Updraft dynamics and microphysics: on the added value of the cumulus thermal reference frame in simulations of aerosol–deep convection interactions
Explore the source record for details and available documents.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
We present significantly improved proper motion measurements of the Milky Way's central stellar cluster. These improvements are made possible by refining our astrometric reference frame with a new geometric optical distortion model for the W. M. Keck II 10 m telescope's adaptive optics camera (NIRC2) in its narrow field mode. For the first time, this distortion model is constructed from on-sky measurements and is made available to the public in the form of FITS files. When applied to widely dithered images, it produces residuals in the separations of stars that are a factor of {approx}3 smaller compared with the outcome using previous models. By applying this new model, along with corrections for differential atmospheric refraction, to widely dithered images of SiO masers at the Galactic center (GC), we improve our ability to tie into the precisely measured radio Sgr A*-rest frame. The resulting infrared reference frame is {approx}2-3 times more accurate and stable than earlier published efforts. In this reference frame, Sgr A* is localized to within a position of 0.6 mas and a velocity of 0.09 mas yr{sup -1}, or {approx}3.4 km s{sup -1} at 8 kpc (1{sigma}). Also, proper motions for members of the central stellar cluster are more accurate, although less precise, due to the limited number of these wide field measurements. These proper motion measurements show that, with respect to Sgr A*, the central stellar cluster has no rotation in the plane of the sky to within 0.3 mas yr{sup -1} arcsec{sup -1}, has no net translational motion with respect to Sgr A* to within 0.1 mas yr{sup -1}, and has net rotation perpendicular to the plane of the sky along the Galactic plane, as has previously been observed. While earlier proper motion studies defined a reference frame by assuming no net motion of the stellar cluster, this approach is fundamentally limited by the cluster's intrinsic dispersion and therefore will not improve with time. We define a reference frame with SiO masers and this reference frame's stability should improve steadily with future measurements of the SiO masers in this region ({proportional_to}t {sup -3/2}). This is essential for achieving the necessary reference frame stability required to detect the effects of general relativity and extended mass on short-period stars at the GC.
Rationale Clumped isotope geochemistry examines the pairing or clumping of heavy isotopes in molecules and provides information about the thermodynamic and kinetic controls on their formation. The first clumped isotope measurements of carbonate minerals were first published 15 years ago, and since then, interlaboratory offsets have been observed, and laboratory and community practices for measurement, data analysis, and instrumentation have evolved. Here we briefly review historical and recent developments for measurements, share Tripati Lab practices for four different instrument configurations, test a recently published proposal for carbonate‐based standardization on multiple instruments using multi‐year data sets, and report values for 21 different carbonate standards that allow for recalculations of previously published data sets. Methods We examine data from 4628 standard measurements on Thermo MAT 253 and Nu Perspective IS mass spectrometers, using a common acid bath (90°C) and small‐sample (70°C) individual reaction vessels. Each configuration was investigated by treating some standards as anchors (working standards) and the remainder as unknowns (consistency standards). Results We show that different acid digestion systems and mass spectrometer models yield indistinguishable results when instrument drift is well characterized. For linearity correction, mixed gas‐and‐carbonate standardization or carbonate‐only standardization yields similar results. No difference is observed in the use of three or eight working standards for the construction of transfer functions. Conclusions We show that all configurations yield similar results if instrument drift is robustly characterized and validate a recent proposal for carbonate‐based standardization using large multiyear data sets. Δ 47 values are reported for 21 carbonate standards on both the absolute reference frame (ARF; also refered to as the Carbon Dioxide Equilibrated Scale or CDES) and the new InterCarb‐Carbon Dioxide Equilibrium Scale (I‐CDES) reference frame, facilitating intercomparison of data from a diversity of labs and instrument configurations and restandardization of a broad range of sample sets between 2006, when the first carbonate measurements were published, and the present.
We investigate torsion and noninertial effects on a spin-1/2 quantum particle in the nonrelativistic limit of the Dirac equation. We consider the cosmic dislocation spacetime as a background and show that a rotating system of reference can be used out to distances which depend on the parameter related to the torsion of the defect. Therefore, we analyse torsion effects on the spectrum of energy of a nonrelativistic Dirac particle confined to a hard-wall potential in a Fermi–Walker reference frame. -- Highlights: •Torsion effects on a spin- 1/2 particle in a noninertial reference frame. •Fermi–Walker reference frame in the cosmic dislocation spacetime background. •Torsion and noninertial effects on the confinement to a hard-wall confining potential.
Purpose: To develop an ultrasound learning-based tracking algorithm with the potential to provide real-time motion traces of anatomy-based fiducials that may aid in the effective delivery of external beam radiation. Methods: The algorithm was developed in Matlab R2015a and consists of two main stages: reference frame selection, and localized block matching. Immediately following frame acquisition, a normalized cross-correlation (NCC) similarity metric is used to determine a reference frame most similar to the current frame from a series of training set images that were acquired during a pretreatment scan. Segmented features in the reference frame provide the basis for the localized block matching to determine the feature locations in the current frame. The boundary points of the reference frame segmentation are used as the initial locations for the block matching and NCC is used to find the most similar block in the current frame. The best matched block locations in the current frame comprise the updated feature boundary. The algorithm was tested using five features from two sets of ultrasound patient data obtained from MICCAI 2014 CLUST. Due to the lack of a training set associated with the image sequences, the first 200 frames of the image sets were considered a valid training set for preliminary testing, and tracking was performed over the remaining frames. Results: Tracking of the five vessel features resulted in an average tracking error of 1.21 mm relative to predefined annotations. The average analysis rate was 15.7 FPS with analysis for one of the two patients reaching real-time speeds. Computations were performed on an i5-3230M at 2.60 GHz. Conclusion: Preliminary tests show tracking errors comparable with similar algorithms at close to real-time speeds. Extension of the work onto a GPU platform has the potential to achieve real-time performance, making tracking for therapy applications a feasible option. This work is partially funded by NIH grant R01CA190298.
For the Landau problem with a rotating magnetic field and a confining potential in the (changing) direction of the field, we derive a general factorization of the time evolution operator that includes the adiabatic factorization as a special case. The confining potential is assumed to be of a general form and it can correspond to nonlinear Heisenberg equations of motion. The rotation operator associated with the solid angle Berry phase is used to transform the problem to a rotating reference frame. In the rotating reference frame, we derive a natural factorization of the time evolution operator by recognizing the crucial role played by a gauge transformation. The major complexity of the problem arises from the coupling between motion in the direction of the magnetic field and motion perpendicular to the field. In the factorization, this complexity is consolidated into a single operator which approaches the identity operator when the potential confines the particle sufficiently close to a rotating plane perpendicular to the magnetic field. The structure of this operator is clarified by deriving an expression for its generating Hamiltonian. The adiabatic limit and non-adiabatic effects follow as consequences of the general factorization which are clarified using the magnetic translation concept.
Many multiscale methods for granular materials use periodic computational domains to consider particle scale interactions and then calculate the stress to drive the continuum scale calculations. For problems involving large material deformations, the computation domain often needs to be reinitialized because of the distortion, causing the loss of the history information of the system. This work introduces an algorithm to accommodate a large deformation of the material while maintaining the computational domain cuboid to avoid the domain reinitialization during the computation. The algorithm uses a rotating frame of reference, in which the velocity gradient can be represented by an upper triangular matrix. The deformation caused by the upper triangular matrix is treated by the image system implied in the periodicity to maintain the computational domain cuboid. The effect from the rotation of the reference frame is considered using the inertial forces. Finally, simulations of simple and pure shear motions are carried out to illustrate the algorithm.
Multiphoton ionization of helium is investigated in the superintense field regime, with particular emphasis on the role of the electron-electron interaction in the ionization and stabilization dynamics. To accomplish this, we solve ab initio the time-dependent Schroedinger equation with the full electron-electron interaction included. By comparing the ionization yields obtained from the full calculations with the corresponding results of an independent-electron model, we come to the somewhat counterintuitive conclusion that the single-particle picture breaks down at superstrong field strengths. We explain this finding from the perspective of the so-called Kramers-Henneberger frame, the reference frame of a free (classical) electron moving in the field. The breakdown is tied to the fact that shake-up and shake-off processes cannot be properly accounted for in commonly used independent-electron models. In addition, we see evidence of a change from the multiphoton to the shake-off ionization regime in the energy distributions of the electrons. From the angular distribution, it is apparent that the correlation is an important factor even in this regime.
In this paper, we propose an integral-based maximum power point tracking (MPPT) algorithm for point absorber wave energy conversion (WEC) systems. A permanent magnet synchronous generator (PMSG) is coupled to the point absorber and its drive implements the proposed MPPT control. While the rotating frame of reference of the PMSG implements power control, the slower mechanical frequency of the incident waves are processed with an additional transformation that yields another set of dc dynamics. The computed dc power in the new reference frame, which is focused on slow wave dynamics, is input to the MPPT control law that tunes the emulated resistance of the machine drive to extract peak power from the wave absorber device. We derive a stability condition for the proposed controller and validate our control design on a simulated 10kW system.
We present a formalism of Galilean quantum mechanics in non-inertial reference frames and discuss its implications for the equivalence principle. This extension of quantum mechanics rests on the Galilean line group, the semidirect product of the real line and the group of analytic functions from the real line to the Euclidean group in three dimensions. This group provides transformations between all inertial and non-inertial reference frames and contains the Galilei group as a subgroup. We construct a certain class of unitary representations of the Galilean line group and show that these representations determine the structure of quantum mechanics in non-inertial reference frames. Our representations of the Galilean line group contain the usual unitary projective representations of the Galilei group, but have a more intricate cocycle structure. The transformation formula for the Hamiltonian under the Galilean line group shows that in a non-inertial reference frame it acquires a fictitious potential energy term that is proportional to the inertial mass, suggesting the equivalence of inertial mass and gravitational mass in quantum mechanics. - Highlights: Black-Right-Pointing-Pointer A formulation of Galilean quantum mechanics in non-inertial reference frames is given. Black-Right-Pointing-Pointer The key concept is the Galilean line group, an infinite dimensional group. Black-Right-Pointing-Pointer Unitary, cocycle representations of the Galilean line group are constructed. Black-Right-Pointing-Pointer A non-central extension of the group underlies these representations. Black-Right-Pointing-Pointer Quantum equivalence principle and gravity emerge from these representations.
Purpose: We present a study of dosimetric consequences on doses in water in modeling in-air proton fluence independently along principle axes for rotated elliptical spots. Methods: Phase-space parameters for modeling in-air fluence are the position sigma for the spatial distribution, the angle sigma for the angular distribution, and the correlation between position and angle distributions. Proton spots of the McLaren proton therapy system were measured at five locations near the isocenter for the energies of 180 MeV and 250 MeV. An elongated elliptical spot rotated with respect to the principle axes was observed for the 180 MeV, while a circular-like spot was observed for the 250 MeV. In the first approach, the phase-space parameters were derived in the principle axes without rotation. In the second approach, the phase space parameters were derived in the reference frame with axes rotated to coincide with the major axes of the elliptical spot. Monte-Carlo simulations with derived phase-space parameters using both approaches to tally doses in water were performed and analyzed. Results: For the rotated elliptical 180 MeV spots, the position sigmas were 3.6 mm and 3.2 mm in principle axes, but were 4.3 mm and 2.0 mm when the reference frame was rotated. Measured spots fitted poorly the uncorrelated 2D Gaussian, but the quality of fit was significantly improved after the reference frame was rotated. As a Result, phase space parameters in the rotated frame were more appropriate for modeling in-air proton fluence of 180 MeV protons. Considerable differences were observed in Monte Carlo simulated dose distributions in water with phase-space parameters obtained with the two approaches. Conclusion: For rotated elliptical proton spots, phase-space parameters obtained in the rotated reference frame are better for modeling in-air proton fluence, and can be introduced into treatment planning systems.
Natural fracture data from wells 33-7, 33A-7,52A-7, 52B-7 and 83-11 at West Flank. Fracture orientations were determined from image logs of these wells (see accompanying submissions). Data files contain depth, apparent (in wellbore reference frame) and true (in geographic reference frame) azimuth and dip, respectively.
With rapid advancements in computer hardware, it is now possible to perform large simulations of granular flows using the Discrete Element Method (DEM). As a result, solids are increasingly treated in a discrete Lagrangian fashion in the gas–solids flow community. In this paper, the open-source MFIX-DEM software is described that can be used for simulating the gas–solids flow using an Eulerian reference frame for the continuum fluid and a Lagrangian discrete framework (Discrete Element Method) for the particles. This method is referred to as the continuum discrete method (CDM) to clearly make a distinction between the ambiguity of using a Lagrangian or Eulerian reference for either continuum or discrete formulations. This freely available CDM code for gas–solids flows can accelerate the research in computational gas–solids flows and establish a baseline that can lead to better closures for the continuum modeling (or traditionally referred to as two fluid model) of gas–solids flows. In this paper, a series of verification cases is employed which tests the different aspects of the code in a systematic fashion by exploring specific physics in gas–solids flows before exercising the fully coupled solution on simple canonical problems. It is critical to have an extensively verified code as the physics is complex with highly-nonlinear coupling, and it is difficult to ascertain the accuracy of the results without rigorous verification. These series of verification tests set the stage not only for rigorous validation studies (performed in part II of this paper) but also serve as a procedure for testing any new developments that couple continuum and discrete formulations for gas–solids flows.
Purpose: The x-ray performance evaluation of digital x-ray detectors is based on the calculation of the modulation transfer function (MTF), the noise power spectrum (NPS), and the resultant detective quantum efficiency (DQE). The flat images used for the extraction of the NPS should not contain any fixed pattern noise (FPN) to avoid contamination from nonstochastic processes. The ''gold standard'' method used for the reduction of the FPN (i.e., the different gain between pixels) in linear x-ray detectors is based on normalization with an average reference flat-field. However, the noise in the corrected image depends on the number of flat frames used for the average flat image. The aim of this study is to modify the standard gain correction algorithm to make it independent on the used reference flat frames. Methods: Many publications suggest the use of 10-16 reference flat frames, while other studies use higher numbers (e.g., 48 frames) to reduce the propagated noise from the average flat image. This study quantifies experimentally the effect of the number of used reference flat frames on the NPS and DQE values and appropriately modifies the gain correction algorithm to compensate for this effect. Results: It is shown that using the suggested gain correction algorithm a minimum number of reference flat frames (i.e., down to one frame) can be used to eliminate the FPN from the raw flat image. This saves computer memory and time during the x-ray performance evaluation. Conclusions: The authors show that the method presented in the study (a) leads to the maximum DQE value that one would have by using the conventional method and very large number of frames and (b) has been compared to an independent gain correction method based on the subtraction of flat-field images, leading to identical DQE values. They believe this provides robust validation of the proposed method.
The performance of rechargeable batteries and other electrochemical systems depends on the rate at which the working ion (often a cation) is transported from one electrode to the other. The cation transference number is an important transport parameter that affects this rate. The purpose of this perspective is to distinguish between approximate and rigorous methods used in the literature to measure the transference number. We emphasize the fact that this parameter is dependent on the reference frame used in the analysis; care must be taken when comparing values obtained from different sources to account for differences in reference frames. We present data obtained from a well‐characterized electrolyte. We compare rigorously determined transference numbers in two reference frames with values obtained by an approximate method. We conclude with a qualitative discussion of the relationship between the transference number and salt concentration gradients that are obtained when current is drawn through a battery.
Two recent papers (Ghez et al. 2008; Gillessen et al. 2009) have estimated the mass of and the distance to the massive black hole (MBH) in the center of the Milky Way using stellar orbits. The two astrometric data sets are independent and yielded consistent results, even though the measured positions do not match when simply overplotting the two sets. In this Letter, we show that the two sets can be brought to excellent agreement with each other when we allow for a small offset in the definition of the reference frame of the two data sets. The required offsets in the coordinates and velocities of the origin of the reference frames are consistent with the uncertainties given in Ghez et al. The so-combined data set allows for a moderate improvement of the statistical errors of the mass of and the distance to Sgr A*, but the overall accuracies of these numbers are dominated by systematic errors and the long-term calibration of the reference frame. We obtain R{sub 0} = 8.28 +- 0.15|{sub stat} +- 0.29|{sub sys} kpc and M{sub MBH} = 4.30 +- 0.20|{sub stat} +- 0.30|{sub sys} x 10{sup 6} M{sub sun} as best estimates from a multi-star fit.
We use 14 year baseline images obtained with the Wide Field and Planetary Camera 2 on board the Hubble Space Telescope (HST) to derive a proper motion for one of the Milky Way's most distant dwarf spheroidal companions, Leo II, relative to an extragalactic background reference frame. Astrometric measurements are performed in the effective point-spread function formalism using our own developed code. An astrometric reference grid is defined using 3224 stars that are members of Leo II and brighter than a magnitude of 25 in the F814W band. We identify 17 compact extragalactic sources, for which we measure a systemic proper motion relative to this stellar reference grid. We derive a proper motion [{mu}{sub {alpha},{mu}{delta}}] = [+104 {+-}113,-33 {+-} 151] {mu}as yr{sup -1} for Leo II in the heliocentric reference frame. Though marginally detected, the proper motion yields constraints on the orbit of Leo II. Given a distance of d {approx_equal} 230 kpc and a heliocentric radial velocity v{sub r} = +79 km s{sup -1}, and after subtraction of the solar motion, our measurement indicates a total orbital motion v{sub G} = 266.1 {+-} 128.7 km s{sup -1} in the Galactocentric reference frame, with a radial component v{sub r{sub G}}=21.5{+-}4.3 km s{sup -1} and tangential component v{sub t{sub G}} = 265.2 {+-} 129.4 km s{sup -1}. The small radial component indicates that Leo II either has a low-eccentricity orbit or is currently close to perigalacticon or apogalacticon distance. We see evidence for systematic errors in the astrometry of the extragalactic sources which, while close to being point sources, are slightly resolved in the HST images. We argue that more extensive observations at later epochs will be necessary to better constrain the proper motion of Leo II. We provide a detailed catalog of the stellar and extragalactic sources identified in the HST data which should provide a solid early-epoch reference for future astrometric measurements.
We present the principal astrometric results of the very long baseline interferometry (VLBI) program undertaken in support of the Gravity Probe B (GP-B) relativity mission. VLBI observations of the GP-B guide star, the RS CVn binary IM Pegasi (HR 8703), yielded positions at 35 epochs between 1997 and 2005. We discuss the statistical assumptions behind these results and our methods for estimating the systematic errors. We find the proper motion of IM Peg in an extragalactic reference frame closely related to the International Celestial Reference Frame 2 (ICRF2) to be -20.83 {+-} 0.03 {+-} 0.09 mas yr{sup -1} in right ascension and -27.27 {+-} 0.03 {+-} 0.09 mas yr{sup -1} in declination. For each component, the first uncertainty is the statistical standard error and the second is the total standard error (SE) including plausible systematic errors. We also obtain a parallax of 10.37 {+-} 0.07 mas (distance: 96.4 {+-} 0.7 pc), for which there is no evidence of any significant contribution of systematic error. Our parameter estimates for the {approx}25 day period orbital motion of the stellar radio emission have SEs corresponding to {approx}0.10 mas on the sky in each coordinate. The total SE of our estimate of IM Peg's proper motion is {approx}30% smaller than the accuracy goal set by the GP-B project before launch: 0.14 mas yr{sup -1} for each coordinate of IM Peg's proper motion. Our results ensure that the uncertainty in IM Peg's proper motion makes only a very small contribution to the uncertainty of the GP-B relativity tests.