheric Multiscale (MMS) mission is a Solar Terrestrial Probes mission comprising four identically instrumented spacecraft that will use Earth's magnetosphere as a laboratory to study the microphysics of three fundamental plasma processes: magnetic reconnection, energetic particle acceleration, and turbulence. This paper presents the complete thermal balance (TB) test performed on the first of four observatories to go through thermal vacuum (TV) and the minibalance testing that was performed on the subsequent observatories to provide a comparison of all four. The TV and TB tests were conducted in a thermal vacuum chamber at the Naval Research Laboratory (NRL) in Washington, D.C. with the vacuum level higher than 1.3 x 10 (sup -4) pascals (10 (sup -6) torr) and the surrounding temperature achieving -180 degrees Centigrade. Three TB test cases were performed that included hot operational science, cold operational science and a cold survival case. In addition to the three balance cases a two hour eclipse and a four hour eclipse simulation was performed during the TV test to provide additional transient data points that represent the orbit in eclipse (or Earth's shadow) The goal was to perform testing such that the flight orbital environments could be simulated as closely as possible. A thermal model correlation between the thermal analysis and the test results was completed. Over 400 1-Wire temperature sensors, 200 thermocouples and 125 flight thermistor temperature sensors recorded data during TV and TB testing. These temperature versus time profiles and their agreements with the analytical results obtained using Thermal Desktop and SINDA/FLUINT are discussed. The model correlation for the thermal mathematical model (TMM) is conducted based on the numerical analysis results and the test data. The philosophy of model correlation was to correlate the model to within 3 degrees Centigrade of the test data using the standard deviation and mean deviation error calculation. Individual temperature error goal is to be within 5 degrees Centigrade and the heater power goal is to be within 5 percent of test data. The results of the model correlation are discussed and the effect of some material and interface parameters on the temperature profiles are presented.

Correlation↗

The Safe Removal of Frozen Air from the Annulus of an LH2 Storage Tank

Large Liquid Hydrogen (LH2) storage tanks are vital infrastructure for NASA. Eventually, air may leak into the evacuated and perlite filled annular region of these tanks. Although the vacuum level is monitored in this region, the extremely cold temperature causes all but the helium and neon constituents of air to freeze. A small, often unnoticeable pressure rise is the result. As the leak persists, the quantity of frozen air increases, as does the thermal conductivity of the insulation system. Consequently, a notable increase in commodity boil-off is often the first indicator of an air leak. Severe damage can result from normal draining of the tank. The warming air will sublimate which will cause a pressure rise in the annulus. When the pressure increases above the triple point, the frozen air will begin to melt and migrate downward. Collection of liquid air on the carbon steel outer shell may chill it below its ductility range, resulting in fracture. In order to avoid a structural failure, as described above, a method for the safe removal of frozen air is needed. A thermal model of the storage tank has been created using SINDA/FLUINT modeling software. Experimental work is progressing in an attempt to characterize the thermal conductivity of a perlite/frozen nitrogen mixture. A statistical mechanics model is being developed in parallel for comparison to experimental work. The thermal model will be updated using the experimental/statistical mechanical data, and used to simulate potential removal scenarios. This paper will address methodologies and analysis techniques for evaluation of two proposed air removal methods.

cryogenic insulation↗

Thermal Modeling of Zero Boil Off Tank Experiment

Understanding fluid behavior in microgravity environments is essential to further development of cryogenic storage in space environments. The Zero Boil Off Tank (ZBOT) experiment was designed to investigate two-phase pressurization and depressurization of a tank in a microgravity environment. The test fluid was the refrigerant Perfluoro-normal-Pentane (PNP). Thermal modeling for the ZBOT model was conducted using Thermal Desktop and SINDA/FLUINT. The temperature distribution within the fluid of the tank is of particular interest. This particular work is centered on ascertaining the thermal behavior of the refrigerant in order to build more complete models of fluid in microgravity. Separate cases were run modeling experiments that were conducted both on the ground and on the International Space Station (ISS) to compare 1g and microgravity environments. The microgravity modeling cases consisted of a fluid lump representing the vapor ullage suspended in a solid to represent the liquid. Mass flow between the liquid and vapor was modeled using the Schrage equation for mass flow. Initial results indicate that the pressure rise and temperature increase within the fluid closely align with the experimental data by matching initial conditions of the experiment. This work is ongoing and will yield further insights into the thermal behavior of fluid mixing in microgravity.

low-gravity fluid modeling↗

Two-Phase Convection Heat Transfer Correlations for Liquid Hydrogen Pipe Chilldown

Recently, heat transfer correlations based on liquid nitrogen (LN2) and liquid hydrogen (LH2) pipe quenching data were developed to improve the predictive accuracy of lumped node codes like SINDA/FLUINT and the Generalized Fluid System Simulation Program (GFSSP). After implementing these correlations into both programs, updated model runs showed strong improvement in LN2 pipe chilldown modeling but only modest improvement in LH2 modeling. Due to large differences in thermal and fluid properties between the two fluids, results indicated a need to develop a separate set of LH2-only correlations to improve the accuracy of the simulations. This paper presents a new set of two-phase convection heat transfer correlations based on LH2 pipe quenching data. A correlation to predict the bulk vapor temperature was developed after analysis showed that high amounts of thermal nonequilibrium of the liquid and vapor phases occurred during film boiling of LH2. Implemented in a numerical model, the new correlations achieve a mean absolute error of 19.5 K in the predicted wall temperature when compared to recent LH2 pipe chilldown data, an improvement of 40% over recent GFSSP predictions. This correlation set can be implemented in simulations of the transient LH2 chilldown process. Such simulations are useful for predicting the chilldown time and boil-off mass of LH2 for applications such as the transfer of LH2 from a ground storage tank to the rocket vehicle propellant tank, or through a rocket engine feedline during engine startup.

critical heat flux↗

On-Orbit Xenon Refueling Loading Times and Transient Analysis

The Power and Propulsion Element (PPE) of the Lunar Orbital Platform-Gateway will demonstrate the first on-orbit refueling of xenon propellant for a solar electric propulsion system. An analysis was performed in Microsoft Excel to determine what factors influence the overall refueling time of a single 2,000-kilogram capacity xenon propellant tank, as well as provide estimates for overall refueling duration. Due to the high heat of compression of xenon, the propellant tank could exceed its maximum allowable temperature during refueling if the xenon flow rate and temperature are unregulated. In order to prevent overheating, a logic based "bang-bang" operation was used for refueling, shutting off the mass feed when the tank reached a maximum temperature. Heat is removed from the tank via radiation to the surrounding spacecraft bus. The analysis shows that optimizing key parameters such as mass flow rate into the tank, residual propellant in the tank during the onset of refueling, and tank diameter significantly reduces the overall refueling duration. Optimization is not straightforward, however, as the loading time does not trend monotonically with the parameters. Overall, the most significant impact on loading duration comes from altering the residual propellant in the tank. Increasing the mass of residual propellant from 2 percent to 20 percent reduces the overall refueling duration by 56 percent. Future work based on this analysis includes creation of a SINDA/FLUINT model and building a ground-based xenon refueling system emulator.

Xenon↗

Case Study of Using Flocad to Model a Ground Test Station Ln2 Heat Exchanger

This paper presents a case study of using FLOCAD to model the heat transfer and boiling flow behavior of a Liquid Nitrogen (LN2) ground station equipment heat exchanger. The unique aspect of this work is that is one of very few studies documenting the use of FLOCAD in the spacecraft thermal control community. The results of the simulations described herein were used to guide and plan the execution of thermal vacuum testing spacecraft hardware using a ground test heat exchanger such as the one modeled herein. The paper will review the theory of two-phase boiling flow and correlations used by SINDA/FLUINT as well as the terminology and nomenclature used within Thermal Desktop / FLOCAD regarding two-phase boiling flow heat transfer modeling and simulation. Results for using the ground station heat exchanger as a heat sink in a thermal vacuum test set up are shown in order to demonstrate the set-up and execution of a typical FLOCAD model. Results indicate that properly modeling of the two-phase behavior is critical in order to ascertain the time constant associated with the heat exchanger, as well as understanding the temperature distribution across the test equipment and prediction of required LN2 flowrates to be used during testing. The paper is meant to augment the FLOCAD user’s manual and serve as a tutorial for thermal engineers and analysts wishing to learn and apply FLOCAD to industrial problems.

Anderson, Kevin R.↗

A Warm Garage for a Lunar Rover

Approach: One approach to heating a rover during the lunar night is the so-called thermal wadis concept [1]. This involves heating the regolith with solar concentrators and placing the rover on the heated surface for the night. Since the regolith is heated by a relatively weak heat flux, a high thermal conductivity is required for heating a sufficiently large mass of regolith. However, lunar regolith has a low thermal conductivity. Therefore, the concept involves increasing the conductivity by sintering the regolith, which requires a significant energy input and complex procedures. Here we propose an alternative approach where the low thermal conductivity of regolith is an advantage. Specifically, we propose to use a highly exothermic combustible mixture for heat generation. The mixture pellets are placed in the surface layer of regolith and ignited. The combustion forms condensed products and releases heat, which then slowly spreads to the surrounding regolith. Heat can also be transferred, for example, by heat pipes, into radiant heating surfaces installed on the ground. A greenhouse that transmits sunlight during the day and decreases the radiative heat losses during the night can also be installed. Selection of the Heat-generating Mixture: The reactive mixture should have a high specific energy and generate only condensed products since gases could disturb the regolith layer, carry enthalpy out of the system, and lead to an explosion. There are mixtures, (sometimes called pyrolants) that possess very high specific energies. One example is magnesium-Teflon-Viton mixtures used in flares. However, they produce gases and may cause explosions. Other mixtures that include magnesium cannot be used either because of the high vapor pressure of Mg at temperatures well below the combustion temperature. Recently, mixtures that involve lithium peroxide (Li2O2) have been proposedfor using in space power systems [2]. However, they produce lithium oxide (Li2O), which boils at 2800 K at 1 atm and hence at a lower temperature in vacuum. Fortunately, there exist many mixtures that release a lot of heat and form only condensed products during the combustion. Many such mixtures have been used for self-propagating high-temperature synthesis (SHS) of various materials [3, 4]. For the application discussed here, t itanium/boron (1:2 mole ratio) mixture appears to be particularly promising. The specific energy is 4.0 MJ/kg (1.1 kWh/kg), the adiabatic flame temperature is about 3200 K, and the reaction forms solid titanium diboride (TiB2, melting point: 3500 K). The mixture can be ignited easily with a heated tungsten wire, and it has been used widely as a booster to ignite the main mixture in the SHS process.Estimates: Assuming that specific heat of regolith is 500 J/(kg∙K) [5] and all generated heat is transferred to regolith, 12.5 kg of the Ti/B mixture would increase the temperature of 1000 kg of regolith by 100 K. To evaluate the rate of heat transfer in the regolith, a spherical model was analyzed where the heat released by a 12.5 kg Ti/B core propagates by thermal conduction through a 1000 kg regolith shell with no heat loss from its outer surface. At a bulk density of 1500 kg/m3 [5], the radius of the shell was 54 cm, while the radius of the core was about 11 cm. The calculations were conducted using Thermal Desktop SINDA/FLUINT (Cullimore and Ring Technologies) software at two constant values of bulk thermal conductivityk of the regolith: 0.001 and 0.01 W/(m∙K). The results show that after 14.5 days the core lost 31% of the released heat at the lower k and 77% at the higher k. At a distance of 20 cm from the core surface, the temperature of the regolith increased by only 1 K at the lower k and by 132 K at the higher k. In reality, the regolith near the heat source will be melted, so its thermal conductivity will increase significantly. Nevertheless, the conducted estimates indicate that combustion-based heat generators, placed directly in the regolith, could provide heat during a rather long period such as the lunar night.Conclusion: Heat generators based on gasless combustion of highly energetic reactive mixtures could be installed directly in the surface layer of lunar regolith. Because of the low thermal conductivity of the regolith, such generators would keep thermal energy for days and gradually supply heat to a rover/lander.Acknowledgment: The material presented in this work is based upon the work supported by National Aeronautics and Space Administration (NASA) under Grant #80NSSC20K0293.References: [1] Balasubramaniam R. et al. (2011) J. Thermophys. Heat Trans., 25,130−139. [2] Blair R.G. and Vasu S.S. (2022) Conf. Advanced Power Systems for Deep Space Exploration. [3] Varma A. et al. (1998) Adv. Chem. Eng., 24,79−226. [4] Levashov E.A. et al. (2017) Int. Mater. Rev., 62,203−239. [5] Wood-Robinson R. et al. (2019) J. Geophys. Res. Planets, 124, 1989−2011.

lunar↗

Universal Two-Phase Convection Heat Transfer Correlations for Cryogenic Pipe Chilldown

This paper presents a set of universal two-phase convection heat transfer correlations for modeling boiling heat transfer during pipe chilldown fit over the widest available range of cryogenic fluids and thermodynamic conditions. The correlations improve upon prior correlations that were developed separately for liquid nitrogen (LN2) and liquid hydrogen (LH2) pipe quenching datasets. The new correlations include equations to calculate the single-phase vapor heat transfer, film boiling heat transfer, transition boiling heat transfer, nucleate boiling heat transfer, single-phase liquid heat transfer, bulk vapor temperature during high quality film boiling, Leidenfrost temperature, critical heat flux, critical heat flux temperature, and the onset of nucleate boiling temperature. The correlations were validated against LH2, LN2, liquid methane, liquid oxygen, and liquid argon pipe quenching datasets. The eight datasets cover the following parameter ranges: pipe lengths of 0.1 to 6.5m; outer pipe diameters of 12.7 to 25.4 mm; pipe wall thicknesses from 0.51 to 1.64 mm; flow directions of upward, downward, and horizontal; gravity levels of 1g and 0g±0.01g. A numerical model assumes homogeneous mixing between the vapor and liquid and implicitly integrates the coupled energy equations for the pipe and fluid, as well as continuity for the fluid. The model was used to estimate the equilibrium quality and fluid mass accumulation along the pipes during chilldown from estimates of the fluid-pipe heat transfer extracted from temperature measurements. The correlations can be implemented in lumped parameter codes such as SINDA/FLUINT and the Generalized Fluid System Simulation Program (GFSSP) to improve the accuracy of chilldown time and chilldown boiloff mass predictions. Such predictions are useful for designing ground or in-space cryogenic liquid transfer systems.

Universal Correlations↗

Validation of Universal Cryogenic Flow Boiling Correlations in Thermal Desktop for Liquid Methane and Liquid Nitrogen

Future in-space cryogenic architectures will depend on the ability to accurately model various stages of cryogenic propellant transfer and storage. Currently there is a need for more accurate, direct cryogenic data-anchored models for various boiling phenomena. This paper presents the implementation and validation of recently developed universal cryogenic flow boiling correlations for saturated flow boiling heat transfer coefficients (HTC) and critical heat flux (CHF) into the Thermal Desktop (SINDA/FLUINT) modeling software. The correlations are validated against steady state cryogenic flow boiling historical heated tube cases from liquid nitrogen and liquid methane experiments covering a wide range of inlet conditions, mass flux, and heat flux. Overall, Thermal Desktop with the new universal cryogenic flow boiling correlations demonstrates significant improvement in predictive performance for both wall temperature and CHF location compared to the Thermal Desktop model with built-in correlations when both are compared to the data.

Mariano Mercado↗

Physics Based Model for Online Fault Detection in Autonomous Cryogenic Loading System

We report the progress in the development of the chilldown model for rapid cryogenic loading system developed at KSC. The nontrivial characteristic feature of the analyzed chilldown regime is its active control by dump valves. The two-phase flow model of the chilldown is approximated as one-dimensional homogeneous fluid flow with no slip condition for the interphase velocity. The model is built using commercial SINDAFLUINT software. The results of numerical predictions are in good agreement with the experimental time traces. The obtained results pave the way to the application of the SINDAFLUINT model as a verification tool for the design and algorithm development required for autonomous loading operation.

Cryogenics↗