Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SAMPLE HOLDERS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Application of a novel TPR EXAFS/XANES method using a multi-sample holder to characterize promoted iron and cobalt fFischer-Tropsch synthesis catalysts.

Coal-to-liquids. Iron-based Fischer-Tropsch synthesis catalysts are not only used commercially for high temperature Fischer-Tropsch synthesis, but are increasingly becoming the focus for converting low H{sub 2}/CO ratio synthesis gas at lower temperature. Such low temperature processing yields hydrocarbon distributions with higher {alpha} values, and as a consequence, much less light hydrocarbon gas production (and especially, less methane). Another benefit to the use of iron-based catalysts is that the product slate is richer in {alpha}-olefinic products, which are more valuable than the paraffinic products produced using cobalt-based catalysts. Iron-based catalysts are often used to convert low H{sub 2}/CO ratio syngas, because the catalysts can intrinsically adjust the syngas ratio upward by converting a fraction of CO by reaction with H{sub 2}O to produce H{sub 2} and CO{sub 2} via the water-gas shift reaction.

01 COAL, LIGNITE, AND PEAT↗

SEM technique for imaging and measuring electronic transport in nanocomposites based on electric field induced contrast

Methods and apparatus are described for SEM imaging and measuring electronic transport in nanocomposites based on electric field induced contrast. A method includes mounting a sample onto a sample holder, the sample including a sample material; wire bonding leads from the sample holder onto the sample; placing the sample holder in a vacuum chamber of a scanning electron microscope; connecting leads from the sample holder to a power source located outside the vacuum chamber; controlling secondary electron emission from the sample by applying a predetermined voltage to the sample through the leads; and generating an image of the secondary electron emission from the sample. An apparatus includes a sample holder for a scanning electron microscope having an electrical interconnect and leads on top of the sample holder electrically connected to the electrical interconnect; a power source and a controller connected to the electrical interconnect for applying voltage to the sample holder to control the secondary electron emission from a sample mounted on the sample holder; and a computer coupled to a secondary electron detector to generate images of the secondary electron emission from the sample.

47 OTHER INSTRUMENTATION↗

Summer Student Internship: Experimental and modeling experiences

My internship at the Los Alamos National Laboratory has been an information-filled summer. Loren Espada-Castillo brought me into her project and helped mentor and guide me through the summer. The project that I was brought into was the process of shooting materials with electrons. The electron beam we used conducts a series of shots in which electrons are generated and then fired towards a target, the sample holder. The sample holder holds either a single sample or three samples. The sample holder also consists of multiple calorimeters surrounding the sample/s. The goal is to shoot certain materials and then analyze how they react to the exposure of the electrons. We shot titanium, which was meant to serve as a containment vessel window.

36 MATERIALS SCIENCE↗

Infrared (IR) photon-sensitive spectromicroscopy in a cryogenic environment

A system designed to suppress thermal radiation background and to allow IR single-photon sensitive spectromicroscopy of small samples by using both absorption, reflection, and emission/luminescence measurements. The system in one embodiment includes: a light source; a plurality of cold mirrors configured to direct light along a beam path; a cold or warm sample holder in the beam path; windows of sample holder (or whole sample holder) are transparent in a spectral region of interest, so they do not emit thermal radiation in the same spectral region of interest; a cold monochromator or other cold spectral device configured to direct a selected fraction of light onto a cold detector; a system of cold apertures and shields positioned along the beam path to prevent unwanted thermal radiation from arriving at the cold monochromator and/or the detector; a plurality of optical, IR and microwave filters positioned along the beam path and configured to adjust a spectral composition of light incident upon the sample under investigation and/or on the detector; a refrigerator configured to maintain the detector at a temperature below 1.0K; and an enclosure configured to: thermally insulate the light source, the plurality of mirrors, the sample holder, the cold monochromator and the refrigerator.

47 OTHER INSTRUMENTATION↗

A compact apparatus for studies of element and phase-resolved ferromagnetic resonance

We present a compact sample holder equipped with electromagnets and high frequency transmission lines; the sample holder is intended for combined x-ray magnetic circular dichroism (XMCD) and ferromagnetic resonance measurements (FMR). Time-resolved measurements of resonant x-ray detected FMR during forced precession are enabled by use of a rf excitation that is phase-locked to the storage ring bunch clock. Several applications of the combined XMCD+FMR technique are presented, demonstrating the flexibility of the experimental design.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Evaluation of Cooling Conditions for a High Heat Flux Testing Facility Based on Plasma-Arc Lamps

The new Irradiated Material Target Station (IMTS) facility for fusion materials at Oak Ridge National Laboratory (ORNL) uses an infrared plasma-arc lamp (PAL) to deliver incident heat fluxes as high as 27 MW/m 2 . The facility is being used to test irradiated plasma-facing component materials as part of the joint US-Japan PHENIX program. The irradiated samples are to be mounted on molybdenum sample holders attached to a water-cooled copper rod. Depending on the size and geometry of samples, several sample holders and copper rod configurations have been fabricated and tested. As a part of the effort to design sample holders compatible with the high heat flux (HHF) testing to be conducted at the IMTS facility, numerical simulations have been performed for two different water-cooled sample holder designs using the ANSYS FLUENT 14.0 commercial computational fluid dynamics (CFD) software package. The primary objective of this work is to evaluate the cooling capability of different sample holder designs, i.e. to estimate their maximum allowable incident heat flux values. 2D axisymmetric numerical simulations are performed using the realizable k-ε turbulence model and the RPI nucleate boiling model within ANSYS FLUENT 14.0. The results of the numerical model were compared against the experimental data for two sample holder designs tested in the IMTS facility. The model has been used to parametrically evaluate the effect of various operational parameters on the predicted temperature distributions. The results were used to identify the limiting parameter for safe operation of the two sample holders and the associated peak heat flux limits. The results of this investigation will help guide the development of new sample holder designs.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Bias-Modulated ALD of ZnO: Insights into Precursor-Surface Interactions for ZnO Films

Atomic layer deposition (ALD) is widely used to deposit conformal thin films but is often limited in the tunability of the resulting material’s properties. Substrate bias and electric fields alter precursor-surface interactions and provide means to tune material properties. To explore this, we performed zinc oxide (ZnO) ALD using diethylzinc (DEZ) and water on silicon native oxide substrates at 150 °C in a sample holder designed to create a static electrical field by biasing one plate of a parallel plate capacitor-style sample holder during deposition. ZnO films prepared in an electric field/on a biased sample holder were thinner, changed relative crystalline composition, and contained more carbon compared to samples grown in identical sample holders without bias. The thickness was independent of the magnitude of the eletric field between plates, indicating that the primary driver for the change was substrate biasing not the electric field between plates of the parallel plate capacitor-style sample holder. Density functional theory calculations showed enhanced electron migration between dissociatively adsorbed DEZ molecules and the ZnO (002) facet with increasing force from an electric field at the substrate surface, which strengthens the electronic interactions between the surface and the adsorbate. These models offer a compelling explanation for the inhibited growth, changes in the crystallinity, and increase in carbon content of films grown in an electric field/on biased plates.

Jones, Jessica C. (ORCID:0000000174754620)↗

Fiber optical assembly for fluorescence spectrometry

A system for analyzing a sample for the presence of an analyte in a sample. The system includes a sample holder for containing the sample; an excitation source, such as a laser, and at least one linear array radially disposed about the sample holder. Radiation from the excitation source is directed to the sample, and the radiation induces fluorescent light in the sample. Each linear array includes a plurality of fused silica optical fibers that receive the fluorescent light and transmits a fluorescent light signal from the first end to an optical end port of the linear array. An end port assembly having a photo-detector is optically coupled to the optical end port. The photo-detector detects the fluorescent light signal and converts the fluorescent light signal into an electrical signal.

Rubenstein, Richard↗

A new apparatus design for high temperature (up to 950 °C) quasi-elastic neutron scattering in a controlled gaseous environment

A design for a sample cell system suitable for high temperature Quasi-Elastic Neutron Scattering (QENS) experiments is presented. The apparatus was developed at the Spallation Neutron Source in Oak Ridge National Lab where it is currently in use. The design provides a special sample cell environment under controlled humid or dry gas flow over a wide range of temperature up to 950 °C. Using such a cell, chemical, dynamical, and physical changes can be studied in situ under various operating conditions. While the cell combined with portable automated gas environment system is especially useful for in situ studies of microscopic dynamics under operational conditions that are similar to those of solid oxide fuel cells, it can additionally be used to study a wide variety of materials, such as high temperature proton conductors. The cell can also be used in many different neutron experiments when a suitable sample holder material is selected. The sample cell system has recently been used to reveal fast dynamic processes in quasi-elastic neutron scattering experiments, which standard probes (such as electrochemical impedance spectroscopy) could not detect. In this work, we outline the design of the sample cell system and present results demonstrating its abilities in high temperature QENS experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A compact high-performance low-field NMR apparatus for measurements on fluids at very high pressures and temperatures

We discuss an innovative new high-performance apparatus for performing low-field Nuclear Magnetic Resonance (NMR) relaxation times and diffusion measurements on fluids at very high pressures and high temperatures. The apparatus sensor design and electronics specifications allow for dual deployment either in a fluid sampling well logging tool or in a laboratory. The sensor and electronics were designed to function in both environments. This paper discusses the use of the apparatus in a laboratory environment. The operating temperature and pressure limits, and the signal-to-noise ratio (SNR) of the new system exceed by a very wide margin what is currently possible. This major breakthrough was made possible by a revolutionary new sensor design that breaks many of the rules of conventional high pressure NMR sensor design. A metallic sample holder capable of operating at high pressures and temperatures is provided to contain the fluid under study. The sample holder has been successfully tested for operation up to 36 Kpsi. A solenoid coil wound on a slotted titanium frame sits inside the metallic sample holder and serves as an antenna to transmit RF pulses and receive NMR signals. The metal sample holder is sandwiched between a pair of gradient coils which provide a linear field gradient for pulsed field gradient diffusion measurements. The assembly sits in the bore of a low-gradient permanent magnet. The system can operate over a wide frequency range without the need for tuning the antenna to the Larmor frequency. The SNR measured on a water sample at room temperature is more than 15 times greater than that of the commercial low-field system in our laboratory. Thus, the new system provides for data acquisition more than 200 times faster than was previously possible. Laboratory NMR measurements of relaxations times and diffusion coefficients performed at pressures up to 25 Kpsi and at temperatures up to 175 °C with crude oils enlivened with dissolved hydrocarbon gases (referred to as “live oils”) are shown. This is the first time low-field NMR measurements have been performed at such high temperatures and pressures on live crude oil samples. We discuss the details of the apparatus design, tuning, calibration, and operation. NMR data acquired at multiple temperatures and pressures on a live oil sample are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Real-time SEM studies in controlled reactive atmospheres

A unique scanning electron accessory has been developed that allows the observation of specimens under partial pressures of any gas. The sample is placed in a metal support boat inside a special sample holder. The sample in the boat is imaged on a CRT and is simultaneously recorded on a videotape, allowing the reaction between the sample and the gas to be observed in real time. Sample changes can be seen continuously as the sample is being heated or cooled. This process allows the observation of material transformations such as phase changes as they happen. Temperatures as high as 1000 C have been used and are continuously monitored using a thermocouple with a digital display on the CRT and videotape. X-ray analyses can also be run before and after any reactions. In the study described here, thick-film screen-printing inks using molybdenum/tin compositions as a replacement for silver were developed to be used on terrestrial photovoltaic cells. Pieces were placed on the sample stage and heated in both O2 and H2 atmospheres. The results were used to determine the most effective frits to be used in the thick-film inks.

Gallagher, B. D.↗

Fourth-generation plasma immersion ion implantation and deposition facility for hybrid surface modification layer fabrication

The fourth-generation plasma immersion ion implantation and deposition (PIIID) facility for hybrid and batch treatment was built in our laboratory recently. Comparing with our previous PIIID facilities, several novel designs are utilized. Two multicathode pulsed cathodic arc plasma sources are fixed on the chamber wall symmetrically, which can increase the steady working time from 6 h (the single cathode source in our previous facilities) to about 18 h. Meanwhile, the inner diameter of the pulsed cathodic arc plasma source is increased from the previous 80 to 209 mm, thus, large area metal plasma can be obtained by the source. Instead of the simple sample holder in our previous facility, a complex revolution-rotation sample holder composed of 24 shafts, which can rotate around its axis and adjust its position through revolving around the center axis of the vacuum chamber, is fixed in the center of the vacuum chamber. In addition, one magnetron sputtering source is set on the chamber wall instead of the top cover in the previous facility. Because of the above characteristic, the PIIID hybrid process involving ion implantation, vacuum arc, and magnetron sputtering deposition can be acquired without breaking vacuum. In addition, the PIIID batch treatment of cylinderlike components can be finished by installing these components on the rotating shafts on the sample holder.

36 MATERIALS SCIENCE↗

System and method for assaying radiation

A system for assaying radiation includes a sample holder configured to hold a liquid scintillation solution. A photomultiplier receives light from the liquid scintillation solution and generates a signal reflective of the light. A control circuit biases the photomultiplier and receives the signal from the photomultiplier reflective of the light. A light impermeable casing surrounds the sample holder, photomultiplier, and control circuit. A method for assaying radiation includes placing a sample in a liquid scintillation solution, placing the liquid scintillation solution in a sample holder, and placing the sample holder inside a light impermeable casing. The method further includes positioning a photomultiplier inside the light impermeable casing and supplying power to a control circuit inside the light impermeable casing.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Solution scattering at the Life Science X-ray Scattering (LiX) beamline

This work reports the instrumentation and software implementation at the Life Science X-ray Scattering (LiX) beamline at NSLS-II in support of biomolecular solution scattering. For automated static measurements, samples are stored in PCR tubes and grouped in 18-position sample holders. Unattended operations are enabled using a six-axis robot that exchanges sample holders between a storage box and a sample handler, transporting samples from the PCR tubes to the X-ray beam for scattering measurements. The storage box has a capacity of 20 sample holders. At full capacity, the measurements on all samples last for ∼9 h. For in-line size-exclusion chromatography, the beamline-control software coordinates with a commercial high-performance liquid chromatography (HPLC) system to measure multiple samples in batch mode. The beamline can switch between static and HPLC measurements instantaneously. In all measurements, the scattering data span a wide q -range of typically 0.006–3.2 Å −1 . Functionalities in the Python package py4xs have been developed to support automated data processing, including azimuthal averaging, merging data from multiple detectors, buffer scattering subtraction, data storage in HDF5 format and exporting the final data in a three-column text format that is acceptable by most data analysis tools. These functionalities have been integrated into graphical user interfaces that run in Jupyter notebooks, with hooks for external data analysis software.

60 APPLIED LIFE SCIENCES↗

Dust Studies in DIII-D and TEXTOR

Studies of naturally occurring and artificially introduced carbon dust are conducted in DIII-D and TEXTOR. In DIII-D, dust does not present operational concerns except immediately after entry vents. Submicron sized dust is routinely observed using Mie scattering from a Nd:Yag laser. The source is strongly correlated with the presence of Type I edge localized modes (ELMs). Larger size (0.005-1 mm diameter) dust is observed by optical imaging, showing elevated dust levels after entry vents. Inverse dependence of the dust velocity on the inferred dust size is found from the imaging data. Direct heating of the dust particles by the neutral beam injection (NBI) and acceleration of dust particles by the plasma flows are observed. Energetic plasma disruptions produce significant amounts of dust. Large flakes or debris falling into the plasma may result in a disruption. Migration of pre-characterized carbon dust is studied in DIII-D and TEXTOR by introducing micron-size dust in plasma discharges. In DIII-D, a sample holder filled with {approx}30 mg of dust is introduced in the lower divertor and exposed to high-power ELMing H-mode discharges with strike points swept across the divertor floor. After a brief exposure ({approx}0.1 s) at the outer strike point, part of the dust is injected into the plasma, raising the core carbon density by a factor of 2-3 and resulting in a twofold increase of the radiated power. In TEXTOR, instrumented dust holders with 1-45 mg of dust are exposed in the scrape-off layer 0-2 cm radially outside of the last closed flux surface in discharges heated with neutral beam injection (NBI) power of 1.4 MW. At the given configuration of the launch, the dust did not penetrate the core plasma and only moderately perturbed the edge plasma, as evidenced by an increase of the edge carbon content.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Study of etching rate uniformity in SRF cavities

Plasma based surface modification is a promising alternative to wet etching of superconducting radio frequency (SRF) cavities. The crucial aspect of the technology development is dependence of the etching rate and surface roughness on the frequency of the power supply, pressure, power level, driven electrode shape and chlorine concentration in the gas mixture during plasma processing. To optimize the plasma parameters, we are using a single cell cavity with 20 sample holders symmetrically distributed over the cell. These holders are used as diagnostic ports for the measurement of the plasma parameters and as holders for the samples to be etched. The plasma properties are highly correlated with the shape of the driven electrode and chlorine concentration in the Argon/Chlorine gas mixtures.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The laser shock station in the dynamic compression sector. I

The Laser Shock Station in the Dynamic Compression Sector [Advanced Photon Source (APS), Argonne National Laboratory] links a laser-driven shock compression platform with high energy x-ray pulses from the APS to achieve in-situ, time-resolved x-ray measurements (diffraction and imaging) in materials subjected to well-characterized, high stress, short duration planar shock waves. Additionally, the combination of this station and the other DCS experimental stations provides a unique and versatile experimental facility to study condensed state phenomena by undertaking real-time, multi-scale measurements in materials subjected to a wide range of shock amplitudes (to above ~350 GPa) and time-durations (~10 ns to 1 μs). The Laser Shock Station uses a 100 joule, 5-17 ns, 351 nm frequency tripled Nd:glass laser with programmable pulse shaping and focal profile smoothing for maximum precision. The laser is capable of a shot every 30 minutes. The interaction chamber contains multiple ports for simultaneous diagnostics, a sample holder that allows sequential exposure for 14 samples without breaking vacuum, the capability to vary the angle between the x-ray beam and laser beam by 135°, and the ability to translate to select one of two types of x-ray beams. X-ray data can be taken with a temporal resolution of ~90 psec. Highly reproducible, planar shocks can be propagated in samples to undertake precise and well-characterized experiments. In a series of ten shots, the absolute variation in the time the shock breaks out at the back of the sample is less than 500ps and the variation in peak particle velocity at the sample/window interface is 4.3%. Lastly, this paper describes the entire DCS Laser Shock Station, including sample fabrication and diagnostics, as well as representative experimental results from shock compressed tantalum to demonstrate the excellent quality of x-ray diffraction data in solid tantalum and to establish the stress for tantalum melting.

47 OTHER INSTRUMENTATION↗