Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Retinal Vessels”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

52 records · Page 3

Portable Video/Digital Retinal Funduscope

Lightweight, inexpensive electronic and photographic instrument developed for detection, monitoring, and objective quantification of ocular/systemic disease or physiological alterations of retina, blood vessels, or other structures in anterior and posterior chambers of eye. Operated with little training. Functions with human or animal subject seated, recumbent, inverted, or in almost any other orientation; and in hospital, laboratory, field, or other environment. Produces video images viewed directly and/or digitized for simultaneous or subsequent analysis. Also equipped to produce photographs and/or fitted with adaptors to produce stereoscopic or magnified images of skin, nose, ear, throat, or mouth to detect lesions or diseases.

Taylor, Gerald R.↗

Modification of a Kowa RC-2 fundus camera for self-photography without the use of mydriatics

Research on retinal circulation during space flight required the development of a simple technique to provide self monitoring of blood vessel changes in the fundus without the use of mydriatics. A Kowa RC-2 fundus camera was modified for self-photography by the use of a bite plate for positioning and cross hairs for focusing the subject's retina relative to the film plane. Dilation of the pupils without the use of mydriatics was accomplished by dark-adaption of the subject. Pictures were obtained without pupil constriction by the use of a high speed strobe light. This method also has applications for clinical medicine.

Philpott, D. E.↗

The Portable Dynamic Fundus Instrument: Uses in telemedicine and research

For years ophthalmic photographs have been used to track the progression of many ocular diseases such as macular degeneration and glaucoma as well as the ocular manifestations of diabetes, hypertension, and hypoxia. In 1987 a project was initiated at the Johnson Space Center (JSC) to develop a means of monitoring retinal vascular caliber and intracranial pressure during space flight. To conduct telemedicine during space flight operations, retinal images would require real-time transmissions from space. Film-based images would not be useful during in-flight operations. Video technology is beneficial in flight because the images may be acquired, recorded, and transmitted to the ground for rapid computer digital image processing and analysis. The computer analysis techniques developed for this project detected vessel caliber changes as small as 3 percent. In the field of telemedicine, the Portable Dynamic Fundus Instrument demonstrates the concept and utility of a small, self-contained video funduscope. It was used to record retinal images during the Gulf War and to transmit retinal images from the Space Shuttle Columbia during STS-50. There are plans to utilize this device to provide a mobile ophthalmic screening service in rural Texas. In the fall of 1993 a medical team in Boulder, Colorado, will transmit real-time images of the retina during remote consultation and diagnosis. The research applications of this device include the capability of operating in remote locations or small, confined test areas. There has been interest shown utilizing retinal imaging during high-G centrifuge tests, high-altitude chamber tests, and aircraft flight tests. A new design plan has been developed to incorporate the video instrumentation into face-mounted goggle. This design would eliminate head restraint devices, thus allowing full maneuverability to the subjects. Further development of software programs will broaden the application of the Portable Dynamic Fundus Instrument in telemedicine and medical research.

Hunter, Norwood↗

The retinal funduscope demonstration project

A lightweight, relatively inexpensive electronic and photographic instrument has been re-developed for the detection, monitoring, and objective quantification of ocular/ systemic disease or physiological alterations of the retina, blood vessels, or other structures in the anterior and posterior chambers of the eye. The instrument can be operated with little training. It can function with a human or animal subject seated, recumbent, inverted, or in almost any other orientation; and in a hospital, laboratory, field, or other environment. The instrument produces video images that can be viewed directly and/or digitized for simultaneous or subsequent analysis. It can also be equipped to produce photographs and/or fitted with adaptors to produce stereoscopic or magnified images ot the skin, nose, ear, throat, or mouth to detect lesions or diseases.

Wilhelm, Jim↗

Renin-Angiotensin System (RAS) in Hematopoietic Stem/Progenitor Cells (HS/PC) Predicts Vaso-Reparative Dysfunction and Progression of Diabetic Retinopathy (DR)

Purpose: We tested the hypothesis that loss of angiotensin converting enzyme 2 (ACE2) within diabetic HS/PCs (Hematopoietic Stem/Progenitor Cells) would be detrimental to HS/PC reparative function, and alter their ability to contribute to vascular remodeling in human subjects and rodent models of DR (Diabetic Retinopathy). Methods: Subjects (n52) were recruited as controls (n13) or diabetics (n39) with either no DR, mild non-proliferative DR (NPDR), moderate NPDR, severe NPDR or proliferative DR (PDR). Fluorescein angiograms were analyzed using Vessel Generation Analysis (VESGEN) software in a cohort of subjects. CD34+ HS/PCs were isolated from peripheral blood. RAS (Renin-Angiotensin System) gene expression and migration was measured. Diabetic ACE2 knockout (KO)C57BL6-Ins2 (Akita) mice at 3, 6 and 9 months of diabetes were compared to age-matched controls. Bone marrow HS/PC populations were analyzed by flow cytometry and migration and proliferation studies performed. Results: ACE2 gene expression in human CD34+ cells from diabetics without DR was increased compared to controls (p0.0437). Mas receptor mRNA was also increased in diabetics without DR, but reduced with the onset of NPDR (p0.0002), suggesting a loss of compensation. DR was associated with CD34+ cell migratory dysfunction. By VESGEN analysis, vessel density measured by several confirming parameters in early NPDR (n3) was greater than in normal retina (n6) in both arteries and veins, which suggests active retinal remodeling. ACE2KO-Akita and Akita cohorts showed reduced retinal thickness by OCT (Optical Coherence Tomography) at 9 months of diabetes. Absence of ACE2 in 9-month Akita mice led to an accelerated increase in acellular capillaries compared to diabetic alone. Electroretinogram (ERG) in ACE2KO-Akita mice resulted in persistent deterioration of the neural retina. Reparative function studies showed that ACE2KO exacerbated diabetes-induced impairment of LK (Low Potassium) cell migration and proliferative functions as early as 3-month of diabetes (p0.0019). Conclusions: Retinopathy and adverse vascular remodeling in subjects with diabetes was associated with a loss of the protective arm of RAS in HS/PCs. Loss of ACE2 exacerbated vascular dysfunction in diabetic mice.

retina↗

Retinal Image Quality Assessment for Spaceflight-Induced Vision Impairment Study

Long-term exposure to space microgravity poses significant risks for visual impairment. Evidence suggests such vision changes are linked to cephalad fluid shifts, prompting a need to directly quantify microgravity-induced retinal vascular changes. The quality of retinal images used for such vascular remodeling analysis, however, is dependent on imaging methodology. For our exploratory study, we hypothesized that retinal images captured using fluorescein imaging methodologies would be of higher quality in comparison to images captured without fluorescein. A semi-automated image quality assessment was developed using Vessel Generation Analysis (VESGEN) software and MATLAB® image analysis toolboxes. An analysis of ten images found that the fluorescein imaging modality provided a 36% increase in overall image quality (two-tailed p=0.089) in comparison to nonfluorescein imaging techniques.

retina↗

Retinal Embolization During Carotid Angioplasty and Stenting: Periprocedural Data and Follow-Up

The purpose of this study was to prospectively evaluate the incidence of retinal emboli during carotid angioplasty and stenting (CAS) and to correlate emboli with clinical findings and transcranial Doppler (TCD)-detected cerebral embolic load. Between 2001 and 2005, 33 CAS procedures in 32 patients (23 [72%] male, 19 [58%] symptomatic, mean age 72.5 years [range 54.6 to 83.9]) scheduled for CAS were included in this study. Bilateral fundoscopy with retinal photography was performed by an experienced ophthalmologist immediately before, immediately after (fundoscopy only), and 1 day after the procedure and again at long-term follow-up (mean 37 months). Visual field testing was performed before CAS and again at long-term follow-up. TCD-detected cerebral emboli were stratified to five procedural phases: wiring, predilatation, stent placement, postdilatation, and cerebral protection device (CPD) use (if applicable). To establish correlation between TCD data and retinal embolization, Mann-Whitney test was used, and P < 0.05 was considered statistically significant. All procedures were performed successfully. In five of 33 procedures (15%), new retinal emboli were found. Two of the procedures with emboli had small retinal infarcts. Three of five were performed using CPDs versus seven of 28 that had no retinal emboli (P = not significant). Two of four patients (50%) with previous radiation therapy to the neck had new retinal emboli versus three of 29 patients (10%) who had no previous radiation therapy (P = 0.038). None of the other patient characteristics was associated with retinal embolization. In 30 (91%) of patients with an adequate acoustic temporal window for TCD monitoring, there was no statistically significant correlation between TCD data and the incidence of retinal emboli. No visual field defects were found. On long-term follow-up, all retinal emboli and retinal infarcts had resolved. Retinal embolization during CAS is not uncommon, and it occurs in both protected and unprotected procedures. Most retinal emboli are clinically silent.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Adhesion Failures Determine the Pattern of Choroidal Neovascularization in the Eye: A Computer Simulation Study

Choroidal neovascularization (CNV) of the macular area of the retina is the major cause of severe vision loss in adults. In CNV, after choriocapillaries initially penetrate Bruch’s membrane (BrM), invading vessels may regress or expand (CNV initiation). Next, during Early and Late CNV, the expanding vasculature usually spreads in one of three distinct patterns: in a layer between BrM and the retinal pigment epithelium (sub-RPE or Type 1 CNV), in a layer between the RPE and the photoreceptors (subretinal or Type 2 CNV) or in both loci simultaneously (combined pattern or Type 3 CNV). While most studies hypothesize that CNV primarily results from growth-factor effects or holes in BrM, our three-dimensional simulations of multi-cell model of the normal and pathological maculae recapitulate the three growth patterns, under the hypothesis that CNV results from combinations of impairment of: 1) RPE-RPE epithelial junctional adhesion, 2) Adhesion of the RPE basement membrane complex to BrM (RPE-BrM adhesion), and 3) Adhesion of the RPE to the photoreceptor outer segments (RPE-POS adhesion). Our key findings are that when an endothelial tip cell penetrates BrM: 1) RPE with normal epithelial junctions, basal attachment to BrM and apical attachment to POS resists CNV. 2) Small holes in BrM do not, by themselves, initiate CNV. 3) RPE with normal epithelial junctions and normal apical RPE-POS adhesion, but weak adhesion to BrM (e.g. due to lipid accumulation in BrM) results in Early sub-RPE CNV. 4) Normal adhesion of RBaM to BrM, but reduced apical RPE-POS or epithelial RPE-RPE adhesion (e.g. due to inflammation) results in Early sub-retinal CNV. 5) Simultaneous reduction in RPE-RPE epithelial binding and RPEBrM adhesion results in either sub-RPE or sub-retinal CNV which often progresses to combined pattern CNV. These findings suggest that defects in adhesion dominate CNV initiation and progression.

59 BASIC BIOLOGICAL SCIENCES↗

Hindlimb Suspension (HLS) in Rodents for the Study of Intracranial Pressure, Molecular and Histologic Changes in the Eye, and CSF Production Regulation and Resorption: A Status Report of Two Studies

This status report corresponds to two studies tied to an animal experiment being executed at the University of California Davis (Charles Fuller's laboratory). The animal protocol uses the well-documented rat hindlimb suspension (HLS) model, to examine the relationship between cephalic fluid shifts and the regulation of intracranial (ICP) and intraocular (IOP) pressures as well as visual system structure and function. Long Evans rats are subjected to HLS durations of 7, 14, 28 and 90 days. Subgroups of the 90-day animals are studied for recovery periods of 7, 14, 28 or 90 days. All HLS subjects have age-matched cage controls. Various animal cohorts are planned for this study: young males, young females and old males. In addition to the live measures (ICP by telemetry, IOP and retinal parameters by optical coherence tomography) which are shared with the Fuller study, the specific outcomes for this study include: -Gene expression analysis of the retina -Histologic analysis - Analysis of the microvasculature of retina flat mounts by NASA's VESsel GENeration Analysis (VESGEN) Software. To date, the young male and female cohorts are being completed. Due to the need to keep technical variation to a minimum, the histologic and genomic analyses have been delayed until all samples from each cohort are available and can be processed in a single batch per cohort. The samples received so far correspond to young males sacrificed at 7,14, 28 and 90 days of HLS and at 90 days of recovery; and from young females sacrificed at 7, 14 and 28 of HLS. A complementary study titled: "A gene expression and histologic approach to the study of cerebrospinal fluid (CSF) production and outflow in hindlimb suspended rats" seeks to study the molecular components of CSF production and outflow modulation as a result of HLS, bringing a molecular and histologic approach to investigate genome wide expression changes in the arachnoid villi and choroid plexus of HLS rats compared to rats in normal posture.

Theriot, C. A.↗

Transplanting Retinal Cells using Bucky Paper for Support

A novel treatment for retinal degenerative disorders involving transplantation of cells into the eye is currently under development at NASA Ames Research Center and Stanford University School of Medicine. The technique uses bucky paper as a support material for retinal pigment epithelial (RPE) cells, iris pigment epithelial (IPE) cells, and/or stem cells. This technology is envisioned as a treatment for age-related macular degeneration, which is the leading cause of blindness in persons over age 65 in Western nations. Additionally, patients with other retinal degenerative disorders, such as retinitis pigmentosa, may be treated by this strategy. Bucky paper is a mesh of carbon nanotubes (CNTs), as shown in Figure 1, that can be made from any of the commercial sources of CNTs. Bucky paper is biocompatible and capable of supporting the growth of biological cells. Because bucky paper is highly porous, nutrients, oxygen, carbon dioxide, and waste can readily diffuse through it. The thickness, density, and porosity of bucky paper can be tailored in manufacturing. For transplantation of cells into the retina, bucky paper serves simultaneously as a substrate for cell growth and as a barrier for new blood vessel formation, which can be a problem in the exudative type of macular degeneration. Bucky paper is easily handled during surgical implantation into the eye. Through appropriate choice of manufacturing processes, bucky paper can be made relatively rigid yet able to conform to the retina when the bucky paper is implanted. Bucky paper offers a distinct advantage over other materials that have been investigated for retinal cell transplantation - lens capsule and Descemet's membrane - which are difficult to handle during surgery because they are flimsy and do not stay flat.

Loftus, David J.↗

Image analysis of ocular fundus for retinopathy characterization

Automated analysis of ocular fundus images is a common procedure in countries as England, including both nonemergency examination and retinal screening of patients with diabetes mellitus. This involves digital image capture and transmission of the images to a digital reading center for evaluation and treatment referral. In collaboration with the Optometry Department, University of California, Berkeley, we have tested computer vision algorithms to segment vessels and lesions in ground-truth data (DRIVE database) and hundreds of images of non-macular centric and nonuniform illumination views of the eye fundus from EyePACS program. Methods under investigation involve mathematical morphology (Figure 1) for image enhancement and pattern matching. Recently, we have focused in more efficient techniques to model the ocular fundus vasculature (Figure 2), using deformable contours. Preliminary results show accurate segmentation of vessels and high level of true-positive microaneurysms.

60 APPLIED LIFE SCIENCES↗

Portable dynamic fundus instrument

A portable diagnostic image analysis instrument is disclosed for retinal funduscopy in which an eye fundus image is optically processed by a lens system to a charge coupled device (CCD) which produces recordable and viewable output data and is simultaneously viewable on an electronic view finder. The fundus image is processed to develop a representation of the vessel or vessels from the output data.

Taylor, Gerald R.↗

High-resolution retinal imaging using adaptive optics and Fourier-domain optical coherence tomography

This invention permits retinal images to be acquired at high speed and with unprecedented resolution in three dimensions (4.times.4.times.6 .mu.m). The instrument achieves high lateral resolution by using adaptive optics to correct optical aberrations of the human eye in real time. High axial resolution and high speed are made possible by the use of Fourier-domain optical coherence tomography. Using this system, we have demonstrated the ability to image microscopic blood vessels and the cone photoreceptor mosaic.

Olivier, Scot S↗

Quantifiable Biomarkers of Normal Aging in the Japanese Medaka Fish (Oryzias latipes)

Background: Small laboratory fish share many anatomical and histological characteristics with other vertebrates, yet can be maintained in large numbers at low cost for lifetime studies. Here we characterize biomarkers associated with normal aging in the Japanese medaka (Oryzias latipes), a species that has been widely used in toxicology studies and has potential utility as a model organism for experimental aging research. Principal Findings: The median lifespan of medaka was approximately 22 months under laboratory conditions. We performed quantitative histological analysis of tissues from age-grouped individuals representing young adults (6 months old), mature adults (16 months old), and adults that had survived beyond the median lifespan (24 months). Livers of 24- month old individuals showed extensive morphologic changes, including spongiosis hepatis, steatosis, ballooning degeneration, inflammation, and nuclear pyknosis. There were also phagolysosomes, vacuoles, and residual bodies in parenchymal cells and congestion of sinusoidal vessels. Livers of aged individuals were characterized by increases in lipofuscin deposits and in the number of TUNEL-positive apoptotic cells. Some of these degenerative characteristics were seen, to a lesser extent, in the livers of 16-month old individuals, but not in 6-month old individuals. The basal layer of the dermis showed an age-dependent decline in the number of dividing cells and an increase in senescence-associated bgalactosidase. The hearts of aged individuals were characterized by fibrosis and lipofuscin deposition. There was also a loss of pigmented cells from the retinal epithelium. By contrast, age-associated changes were not apparent in skeletal muscle, the ocular lens, or the brain. Significance: The results provide a set of markers that can be used to trace the process of normal tissue aging in medaka and to evaluate the effect of environmental stressors.

59 BASIC BIOLOGICAL SCIENCES↗

Central Retinal and Posterior Ciliary Artery Occlusion After Intralesional Injection of Sclerosant to Glabellar Subcutaneous Hemangioma

The aim of this study is to describe vision loss caused by central retinal artery and posterior ciliary artery occlusion as a consequence of sclerotherapy with a polidocanol injection to a glabellar hemangioma. An 18-year-old man underwent direct injection with a 23-gauge needle of 1 mL of a polidocanol-carbon dioxide emulsion into the glabellar subcutaneous hemangioma under ultrasound visualization of the needle tip by radiologists. He developed lid swelling the next day, and 3 days later at referral, the visual acuity in the left eye was no light perception. Funduscopy revealed central retinal artery occlusion and fluorescein angiography disclosed no perfusion at all in the left fundus, indicating concurrent posterior ciliary artery occlusion. The patient also showed mydriasis, blepharoptosis, and total external ophthalmoplegia on the left side. Magnetic resonance imaging demonstrated the swollen medial rectus muscle. In a month, blepharoptosis and ophthalmoplegia resolved but the visual acuity remained no light perception. Sclerosing therapy for facial hemangioma may develop a severe complication such as permanent visual loss.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Deep Learning Approaches to Surrogates for Solving the Diffusion Equation for Mechanistic Real-World Simulations

In many mechanistic medical, biological, physical, and engineered spatiotemporal dynamic models the numerical solution of partial differential equations (PDEs), especially for diffusion, fluid flow and mechanical relaxation, can make simulations impractically slow. Biological models of tissues and organs often require the simultaneous calculation of the spatial variation of concentration of dozens of diffusing chemical species. One clinical example where rapid calculation of a diffusing field is of use is the estimation of oxygen gradients in the retina, based on imaging of the retinal vasculature, to guide surgical interventions in diabetic retinopathy. Furthermore, the ability to predict blood perfusion and oxygenation may one day guide clinical interventions in diverse settings, i.e., from stent placement in treating heart disease to BOLD fMRI interpretation in evaluating cognitive function (Xie et al., 2019; Lee et al., 2020). Since the quasi-steady-state solutions required for fast-diffusing chemical species like oxygen are particularly computationally costly, we consider the use of a neural network to provide an approximate solution to the steady-state diffusion equation. Machine learning surrogates, neural networks trained to provide approximate solutions to such complicated numerical problems, can often provide speed-ups of several orders of magnitude compared to direct calculation. Surrogates of PDEs could enable use of larger and more detailed models than are possible with direct calculation and can make including such simulations in real-time or near-real time workflows practical. Creating a surrogate requires running the direct calculation tens of thousands of times to generate training data and then training the neural network, both of which are computationally expensive. Often the practical applications of such models require thousands to millions of replica simulations, for example for parameter identification and uncertainty quantification, each of which gains speed from surrogate use and rapidly recovers the up-front costs of surrogate generation. We use a Convolutional Neural Network to approximate the stationary solution to the diffusion equation in the case of two equal-diameter, circular, constant-value sources located at random positions in a two-dimensional square domain with absorbing boundary conditions. Such a configuration caricatures the chemical concentration field of a fast-diffusing species like oxygen in a tissue with two parallel blood vessels in a cross section perpendicular to the two blood vessels. To improve convergence during training, we apply a training approach that uses roll-back to reject stochastic changes to the network that increase the loss function. The trained neural network approximation is about 1000 times faster than the direct calculation for individual replicas. Because different applications will have different criteria for acceptable approximation accuracy, we discuss a variety of loss functions and accuracy estimators that can help select the best network for a particular application. We briefly discuss some of the issues we encountered with overfitting, mismapping of the field values and the geometrical conditions that lead to large absolute and relative errors in the approximate solution.

60 APPLIED LIFE SCIENCES↗