Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Reflectometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Side-viewing detector for a vacuum ultraviolet reflectometer.

The problem of detector response, which arises in the application of the reflectance vs angle of incidence method to the determination of optical constants in the vacuum UV spectral region is discussed. The analysis is performed for the side-viewing 1P21 detector sensitized with sodium salycilate. To take advantage of the wide selection photomultipliers available in the end-on configuration, a scheme for converting the end-on types to a side viewing geometry with a response uniform over several degrees of detector rotation is developed. It consists of a 32-mm diam spherical collector, located at the end of a cylindrical photomultiplier holder, with 12-mm entrance and viewing ports and a position for the sensitized screen also 12-mm in diameter.-

Osantowski, J. F.↗

Vacuum-ultraviolet reflectometer

Baffle, three-blade chopper, and split spherical mirror transmit alternating dual beam into integrating sphere. Alternating reference and sample beams are detected by high gain photomultiplier and modified logarithmic ratiometer. Device is useful in fusion research, high power laser work, and spectrometer or monochromator construction.

Allen, T. H.↗

Design study of an entry probe spectro-reflectometer

A wind tunnel was built to simulate the rapid movement of an entry probe through the Jupiter atmosphere. Wind speeds range from 1 to 50 meters per second in a closed system. Wind velocity and temperature probes as well as a cryogenically cooled cold finger can be placed in the 6 inch diameter viewing section. The initial testing of the wind tunnel involved running sectional profiles through the observation port of air currents of 0.1 to 3.0 atmosphere. The velocity profile was very uniform throughout the cross section of the experimental port, with the exception of the wall effects. The deposition of cooled volatiles using the wind tunnel was not performed. However, measurements of the deposition of H2O ice on a cryogenically cooled thickness modulator were made under ambient conditions, namely room temperature and pressure. In the Frost Depositon Test Facility, ice deposition was measured at thicknesses of about a half millimeter and frost was produced whose thickness reflectivity could easily be measured by reflectance spectroscopy.

Sill, G. T.↗

Effects of low Earth orbit environment on the Long Duration Exposure Facility thermal control coatings

One of the benefits of the Long Duration Exposure Facility (LDEF) was the opportunity to study the before and after effects of low earth orbit space environment on the spacecraft thermal control coatings. Since the LDEF's thermal control was totally passive by design, the selection of the external surface absorptivity to emissivity ratio (alpha/epsilon) and the ability for the coating to retain the alpha/epsilon over time was an important consideration in the thermal design of the LDEF. The primary surface coating chosen for the LDEF structure was clear chromic anodized aluminum with an average design alpha/epsilon of 0.32/0.16. External surface absorptivity (alpha) and emissivity (epsilon) were measured on all intercostals, longerons, tray mounting flanges, thermal control panels, and a limited number of experiment surface coatings after the experiment trays were removed from the LDEF structure. All surface alpha/epsilon measurements were made using portable hand held infrared and solar spectrum reflectometers. The absorptivity measurements were taken with a Devices and Services SSR-ER version 5.0 solar spectra reflectometer which has a stated uncertainty of +/- 0.01, and all normal emissivity measurements were made using the Gier Dunkle DB-100 infrared reflectometer also with a stated uncertainty of +/- 0.01. Both instruments were calibrated in the laboratory by LaRC instrumentation personnel before being used in the field at KSC. A combined total of 733 measurements were taken on the anodized aluminum hardware which included the structure (intercostals, longerons, and center ring), earth and space end thermal control panels, and experiment tray mounting flanges. The facility thermal control coatings measured in this survey cover 33 percent of the total exposed LDEF surface area. To correlate low earth orbit environmental effects on the anodized coatings, measurements were taken in both exposed and unexposed surfaces and compared to quality assurance (QA) measurements taken on the new surfaces at the time of hardware fabrication in 1978. The results of investigation are presented.

Sampair, Thomas R.↗

Methods to Determine the Deformation of the IRVE Hypersonic Inflatable Aerodynamic Decelerator

Small resonant targets used in conjunction with a microwave reflectometer to determine the deformation of the Hypersonic Inflatable Aerodynamic Decelerator (HIAD) during reentry are investigated. The reflectometer measures the distance to the targets and from this the HIAD deformation is determined. The HIAD is used by the Inflatable Reentry Vehicle Experiment (IRVE) which investigates the use of inflatable heat shields for atmospheric reentry. After several different microwave reflectometer systems were analyzed and compared it was determined that the most desirable for this application is the Frequency Doubling Target method.

Young, William R.↗

Continuous liquid level measurements with time domain reflectometry

A time domain reflectometer is considered as a closed loop, one-dimensional radar system. Applying the principle of time domain reflectometry to the detection of cryogenic liquid levels, measurements on the order of + or - 0. 3% of total liquid level probe length are possible. The time domain reflectometer liquid level measurement is independent of liquid density variations and is simple to calibrate and operate. Construction of the liquid level sensing probe is described.

Cruz, J. E.↗

Specular reflectance of aqueous solutions.

Description of two laboratory instruments for measuring the specular reflectance of aqueous solutions. The instruments are an organic-dye-laser spectrophotometer for the 360- to 650-nm wavelength region and a reflectometer accessory for a Perkin-Elmer E-system spectrophotometer which will operate in the 0.2- to 20-micron wavelength region. The reflectometer accessory has been used to measure the relative infrared specular reflectance in limited spectral regions for aqueous solutions of NaCl, K2SO4, ZnSO4, (NH4)2SO4, and NH4H2PO4 with radiant flux incident at about 70 deg and polarized perpendicular to the plane of incidence. The laser spectrometer has been used to measure the absolute reflectance of aqueous solutions of NaCl in the wavelength region from 575 to 610 nm for light incident at angles of about 60, 65, and 70 deg and polarized parallel to the plane of incidence.

Querry, M. R.↗

Study on the effect of contamination on the performance of X-ray telescopes

Modifications were made to the X-ray reflectometer located at the Space Sciences Laboratory, Marshall Space Flight Center. One was an automatic drive for the Large Micrometer Head. This system, interfaced with the Hewlett Packard Computer System, is used to record data and provides the X-ray reflectometer with an automated data-taking capability. Using this system, a complete scatter curve can be obtained automatically. Previously, it was necessary to manually reset the system after recording for each data point in the scatter curve. The second modification provided an externally controlled electrical drive to move the microfocus X-ray source along its axis. With this modification, one can translate the X-ray source while it is operating to locate the position providing maximum count rate.

Neal, W. R.↗

Optical measurements on contaminated surfaces

A bidirectional reflectometer system was developed for in situ measurements of the changes in spectral reflectance of surfaces contaminated with films of organic materials. The system permits experiments with films of controlled thickness in an environment that simulates the thermal, radiation, and vacuum conditions of space. The mechanical and optical construction of the reflectometer are discussed in detail, and actual data curves are used to illustrate its operation and performance.

Bonham, T. E.↗

Development of Surfaces Optically Suitable for Flat Solar Panels

Three areas of research in the development of flat solar panels are described. (1) A reflectometer which can separately evaluate the spectral and diffuse reflectivities of surfaces was developed. The reflectometer has a phase locked detection system. (2) A coating composed of strongly bound copper oxide that is formed by an etching process performed on an aluminum alloy with high copper content was also developed. Because of this one step fabrication process, fabrication costs are expected to be small. (3) A literature search was conducted and conclusions on the required optical properties of flat plate solar collectors are presented.

Desmet, D.↗