Metrics for the National SCADA Test Bed Program

The U.S. Department of Energy Office of Electricity Delivery and Energy Reliability (DOE-OE) National SCADA Test Bed (NSTB) Program is providing valuable inputs into the electric industry by performing topical research and development (R&D) to secure next generation and legacy control systems. In addition, the program conducts vulnerability and risk analysis, develops tools, and performs industry liaison, outreach and awareness activities. These activities will enhance the secure and reliable delivery of energy for the United States. This report will describe metrics that could be utilized to provide feedback to help enhance the effectiveness of the NSTB Program.

24 POWER TRANSMISSION AND DISTRIBUTION↗

VAC: A Software Approach to Resilient SCADA Automation

To better secure critical infrastructure, especially power systems, this paper introduces a virtual SCADA automation controller. The automation controller is a gateway into a power subsystem, making it a valuable target for cyber-attacks that could cut it off from the control center and cause a loss of view and control. To prevent this, the Virtual Automation Controller (VAC) is a backup device that mirrors the capabilities of the physical controller. It can communicate via Modbus and DNP3 and is containerized so it can be deployed on a variety of platforms. Furthermore, it utilizes software-defined networking to quickly disconnect a failed automation controller and preserve its state for forensics. The VAC gives system operators time to replace the failed controller and prevents dangerous and costly damage to power systems. The VAC is compared against the SEL 3505-3 RTAC and shown to have the necessary features to act as a failover controller.

Johnson, Jordan↗

FLASC (FLORIS-based Analysis for SCADA data)

FLASC provides a rich suite of analysis tools for SCADA data filtering & analysis, wind farm model validation, field experiment design, and field experiment monitoring. The repository is centrally built around NRELs in-house floris wind farm model, available at https://github.com/nrel/floris. FLASC also largely relies on the energy ratio to, among others, quantify wake losses in synthetic and historical data, to perform turbine northing calibrations, and for model parameter estimation.

Fleming, Paul↗

Siemens-INL SCADA System Assessments: Assessment 1: Spectrum Power TG & Assessment 2: Spectrum Power 3 (Final CRADA Report)

INL, in collaboration with Siemens Energy, Inc., performed a laboratory assessment on Siemens SCADA systems. During the assessment, vulnerabilities were discovered, evaluated, and mitigation strategies recommended. These results were reported to Siemens Energy, Inc. to guide their efforts towards improved cyber security in their software products.

97 MATHEMATICS AND COMPUTING↗

Production Facility SCADA Design Report

The following report covers FY 14 activities to develop supervisory control and data acquisition (SCADA) system for the Northstar Moly99 production facility. The goal of this effort is to provide Northstar with a baseline system design.

42 ENGINEERING↗

Multiple Flow Loop SCADA System Implemented on the Production Prototype Loop

The following report covers FY 15 activities to develop supervisory control and data acquisition (SCADA) system for the Northstar Moly99 production prototype gas flow loop. The goal of this effort is to expand the existing system to include a second flow loop with a larger production-sized blower. Besides testing the larger blower, this system will demonstrate the scalability of our solution to multiple flow loops.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Validation of FAST.Farm Against Full-Scale Turbine SCADA Data for a Small Wind Farm

FAST.Farm is a new midfidelity engineering tool developed by the National Renewable Energy Laboratory targeted at accurately and efficiently predicting wind turbine power production and structural loading in wind farm settings, including wake interactions between turbines. FAST.Farm is based on some of the principles of the Dynamic Wake Meandering model—including passive tracer modeling of wake meandering—but addresses many of the limitations of previous Dynamic Wake Meandering (DWM) implementations. Previous FAST.Farm verification studies show the similarities and differences between FAST.Farm and large-eddy simulations for rigid and flexible turbines. In this validation study, FAST.Farm turbine responses are compared to multiturbine measurements from a subset of a full-scale wind farm. FAST.Farm predictions of turbine generator power, rotor speed, and blade pitch for five-turbine simulations are compared to supervisory control and data acquisition results. Results reveal that FAST.Farm generator power mean and standard deviation results reasonably match measured data for upstream and downstream turbines, as well as the mean rotor speed and blade pitch above rated wind speeds. However, FAST.Farm generally underpredicts the mean rotor speed and overpredicts the mean blade pitch below rated operation. These errors are likely related to inaccuracies in the generic controller simulated. Despite controller differences, FAST.Farm predicts the same overall relative rotor power trends for all waked turbines at all wind speeds.

17 WIND ENERGY↗

Secure Data Transfer Guidance for Industrial Control and SCADA Systems

This document was developed to provide guidance for the implementation of secure data transfer in a complex computational infrastructure representative of the electric power and oil and natural gas enterprises and the control systems they implement. For the past 20 years the cyber security community has focused on preventative measures intended to keep systems secure by providing a hard outer shell that is difficult to penetrate. Over time, the hard exterior, soft interior focus changed to focus on defense-in-depth adding multiple layers of protection, introducing intrusion detection systems, more effective incident response and cleanup, and many other security measures. Despite much larger expenditures and more layers of defense, successful attacks have only increased in number and severity. Consequently, it is time to re-focus the conventional approach to cyber security. While it is still important to implement measures to keep intruders out, a new protection paradigm is warranted that is aimed at discovering attempted or real compromises as early as possible. Put simply, organizations should take as fact that they have been, are now, or will be compromised. These compromises may be intended to steal information for financial gain as in the theft of intellectual property or credentials that lead to the theft of financial resources, or to lie silent until instructed to cause physical or electronic damage and/or denial of services. This change in outlook has been recently confirmed by the National Security Agency [19]. The discovery of attempted and actual compromises requires an increased focus on monitoring events by manual and/or automated log monitoring, detecting unauthorized changes to a system's hardware and/or software, detecting intrusions, and/or discovering the exfiltration of sensitive information and/or attempts to send inappropriate commands to ICS/SCADA (Industrial Control System/Supervisory Control And Data Acquisition) systems.

03 NATURAL GAS↗

Cyber-Informed Engineering Workbook: SCADA (VoltVAR)

This case study workbook provides a hypothetical project to support discussion and application of Cyber-Informed Engineering principles. Participants in the workshop are encouraged to use the workbook to capture insights and lessons learned.

42 - ENGINEERING↗

National SCADA Test Bed Substation Automation Evaluation Report

Increased awareness of the potential for cyber attack has recently resulted in improved cyber security practices associated with the electrical power grid. However, the level of practical understanding and deployment of cyber security practices has not been evenly applied across all business sectors. Much of the focus has been centered on information technology business centers and control rooms. This report explores the current level of substation automation, communication, and cyber security protection deployed in electrical substations throughout existing utilities in the United States. This report documents the evaluation of substation automation implementation and associated vulnerabilities. This evaluation used research conducted by Newton-Evans Research Company for some of its observations and results. The Newton Evans Report aided in the determination of what is the state of substation automation in North American electric utilities. Idaho National Laboratory cyber security experts aided in the determination of what cyber vulnerabilities may pose a threat to electrical substations. This report includes cyber vulnerabilities as well as recommended mitigations. It also describes specific cyber issues found in typical substation automation configurations within the electric utility industry. The evaluation report was performed over a 5-month period starting in October 2008

24 POWER TRANSMISSION AND DISTRIBUTION↗

Itron Open Way Security Assessment - SCADA

INL in collaboration with Itron, Inc. performed a laboratory assessment on the Itron, Inc. OpenWay Automated Metering System. During this assessment, vulnerabilities were discovered, evaluated, and mitigation strategies developed. These results were reported to Itron, Inc. to guide their efforts towards improved cyber security of their Smartgrid products.

Source record↗

Analytical Functions for 200 West Pump-and-Treat SCADA Sensor Data

Historical operations at the U.S. Department of Energy’s Hanford Site included disposal of waste fluids to the subsurface in the 200 West Area on the Hanford Central Plateau. Subsequent infiltration of fluids has resulted in groundwater contamination with carbon tetrachloride, nitrate, uranium, technetium-99, and other contaminants. A pump-and-treat (P&T) system, with an extraction/injection well network and an aboveground treatment plant, was implemented as part of interim and final remedies in the 200 West area. The HYPATIA single-page web application (part of the SOCRATES suite) is being developed to provide access to and analysis of chemistry and treatment facility sensor data for this 200 West P&T system. For the web application, analytical algorithms were developed to perform summing, differencing, smoothing, outlier detection, change-point detection, mass flow rate, and injectivity calculations on the data. Candidate algorithms were identified and tested, with the best-performing algorithms then assembled for implementation in HYPATIA. Because HYPATIA is hosted on the Amazon Web Services (AWS) cloud computing platform, algorithms were implemented in a back-end AWS Lambda function that can be called by the HYPATIA front end. The Lambda function applies the requested data processing to specified data via functions written in R, Python, and JavaScript. Development, testing, and review of the data analysis algorithms was completed under an NQA-1 quality program. This new HYPATIA functionality will provide information to support site decisions regarding P&T system performance and optimization.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗