Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Reference Values”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Low Level Calibration of Liquid Scintillation Counting

Liquid Scintillation Counting (LSC) is an analytical laboratory method that quantifies the concentrations of alpha and beta emitting isotopes. The LSC method can be utilized for the detection of tritium, both environmentally and at nuclear facilities. Most LSC samples are aqueous-based and prepared as a radioactive sample dissolved or suspended in a high efficiency scintillation cocktail that converts radioactive energy into light pulses. When placed in counting vials, the liquid scintillation cocktail allows for optical coupling in which energy is released from the samples radioactive decay, and transferred to the scintillator. That energy is then absorbed to produce excited electrons that fall back to their ground-state and emit a pulse of light that is detected by the liquid scintillation analyzers photomultiplier tubes. Quench is a signal attenuation due to physical, chemical, or color interferences. To compensate for quench, quench standards of a known concentration are implemented at increasing increments of quench per vial to create a quench curve. Quench standards can be purchased pre-made or customized from the manufacturer, however, there are several issues that arise from purchasing the pre-made quench standards. The main issues with ordering pre-made quench standards is that they use higher count values, between 30,000 and 250,000 disintegrations per minute (dpm) of tritium per vial and only come in glass vials. Using higher counting standards in glass vials makes it hard to see lower concentrations in plastic vials. Additionally, when using higher energy standards the accuracy of the calibration readings tend to be lower. On the other hand, making a set of quench standards in-house allows for the customization of the dpm concentration to roughly 1,500-3,000 and preparation in plastic vials. This allows for lower activity readings that results in closer precision of the samples' true concentration. Technical Objectives: Create a quench curve and calibrate the LSA for tritium. Verify the calibration of the quench curve prior to cross sample runs. Check calibration against Quality Control (QC) reference value. Conclusion: a tritium quench curve calibration was performed using a scintillation cocktail with ultima gold (AB and AB/F), acetone (only with AB), and water (only with AB/F). By performing the tritium quench curve calibration, the counting efficiency was correlated to various levels of quench. Calibration checks with quality control standards were also performed to verify that the calibration was correct. The observed results provided acceptable values that matched the quality control standard reference values with an acceptable uncertainty. The next step will be fine tuning and cross comparison checks with legacy instrumentation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ice-Accretion Scaling Using Water-Film Thickness Parameters

Studies were performed at INTA in Spain to determine water-film thickness on a stagnation-point probe inserted in a simulated cloud. The measurements were correlated with non-dimensional parameters describing the flow and the cloud conditions. Icing scaling tests in the NASA Glenn Icing Research Tunnel were then conducted using the Ruff scaling method with the scale velocity found by matching scale and reference values of either the INTA non-dimensional water-film thickness or a Weber number based on that film thickness. For comparison, tests were also performed using the constant drop-size Weber number and the average-velocity methods. The reference and scale models were both aluminum, 61-cm-span, NACA 0012 airfoil sections at 0 deg. AOA. The reference had a 53-cm-chord and the scale, 27 cm (1/2 size). Both models were mounted vertically in the center of the IRT test section. Tests covered a freezing fraction range of 0.28 to 1.0. Rime ice (n = 1.0) tests showed the consistency of the IRT calibration over a range of velocities. At a freezing fraction of 0.76, there was no significant difference in the scale ice shapes produced by the different methods. For freezing fractions of 0.40, 0.52 and 0.61, somewhat better agreement with the reference horn angles was typically achieved with the average-velocity and constant-film thickness methods than when either of the two Weber numbers was matched to the reference value. At a freezing fraction of 0.28, the four methods were judged equal in providing simulations of the reference shape.

Anderson, David N.↗

A set of 4D pediatric XCAT reference phantoms for multimodality research

Purpose: The authors previously developed an adult population of 4D extended cardiac-torso (XCAT) phantoms for multimodality imaging research. In this work, the authors develop a reference set of 4D pediatric XCAT phantoms consisting of male and female anatomies at ages of newborn, 1, 5, 10, and 15 years. These models will serve as the foundation from which the authors will create a vast population of pediatric phantoms for optimizing pediatric CT imaging protocols. Methods: Each phantom was based on a unique set of CT data from a normal patient obtained from the Duke University database. The datasets were selected to best match the reference values for height and weight for the different ages and genders according to ICRP Publication 89. The major organs and structures were segmented from the CT data and used to create an initial pediatric model defined using nonuniform rational B-spline surfaces. The CT data covered the entire torso and part of the head. To complete the body, the authors manually added on the top of the head and the arms and legs using scaled versions of the XCAT adult models or additional models created from cadaver data. A multichannel large deformation diffeomorphic metric mapping algorithm was then used to calculate the transform from a template XCAT phantom (male or female 50th percentile adult) to the target pediatric model. The transform was applied to the template XCAT to fill in any unsegmented structures within the target phantom and to implement the 4D cardiac and respiratory models in the new anatomy. The masses of the organs in each phantom were matched to the reference values given in ICRP Publication 89. The new reference models were checked for anatomical accuracy via visual inspection. Results: The authors created a set of ten pediatric reference phantoms that have the same level of detail and functionality as the original XCAT phantom adults. Each consists of thousands of anatomical structures and includes parameterized models for the cardiac and respiratory motions. Based on patient data, the phantoms capture the anatomic variations of childhood, such as the development of bone in the skull, pelvis, and long bones, and the growth of the vertebrae and organs. The phantoms can be combined with existing simulation packages to generate realistic pediatric imaging data from different modalities. Conclusions: The development of patient-derived pediatric computational phantoms is useful in providing variable anatomies for simulation. Future work will expand this ten-phantom base to a host of pediatric phantoms representative of the public at large. This can provide a means to evaluate and improve pediatric imaging devices and to optimize CT protocols in terms of image quality and radiation dose.

61 RADIATION PROTECTION AND DOSIMETRY↗

Regional surface fluxes from satellite-derived surface temperatures (AVHRR) and radiosonde profiles

Radiometric surface temperatures, derived from measurements by the AVHRR instrument aboard the NOAA-9 and the NOAA-11 polar orbiting satellites, were used in combination with wind velocity and temperature profiles measured by radiosondes, to calculate surface fluxes of sensible heat. The measurements were made during FIFE, the First ISLSCP (International Satellite Land Surface Climatology Project) Field Experiment, in a hilly tall grass prairie area of northeastern Kansas. The method of calculation was based on turbulent similarity formulations for the atmospheric boundary layer. Good agreement (r = 0.7) was obtained with reference values of sensible heat flux, taken as arithmetric means of measurements with the Bowen ratio method at six ground stations. The values of evaporation (latent heat fluxes), derived from these sensible heat fluxes by means of the energy budget, were also in good agreement (r = 0.94) with the corresponding reference values from the ground stations.

Brutsaert, Wilfried↗

Computing and Representing Sea Ice Trends: Toward a Community Consensus

Estimates of the recent decline in Arctic Ocean summer sea ice extent can vary due to differences in sea ice data sources, in the number of years used to compute the trend, and in the start and end years used in the trend computation. Compounding such differences, estimates of the relative decline in sea ice cover (given in percent change per decade) can further vary due to the choice of reference value (the initial point of the trend line, a climatological baseline, etc.). Further adding to the confusion, very often when relative trends are reported in research papers, the reference values used are not specified or made clear. This can lead to confusion when trend studies are cited in the press and public reports.

trend↗

European Measurement Comparisons of Environmental Radioactivity

The scheme of European measurement comparisons to verify radioactivity monitoring in the European Union is briefly explained. After a review of comparisons conducted during the years 1990, the approach of IRMM organising these comparisons since 2003 is presented. IRMM is providing comparison samples with a reference value traceable to the SI units and which is fully documented to all participants and national authorities after completion of the comparison. The sample preparation and determination of traceable reference values at IRMM, the sample treatment and measurement in the participating laboratories, as well as the evaluation of comparison results are described in some detail using the example of an air filter comparison. The results of a comparison to determine metabolised {sup 40}K, {sup 90}Sr and {sup 137}Cs in milk powder are presented as well. The necessary improvements in the estimation of measurement uncertainty by the participating laboratories are discussed. The performance of individual laboratories which have participated in at least four comparison exercises over the years is studied in terms of observable trends.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Single particle – MC-ICP-MS for isotopic analysis of uranium particles

Single particle – multi-collector – inductively coupled plasma – mass spectrometry (SP-MC-ICP-MS) was employed to measure a suspension of 1 µm U3O8 particles (∼1.3 pg total U/particle) to determine their individual isotopic compositions of 234U/238U, 235U/238U, and 236U/238U. The effects of different detector combinations for 235U and 238U, including secondary electron multipliers (SEM) and Faraday detectors (1011 and 1013 Ω amplifiers), were explored for accuracy and precision optimization on the observed 235U/238U. The minor isotopic ratios (i.e., 234U/238U and 236U/238U) were analyzed such that the 234U and 236U were monitored on SEM detectors and the 238U was monitored on a Faraday (1011 Ω) detector. Various integration times (5, 10, 25, and 50 ms) were investigated in all detector configurations to gain a better understanding of their impact on sensitivity, accuracy, and precision. For 235U/238U ratios of 1 µm U3O8 particles, a dual Faraday detector measurement with 1011 Ω was the optimal choice; measurement of 1021 particles yielded an average 235U/238U ratio of 0.00170 (14), a −1.8% relative difference (% RD) from the reference value. The minor isotopic compositions were determined to be 0.0000070 (14) and 0.0000758 (48) for the 234U/238U and 236U/238U, respectively. These measurements correspond to <8% and <1% RD from their reference value for the 234U/238U and 236U/238U, respectively. SP-MC-ICP-MS was also able to provide insight into measurement sensitivity. In these individual particles, merely 15 and 165 atto-grams (ag) of 234U and 236U were present (calculated). Initial limits of detection for SP-MC-ICP-MS were determined to be ∼1.0 ag (when measured via SEM detectors). This valuable approach is applicable to areas including nuclear forensics, nuclear safeguards, and geochemical analysis, which require high-precision measurements of uranium within micron-sized particles.

Manard, Benjamin [ORNL] (ORCID:0000000207400627)↗

Self-interaction-free electric dipole polarizabilities for atoms and their ions using the Fermi-Löwdin self-interaction correction

The static electric dipole polarizability of a system is a measure of the binding of its electrons. In density functional theory calculations, this binding is weakened by the presence of unphysical self-interaction in the density functional approximation (DFA), leading to overestimates of polarizabilities. In this work, to investigate this systematically we compare polarizabilities for the atoms from H to Ar and their anions and cations calculated in several DFAs and the corresponding self-interaction-corrected (SIC) DFAs with experiment and with high-level quantum chemistry reference values. The SIC results are obtained using the Fermi-Löwdin orbital self-interaction correction (FLO-SIC) method. Removing self-interaction generally leads to smaller polarizabilities that agree significantly better with reference values. In conclusion, we find that FLO-SIC improves the performance of the local spin density approximation and the generalized gradient approximation (GGA) for polarizabilities to a quality that is comparable to so-called rung 4 functionals, but slightly degrades the performance of the strongly constrained and appropriately normed meta-GGA functional.

74 ATOMIC AND MOLECULAR PHYSICS↗

Calibration of helical tomotherapy machine using EPR/alanine dosimetry

Purpose: Current codes of practice for clinical reference dosimetry of high-energy photon beams in conventional radiotherapy recommend using a 10x10 cm{sup 2} square field, with the detector at a reference depth of 10 cm in water and 100 cm source to surface distance (SSD) (AAPM TG-51) or 100 cm source-to-axis distance (SAD) (IAEA TRS-398). However, the maximum field size of a helical tomotherapy (HT) machine is 40x5 cm{sup 2} defined at 85 cm SAD. These nonstandard conditions prevent a direct implementation of these protocols. The purpose of this study is twofold: To check the absorbed dose in water and dose rate calibration of a tomotherapy unit as well as the accuracy of the tomotherapy treatment planning system (TPS) calculations for a specific test case. Method: Both topics are based on the use of electron paramagnetic resonance (EPR) using alanine as transfer dosimeter between the Laboratoire National Henri Becquerel (LNHB) {sup 60}Co-{gamma}-ray reference beam and the Institut Curie's HT beam. Irradiations performed in the LNHB reference {sup 60}Co-{gamma}-ray beam allowed setting up the calibration method, which was then implemented and tested at the LNHB 6 MV linac x-ray beam, resulting in a deviation of 1.6% (at a 1% standard uncertainty) relative to the reference value determined with the standard IAEA TRS-398 protocol. Results: HT beam dose rate estimation shows a difference of 2% with the value stated by the manufacturer at a 2% standard uncertainty. A 4% deviation between measured dose and the calculation from the tomotherapy TPS was found. The latter was originated by an inadequate representation of the phantom CT-scan values and, consequently, mass densities within the phantom. This difference has been explained by the mass density values given by the CT-scan and used by the TPS which were not the true ones. Once corrected using Monte Carlo N-Particle simulations to validate the accuracy of this process, the difference between corrected TPS calculations and alanine measured dose values was then found to be around 2% (with 2% standard uncertainty on TPS doses and 1.5% standard uncertainty on EPR measurements). Conclusion: Beam dose rate estimation results were found to be in good agreement with the reference value given by the manufacturer at 2% standard uncertainty. Moreover, the dose determination method was set up with a deviation around 2% (at a 2% standard uncertainty).

61 RADIATION PROTECTION AND DOSIMETRY↗

Deployment of an Advanced Electrocardiographic Analysis (A-ECG) to Detect Cardiovascular Risk in Career Firefighters

INTRODUCTION Sudden cardiac death is the leading cause of line of duty death among firefighters, accounting for approximately 45% of fatalities annually. Firefighters perform strenuous muscular work while wearing heavy, encapsulating personal protective equipment in high ambient temperatures, under chaotic and emotionally stressful conditions. These factors can precipitate sudden cardiac events like myocardial infarction, serious dysrhythmias, or cerebrovascular accidents in firefighters with underlying cardiovascular disease. Screening for cardiovascular risk factors is recommended but not always followed in this population. PHASER is a project charged with identifying and prioritizing risk factors in emergency responders. We have deployed an advanced ECG (A-ECG) system developed at NASA for improved sensitivity and specificity in the detection of cardiac risk. METHODS Forty-four professional firefighters were recruited to perform comprehensive baseline assessments including tests of aerobic performance and laboratory tests for fasting lipid profiles and glucose. Heart rate and conventional 12-lead ECG were obtained at rest and during incremental treadmill exercise testing (XT). In addition, a 5-min resting 12-lead A-ECG was obtained in a subset of firefighters (n=18) and transmitted over a secure networked system to a physician collaborator at NASA for advanced-ECG analysis. This A-ECG system has been proven, using myocardial perfusion and other imaging, to accurately identify a number of cardiac pathologies including coronary artery disease (CAD), left ventricular hypertrophy, hypertrophic cardiomyopathy, non-ischemic cardiomyopathy, and ischemic cardiomyopathy. RESULTS Subjects mean (SD) age was 43 (8) years, weight 91 (13) kg, and BMI of 28 (3) kg/square meter. Maximum oxygen uptake (VO2max) was 39 (9) ml/kg/min. This compares with the 45th %ile in healthy reference values and a recommended standard of 42 ml/kg/min for firefighters. The metabolic threshold (VO2Theta) above which lactate accumulates was 23 (8) ml/kg/min. The chronotropic index, a measure of cardiovascular strain during XT was 35 (8) /L compared with reference values for men of 40 /L. Total cholesterol, LDL-C and HDL-C were 202 (34),126 (29), and 55 (15) mg/dl, respectively. Fifty-one percent of subjects had .3 cardiovascular risk factors, 2 subjects had resting hypertension (BP.140/90), and 23 had pre-hypertension (.120/80 but <140/90). Seven had exaggerated exercise induced hypertension but only one had ST depression on XT ECG, at least one positive A-ECG score for CAD, and documented CAD based on cardiology referral. While all other subjects, including those with fewer risk factors, higher aerobic fitness, and normal exercise ECGs, were classified as healthy by A-ECG, there was no trend for association between risk factors and any of 20 A-ECG parameters in the grouped data. CONCLUSIONS A-ECG screening correctly identified the individual with CAD although there was no trend for A-ECG parameters to distinguish those with elevated BP or multiple risk factors but normal XT ECG. We have demonstrated that a new technology, advanced-ECG, can be introduced for remote firefighter risk assessment. This simple, time and cost-effective approach to risk identification that can be acquired remotely and transmitted securely can detect individuals potentially at risk for line-of-duty death. Additional research is needed to further document its value.

Dolezal, B. A.↗

Assessment of two hybrid van der Waals density functionals for covalent and non-covalent binding of molecules

Two hybrid van der Waals density functionals (vdW-DFs) are developed using 25% Fock exchange with (i) the consistent-exchange vdW-DF-cx functional [K. Berland and P. Hyldgaard, Phys. Rev. B 89, 035412 (2014)] and (ii) with the vdW-DF2 functional [K. Lee et al., Phys. Rev. B 82, 081101 (2010)]. The ability to describe covalent and non-covalent binding properties of molecules is assessed. For properties related to covalent binding, atomization energies (G2-1 set), molecular reaction energies (G2RC set), and ionization energies (G21IP set) are benchmarked against experimental reference values. We find that hybrid-vdW-DF-cx yields results that are rather similar to those of the standard non-empirical hybrid PBE0 [C. Adamo and V. Barone, J. Chem. Phys. 110, 6158 (1999)], with mean average deviations (MADs) of 4.9 and 5.0 kcal/mol for the G2-1 set, respectively. In this comparison, experimental reference values are used, back corrected by wavefunction-based quantum-chemistry calculations of zero-point energies. Hybrid vdW-DF2 follows somewhat different trends, showing on average significantly larger deviations from the reference energies, with a MAD of 14.5 kcal/mol for the G2-1 set. Non-covalent binding properties of molecules are assessed using the S22 benchmark set of non-covalently bonded dimers and the X40 set of dimers of small halogenated molecules, using wavefunction-based quantum chemistry results as references. For the S22 set, hybrid-vdW-DF-cx performs better than standard vdW-DF-cx for the mostly hydrogen-bonded systems, with MAD dropping from 0.6 to 0.3 kcal/mol, but worse for purely dispersion-bonded systems, with MAD increasing from 0.2 to 0.6 kcal/mol. Hybrid-vdW-DF2 offers a slight improvement over standard vdW-DF2. Similar trends are found for the X40 set, with hybrid-vdW-DF-cx performing particularly well for binding energies involving the strongly polar hydrogen halides, but poorly for systems with tiny binding energies. Our study of the X40 set reveals the potential of mixing Fock exchange with vdW-DF, but also highlights shortcomings of the hybrids constructed here. In conclusion, the solid performance of hybrid-vdW-DF-cx for covalent-bonded systems, as well as the strengths and issues uncovered for non-covalently bonded systems, makes this study a good starting point for developing even more accurate hybrid vdW-DFs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Apparatus and method for measuring relative phase of signals in a multiple-echo system

An apparatus and method for measuring the relative phase of echo signals in a multiple-echo system. A signal generator generates an exciting tone burst and subsequent tone bursts delayed in phase from the exciting tone burst. The exciting tone burst is gated into a transducer coupled to the multiple-echo system. Each subsequent tone burst is converted into a series of pulses. Each pulse triggers a sample/hold circuit to sample each echo signal. The samples of the echo signal are averaged and then compared to a reference value. The signal generator is controlled to vary the subsequent tone burst phase delay to determine for each echo signal a subsequent tone burst phase delay that causes the average of the samples of the echo signal to be substantially equal to the reference value wherein the determined subsequent tone burst phase delay is the phase delay of the echo signal with respect to the exciting tone burst. The control circuit then determines the difference in phase delay between echo signals to determine the relative phase delay of the echo signals.

Froggatt, Mark E.↗

The Air Toxics Health Effects Database (ATHED)

The Air Toxics Health Effects Database (ATHED) is currently used by the EPA's Office of Air Quality Planning and Standards (OAQPS) to support risk assessments for the Residual Risk Program. An assessment of the residual risk is required to be performed at a specified time (typically 8years) following the promulgation of a technology-based Maximum Achievable Control Technologies (MACT) standard. The goal of the Residual Risk Program is to assure that the risk that remains after MACT standards are implemented (i.e., the 'residual risk') is acceptable, and if not, to propose additional regulations to mitigate those risks. ATHED maintains all available reference values for each chemical as separate data records, and includes values for all exposure durations (acute, short-term, subchronic and chronic). These values are used as benchmarks to determine acceptable exposure levels to the hazardous air pollutants (HAPs) listed in Section 112 of the Clean Air Act. ATHED also provides useful background information on the uncertainty and/or modifying factors that were applied in the derivation of each reference value, as well as the point of departure and the critical study/studies. To facilitate comparisons across durations for a specific chemical, ATHED data can be graphically presented.

60 APPLIED LIFE SCIENCES↗

TIME-AVERAGE-BASED METHODS FOR MULTI-ANGULAR SCALE ANALYSIS OF COSMIC-RAY DATA

Over the past decade, a number of experiments dealt with the problem of measuring the arrival direction distribution of cosmic rays, looking for information on the propagation mechanisms and the identification of their sources. Any deviation from the isotropy may be regarded to as a signature of unforeseen or unknown phenomena, mostly if well localized in the sky and occurring at low rigidity. It induced experimenters to search for excesses down to angular scales as narrow as 10 Degree-Sign , disclosing the issue of properly filtering contributions from wider structures. A solution commonly envisaged was based on time-average methods to determine the reference value of cosmic-ray flux. Such techniques are nearly insensitive to signals wider than the time window in use, thus allowing us to focus the analysis on medium- and small-scale signals. Nonetheless, the signal often cannot be excluded in the calculation of the reference value, which induces systematic errors. The use of time-average methods recently revealed important discoveries about the medium-scale cosmic-ray anisotropy, present both in the northern and southern hemispheres. It is known that the excess (or deficit) is observed as less intense than in reality and that fake deficit zones are rendered around true excesses because of the absolute lack of knowledge a priori of which signal is true and which is not. This work is an attempt to critically review the use of time-average-based methods for observing extended features in the cosmic-ray arrival distribution pattern.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Godiva-IV Dosimetry Exercise 2022 Preliminary Results

Integral Experiment Request (IER) 538 is part of a series of dose characterization and nuclear accident dosimetry (NAD) exercises performed under the Department of Energy (DOE) Nuclear Criticality Safety Program (NCSP). This is the second NAD exercise using the Godiva-IV critical assembly and the third NAD exercise overall. The participating laboratories provided their own dosimeters that were mounted on the Lawrence Livermore National Laboratory (LLNL) BOttle Manikin ABsorption (BOMAB) phantoms and aluminum plates. The BOMABs and plates were placed at two, three, and four meters away from the center of Godiva. Alongside the NADs, there was a LLNL Passive Neutron Spectrometer (PNS), Atomic Weapons Establishment (AWE) PNS, and Y-12 Sphere present to measure the neutron dose from Godiva. Two irradiations were conducted to test the NAD performance from each laboratory and assesses their performance to the DOE-STD-1098-2017 part 515 criteria. Neutron and gamma doses were measured prior to this exercise. This work presents a model for the neutron and gamma dose respectively to serve as the reference value. A code written in C/C++/ROOT was used to fit the measured neutron and gamma dose with the new models. It was assumed that the neutron and gamma doses are proportional to the change in temperature of Godiva after a burst irradiation. Uncertainties for the reference values were calculated using error propagation of the model’s parameters. Preliminary results (within twenty-four hours) and final results were compared for each laboratory. On average of all the participating laboratories, 32% of neutron doses and 78% of gamma doses were outside the DOE standards. One laboratory did not report their dose readings and were not included in this average. There is a bias for a lower neutron dose and a higher gamma dose based on the distribution of results. In comparison with the past Godiva-IV NAD exercise, there is an improvement in neutron dose readings by 20%.

BOttle Manikin ABsorption (BOMAB)↗

Comparison of heavy-ion transport simulations: Collision integral with pions and Δ resonances in a box

Simulations by transport codes are indispensable for extracting valuable physical information from heavy-ion collisions. Pion observables such as the π - /π + yield ratio are expected to be sensitive to the symmetry energy at high densities. To evaluate, understand, and reduce the uncertainties in transport-code results originating from different approximations in handling the production of Δ resonances and pions. We compare ten transport codes under controlled conditions for a system confined in a box, with periodic boundary conditions, and initialized with nucleons at saturation density and at a temperature of 60 MeV. The reactions NN↔NΔ and Δ↔Nπ are implemented, but the Pauli blocking and the mean-field potential are deactivated in the present comparison. Thus, these are cascade calculations including pions and Δ resonances. Results are compared to those from the two reference cases of a chemically equilibrated ideal gas mixture and of the rate equation. For the numbers of Δ and π, deviations from the reference values are observed in many codes, and they depend significantly on the size of the time step. These deviations are tied to different ways in ordering the sequence of reactions, such as collisions and decays, that take place in the same time step. Better agreements with the reference values are seen in the reaction rates and the number ratios among the isospin species of Δ and π. Both the reaction rates and the number ratios are, however, affected by the correlations between particle positions, which are absent in the Boltzmann equation, but are induced by the way particle scatterings are treated in many of the transport calculations. The uncertainty in the transport-code predictions of the π - /π + ratio, after letting the existing Δ resonances decay, is found to be within a few percent for the system initialized at n/p=1.5. In conclusion, the uncertainty in the final π - /π + ratio in this simplified case of particles in a box is sufficiently small so that it does not strongly impact constraining the high-density symmetry energy from heavy-ion collisions. Most of the sources of uncertainties have been understood, and individual codes may be further improved in future applications. This investigation will be extended in the future to heavy-ion collisions to ensure the problems identified here remain under control.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The effect of self-interaction error on electrostatic dipoles calculated using density functional theory

Spurious electron self-interaction in density functional approximations (DFAs) can lead to inaccurate predictions of charge transfer in heteronuclear molecules that manifest as errors in calculated electrostatic dipoles. Here we show the magnitude of these errors on dipoles computed for a diverse set of 47 molecules taken from the recent benchmark study of Hait and Head-Gordon. We compare results of Perdew-Wang local spin density approximation (PW92), Perdew-Burke-Ernzerhof (PBE) generalized gradient approximation (GGA), and strongly constrained and appropriatedly normed (SCAN) meta-GGA dipole calculations, along with those of their respective self-interaction-corrected (SIC) counterparts, to reference values from accurate wave function-based methods. The SIC calculations were carried out using the Fermi-Löwdin orbital (FLO-SIC) approach. We find that correcting for self-interaction generally increases the degree of charge transfer, thereby increasing the size of calculated dipole moments. The FLO-SIC-PW92 and FLO-SIC-PBE dipoles are in better agreement with reference values than their uncorrected DFA counterparts, particularly for strongly ionic molecules where significant improvement is seen. Applying FLO-SIC to SCAN does not improve dipole values overall. In addition, we show that removing self-interaction improves the description of the dipole for stretched-bond geometries and recovers the physically correct separated atom limit of zero dipole. Finally, we find that the best agreement between the FLO-SIC-DFA and reference dipoles occurs when the molecular geometries are optimized using the FLO-SIC-DFA.

74 ATOMIC AND MOLECULAR PHYSICS↗

SAF values for internal photon emitters calculated for the RPI-P pregnant-female models using Monte Carlo methods

Estimates of radiation absorbed doses from radionuclides internally deposited in a pregnant woman and her fetus are very important due to elevated fetal radiosensitivity. This paper reports a set of specific absorbed fractions (SAFs) for use with the dosimetry schema developed by the Society of Nuclear Medicine's Medical Internal Radiation Dose (MIRD) Committee. The calculations were based on three newly constructed pregnant female anatomic models, called RPI-P3, RPI-P6, and RPI-P9, that represent adult females at 3-, 6-, and 9-month gestational periods, respectively. Advanced Boundary REPresentation (BREP) surface-geometry modeling methods were used to create anatomically realistic geometries and organ volumes that were carefully adjusted to agree with the latest ICRP reference values. A Monte Carlo user code, EGS4-VLSI, was used to simulate internal photon emitters ranging from 10 keV to 4 MeV. SAF values were calculated and compared with previous data derived from stylized models of simplified geometries and with a model of a 7.5-month pregnant female developed previously from partial-body CT images. The results show considerable differences between these models for low energy photons, but generally good agreement at higher energies. These differences are caused mainly by different organ shapes and positions. Other factors, such as the organ mass, the source-to-target-organ centroid distance, and the Monte Carlo code used in each study, played lesser roles in the observed differences in these. Since the SAF values reported in this study are based on models that are anatomically more realistic than previous models, these data are recommended for future applications as standard reference values in internal dosimetry involving pregnant females.

62 RADIOLOGY AND NUCLEAR MEDICINE↗