Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SF6”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

47 records · Page 3

Constraining Bedrock Groundwater Residence Times in a Mountain System with Environmental Tracer Observations and Bayesian Uncertainty Quantification: Modeling and Data Package

Groundwater residence times provide fundamental descriptions of hydrologic dynamics and mixing processes in mountainous watersheds. Yet, few observational datasets that can constrain groundwater residence times over broad timescales are available in high elevation mountain systems. Here we present field observations from May 2021 of dissolved noble gases (He, Ne, Ar, Kr, and Xe), Chloroflourcarbons (CFCs), Sulfurhexaflouride (SF6), and tritium (3H) sampled from the Pumphouse Lower Montane study site (wells PLM1, PLM6, and PLM7) within the East River Watershed, Colorado. The presented noble gas (PLM_noblegas_2021.csv) and environmental tracer (PLM_tracers_2021.csv) observation datasets, along with the associated modeling scripts, aide in quantifying groundwater residence times and recharge conditions in a high elevation mountain system. Furthermore, the modeling scripts quantify groundwater residence time and noble gas recharge condition uncertainties using a novel Markov-chain Monte Carlo approach. All data modeling scripts are written in the Python code.

54 ENVIRONMENTAL SCIENCES↗

A 500 KV INVERTED GEOEMTRY FEEDTHROUGH FOR A HIGH VOLT-AGE DC ELECTRON GUN

The Continuous Electron Beam Accelerator Facility injector at Jefferson Lab (JLab) utilizes an inverted-geometry ceramic insulator photogun operating at 130 kV direct current to generate spin-polarized electron beams for high-energy nuclear physics experiments. A second photogun delivers 180 keV beam for commissioning a SRF booster in a testbed accelerator, and a larger version delivers 300 keV magnetized beam in a test stand beam line. This contribution reports on the development of an unprecedented inverted-insulator with cable connector for reliably applying 500 kV DC to a future polarized beam photogun, to be designed for operating at 350 kV without field emission. Such a photogun design could then be used for generating a polarized electron beam to drive a spin-polarized positron source as a demonstrator for high energy nuclear physics at JLab. There are no commercial cable connectors that fit the large inverted insulators required for that voltage range. Our proposed concept is based on a modified epoxy receptacle with intervening SF6 layer and a test electrode in a vacuum vessel.

Hernandez-Garcia, C.↗

UNESE Data Analysis - Disko Elm Gas Transport Characteristics (NA-22 Quarterly Report)

Two research papers describing gas transport studies in subsurface containment environments appropriate for underground nuclear explosions were revised and accepted for publication in the peer-reviewed journals, Nature – Scientific Reports and Journal of Geophysical Research. The Nature – Scientific Reports paper is a primary deliverable and describes the gas-transport experiment performed in P Tunnel (NNSS) and 1) subsequent analysis of field data as part of the UNESE program. The Journal of Geophysical Research paper describes an experiment, supported mainly by DARPA and led by researchers at Weston Geophysical and New Mexico Tech., with 2) analyses supported by this project to evaluate the ability of SF6 gas tracer to track xenon gas migration under conditions related to a previous UNESE experiment. Two new tasks consider 3) evaluation of detonation heating and multiphase flow on arrival of xenon at the surface and 4) the impact of surface or Langmuir adsorption of gases being transported through pores and along fractures.

58 GEOSCIENCES↗

1MV Febetron Pulse Generator Operator's Manual

The Febetron Pulse Generator (FPG) is an experimental assembly used to store electrical energy for a period of time and then release that energy over a short duration pulse to achieve high instantaneous power outputs. The FPG is an ideal device to be used for a variety high energy physics experiments. For mobility and ease of repeatable operation, the FPG is secured on a rolling test fixture and paired with a diagnostic and controls rack. The combination of the FPG, test fixture cart, SF6 gas cart, and controls rack is identified as the Pulse Generator Testing Assembly (PGTA). This document outlines all necessary information regarding the working principles, assembly/disassembly, maintenance, operation, uses, hazards, and experimental procedures of the 1 Mega Volt (MV) PGTA. This document, in addition to the manufacturer’s manuals, should be utilized as a reference whenever working with the PGTA and any of its components.

42 ENGINEERING↗

A 500 KV INVERTED GEOEMTRY FEEDTHROUGH FOR A HIGH VOLT-AGE DC ELECTRON GUN

This contribution reports on the development of an unprecedented inverted-insulator with cable connector for reliably applying 500 kV dc to a future polarized beam photogun, to be designed for operating at 350kV without field emission. Such a photogun design could then be used for generating a polarized electron beam to drive a spin-polarized positron source as a demonstrator for high energy nuclear physics at JLab. There are no commercial cable connectors that fit the large inverted insulators required for that voltage range. Our proposed concept is based on a modified epoxy receptacle with intervening SF6 layer and a test electrode in a vacuum vessel.

Hernandez-Garcia, C.↗

Avalanche gain and its effect on energy resolution in GEM-based detectors

Here, we present avalanche gain and associated resolution measurements recorded with a 4 He:CO 2 (70:30) gas mixture and pure SF 6 , a Negative Ion (NI) gas. SF 6 is of particular interest to the directional dark matter detection community, as its low thermal diffusion helps to retain recoil ionization track features over long drift lengths. With the aid of a general form of the reduced first Townsend coefficient (RFTC), multiple GEM-based detector data sets are used to study the high-gain behavior of the 4 He:CO 2 gas mixture. The high-gain data is well described purely in terms of the reduced electric field strength and the number of GEMs, and the robust relationship between the RFTC and the average, reduced, electric field strength across the GEMs is emphasized. The associated (pulse-height) resolution measurements are used to discuss the variance of the avalanche distribution and to describe and estimate the lower limits of energy resolution one should expect to measure using a simple relationship with the RFTC. In the end, a description of avalanche gain, its effect on energy resolution, and the contributing experimental parameters in GEM-based detectors is developed over a broad parameter space for further use.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

In-situ measurements of chemically and radiatively important atmospheric gases from the Advanced Global Atmospheric Gas Experiment (AGAGE) and affiliated stations.

In the ALE/GAGE/AGAGE global network program, continuous high frequency gas chromatographic measurements of four biogenic/anthropogenic gases (methane, CH4; nitrous oxide, N2O; hydrogen, H2; and carbon monoxide, CO) and several anthropogenic gases that contribute to stratospheric ozone destruction and/or to the greenhouse effect have been carried out at five globally distributed sites for several years. The program, which began in 1978, is divided into three parts associated with three changes in instrumentation: the Atmospheric Lifetime Experiment (ALE), which used Hewlett Packard HP5840 gas chromatographs; the Global Atmospheric Gases Experiment (GAGE), which used HP5880 gas chromatographs; and the present Advanced GAGE (AGAGE). AGAGE uses two types of instruments: a gas chromatograph with multiple detectors (GC-MD), and a gas chromatograph with mass spectrometric analysis (GC-MS). Beginning in January 2004, an improved cryogenic preconcentration system (Medusa) replaced the absorption-desorption module in the GC-MS systems at Mace Head and Cape Grim; this provided improved capability to measure a broader range of volatile perfluorocarbons with high global warming potentials. The Medusa GC-MS systems were subsequently used at other AGAGE stations (Trinidad Head, Barbados, American Samoa, Zeppelin, Jungfraujoch, and Goan) after the initial setup at Mace Head and Cape Grim. More information may be found at the AGAGE home page: https://agage.mit.edu/instruments.Compared to the previous version (https://data.ess-dive.lbl.gov/view/doi:10.3334/CDIAC/ATG.DB1001), the latest update (Agage_gcmd_gcms_data_2021_04_07_tar.gz) includes 6 months of new data through the end of March 2020. Two new compounds, HCFC-132b, and HCFC-133a, are also included in this version. For a complete list of released compounds and used standard scales, please see “AGAGE_scale_2021_v1.pdf” file. Additional information can also be found on the AGAGE website (https://agage.mit.edu).

54 ENVIRONMENTAL SCIENCES↗

The Advanced Global Atmospheric Gases Experiment (AGAGE) Data

In the ALE/GAGE/AGAGE global network program, continuous high frequency gas chromatographic measurements of four biogenic/anthropogenic gases (methane, CH4; nitrous oxide, N2O; hydrogen, H2; and carbon monoxide, CO) and several anthropogenic gases that contribute to stratospheric ozone destruction and/or to the greenhouse effect have been carried out at five globally distributed sites for several years. The program, which began in 1978, is divided into three parts associated with three changes in instrumentation: the Atmospheric Lifetime Experiment (ALE), which used Hewlett Packard HP5840 gas chromatographs; the Global Atmospheric Gases Experiment (GAGE), which used HP5880 gas chromatographs; and the present Advanced GAGE (AGAGE). AGAGE uses two types of instruments: a gas chromatograph with multiple detectors (GC-MD), and a gas chromatograph with mass spectrometric analysis (GC-MS). Beginning in January 2004, an improved cryogenic preconcentration system (Medusa) replaced the absorption-desorption module in the GC-MS systems at Mace Head and Cape Grim; this provided improved capability to measure a broader range of volatile perfluorocarbons with high global warming potentials. The Medusa GC-MS systems were subsequently used at other AGAGE stations (Trinidad Head, Barbados, American Samoa, Zeppelin, Jungfraujoch, and Goan) after the initial setup at Mace Head and Cape Grim. More information may be found at the AGAGE home page: https://agage.mit.edu/instruments.Compared to the previous version (https://data.ess-dive.lbl.gov/datasets/doi: doi:10.15485/1781803), the latest update (Agage_gcmd_gcms.data.2022_01_03.tar.gz) includes 6 months of new data through the end of September 2020. For a complete list of released compounds and used standard scales, please see “AGAGE_scale_2021_v1.pdf” file. Additional information can also be found on the AGAGE website (https://agage.mit.edu).

54 ENVIRONMENTAL SCIENCES↗

The dataset of in-situ measurements of chemically and radiatively important atmospheric gases from the Advanced Global Atmospheric Gas Experiment (AGAGE) and affiliated stations (2023R2)

In the ALE/GAGE/AGAGE global network program, continuous high frequency gas chromatographic measurements of four biogenic/anthropogenic gases (methane, CH4; nitrous oxide, N2O; hydrogen, H2; and carbon monoxide, CO) and several anthropogenic gases that contribute to stratospheric ozone destruction and/or to the greenhouse effect have been carried out at five globally distributed sites for several years. The program, which began in 1978, is divided into three parts associated with three changes in instrumentation: the Atmospheric Lifetime Experiment (ALE), which used Hewlett Packard HP5840 gas chromatographs; the Global Atmospheric Gases Experiment (GAGE), which used HP5880 gas chromatographs; and the present Advanced GAGE (AGAGE). AGAGE uses two types of instruments: a gas chromatograph with multiple detectors (GC-MD), and a gas chromatograph with mass spectrometric analysis (GC-MS). Beginning in January 2004, an improved cryogenic preconcentration system (Medusa) replaced the absorption-desorption module in the GC-MS systems at Mace Head and Cape Grim; this provided improved capability to measure a broader range of volatile perfluorocarbons with high global warming potentials. The Medusa GC-MS systems were subsequently used at other AGAGE stations (Trinidad Head, Barbados, American Samoa, Zeppelin, Jungfraujoch, and Goan) after the initial setup at Mace Head and Cape Grim. More information may be found on the AGAGE home page: https://agage.mit.edu/instruments.Data from the AGAGE and affiliated stations (total of 10 sites) between August 1993 and December 2022 are provided in “Agage_gcmd_gcms_data_2023_11_15.tar.gz” (compressed tar file). The metadata file has information on each station and currently released species. The standard scales used in archived species are listed in "AGAGE_scale_2023_v2.pdf". Additional information can be found on the AGAGE website (https://agage.mit.edu).

54 ENVIRONMENTAL SCIENCES↗

The dataset of in-situ measurements of chemically and radiatively important atmospheric gases from the Advanced Global Atmospheric Gas Experiment (AGAGE) and affiliated stations (2024R1)

In the ALE/GAGE/AGAGE global network program, continuous high frequency gas chromatographic measurements of four biogenic/anthropogenic gases (methane, CH4; nitrous oxide, N2O; hydrogen, H2; and carbon monoxide, CO) and several anthropogenic gases that contribute to stratospheric ozone destruction and/or to the greenhouse effect have been carried out at five globally distributed sites for several years. The program, which began in 1978, is divided into three parts associated with three changes in instrumentation: the Atmospheric Lifetime Experiment (ALE), which used Hewlett Packard HP5840 gas chromatographs; the Global Atmospheric Gases Experiment (GAGE), which used HP5880 gas chromatographs; and the present Advanced GAGE (AGAGE). AGAGE uses two types of instruments: a gas chromatograph with multiple detectors (GC-MD), and a gas chromatograph with mass spectrometric analysis (GC-MS). Beginning in January 2004, an improved cryogenic preconcentration system (Medusa) replaced the absorption-desorption module in the GC-MS systems at Mace Head and Cape Grim; this provided improved capability to measure a broader range of volatile perfluorocarbons with high global warming potentials. The Medusa GC-MS systems were subsequently used at other AGAGE stations (Trinidad Head, Barbados, American Samoa, Zeppelin, Jungfraujoch, and Goan) after the initial setup at Mace Head and Cape Grim. More information may be found on the AGAGE home page: https://agage.mit.edu/instruments.Data from the AGAGE and affiliated stations (total of 10 sites) between August 1993 and June 2023 are provided in “Agage_gcmd_gcms_data_2024_07_11.tar.gz” (compressed tar file). The metadata file has information on each station and currently released species. The standard scales used in archived species are listed in "AGAGE_scale_2024_v1.pdf". Additional information can be found on the AGAGE website (https://agage.mit.edu).Update: Dec. 4, 20241. The Cape Grim H2_PDD data are updated in this release ((H2_PDD values in previous release are wrong due to coding error). All other data in this release are the same as previous version ("Agage_gcmd_gcms.data.2024_07_11.tar.gz")2. The latest data are saved in "Agage_gcmd_gcms.data.2024_12_04.tar.gz"

54 ENVIRONMENTAL SCIENCES↗

Nanosecond Breakdown Characteristics of C 4 F 7 N and Various Mixtures at Pressures Above 1 Atmosphere in Comparison with SF 6

This report evaluates the pulsed breakdown performance of C 4 F 7 N under a 6.8 kV/ns voltage excitation. The pulsed dielectric strength of C 4 F 7 N is compared to SF 6 in the same experimental setup, and it is found that C 4 F 7 N concentrations of 50% or greater are required to achieve a dielectric strength greater than or equal to SF 6 . Pure C 4 F 7 N demonstrated higher electric field hold-off for longer time periods and less statistical variance under pulsed conditions when compared to SF 6 . Mixtures of 50%C 4 F 7 N with N 2 or CO 2 as buffer gases showed no appreciable difference in pulsed dielectric strength.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗