Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SIGNAL DISTORTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

BOLAS: A Canadian-US Ionospheric Tether Mission

Everyday, international broadcasters, ships, and aircraft use a naturally conducting atmospheric layer, the ionosphere, to reflect communications signals over the Earth's horizon. A better understanding of this layer, with its irregularities, instabilities, and dynamics, would improve communications transmission and reception. This atmospheric layer is also a lens that can distort signal transmissions from communications, navigation, and surveillance satellites. The ionosphere over Canada and other high latitude countries can carry large currents and is particularly dynamic, so that a scientific understanding of this layer is critical. The BOLAS (Bistatic Observations using Low Altitude Satellites) mission would characterize reflective and transmissive properties of the ionosphere by flying two satellites, each with identical HF receivers, dipole antennas, particle probes, and GPS receivers. The satellites would be connected by a non-conducting tether to maintain a 100 m separation, and would cartwheel in the orbit plane to spatially survey the ionosphere. The six-month mission would fly in a high inclination, 350 x 600 km orbit, and would be active during passes over the auroral region of Canada. This paper discusses the system requirements and architecture, spacecraft and operations concepts, and mission design, as well as team organization, international cooperation and the scientific and technological benefits that are expected.

Tyc, George↗

Correction of complex nonlinear signal response from a pixel array detector

The pulsed free-electron laser light sources represent a new challenge to photon area detectors due to the intrinsic spontaneous X-ray photon generation process that makes single-pulse detection necessary. Intensity fluctuations up to 100% between individual pulses lead to high linearity requirements in order to distinguish small signal changes. In real detectors, signal distortions as a function of the intensity distribution on the entire detector can occur. Here a robust method to correct this nonlinear response in an area detector is presented for the case of exposures to similar signals. The method is tested for the case of diffuse scattering from liquids where relevant sub-1% signal changes appear on the same order as artifacts induced by the detector electronics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Advanced technology for a satellite multichannel demultiplexer/demodulator

Satellite on-board processing is needed to efficiently service multiple users while at the same time minimizing earth station complexity. The processing satellite receives a wideband uplink at 30 GHz and down-converts it to a suitable intermediate frequency. A multichannel demultiplexer then separates the composite signal into discrete channels. Each channel is then demodulated by bulk demodulators, with the baseband signals routed to the downlink processor for retransmission to the receiving earth stations. This type of processing circumvents many of the difficulties associated with traditional bent-pipe repeater satellites. Uplink signal distortion and interference are not retransmitted on the downlink. Downlink power can be allocated in accordance with user needs, independent of uplink transmissions. This allows the uplink users to employ different data rates as well as different modulation and coding schemes. In addition, all downlink users have a common frequency standard and symbol clock on the satellite, which is useful for network synchronization in time division multiple access schemes. The purpose of this program is to demonstrate the concept of an optically implemented multichannel demultiplexer (MCD). A proof-of-concept (POC) model has been developed which has the ability to receive a 40 MHz wide composite signal consisting of up to 1000 40 kHz QPSK modulated channels and perform the demultiplexing process. In addition a set of special test equipment (STE) has been configured to evaluate the performance of the POC model. The optical MCD is realized as an acousto-optic spectrum analyzer utilizing the capability of Bragg cells to perform the required channelization. These Bragg cells receive an optical input from a laser source and an RF input (the signal). The Bragg interaction causes optical output diffractions at angles proportional to the RF input frequency. These discrete diffractions are optically detected and output to individual demodulators for baseband conversion. Optimization of the MCD design was conducted in order to achieve a compromise between two opposing sources of signal degradation: adjacent channel interference and intersymbol interference. The system was also optimized to allow simple, inexpensive ground stations communications with the MCD. These design goals led to the realization of a POC MCD which demonstrates the demultiplexing function with minimal signal degradation. Performance evaluation results using the STE equipment indicate that the dynamic range of the demultiplexer in the presence of adjacent and multiple channel loading is 40 - 50 dB. Measured bit error rate (BER) probabilities varied from the predicted theoretical results by one dB or less. The performance of the proof-of-concept model indicate that the development of a space qualified optically implemented MCD are feasible. The advantages to such an implementation include reduced size, weight and power and increased reliability when compared with electronic approaches. All of these factors are critical to on-board satellite processors. Further optimization can be conducted which trade ground station complexity and MCD performance to achieve desired system results.

Abramovitz, Irwin J.↗

Blinding scheme for the scale-dependence bias signature of local primordial non-Gaussianity for DESI 2024

The next generation of spectroscopic surveys is expected to achieve an unprecedented level of accuracy in the measurement of cosmological parameters. To avoid confirmation bias and thereby improve the reliability of these results, blinding procedures become a standard practice in the cosmological analyses of such surveys. Blinding is especially crucial when the impact of observational systematics is important relative to the cosmological signal, and a detection of that signal would have significant implications. This is the case for local primordial non-gaussianity, as probed by the scale-dependent bias of the galaxy power spectrum at large scales that are heavily sensitive to the dependence of the target selection on the imaging quality, known as imaging systematics. We propose a blinding method for the scale-dependent bias signature of local primordial non-gaussianity at the density field level which consists in generating a set of weights for the data that replicate the scale-dependent bias. The applied blinding is predictable, and can be straightforwardly combined with other catalog-level blinding procedures that have been designed for the baryon acoustic oscillation and redshift space distortion signals. The procedure is validated through simulations that replicate data from the first year of observation of the Dark Energy Spectroscopic Instrument, but may find applications to other upcoming spectroscopic surveys.

79 ASTRONOMY AND ASTROPHYSICS↗

xEMU Suit Integrated Audio Communications System: Ambient and EVA Pressure Testing System Performance

Testing across several airlock and EVA thermal and pressure scenarios has demonstrated that the Integrated Audio System of NASA’s Exploration Extravehicular Mobility Unit (xEMU) spacesuits transmits and receives intelligible audio communications without the use of a commcap or similar worn device. The xEMU audio system consists of internal loudspeakers and digital microphones (Integrated Communications System –ICS) combined with an adaptive Acoustic Echo Canceller (AEC), outbound voice operated transmission (VOX), and automatic gain control (AGC). Transducers are mounted in an “exploded commcap” configuration with helmet-attached speakers near the ears and three microphones positioned at the collar. The AGC removes inbound audio signals (e.g.,suit, Mission Control, Lander, C&W tones) from the outbound comms stream, reducing echo and feedback (squeal) in low-noise suit environments. The reduction of worn communication equipment increases crewmember comfort, range of movement, and situational awareness. However, test results also highlight the need for proper fan, duct, pump, and gas flow integration with suit acoustics and audio. Ductwork may serve as waveguides for various component and structure-borne noise. Sharply angled ducts can generate turbulent-flow noise. Gas flow from inlets above the crewmember’s head can generate noise when cascading over the faceplate and collar (or commcap) microphones. Sufficient acoustic noise levels (1) require increased gain to boost inbound audio, and (2) may distort signals resulting in AEC disruption or artifacts. Suit-noise levels decline with reduced pressure (density), but then elevated speech and audio effort/power become necessary. Whether the Integrated Audio System, commcap, or other device is used, suit acoustic noise can mask speech in outbound comms. This reduces intelligibility and requires other AECs/devices to suppress comms noise. Yet, adjusting a few components may yield significant improvement. We discuss xEMU audio functionality, demonstrate how acoustical treatment combined with inbound signal conditioning improved clarity during tests, and discuss future modifications.

xEMU↗

xEMU Suit Integrated Audio Communications System: Ambient and EVA Pressure Testing System Performance

Testing across several airlock and EVA thermal and pressure scenarios has demonstrated that the Integrated Audio System of NASA’s Exploration Extravehicular Mobility Unit (xEMU) spacesuits transmits and receives intelligible audio communications without the use of a commcap or similar worn device. The xEMU audio system consists of internal loudspeakers and digital microphones (Integrated Communications System –ICS) combined with an adaptive Acoustic Echo Canceller (AEC), outbound voice operated transmission (VOX), and automatic gain control (AGC). Transducers are mounted in an “exploded commcap” configuration with helmet-attached speakers near the ears and three microphones positioned at the collar. The AGC removes inbound audio signals (e.g.,suit, Mission Control, Lander, C&W tones) from the outbound comms stream, reducing echo and feedback (squeal) in low-noise suit environments. The reduction of worn communication equipment increases crewmember comfort, range of movement, and situational awareness. However, test results also highlight the need for proper fan, duct, pump, and gas flow integration with suit acoustics and audio. Ductwork may serve as waveguides for various component and structure-borne noise. Sharply angled ducts can generate turbulent-flow noise. Gas flow from inlets above the crewmember’s head can generate noise when cascading over the faceplate and collar (or commcap) microphones. Sufficient acoustic noise levels (1) require increased gain to boost inbound audio, and (2) may distort signals resulting in AEC disruption or artifacts. Suit-noise levels decline with reduced pressure (density), but then elevated speech and audio effort/power become necessary. Whether the Integrated Audio System, commcap, or other device is used, suit acoustic noise can mask speech in outbound comms. This reduces intelligibility and requires other AECs/devices to suppress comms noise. Yet, adjusting a few components may yield significant improvement. We discuss xEMU audio functionality, demonstrate how acoustical treatment combined with inbound signal conditioning improved clarity during tests, and discuss future modifications.

xEMU↗

Subaru weak-lensing survey of dark matter subhalos in the Coma cluster: Subhalo mass function and statistical properties

We present a 4 deg{sup 2} weak gravitational lensing survey of subhalos in the very nearby Coma cluster using the Subaru/Suprime-Cam. The large apparent size of cluster subhalos allows us to measure the mass of 32 subhalos detected in a model-independent manner, down to the order of 10{sup –3} of the virial mass of the cluster. Weak-lensing mass measurements of these shear-selected subhalos enable us to investigate subhalo properties and the correlation between subhalo masses and galaxy luminosities for the first time. The mean distortion profiles stacked over subhalos show a sharply truncated feature which is well-fitted by a Navarro-Frenk-White (NFW) mass model with the truncation radius, as expected due to tidal destruction by the main cluster. We also found that subhalo masses, truncation radii, and mass-to-light ratios decrease toward the cluster center. The subhalo mass function, dn/dln M {sub sub}, in the range of 2 orders of magnitude in mass, is well described by a single power law or a Schechter function. Best-fit power indices of 1.09{sub −0.32}{sup +0.42} for the former model and 0.99{sub −0.23}{sup +0.34} for the latter, are in remarkable agreement with slopes of ∼0.9-1.0 predicted by the cold dark matter paradigm. The tangential distortion signals in the radial range of 0.02-2 h {sup –1} Mpc from the cluster center show a complex structure which is well described by a composition of three mass components of subhalos, the NFW mass distribution as a smooth component of the main cluster, and a lensing model from a large scale structure behind the cluster. Although the lensing signals are 1 order of magnitude lower than those for clusters at z ∼ 0.2, the total signal-to-noise ratio, S/N = 13.3, is comparable, or higher, because the enormous number of background source galaxies compensates for the low lensing efficiency of the nearby cluster.

79 ASTRONOMY AND ASTROPHYSICS↗

The clustering of galaxies in the SDSS-III Baryon Oscillation Spectroscopic Survey: RSD measurement from the LOS-dependent power spectrum of DR12 BOSS galaxies

We measure and analyse the clustering of the Baryon Oscillation Spectroscopic Survey (BOSS) relative to the line-of-sight (LOS), for LOWZ and CMASS galaxy samples drawn from the final Data Release 12 (DR12). The LOWZ sample contains 361\,762 galaxies with an effective redshift of $z_{\rm lowz}=0.32$, and the CMASS sample 777\,202 galaxies with an effective redshift of $z_{\rm cmass}=0.57$. From the power spectrum monopole and quadrupole moments around the LOS, we measure the growth of structure parameter $f$ times the amplitude of dark matter density fluctuations $\sigma_8$ by modeling the Redshift-Space Distortion signal. When the geometrical Alcock-Paczynski effect is also constrained from the same data, we find joint constraints on $f\sigma_8$, the product of the Hubble constant and the comoving sound horizon at the baryon drag epoch $H(z)r_s(z_d)$, and the angular distance parameter divided by the sound horizon $D_A(z)/r_s(z_d)$. We find $f(z_{\rm lowz})\sigma_8(z_{\rm lowz})=0.394\pm0.062$, $D_A(z_{\rm lowz})/r_s(z_d)=6.35\pm0.19$, $H(z_{\rm lowz})r_s(z_d)=(11.41\pm 0.56)\,{10^3\rm km}s^{-1}$ for the LOWZ sample, and $f(z_{\rm cmass})\sigma_8(z_{\rm cmass})=0.444\pm0.038$, $D_A(z_{\rm cmass})/r_s(z_d)=9.42\pm0.15$, $H(z_{\rm cmass})r_s(z_d)=(13.92 \pm 0.44)\, {10^3\rm km}s^{-1}$ for the CMASS sample. We find general agreement with previous BOSS DR11 measurements. Assuming the Hubble parameter and angular distance parameter are fixed at fiducial $\Lambda$CDM values, we find $f(z_{\rm lowz})\sigma_8(z_{\rm lowz})=0.485\pm0.044$ and $f(z_{\rm cmass})\sigma_8(z_{\rm cmass})=0.436\pm0.022$ for the LOWZ and CMASS samples, respectively.

79 ASTRONOMY AND ASTROPHYSICS↗

Dealing with Definitional Uncertainty: Better Measurements in Power Systems

Abstract—There is a relationship between the user of the result of a measurement and the act of measurement that should guide the act: the user has some specific need for the meaning contained in the result. The extent to which that need is met is a measure of the quality of the measurement. The usual metric is an uncertainty statement. This paper shows that, because of significant signal distortion, the uncertainty statement may be inappropriate outside the calibration laboratory. We propose a way to improve the situation. Better measurements are not necessarily ones with faster response or greater precision: the important point is that they meet the needs of the user. They are “fit for purpose.” The solution proposed here affects both the instrument designer and the user. It requires that additional information regarding uncertainty accompany all result values (not just those done in the calibration laboratory), and it requires changes to the way the results are handled by the user. The paper concentrates on the electric power system, but it is hoped that the ideas can be applied more broadly to field measurements.

measurement theory, Uncertainity, definitional unc↗

Vibrational Spectroscopic Monitoring of the Gelation Transition in Nafion Ionomer Dispersions

Infrared and Raman spectroscopy techniques were applied to investigate the drying and aggregation behavior of Nafion ionomer particles dispersed in aqueous solution. Gravimetric measurements aided the identification of gel-phase development within a series of time-resolved spectra that tracked transformations of a dispersion sample during solvent evaporation. A spectral band characteristic of ionomer sidechain end group vibration provided a quantitative probe of the dispersion-to-gel change. For sets of attenuated total reflection Fourier transform infrared (ATR FT-IR) spectra, adherence to Beer's law was attributed to the relatively constant refractive index in the frequency region of hydrated –SO$^{–}_{3}$ group vibrations as fluorocarbon-rich ionomer regions aggregate in forming the structural framework of membranes and thin films. Although vibrational bands associated with ionomer backbone CF 2 stretching vibrations were affected by distortion characteristic of wavelength-dependent refractive index change within a sample, the onset of band distortion signaled gel formation and coincided with ionomer mass % values just below the critical gelation point for Nafion aqueous dispersions. Similar temporal behavior was observed in confocal Raman microscopy experiments that monitored the formation of a thin ionomer film from an individual dispersion droplet. For the ATR FT-IR spectroscopy and confocal Raman microscopy techniques, intensity in the water H–O–H bending vibrational band dropped sharply at the ionomer critical gelation point and displayed a time dependence consistent with changes in water content derived from gravimetric measurements. The reported studies lay groundwork for examining the impact of dispersing solvents and above-ambient temperatures on fluorinated ionomer transformations that influence structural properties of dispersion-cast membranes and thin films.

36 MATERIALS SCIENCE↗

A high-temperature Rutherford Backscattering Spectrometry apparatus for in situ material characterization

A new methodology for high-temperature Rutherford Backscattering Spectrometry (HT-RBS) has been developed to enable in situ material characterization at elevated temperatures. A 3.5 MeV proton beam penetrates a 10-µm-thick 316L stainless steel foil mounted on a graphite substrate, with backscattered signals detected using an HT-RBS system. Conventional semiconductor detectors, primarily based on silicon, suffer significant performance degradation at temperatures higher than ~ 60 °C due to increased leakage current and noise, leading to signal distortion and failure. Here, to preserve spectral quality, a 5 µm aluminum foil shields the detector from thermal radiation, allowing reliable operation up to 900 °C at the target. A rotatable shutter provides additional thermal isolation during data collection pauses. In situ measurements of areal density changes of 316L stainless steel were conducted to validate the technique, revealing consistency with the known thermal expansion coefficient. The method facilitates seamless switching between irradiation and analysis, enabling continuous studies. This approach supports in situ investigations of diffusion, void swelling, creep, and corrosion, offering a versatile tool for advanced materials research.

36 MATERIALS SCIENCE↗

Photon-to-Digital Converters for Neutron Imaging Instruments (Final Report)

Oak Ridge National Laboratory (ORNL) collaborated with the Université de Sherbrooke (UdeS) to design a modular and scalable tile of innovative digital photodetectors called Photon-to-Digital Converters (PDC) and the required subsystems to demonstrate the feasibility of large area single-photon detectors to support high-resolution, depth-of-interaction, fast neutron radiography based on scintillation detectors. The goal is to demonstrate the advantages of using PDC over conventional Silicon Photomultiplier (SiPM) for neutron imaging systems. The basic building blocks of analog SiPM and PDC are Single-Photon Avalanche Photodiodes (SPAD). The main difference between conventional SiPMs and PDCs, is in the fact that analog SiPMs sum the charge produced by individual SPAD passively, while in PDCs each SPAD is read out individually by an active electronic circuit. Hence, PDCs provide a direct photon-to-bit conversion where a logic “1” means that there was a detection in a given SPAD. Conversely, an analog SiPM requires a sophisticated preamplifier (current amplifiers or transimpedance amplifier) followed by a shaping amplifier and an analog-to-digital converter. Moreover, since the charge from each SPAD varies slightly, the passive sum of the analog SiPM will have signal fluctuations for the same amount of photon detected. This is one of many issues that is completely eliminated by individual one-to-one SPAD read out in PDCs. The large area required for scintillator readouts for neutron imaging is such that the output capacitance of a large area of SiPM arrays is very high. This creates a burden on the signal-to-noise optimization with respect to the power budget. For PDC, the power consumption is dictated by rate of the incident photon flux, or in photon-starved environments, the dark noise rate of the SPAD array. In other words, the power consumption in the absence of events is extremely low. Hence, the power consumption of a PDC read out system is much lower than its analog counterpart. Further, the large SiPM capacitance may introduce signal distortions on the scintillator fast rise or decay time with undesired effects on timing and pulse shape discrimination. The problem is absent in PDCs, as their readout is independent on device capacitance. UdeS is the world leader in 3D vertical integration of frontside illuminated SPAD arrays over CMOS readouts. These capabilities allow future production of “3D PDC” with maximum photosensitive fill factor and electronic functionalities tailored to the application. UdeS' vast knowledge of SPADs and CMOS design made the team an ideal collaborator in the development of large area high-resolution fast neutron radiography.

42 ENGINEERING↗

Operating frequencies for educational satellite services

The factors affecting the choice of transmission frequencies are identified. These include international radio regulations, natural environment, man-made environment, hardware considerations, and interconnection and spectrum space considerations. An analysis is presented of international radio regulations with emphasis on 1963 EARC and 1971 WARC frequency allocations, powerflux density restrictions, and resolutions concerning introduction of broadcasting-satellite systems. Natural-environmental effects were divided into two categories: (1) those due to transionospheric propagation, and (2) those that can be credited to the earth's atmosphere and its constituents. The frequency dependence of the signal attenuation, signal distortion, and contributions to system noise temperature due to environmental effects are discussed, and comparisons were made for frequencies of interest. Man-made environmental effects were examined in terms of various sharing limitations as well as the indigenous noise contribution to the overall system noise.

Singh, J. P.↗

Pyrotechnic shock measurement and data analysis requirements

A study of laboratory measurement and analysis of pyrotechnic shock prompted by a discrepancy in preliminary Mariner Jupiter/Saturn shock test data is reported. It is shown that before generating shock response plots from any recorded pyrotechnic event, a complete review of each instrumentation and analysis system must be made. In addition, the frequency response capability of the tape recorder used should be as high as possible; the discrepancies in the above data were due to inadequate frequency response in the FM tape recorders. The slew rate of all conditioning amplifiers and input converters must be high enough to prevent signal distortion at maximum input voltage; amplifier ranges should be selected so that the input pulse is approximately 50% of full scale; the Bessel response type should be chosen for digital shock analysis if antialiasing filters are employed; and transducer selection must consider maximum acceleration limit, mounted resonance frequency, flat clean mounting surfaces, base bending sensitivity, and proper torque.

Albers, L.↗

Analytical simulation of nonlinear satellite links

It is noted that performance predictions for nonlinear digital satellite channels are usually obtained by either purely analytical methods or Monte Carlo simulations. When used with other than very simple channel models, however, they become extremely costly. It is shown that, through analytical modeling of the effect of the nonlinearity on the uplink waveform, it is possible to obtain approximate performance predictions with a minimum of computer time. It is also demonstrated that the results agree quite well with Monte Carlo simulations and that significant trade-offs can be performed with this tool. An analytical simulation based on Blachman's (1968) definition of signal x signal, signal x noise, and noise x noise terms is shown to provide the required flexibility for modeling the effect of signal distortions on the link performance and to produce good results over a wide range of nonlinearities and channel conditions.

Braun, W. R.↗

On the dynamic response of pressure transmission lines in the research of helium-charged free piston Stirling engines

The signal distortion inherent to pressure transmission lines in free-piston Stirling engine research is discussed. Based on results from classical analysis, guidelines are formulated to describe the dynamic response properties of a volume-terminated transmission tube for applications involving the helium-charged free-piston Stirling engines. The underdamped flow regime is described, the primary resonance frequency is derived, and the pressure phase and amplitude distortion are discussed. The scope and limitation of the dynamic response analysis are considered.

Miller, Eric L.↗

High-efficiency 20 GHz traveling wave tube development for space communications

A 75 watt CW high efficiency helix TWT operating at 20 GHz was developed for satellite communication systems. The purpose was to extend the performance capabilities of helix TWTs by using recent technology developments. The TWT described is a unique design because high overall efficiency is obtained with a low perveance beam. In the past, low perveance designs resulted in low beam efficiencies. However, due to recent breakthoughs in diamond rod technology and in collector electrode materials, high efficiencies can now be achieved with low perveance beams. The advantage of a low perveance beam is a reduction in space charge within the beam which translates to more efficient collector operation. In addition, this design incorporates textured graphite electrodes which further enhance collector operation by suppressing backstreaming secondaries. The diamond supported helix circuit features low RF losses, high interaction impedance, good thermal handling capability and has been designed to compensate for the low perveance beam. One more discussed tube feature is the use of a velocity taper in the output helix that achieves low signal distortion while maintaining high efficiency.

Aldana, S. L.↗