Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Relative accuracy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Intrafractional Target Motions and Uncertainties of Treatment Setup Reference Systems in Accelerated Partial Breast Irradiation

Purpose: This study investigated the magnitude of intrafractional motion and level of accuracy of various setup strategies in accelerated partial breast irradiation (APBI) using three-dimensional conformal external beam radiotherapy. Methods and Materials: At lumpectomy, gold fiducial markers were strategically sutured to the surrounding walls of the cavity. Weekly fluoroscopy imaging was conducted at treatment to investigate the respiration-induced target motions. Daily pre- and post-RT kV imaging was performed, and images were matched to digitally reconstructed radiographs based on bony anatomy and fiducial markers, respectively, to determine the intrafractional motion magnitudes over the course of treatment. The positioning differences of the laser tattoo- and the bony anatomy-based setups compared with those of the marker-based setup (benchmark) were also determined. The study included 21 patients. Results: Although lung exhibited significant motion, the average marker motion amplitude on the fluoroscopic image was about 1 mm. Over a typical treatment time period, average intrafractional motion magnitude was 4.2 mm and 2.6 mm based on the marker and bony anatomy matching, respectively. The bony anatomy- and laser tattoo-based interfractional setup errors, with respect to the fiducial marker-based setup, were 7.1 and 9.0 mm, respectively. Conclusions: Respiration has limited effects on the target motion during APBI. Bony anatomy-based treatment setup improves the accuracy relative to that of the laser tattoo-based setup approach. Since fiducial markers are sutured directly to the surgical cavity, the marker-based approach can further improve the interfractional setup accuracy. On average, a seroma cavity exhibits intrafractional motion of more than 4 mm, a magnitude that is larger than that which is otherwise derived based on bony anatomy matching. A seroma-specific marker-based approach has the potential to improve treatment accuracy by taking the true inter- and intrafractional motions into consideration.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Girder Alignment Plan

The girders for the LCLS undulator system contain components which must be aligned with high accuracy relative to each other. The alignment is one of the last steps before the girders go into the tunnel, so the alignment must be done efficiently, on a tight schedule. This note documents the alignment plan which includes efficiency and high accuracy. The motivation for girder alignment involves the following considerations. Using beam based alignment, the girder position will be adjusted until the beam goes through the center of the quadrupole and beam finder wire. For the machine to work properly, the undulator axis must be on this line and the center of the undulator beam pipe must be on this line. The physics reasons for the undulator axis and undulator beam pipe axis to be centered on the beam are different, but the alignment tolerance for both are similar. In addition, the beam position monitor must be centered on the beam to preserve its calibration. Thus, the undulator, undulator beam pipe, quadrupole, beam finder wire, and beam position monitor axes must all be aligned to a common line. All relative alignments are equally important, not just, for example, between quadrupole and undulator. We begin by making the common axis the nominal beam axis in the girder coordinate system. All components will be initially aligned to this axis. A more accurate alignment will then position the components relative to each other, without incorporating the girder itself.

43 PARTICLE ACCELERATORS↗

Towards Elucidating Structure–Spectra Relationships in Rhamnogalacturonan II: Computational Protocols for Accurate 13C and 1H Shifts for Apiose and Its Borate Esters

Apiose is a naturally occurring, uncommon branched-chain pentose found in plant cell walls as part of the complex polysaccharide Rhamnogalacturonan II (RG-II). The structural elucidation of the three-dimensional structure of RG-II by nuclear magnetic resonance (NMR) spectroscopy is significantly complicated by the ability of apiose to cross-link via borate ester linkages to form RG-II dimers. Here, we developed a computational approach to gain insight into the structure–spectra relationships of apio–borate complexes in an effort to complement experimental assignments of NMR signals in RG-II. Our protocol involved structure optimizations using density functional theory (DFT) followed by isotropic magnetic shielding constant calculations using the gauge-invariant atomic orbital (GIAO) approach to predict chemical shifts. We evaluated the accuracy of 23 different functional–basis set (FBS) combinations with and without implicit solvation for predicting the experimental 1 H and 13 C shifts of a methyl apioside and its three borate derivatives. The computed NMR predictions were evaluated on the basis of the overall shift accuracy, relative shift ordering, and the ability to distinguish between dimers and monomers. We demonstrate that the consideration of implicit solvation during geometry optimizations in addition to the magnetic shielding constant calculations greatly increases the accuracy of NMR chemical shift predictions and can correctly reproduce the ordering of the 13 C shifts and yield predictions that are, on average, within 1.50 ppm for 13 C and 0.12 ppm for 1 H shifts for apio–borate compounds.

BASIC BIOLOGICAL SCIENCES,BIOMASS FUELS↗

Measurement of vapor phase mercury emissions at coal-fired power plants using regular and speciating sorbent traps with in-stack and out-of-stack sampling methods

A systematic investigation of sorbent-trap sampling, which is a method that uses paired sorbent traps to measure total vapor phase mercury (Hg), was carried out at two coal-fired power plants. The objective of the study was to evaluate the effects (if any) on data quality when the following aspects of the sorbent trap method are varied: (a) sorbent trap configuration; (b) sampling time; and (c) analytical technique. Also, the performance of a speciating sorbent trap (i.e., a trap capable of separating elemental Hg from oxidized Hg), was evaluated by direct comparison against the Ontario Hydro (OH) reference method. Flue gas samples were taken using both 'regular' and modified sorbent trap measurement systems. Both short-term (1.5 h) and long-term (18 h to 10 days) samples were collected. The in-stack and out-of-stack sampling methods produced satisfactory relative accuracy results for both the short-term and long-term testing. For the short-term tests, the in-stack sampling results compared more favorably to the OH method than did the out-of-stack results. The relative deviation between the paired traps was considerably higher for the short-term out-of-stack tests than for the long-term tests. A one-way analysis of variance (ANOVA), showed a statistically significant difference (p < 0.1) between the direct combustion and wet-chemistry analytical methods used in the study; the results from the direct combustion method were consistently higher than the wet-chemistry results. The evaluation of the speciating mercury sorbent trap demonstrated that the trap is capable of providing reasonably accurate total mercury concentrations and speciation data that are somewhat comparable to data obtained with the OH method. 5 refs., 4 figs., 8 tabs.

01 COAL, LIGNITE, AND PEAT↗

Accuracy of ghost rotationally invariant slave-boson and dynamical mean field theory as a function of the impurity-model bath size

Here, we compare the accuracy of the ghost rotationally invariant slave-boson (g-RISB) theory and dynamical mean field theory (DMFT) on the single-band Hubbard model, as a function of the number of bath sites in the embedding impurity Hamiltonian. Our benchmark calculations confirm that the accuracy of g-RISB can be systematically improved by increasing the number of bath sites, similar to DMFT. With a few bath sites, we observe that g-RISB is systematically more accurate than DMFT for the ground-state observables. On the other hand, the relative accuracy of these methods is generally comparable for the quasiparticle weight and the spectral function. As expected, we observe that g-RISB satisfies the variational principle in infinite dimensions, as the total energy decreases monotonically towards the exact value as a function of the number of bath sites, suggesting that the g-RISB wave function may approach the exact ground state in infinite dimensions. Our results suggest that the g-RISB is a promising method for first-principles simulations of strongly correlated matter, which can capture the behavior of both static and dynamical observables, at a relatively low computational cost.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Insights on the Alumina–Water Interface Structure by Direct Comparison of Density Functional Simulations with X-ray Reflectivity

Density functional theory molecular dynamics (DFT-MD) simulations are frequently used to predict the interfacial structures and dynamical processes at solid-water interfaces in efforts to gain a deeper understanding of these systems. However, the accuracy of these predictions of interfacial structure has not been rigorously quantified. Here, direct comparisons between large-scale DFT-MD simulations and high-resolution X-ray reflectivity (XR) measurements of the well-defined Al2O3(001)-water interface reveal the relative accuracy of these two methods to describe interfacial structure, a comparison that is enabled by XR’s high sensitivity to atomic-scale displacements. The DFT-MD simulated and XR model-fit structures are qualitatively similar, but XR signals calculated directly from the DFT-MD predictions deviate significantly from the experimental data, revealing discrepancies in these two approaches. Differences in the derived interfacial Al2O3 relaxation profiles of ~0.02 A within the top 5 layers are significant to XR but at the limit of the accuracy of DFT. Further differences are found in the surface hydration layer with a simulated average water layer height ~0.2 A higher than that observed experimentally. This is outside the accuracy of both XR and DFT and is not improved by the inclusion of a phenomenological correction for hydrogen bonding (e.g., Grimme).

74 ATOMIC AND MOLECULAR PHYSICS↗

Machine learning for seismic low-frequency extrapolation

The cycle-skipping problem that plagues full waveform inversion (FWI) can be at least partially mitigated if low frequencies (which encode the kinematics of wave propagation in seismic data) are recorded. However, seismic sources and receivers are band-limited, so seismic data does not generally include signals down to 0 Hz. To improve our ability to solve the seismic inverse problem, one can synthesize this missing low-frequency (LF) content from the recorded high-frequency (HF) data using machine learning (ML) models. Deep learning models such as convolutional neural networks (CNNs) demonstrate impressive ability to perform low frequency extrapolation. However, such models require powerful hardware (GPU machines) and careful training. We assess the extrapolation capabilities of three different ML models that do not require GPU machines, namely, random forest, Gaussian process regression and gradient boosting, on both synthetic and real data. Experimental results on two synthetic data sets (generated from a low velocity lens embedded in a homogeneous medium, and the Marmousi model) demonstrate that FWI applied to the extrapolated data consistently improves inversion accuracy relative to FWI applied to the original data sets that do not contain low frequencies. Application of low-frequency extrapolation to real data from the Northwest Shelf of Australia demonstrates that tree-based ML models such as gradient boosting can outperform CNNs in terms of both accuracy and computational cost on non-GPU architectures.

58 GEOSCIENCES↗

A new paradigm for local-global coupling in whole-core neutron transport.

A new paradigm that increases the efficiency of whole-core neutron transport calculations without lattice homogenization is introduced. Quasi-reflected interface conditions are formulated to partially decouple periodic lattice effects from global flux gradients. The starting point is the finite subelement form of the variational nodal code VARIANT that eliminates fuel-coolant homogenization through the use of heterogeneous nodes. The interface spherical harmonics expansions that couple pin-cell-sized nodes are divided into low-order and high-order terms, and reflected interface conditions are applied to the high-order terms. Combined with an integral transport method within the node, the new approach dramatically reduces both the formation time and the dimensions of the nodal response matrices and leads to sharply reduced memory requirements and computational time. The method is applied to the two-dimensional C5G7 problem, an Organisation for Economic Co-operation and Development/Nuclear Energy Agency pressurized water reactor benchmark containing mixed oxide (MOX) and UO{sub 2} fuel assemblies, as well as to a three-dimensional MOX fuel assembly. Results indicate the new approach results in very little loss of accuracy relative to the corresponding full spherical harmonics expansions while reducing computational times by well over an order of magnitude.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Computationally Predicted High-Throughput Free-Energy Phase Diagrams for the Discovery of Solid-State Hydrogen Storage Reactions

The design of multinary solid-state material systems that undergo reversible phase changes via changes in temperature and pressure provides a potential means of safely storing hydrogen. However, fully mapping the stabilities of known or newly targeted compounds relative to competing phases at reaction conditions has previously required many stringent experiments or computationally demanding calculations of each compound’s change in Gibbs energy with respect to temperature, G(T). Here, we have extended the approach of constructing chemical potential phase diagrams based on ΔG f (T) to enable the analysis of phase stability at non-zero temperatures. We first performed density functional theory calculations to compute the formation enthalpies of binary, ternary, and quaternary compounds within several compositional spaces of current interest for solid-state hydrogen storage. Temperature effects on solid compound stability were then accounted for using our recently introduced machine learned descriptor for the temperature-dependent contribution G δ (T) to the Gibbs energy G(T). From these Gibbs energies, we evaluated each compound’s stability relative to competing compounds over a wide range of conditions and show using chemical potential and composition phase diagrams that the predicted stable phases and H2 release reactions are consistent with experimental observations. This demonstrates that our approach rapidly computes the thermochemistry of hydrogen release reactions for compounds at sufficiently high accuracy relative to experiment to provide a powerful framework for analyzing hydrogen storage materials. This framework based on G(T) enables the accelerated discovery of active materials for a variety of technologies that rely on solid-state reactions involving these materials.

08 HYDROGEN↗

Optimizing the regularization in size-consistent second-order Brillouin-Wigner perturbation theory

Despite its simplicity and relatively low computational cost, second-order Møller-Plesset perturbation theory (MP2) is well-known to overbind noncovalent interactions between polarizable monomers and some organometallic bonds. In such situations, the pairwise-additive correlation energy expression in MP2 is inadequate. Although energy-gap dependent amplitude regularization can substantially improve the accuracy of conventional MP2 in these regimes, the same regularization parameter worsens the accuracy for small molecule thermochemistry and density-dependent properties. Recently, we proposed a repartitioning of Brillouin-Wigner perturbation theory that is size-consistent to second order (BW-s2), and a free parameter ($α$) was set to recover the exact dissociation limit of H 2 in a minimal basis set. Alternatively $α$ can be viewed as a regularization parameter, where each value of $α$ represents a valid variant of BW-s2, which we denote as BW-s2($α$). In this work, we semi-empirically optimize $α$ for noncovalent interactions, thermochemistry, alkane conformational energies, electronic response properties, and transition metal datasets, leading to improvements in accuracy relative to the ab initio parameterization of BW-s2 and MP2. We demonstrate that the optimal $α$ parameter ($α$ = 4) is more transferable across chemical problems than energy-gap-dependent regularization parameters. This is attributable to the fact that the BW-s2($α$) regularization strength depends on all of the information encoded in the t amplitudes rather than just orbital energy differences. While the computational scaling of BW-s2($α$) is iterative $\mathcal{O}$($N^5$), this effective and transferable approach to amplitude regularization is a promising route to incorporate higher-order correlation effects at second-order cost.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Multitask graph neural networks for elastoplastic response prediction in dual-phase polycrystals

Microstructure-sensitive prediction of elastoplastic response remains a recurring bottleneck in multiscale damage and fatigue modeling, where large ensembles of statistically distinct polycrystals are required to quantify variability and extreme-value behavior. In this work, we develop a multitask graph neural network (GNN) surrogate that maps dual-phase ferrite–martensite polycrystal microstructures to Statistical Volume Element (SVE)-level elastoplastic Quantities of Interest (QoIs). Each SVE is represented as a grain-adjacency graph, with node features encoding phase, geometry, and crystallographic orientation, and edge features encoding relative misorientation. A message-passing graph convolution generates node embeddings, which are pooled into a graph representation and passed to a multitask regression head that jointly predicts 10 scalar QoIs and vector-valued stress–strain responses in orthogonal loading directions across multiple martensite volume fractions and SVE sizes. Results show high accuracy for scalar QoIs and strong agreement for full stress–strain trajectories, with population envelopes reproducing both median behavior and finite-SVE variability across compositions and partition scales. A unified model trained on pooled volume-fraction data preserves most within-regime accuracy relative to regime-specific models while also capturing the broader cross-regime variation reflected in the pooled test set. Distributional comparisons further demonstrate that the surrogate preserves heterogeneity under SVE partitioning, enabling statistically consistent block-wise random-field construction for mesoscale analyses. Overall, the proposed grain-graph surrogate provides a practical pathway to accelerate ensemble-based studies of SVE-level constitutive variability in dual-phase polycrystals.

Crystal plasticity↗

Assessment of the accuracy of coupled cluster perturbation theory for open-shell systems. I. Triples expansions

The accuracy at which total energies of open-shell atoms and organic radicals may be calculated is assessed for selected coupled cluster perturbative triples expansions, all of which augment the coupled cluster singles and doubles (CCSD) energy by a non-iterative correction for the effect of triple excitations. Namely, the second- through sixth-order models of the recently proposed CCSD(T–n) triples series [J. J. Eriksen et al., J. Chem. Phys. 140, 064108 (2014)] are compared to the acclaimed CCSD(T) model for both unrestricted as well as restricted open-shell Hartree-Fock (UHF/ROHF) reference determinants. By comparing UHF- and ROHF-based statistical results for a test set of 18 modest-sized open-shell species with comparable RHF-based results, no behavioral differences are observed for the higher-order models of the CCSD(T–n) series in their correlated descriptions of closed- and open-shell species. In particular, we find that the convergence rate throughout the series towards the coupled cluster singles, doubles, and triples (CCSDT) solution is identical for the two cases. For the CCSD(T) model, on the other hand, not only its numerical consistency, but also its established, yet fortuitous cancellation of errors breaks down in the transition from closed- to open-shell systems. The higher-order CCSD(T–n) models (orders n > 3) thus offer a consistent and significant improvement in accuracy relative to CCSDT over the CCSD(T) model, equally for RHF, UHF, and ROHF reference determinants, albeit at an increased computational cost.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Remote Distributed Vibration Sensing Through Opaque Media Using Permanent Magnets

Vibration sensing is critical for a variety of applications from structural fatigue monitoring to understanding the modes of airplane wings. In particular, remote sensing techniques are needed for measuring the vibrations of multiple points simultaneously, assessing vibrations inside opaque metal vessels, and sensing through smoke clouds and other optically challenging environments. Here, in this paper, we propose a method which measures high-frequency displacements remotely using changes in the magnetic field generated by permanent magnets. We leverage the unique nature of vibration tracking and use a calibrated local model technique developed specifically to improve the frequency-domain estimation accuracy. The results show that two-dimensional local models surpass the dipole model in tracking high-frequency motions. A theoretical basis for understanding the effects of electronic noise and error due to correlated variables is generated in order to predict the performance of experiments prior to implementation. Simultaneous measurements of up to three independent vibrating components are shown. The relative accuracy of the magnet-based displacement tracking with respect to the video tracking ranges from 40 to 190 μm when the maximum displacements approach ±5 mm and when sensor-to-magnet distances vary from 25 to 36 mm. Finally, vibration sensing inside an opaque metal vessel and mode shape changes due to damage on an aluminum beam are also studied using the wireless permanent-magnet vibration sensing scheme.

42 ENGINEERING↗

U-Pu and Ba-Cs isotopic measurements on Trinitite by laser ablation sampling on the Neoma MC-ICP-MS

In this study we present the results of combined U-Pu and Ba-Cs isotope measurements obtained by laser ablation (LA) sampling of two glassy debris fragments (‘Trinitite’) from the world's first atomic bomb detonation conducted in New Mexico on July 16, 1945. Our primary goal in conducting these measurements was to understand whether examination of the U-Pu and Ba-Cs systematics by direct sampling (e.g. without any chemical separation or purification prior to isotope ratio measurement) could yield meaningful information that would differentiate the Trinitite fragments from glassy material lacking a nuclear fission signature. These measurements were conducted on a ThermoFisher Scientific Neoma multi collector – inductively coupled plasma – mass spectrometer (MC-ICP-MS), which is a relatively new MC-ICP-MS platform, so we also examine the behavior of these isotope systems in standards sampled in solution and via LA. Unsurprisingly, the measurements made on purified solutions of the U, Pu, and Ba isotopic standards produce high precision isotope ratios. Furthermore, this extends to the U-Pu measurements made by LA sampling, with the expected degradation in precision and accuracy related to matrix effects and signal intensity fluctuation. However, the Ba-Cs data acquired by LA is of low precision across all of the matrices examined and bears evidence of complex mass fractionation that will require further investigation to resolve. In total, our results indicate that the observed U-Pu isotope data are of sufficient quality to accurately constrain the U and Pu isotopic composition of glass containing sub-ppm levels of these elements which in turn could be used to differentiate glass containing anthropogenic fission products from natural glass whereas the Ba-Cs LA data cannot be used for this purpose until further methodological refinement is performed.

Ba-Cs↗

Evaluating the accuracy of common γ-Al 2 O 3 structure models by selected area electron diffraction from high-quality crystalline γ-Al 2 O 3

Single crystal and textured polycrystalline γ-Al 2 O 3 thin films were synthesized by oxidation of NiAl(110) in air at 850 °C for 1 and 2 hours, respectively, and used to evaluate the accuracy of two spinel-based and two nonspinel models by comparison of selected-area electron diffraction (SAED). The lattice interplanar distances derived from the polycrystalline SAED pattern most closely matched the cubic spinel γ-Al 2 O 3 model. The single-crystal SAED spot pattern reflected symmetry consistent with both the cubic spinel and tetragonal nonspinel models, yet, the Al cation distribution better matched the cubic spinel model based on the relative intensities of diffraction spots. Our work indicates that the traditional cubic spinel model is a more accurate model of γ-Al 2 O 3 than the other models considered. Furthermore, the spinel-based monoclinic model is more accurate than the monoclinic nonspinel model. The understanding of the relative accuracy of the different models is key for simulating γ-Al 2 O 3 containing systems and is of general interest for the metal oxide and ceramic communities.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Depth-resolved registration of transesophageal echo to x-ray fluoroscopy using an inverse geometry fluoroscopy system

Purpose: Image registration between standard x-ray fluoroscopy and transesophageal echocardiography (TEE) has recently been proposed. Scanning-beam digital x-ray (SBDX) is an inverse geometry fluoroscopy system designed for cardiac procedures. This study presents a method for 3D registration of SBDX and TEE images based on the tomosynthesis and 3D tracking capabilities of SBDX. Methods: The registration algorithm utilizes the stack of tomosynthetic planes produced by the SBDX system to estimate the physical 3D coordinates of salient key-points on the TEE probe. The key-points are used to arrive at an initial estimate of the probe pose, which is then refined using a 2D/3D registration method adapted for inverse geometry fluoroscopy. A phantom study was conducted to evaluate probe pose estimation accuracy relative to the ground truth, as defined by a set of coregistered fiducial markers. This experiment was conducted with varying probe poses and levels of signal difference-to-noise ratio (SDNR). Additional phantom and in vivo studies were performed to evaluate the correspondence of catheter tip positions in TEE and x-ray images following registration of the two modalities. Results: Target registration error (TRE) was used to characterize both pose estimation and registration accuracy. In the study of pose estimation accuracy, successful pose estimates (3D TRE < 5.0 mm) were obtained in 97% of cases when the SDNR was 5.9 or higher in seven out of eight poses. Under these conditions, 3D TRE was 2.32 ± 1.88 mm, and 2D (projection) TRE was 1.61 ± 1.36 mm. Probe localization error along the source-detector axis was 0.87 ± 1.31 mm. For the in vivo experiments, mean 3D TRE ranged from 2.6 to 4.6 mm and mean 2D TRE ranged from 1.1 to 1.6 mm. Anatomy extracted from the echo images appeared well aligned when projected onto the SBDX images. Conclusions: Full 6 DOF image registration between SBDX and TEE is feasible and accurate to within 5 mm. Future studies will focus on real-time implementation and application-specific analysis.

60 APPLIED LIFE SCIENCES↗

The generalized liquid drop model alpha-decay formula: Predictability analysis and superheavy element alpha half-lives

The predictive accuracy of the generalized liquid drop model (GLDM) formula for alpha-decay half-lives has been investigated in a detailed manner and a variant of the formula with improved coefficients is proposed. The method employs the experimental alpha half-lives of the well-known alpha standards to obtain the coefficients of the analytical formula using the experimental Q{sub {alpha}} values (the DSR-E formula), as well as the finite range droplet model (FRDM) derived Q{sub {alpha}} values (the FRDM-FRDM formula). The predictive accuracy of these formulae was checked against the experimental alpha half-lives of an independent set of nuclei (TEST) that span approximately the same Z, A region as the standards and possess reliable alpha spectroscopic data, and were found to yield good results for the DSR-E formula but not for the FRDM-FRDM formula. The two formulae were used to obtain the alpha half-lives of superheavy elements (SHE) and heavy nuclides where the relative accuracy was found to be markedly improved for the FRDM-FRDM formula, which corroborates the appropriateness of the FRDM masses and the GLDM prescription for high Z, A nuclides. Further improvement resulted, especially for the FRDM-FRDM formula, after a simple linear optimization over the calculated and experimental half-lives of TEST was used to re-calculate the half-lives of the SHE and heavy nuclides. The advantage of this optimization was that it required no re-calculation of the coefficients of the basic DSR-E or FRDM-FRDM formulae. The half-lives for 324 medium-mass to superheavy alpha decaying nuclides, calculated using these formulae and the comparison with experimental half-lives, are presented.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A surrogate-model-based approach for estimating the first and second-order moments of offshore wind power

Power curve, the functional relationship that governs the process of converting a set of weather variables experienced by a wind turbine into electric power, is widely used in the wind industry to estimate power output for planning and operational purposes. Existing methods for power curve estimation have three main limitations: (i) they mostly rely on wind speed as the sole input, thus ignoring the secondary, yet possibly significant effects of other environmental factors, (ii) they largely overlook the complex marine environment in which offshore turbines operate, potentially compromising their value in offshore wind energy applications, and (ii) they solely focus on the first-order properties of wind power, with little (or null) information about the variation around the mean behavior, which is important for ensuring reliable grid integration, asset health monitoring, and energy storage, among others. In light of that, this study investigates the impact of several wind-and wave-related factors on offshore wind power variability, with the ultimate goal of accurately predicting its first two moments. Further, our approach couples OpenFAST—a multi-physics wind turbine simulator—with Gaussian Process (GP) regression to reveal the underlying relationships governing offshore weather-to-power conversion. We first find that a multi-input power curve which captures the combined impact of wind speed, direction, and air density, can provide double-digit improvements, in terms of prediction accuracy, relative to univariate methods which rely on wind speed as the sole explanatory variable (e.g. the standard method of bins). Wave-related variables are found not important for predicting the average power output, but interestingly, appear to be extremely relevant in describing the fluctuation of the offshore power around its mean. Tested on real-world data collected at the New York/New Jersey bight, our proposed multi-input models demonstrate a high explanatory power in predicting the first two moments of offshore wind generation, testifying their potential value to the offshore wind industry.

17 WIND ENERGY↗