Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Reducing heat load”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Effects of Hybridization on Selective Catalytic Reduction (SCR) Thermal Management of a Medium Heavy-Duty Hybrid Work Truck

The increased market penetration of hybrid electric powertrains in medium heavy-duty (MHD) applications has provided a novel platform for vehicle research. One example of such a platform is the MHD parallel hybrid truck developed by Odyne Systems, LLC. In collaboration with Odyne Systems, LLC and the Department of Energy (DOE), Oak Ridge National Laboratory (ORNL) developed a validated vehicle plant model for this truck and tested the Odyne powertrain in a hardware-in-the-loop (HIL) environment. While testing in the HIL environment, the effects of reduced engine load, and thus catalyst heating, on the selective catalytic reduction (SCR) catalyst produced diminished hybrid improvement as the level of energy storage usage increased. This article will discuss these results and the potentially unforeseen interactions with modern aftertreatment systems when hybridizing conventional powertrains.

33 ADVANCED PROPULSION SYSTEMS↗

Entrainment Makes Pollution More Likely to Weaken Deep Convective Updrafts Than Invigorate Them

Are the results of aerosol invigoration studies that neglect entrainment valid for diluted deep convective clouds? We address this question by applying an entraining parcel model to soundings from tropical and midlatitude convective environments, wherein pollution is assumed to increase parcel condensate retention. Invigoration of 5%–10% and <2% is possible in undiluted tropical and midlatitude parcels respectively when freezing is rapid. This occurs because the positive buoyancy contribution from freezing is larger than the negative buoyancy contribution from condensate loading, leading to positive net condensate contribution to buoyancy. However, aerosol-induced weakening is more likely when realistic entrainment rates occur because water losses from entrainment more substantially reduce the latent heating relative to the loading contribution. This leads to larger net negative buoyancy contribution from condensates in polluted than in clean entraining parcels. Our results demonstrate that accounting for entrainment is critical in conceptual models of aerosol indirect effects in deep convection.

54 ENVIRONMENTAL SCIENCES↗

Identifying Molecular Scale Interactions of Nucleating Agents with Salt Hydrates for Thermal Energy Storage Applications

Latent heat based thermal energy storage is of interest as a method to mitigate and time-shift thermal load peaks and hence reduce energy demands for heating and cooling buildings. Notably, Glauber’s salt (GS) presents a good choice as a phase change material (PCM) for building applications because it has a melting point near room temperature (i.e., 32.4 °C), a large heat of fusion and energy density, and is low cost (~ $100/ton). However, there are several known limitations to using GS as a PCM, such as incongruent melting, high degree of supercooling, and formation of other hydration states, which renders GS unsuitable for practical use. Inorganic crystals acting as nucleating agents can avoid some of these issues with GS [1]. Understanding nucleation behavior through typical calorimetry experiments offers limited insight into the molecular-scale mechanisms. Here, we report isothermal titration calorimetry [2] to investigate the interactions between sodium sulfate salt and an organic nucleating agent - glycine. Our experiments provide qualitative and quantitative understanding of how glycine interacts with sodium sulfate across various temperatures. The findings offer insights into the nucleation onset temperature (24°C) and underscore the pivotal role of glycine's zwitterionic structure in facilitating nucleation. This preliminary work provides a foundation for subsequent exploration of nucleating agents that would be incorporated in different salt hydrate systems. 1. Purohit, B. K., and V. S. Sistla. "Inorganic salt hydrate for thermal energy storage application: A review." Energy Storage 3, no. 2 (2021): e212. 2. Velázquez-Campoy, Adrián, Hiroyasu Ohtaka, Azin Nezami, Salman Muzammil, and Ernesto Freire. "Isothermal titration calorimetry." Current protocols in cell biology 23, no. 1 (2004): 17-8.

calorimetry, nucleation & growth↗

Heat load measurements for the PIP-II pHB650 cryomodule

This study presents a brief overview of the 1st and 2nd phases and an in-depth analysis of the 3rd phase heat load testing performed on the pHB650 (prototype High Beta 650 MHz) cryomodule at PIP2IT (PIP-II Injector Test Facility), with a focus on both the results and the methodological advancements that have improved testing efficiency and accuracy. A key challenge identified in the testing campaign is the higher-than-expected heat loads observed in the first PIP-II (Proton Improvement Plan II) prototype cryomodules (pSSR1 and pHB650) tested at PIP2IT. Elevated heat loads are concerning given the fixed capacity of the PIP-II cryoplant that is currently being installed at Fermilab. However, understanding the sources of these elevated heat loads offers a critical opportunity to implement effective heat load mitigations on upcoming PIP-II cryomodules to stay within the available capacity of the PIP-II cryoplant. The study includes a summary of test results, descriptions of measurement procedures, and key observations on parameters directly and indirectly related to heat load measurements. Direct observations include measured heat loads and the effectiveness of JT heat exchanger under varying conditions, while indirect observation analyze factors such as the temperature distribution on the two-phase pipe and relief piping under varying conditions. Thermal acoustic oscillations (TAO) were identified during testing, which was mitigated by replacing the original G10 stem with a stainless steel stem equipped with wipers for the cryomodule cooldown valve. A major innovation during pHB650 Phase 3 testing was the development of an automated Python script to streamline data acquisition, analysis, and reporting of heat load results. This script automatically retrieved data from ACNET (Accelerator Control Network), performed heat load calculations, and generated detailed reports featuring plots and tables. This advancement significantly reduced manual labor and enhanced the thoroughness of data analysis compared to earlier campaigns. The heat load test reports were promptly uploaded to the electronic logbook shortly after each test, enabling rapid feedback and collaboration between the SRF and cryogenic teams. The heat load measurements included various components: HTTS (high-temperature thermal shield), LTTS (low-temperature thermal shield), 2K isothermal and non-isothermal heat loads. Results were recorded both within the cryomodule and between the bayonet can supply and return. Measurements were conducted under different operating conditions such as "standard", "linac", and "simulated dynamic". Additionally, HTTS and LTTS heat loads were calculated in real time, allowing for the tracking of thermal stability and identification of changes during testing, both in steady-state and transient conditions. The results of this testing campaign not only provide valuable insights into the performance of the pHB650 cryomodule but also highlight best practices and lessons learned that will inform future cryomodule testing at PIP2IT. These include adopting automated tools for data analysis, refining real-time measurement capabilities, and emphasizing detailed pre-test planning. The framework established in this campaign aims to set an improved standard for cryomodule testing and heat load reporting in future cryomodule test campaigns.

Porwisiak, D. [Fermilab; Wroclaw Tech. U.]↗

Effectiveness of street trees in reducing air temperature and outdoor heat exposure in Las Vegas

Urban greening and especially tree planting strategies are being widely planned and implemented to mitigate urban overheating and thermal stress in many urban areas. However, the effectiveness of these strategies depends on multiple factors, including urban morphology, environmental conditions, and tree characteristics. This study investigates the effects of street tree planting strategies on air temperature and outdoor heat exposure in Las Vegas by combining an urbanized mesoscale climate model coupled to a multi-layer street tree model (Weather Research and Forecasting-BEP-Tree; Δ x = 900 m) with a microscale pedestrian heat exposure model (Temperatures of Urban Facets for Pedestrian; Δ x = 1 m). A series of simulations are conducted for July and August 2022. Large city-wide increases of a drought tolerant tree species cool air temperature mainly during the nighttime (up to 1.5 °C), with daytime effects being limited due to leaves shedding sensible instead of latent heat as stomata close in response to high vapor pressure deficits. Increased evaporative cooling is achieved with a different tree species (double at night, and reaching 0.4 °C during the day), but water requirements increase threefold. Despite their relatively small effect on air temperature during the day, trees provide significant shade by intercepting solar radiation, reducing mean radiant temperature (up to 16 °C) and enhancing outdoor thermal comfort, a major benefit of street trees in hot arid climates. The nighttime cooling of trees and the daytime reduction of radiant loading show potential to reduce the heat-related health impacts. Our results highlight the need to evaluate the effects of street trees on a case-by-case basis.

54 ENVIRONMENTAL SCIENCES↗

The Tiny Heater: Creating Heat with Hybrid Nano-Antennas [LDRD HQ Highlights Article]

SRNL scientists demonstrate that an electromagnetic field, either as a light or magnetic field, is selectively coupled to shape-selective hybrid nano-antennas for efficient thermal processes. Localized heating occurs extremely fast, reducing the ‘wasted' thermal load on the environment. Being non-contact, efficient, and highly selective, the required input energy is greatly diminished. By strategically placing nano-antennas at desired locations, heat can be controlled at the nano-level. The location for nano-antennas, and the subsequent energy deposition, may be fine-tuned through specific chemical, steric, or magnetic interactions. The nano-antennas, composed of combinations of plasmonic, magnetic, and hydride components, are used for controlled release of hydrogen isotopes, chemotherapy drugs, environmental contaminants, enhanced catalytic processes, (bio)imaging and therapeutics.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

DECOVALEX-2023: Task C Final Report

The Full-scale Emplacement (FE) heater experiment at the Mont Terri Underground Rock Laboratory (URL) was designed and conducted by Nagra to replicate an emplacement tunnel of Nagra’s reference repository design at 1:1 scale. Alongside testing the technical feasibility of constructing disposal tunnels, emplacing waste containers in the tunnels and then backfilling them, the main goals of the FE experiment are (1) to obtain a better understanding of the coupled effects of induced thermo-hydro-mechanical (THM) processes that may occur and (2) to validate existing coupled THM models (Müller et al., 2017). A key aspect of ensuring safety for repositories located in low-permeability rock involves minimizing any damage to the rock itself, thereby preserving its integrity and promoting a stable environment Amongst a number of processes that could damage the rock is the increase in pore pressure due to thermal loading caused by heat emitted from the waste. To reduce the potential damage of the rock, it is important to analyse the evolution of heat over time due to the heat load of the containers and assess possible consequences by coupled THM models. The aim of Task C of DECOVALEX-2023 was to build 3D numerical models of the FE experiment, focussing in particular on the heating induced pore pressure change in the Opalinus Clay. Data from a large number of sensors were available from the FE experiment for model comparison. These sensors measured temperature and relative humidity in the bentonite around the heaters, and temperature, pressure and displacement/strain in the surrounding Opalinus clay. Data were available from the start of excavation (April 2012) up to August 2020 for most sensors (more than 5 years from the start of heating in December 2014). To fulfil the overall aim of the task, the work was broken down into a number of steps, starting with simpler models to build confidence in each team’s approach and then moving to more complex models that better represent the FE experiment. Step 0 consisted of 2D benchmark models, gradually increasing the number of processes that are represented from thermal (T) only models in Step 0a, to coupled thermal hydraulic (TH) models in Step 0b with a representation of changing porosity, to coupled thermo-hydro-mechanical (THM) models in Step 0c, where porosity changes are calculated by the mechanical model. A detailed specification of processes, parameters, initial and boundary conditions was provided for this step, with the ambition that all teams would work towards close agreement in their model results, thus building confidence in the model implementations. vi It was not straightforward to achieve agreement between the teams, so additional steps (Step 0b2, 0b3, 0c2, 0c3) were added along with derivation of some analytical solutions against which the models could be compared. The reasons for the differences between teams were investigated and found to be caused primarily by different conceptual model assumptions (including temperature dependence of the thermal expansion of water), different model formulations (including porosity evolution) and differences in modelled domain sizes, boundary conditions and grid discretisation. This demonstrates that comparisons between multiple modelling teams and/or comparison with analytical results and experimental data are highly beneficial in providing an indication of uncertainty in model predictions. At the conclusion of Step 0, almost all teams had achieved a close agreement in model results and those that had not achieved an agreement knew the reason for this. Step 1 moved from 2D models to 3D models of the FE experiment without adding technical features like shotcrete or EDZ, and only considering the heating phase. Initially the 3D model was tightly specified to continue to build confidence in the model implementations (Step 1a). The results of Step 1a were compared to the data from the FE-experiment without the teams seeing the data. The teams were then provided with a sub-set of the data from the FE-experiment and invited to consider how best to use the large dataset for model comparison (Step 1b). Teams were then asked to use the data provided to calibrate their models, only changing material property values rather than adding features or processes to their models (Step 1c). In Step 1, teams were asked to only model the heating phase of the experiment, so pressure in the Opalinus Clay was reported as change in pressure since the initial conditions were specified rather than modelled. The change from 2D to 3D models was accompanied by an increase in the dispersion of results between the teams. Some of this was resolved during the task, but some remained and is potentially due to model discretisation. Calibration of parameters was useful in improving the fit of the models to the data but the remaining differences indicated that the models were missing features or processes. In Step 2, the teams were asked to update their models with additional features and processes as well as calibrating parameters to try and improve the fit of the models to the data. Teams were encouraged to represent ventilation of the open FE tunnel prior to backfilling with heaters and bentonite and in Step 2, the absolute pressure in the Opalinus Clay was compared between the teams. Teams took different approaches, but there was consideration of adding shotcrete and an EDZ into the model, representing stress change during excavation and different approaches to modelling ventilation of the FE tunnel. Overall, the documented results showed a very good agreement for temperature. The results for porewater pressure evolution showed a significant improvement for most teams compared to Step 1c with a good agreement to the measurements for several teams whereas some teams overpredicted the pressure increase and others overpredicted the drainage effect especially for the sensors close to the heater. Step 3 was an opportunity for teams to use the models developed in Step 1 and Step 2 to make predictions about the temperature and pressure changes that will be expected at the FE experiment over the next few years in light of the planned changes in thermal output of the heaters.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Stable heat and particle flux detachment with efficient particle exhaust in the island divertor of Wendelstein 7-X

The island divertor concept is an innovative and promising idea to handle heat and particle exhaust in stellarators. At the Wendelstein 7-X (W7-X) stellarator, this divertor concept plays a central role in the device mission to demonstrate reactor relevant plasma confinement for steady-state time scales of up to 30 minutes in the high-performance campaign (OP2) starting in 2022. During the recently concluded first campaign with the inertially cooled island divertor, a large step in the experimental qualification of this divertor concept has been made. In discharges heated with electron cylotron resonance heating of 5-6 MW, central densities in the range of 0.7-1.2 × 10 20 m -3 have been reached in combination with full divertor heat flux detachment. Also, significant neutral gas pressures and neutral compression ratios were shown for the first time in combination with reduced divertor particle flux. The divertor heat loads drop by an order of magnitude from >5 MW m -2 to below 0.5 MW m-2 with increasing density, and substantial compression of neutrals reaching neutral pressure in the sub-divertor volume of >6.0 × 10 -4 mbar was seen. These elevated neutral pressure levels can be obtained and maintained with an up to 80% reduction of the particle fluxes onto the divertor target tiles. This discharge scenario was held stably detached for up to 28 seconds, which is equivalent to several hundred energy confinement times τ E and longer than the time scales for current relaxation. No impurity accumulation was seen at constant Z eff ≈ 1.5 and the stored energy stayed constant at levels of W dia >600 kJ. The level of neutral pressure and compression reached in this scenario extrapolates well to the steady-state particle exhaust requirements for high-performance steady-state operation in OP2, in which the fully actively cooled high-heat-flux divertor will be available. Finally, an overview of this recently discovered divertor regime is given and the status of the physics understanding based on modeling of these regimes with the EMC3-EIRENE code is presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Energy Performance Validation of a Gaseous Air Cleaning Technology for Commercial Buildings

The U.S. Department of Energy (DOE) Building Technologies Office Commercial Building Integration group conducts evaluations of new energy efficiency technologies as part of the High Impact Technology Catalyst program. The subject of this field validation project is an air cleaning technology that removes gaseous contaminants from indoor air to reduce outdoor air ventilation requirements. Reducing the volume of outdoor air required reduces heating, ventilating, and air conditioning (HVAC) loads and can provide significant energy savings for some buildings in certain climates. The technology, called the HLR (HVAC Load Reduction), was developed by enVerid. The technology uses a solid regenerable sorbent material that was developed by DOE's National Energy Technology Laboratory and licensed to the vendor for this application. The sorbent material was originally developed to adsorb carbon dioxide (CO2); the vendor continued to develop the sorbent and the overall system so that it can also remove volatile organic compounds (including aldehydes), carbon monoxide, ozone, and particulate matter 2.5 micrometers in diameter or smaller (PM2.5) from the air. This material has low regeneration temperature requirements, and its sorption properties are unaffected by humidity levels, both of which are beneficial for building applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Thermally Anisotropic Building Envelope Integration into Panelized Metal Construction: Laboratory Evaluation in Guarded Hot Box

The Thermally Anisotropic Building Envelope (TABE) is an active building envelope system that can exchange thermal energy with a storage medium to reduce the building’s energy demand. TABE redirects thermal energy along thin conductive layers in the building envelope to hydronic loops that are connected to thermal energy storage (TES), where it will be available to offset future energy demand when the conditions are favorable. TABEs can also be connected with a geothermal loop to reduce the building’s heating and cooling loads. Due to the importance of thermally conductive metal layers to TABE function, this technology has potential for easy adoption into panelized metal construction. In this study, we illustrate the construction process of prototype metal panels containing TABE and the laboratory evaluation in Oak Ridge National Laboratory’s rotatable guarded hot box. The thermal performance of the prototype panel was assessed for both baseline and operational cases and the total heat flow extracted from the panel by TABE was quantified.

Howard, Daniel↗

Thermally anisotropic composites for thermal management in building environments

An improved system for thermal management is provided. The system includes thermally anisotropic composites coupled with a thermal loop to re-direct, reduce, and shape heat flows through a building envelope, having the potential to (1) significantly reduce envelope-generated heating and cooling loads and (2) provide grid services such as decreasing peak loads and shaping energy use. In one embodiment, the thermal management system includes an anisotropic composite that consists of alternating layers of thermal insulation and thermally conductive materials that are immediately adjacent to each other, including polyisocyanurate foam boards and aluminum sheets. The thermal management system also includes a thermal loop along the long edge or the entire the perimeter of the anisotropic composite, the thermal loop having dynamically controlled or floating temperature that is maintained at lower than an outdoor ambient temperature (for cooling). An interior wall structure is inwardly adjacent to the anisotropic composite.

Shrestha, Som S.↗

Enhanced Air-Cooling System with Optimized Asynchronously-Cooled Thermal Energy Storage

A transformative dry-cooling system that includes two primary dry-cooling components has been developed in this project. The two main features of this new technology consist of: (a) an ultra-enhanced air-cooled condenser (ACC), with novel swirl-producing and boundary-layer disrupting enhanced surface on the air-side of the condenser that substantially increase the heat transfer coefficients, and (b) a novel daytime peak-load shifting system that reduces the ambient air inlet temperature for air cooling, consisting of a highly compact and enhanced air pre-cooler that transfers the heat load to a unique thermal energy storage (TES), and which is coupled to the ACC in (a).

20 FOSSIL-FUELED POWER PLANTS↗

Performance Assessment of a Dual-purpose HP-TES for a Typical Year Comparing Different Climate Zones

Complete electrification of heating and cooling systems in the United States would overload the existing electrical grid. To this end, recent research efforts have focused on energy storage as one way to reduce ever-increasing peak electricity demands. One such technology is heat pump integrated thermal-energy storage (HP-TES) systems, which can enable load-shifting and reduce demand during peak hours. In this work, a Modelica model of a 4-Ton, dual-mode (heating and cooling) HP-TES system using a room-temperature phase-change material (PCM) integrated through a secondary hydronic loop was developed and simulated for a typical meteorological year in Riverside, CA (ASHRAE Climate Zone 2B), and Chicago, IL (ASHRAE Climate Zone 5A), for a DOE small office prototype building. The COP improvement and demand reduction were analyzed during the time-of-use peak hours along with the required recharge cycle energy demand. A typical summer in Riverside, CA resulted in model-predicted peak COP increases of 50 – 100% compared to the baseline heat pump, especially at higher outdoor temperatures, coupled with maximum peak energy reductions of 22%. During shoulder and winter season simulations, heating energy savings were higher as outdoor temperatures dropped below the PCM phase change temperature. For Chicago, IL, backup heating was necessary to meet the required system capacity for very cold ambient conditions, resulting in winter peak energy savings between 16 – 60% when accounting for backup heating requirements. The recharge energy was found to be mostly below the baseline HP energy during the peak. With improved component selections and controls, the recharge energy may be reduced. The outcomes from the simulations can provide first-order estimates for potential peak energy savings, challenges, and required controls in any location before conducting any field testing.

25 ENERGY STORAGE↗

Phase change material-to-refrigerant heat exchangers: Experimental validation and uneven melting analysis

Thermal energy storage (TES) using phase change materials (PCMs) enables load shifting and reduces mismatches between the building's thermal demand and the heat pump (HP) system's thermal capacity. While most TES studies have focused on single-phase heat transfer fluids, PCM-to-refrigerant heat exchangers (PRHX), in which the refrigerant undergoes liquid-vapor phase change, remain largely underexplored. Here, to address this gap, this study systematically investigates a shell-and-tube PRHX operating as the condenser in an HP through experiments and simulations. A two-dimensional enthalpy-based finite-volume PRHX model was developed and validated against experimental data, including refrigerant and PCM temperature profiles, PRHX capacity, and system-level performance. Results show three characteristic stages: Stage I, the condenser temperature rapidly increases with PCM in the solid state absorbing sensible heat; Stage II, stable operation during PCM phase change; and Stage III, performance decline once part of the PCM becomes fully melted. Heat transfer analysis revealed that uneven PCM melting along the condenser length was driven primarily by variations in the refrigerant-side heat transfer coefficient, rather than local approach temperature differences. Further study demonstrated that minimizing refrigerant outlet subcooling led to more uniform PCM melting and extended Stages I and II by up to 89%. This paper provides a validated PRHX model, clarifies the mechanisms of uneven PCM melting, and highlights subcooling control as an effective strategy to improve TES performance in HP systems without requiring secondary loops.

Graphite matrix↗

Thermal analysis of RHIC arc dipole magnet cold mass with EIC beam screen

The existing RHIC storage rings – including their superconducting magnet arcs – will be used for the hadron storage ring of the Electron-Ion Collider (EIC). The vacuum chamber of these magnets was not designed for the EIC hadron beams, with shorter bunches and of higher average current than the RHIC beams. With the current stainless steel beam pipe, the resistive-wall (RW) heating will exceed the dynamic heat load budget. Limiting the RW heating is important to prevent the superconducting magnets from quenching and to maintain a low screen temperature necessary to impede the rise of RW heating (higher resistance at higher temperature) as well as to achieve desired ultra-high vacuum. In addition, simulations predict the formation of electron cloud which would further contribute to the dynamic heat load and could compromise the quality and stability of the beam. To reduce the resistive-wall heating and suppress electron cloud, a beam screen will be installed in the vacuum chamber of the RHIC SC magnets. The screen will have a high RRR copper layer at its inner face – useful to reduce the resistive-wall impedance thanks to its high conductivity especially at cryogenic temperatures – and will be coated with a thin layer of amorphous carbon, a material with low secondary electron yield to suppress the formation of electron clouds. The baseline solution envisages a screen that will be cooled by thermal contact to the 4.55 K beam pipe. Detailed thermal analysis have been conducted in ANSYS 2020 for an arc dipole cold mass equipped with a beam screen in order to study the feasibility of a passively-cooled screen and guide its design. Temperature-dependent thermal conductivity properties of all materials in the operating (cryogenic) temperature range are considered. Suitable assumptions and simplifications are made to model the magnet coil and calculate its homogenized thermal conductivity. Sensitivity studies with respect to layer thicknesses and area of contact are carried out and results are presented.

43 PARTICLE ACCELERATORS↗

Onsite Energy Techno-Economic Analysis Using REopt

Since 2019, the National Renewable Energy Laboratory (NREL) has collaborated with IEDO's Combined Heat and Power (CHP) Deployment Program and the CHP Technical Assistance Partnerships (TAPs) to expand the capabilities of NREL's publicly available REopt® tool for techno-economic analysis of on-site energy. As a result, capabilities to analyze heating and cooling loads and serve those loads with CHP were added to the REopt tool in 2021. Currently, NREL is using REopt to evaluate the economics and feasibility of deploying distributed energy resources at sites of 3-5 manufacturers. The analysis is based on location, site-specific load data, customized utility bill analysis, and other criteria such as resilience needs and decarbonization targets. The objectives of the current effort are to (1) assist manufacturers with analyzing on-site energy options, including CHP, solar photovoltaics (PV), wind, and battery storage, (2) validate the capabilities and use of REopt to provide technical assistance to manufacturers, and (3) publish case studies showcasing the engagement, key takeaways, and lessons learned. Future work is expected to include additional REopt capabilities for evaluating other technologies to reduce scope 1 emissions, such as electrifying process heating loads, using carbon-free fuels, and other clean heat strategies.

ENERGY PLANNING, POLICY, AND ECONOMY↗

Improving Heat Conduction of Insulated Metal Substrate with Thermal Pyrolytic Graphite Core for SiC Power Module Packaging

TPG-core IMS concept was jointly explored in this study. Integrating high thermally conductive TPG graphite core into IMS is expected to simultaneously achieve high thermal conductivity from TPG and electrical functionalities from IMS. Nearly 2x thermal conductivity and 30% weight saving was demonstrated on TPG-core IMS compared to conventional Cu-core IMS. Significant junction temperature reduction (11°C) in steady state and power cycling was revealed by the thermal analysis as the result of improved thermal spreading in plane and through the thickness. The study also proved the manufacturability and compatibility of this TPG-core IMS structure to the existing IMS production and power module assembling. Finally, the integration of TPG and IMS paves a new packaging route to increase heat load, improve reliability, simplify module design and reduce assembling cost and number of steps.

36 MATERIALS SCIENCE↗