Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Raman thermometry”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

51 records · Page 3

Temperature Measurements in Hypersonic Wind Tunnels via Femtosecond Coherent Anti-Stokes Raman Scattering

A femtosecond coherent anti-Stokes Raman scattering (fs CARS) instrument is developed to perform gas-phase thermometry in cold-flow hypersonic wind tunnels. Measurements are reported for Mach 8 and 14 pure-nitrogen flows. The fs CARS instrument includes a 100 fs pump/Stokes pulse and a spectrally narrow probe pulse from a second harmonic bandwidth compressor. Important experimental considerations such as limits on the pump/Stokes pulse energy are discussed. The fs CARS focusing and collimating optics are mounted on a two-axis translation stage system to scan the measurement location during a 30 second wind tunnel run. Single-laser-shot rotational CARS spectra are recorded at the laser repetition rate of 1 kHz in the wind tunnel freestream and near simple cone models. Spectral fitting is used to determine quantitative gas temperatures. Freestream temperatures at Mach 8 and 14 spanned ranges of 40–75 and 35–50 K, respectively, depending on tunnel operating conditions. Temperature variations across the central 100 mm span of the wind tunnel were quantified. Measured temperature jumps across conical bow shocks from various models varied by less than 1% from predicted values. Hypersonic boundary layer measurements were demonstrated. In conclusion, these measurements illustrate the utility and robustness of this instrument for the study of complex fluid flow phenomena in challenging ground test facilities.

Aerodynamics↗

Dual-Pump CARS Thermometry and Species Concentration Measurements in a Supersonic Combustor

The dual-pump coherent anti-Stokes Raman spectroscopy (CARS) method was used to measure temperature and the absolute mole fractions of N2, O2 and H2 in a supersonic combustor. Experiments were conducted in NASA Langley Research Center's Direct Connect Supersonic Combustion Test Facility. In this facility, hydrogen and air bum to increase the enthalpy of the test gas; O2 is then added to simulate air. This gas is expanded through a Mach 2 nozzle and into a combustor model consisting of a short constant-area section followed by a small rearward facing step and another constant area section. At the end of this straight section H2 fuel is then injected at Mach 2 and at 30 deg. angle with respect to the freestream. One wall of the duct then expands at a 3 deg. angle for over 1 meter. The ensuing combustion is monitored optically through ports in the side of the combustor. CARS measurements were performed at the nozzle exit and at four different planes downstream fuel injection. Maps were obtained of the mean temperature, as well as quantitative N2 and O2 and qualitative H2 mean mole fraction fields. Correlations between fluctuations of the different measured parameters are presented for one of the planes of data.

OByrne, Sean↗

Collisional excitation of CO by H2O - An astrophysicist's guide to obtaining rate constants from coherent anti-Stokes Raman line shape data

Rate constants for excitation of CO by collisions with H2O are needed to understand recent observations of comet spectra. These collision rates are closely related to spectral line shape parameters, especially those for Raman Q-branch spectra. Because such spectra have become quite important for thermometry applications, much effort has been invested in understanding this process. Although it is not generally possible to extract state-to-state rate constants directly from the data as there are too many unknowns, if the matrix of state-to-state rates can be expressed in terms of a rate-law model which depends only on rotational quantum numbers plus a few parameters, the parameters can be determined from the data; this has been done with some success for many systems, especially those relevant to combustion processes. Although such an analysis has not yet been done for CO-H2O, this system is expected to behave similarly to N2-H2O which has been well studies; modifications of parameters for the latter system are suggested which should provide a reasonable description of rate constants for the former.

Green, Sheldon↗

Application of Modern Design of Experiments to CARS Thermometry in a Model Scramjet Engine

We have applied formal experiment design and analysis to optimize the measurement of temperature in a supersonic combustor at NASA Langley Research Center. We used the coherent anti-Stokes Raman spectroscopy (CARS) technique to map the temperature distribution in the flowfield downstream of an 1160 K, Mach 2 freestream into which supersonic hydrogen fuel is injected at an angle of 30 degrees. CARS thermometry is inherently a single-point measurement technique; it was used to map thc flow by translating the measurement volume through the flowfield. The method known as "Modern Design of Experiments" (MDOE) was used to estimate the data volume required, design the test matrix, perform the experiment and analyze the resulting data. MDOE allowed us to match the volume of data acquired to the precision requirements of the customer. Furthermore, one aspect of MDOE, known as response surface methodology, allowed us to develop precise maps of the flowfield temperature, allowing interpolation between measurement points. An analytic function in two spatial variables was fit to the data from a single measurement plane. Fitting with a Cosine Series Bivariate Function allowed the mean temperature to be mapped with 95% confidence interval half-widths of +/- 30 Kelvin, comfortably meeting the confidence of +/- 50 Kelvin specified prior to performing the experiments. We estimate that applying MDOE to the present experiment saved a factor of 5 in data volume acquired, compared to experiments executed in the traditional manner. Furthermore, the precision requirements could have been met with less than half the data acquired.

Danehy, P. M.↗

Simultaneous single-shot rotation–vibration non-equilibrium thermometry using pure rotational fs/ps CARS coherence beating

Here, we report the development of a simple and sensitive two-beam hybrid femtosecond/picosecond pure rotational coherent anti-Stokes Raman scattering (fs/ps CARS) method to simultaneously measure the rotational and vibrational temperatures of diatomic molecules. Rotation–vibration non-equilibrium plays a key role in the chemistry and thermalization in low-temperature plasmas as well as thermal loading of hypersonic vehicles. This approach uses time-domain interferences between ground state and vibrationally excited N 2 molecules to intentionally induce coherence beating that leads to apparent non-Boltzmann distributions in the pure rotational spectra. These distortions enable simultaneous inference of both the rotational and vibrational temperatures. Coherence beating effects were observed in single-shot fs/ps CARS measurements of a 75 Torr N 2 DC glow discharge and were successfully modeled for rotational and vibrational temperature extraction. We show that this method can be more sensitive than a pure rotational fs/ps CARS approach using a spectrally narrow probe pulse. Lastly, we experimentally measured the beat frequencies via Fourier transform of the time-domain response and obtained excellent agreement with the model.

42 ENGINEERING↗

Cars Thermometry in a Supersonic Combustor for CFD Code Validation

An experiment has been conducted to acquire data for the validation of computational fluid dynamics (CFD) codes used in the design of supersonic combustors. The primary measurement technique is coherent anti-Stokes Raman spectroscopy (CARS), although surface pressures and temperatures have also been acquired. Modern- design- of-experiment techniques have been used to maximize the quality of the data set (for the given level of effort) and minimize systematic errors. The combustor consists of a diverging duct with single downstream- angled wall injector. Nominal entrance Mach number is 2 and enthalpy nominally corresponds to Mach 7 flight. Temperature maps are obtained at several planes in the flow for two cases: in one case the combustor is piloted by injecting fuel upstream of the main injector, the second is not. Boundary conditions and uncertainties are adequately characterized. Accurate CFD calculation of the flow will ultimately require accurate modeling of the chemical kinetics and turbulence-chemistry interactions as well as accurate modeling of the turbulent mixing

Cutler, A. D.↗

Hybrid time–frequency domain dual-probe coherent anti-Stokes Raman scattering for simultaneous temperature and pressure measurements in compressible flows via spectral fitting

We demonstrate a hybrid time–frequency spectroscopic method for simultaneous temperature/pressure measurements in nonreacting compressible flows with known gas composition. Hybrid femtosecond–picosecond, pure-rotational coherent anti-Stokes Raman scattering (CARS), with two independent, time-delayed probe pulses, is deployed for single-laser-shot measurements of temperature and pressure profiles along an ∼ <#comment/> 5 -mm line. The theory of dual-probe CARS is presented, along with a discussion of the iterative fitting of experimental spectra. Temperature is obtained from spectra acquired with an early, near-collision-free probe time delay ( τ <#comment/> 1 = 0 p s ) and pressure from spectra obtained at probe delays of τ <#comment/> 2 = 150 − <#comment/> 1000 p s , where collisions significantly impact the spectral profile. Unique solutions for temperature and pressure are obtained by iteratively fitting the two spectra to account for small collisional effects observed for the near zero probe delay spectrum. A dual-probe pure-rotational CARS system, in a 1D line-imaging configuration, is developed to demonstrate effectively the simultaneous temperature and pressure profiles recorded along the axial centerline of a highly underexpanded jet. The underexpanded air jet permits evaluation of this hybrid time–frequency domain approach for temperature and pressure measurements across a wide range of low-temperature–low-pressure conditions of interest in supersonic ground-test facilities. Single-laser-shot measurement precisions in both quantities and pressure measurement accuracy are systematically evaluated in the quiet zone upstream of the Mach disk. Precise thermometry approaching 1%−2% is observed in regions of high CARS signal-to-noise ratios. Pressure measurements are optimized at probe time delays where the ratio of the late probe delay to the Raman lifetime exceeds four ( τ <#comment/> 2 / τ <#comment/> R > <#comment/> 4 ). The impact of low-temperature Raman linewidths on CARS pressure measurements is evaluated, and comparisons of CARS pressures obtained with our recent low-temperature pure-rotational Raman linewidth data and extrapolated high-temperature Q -branch linewidths are presented. Considering all measurements with τ <#comment/> 2 / τ <#comment/> R ≥ <#comment/> 4.0 , measured pressures were on average 7.9% of the computed isentropic values with average shot-to-shot deviations representing a combination of instrument noise and fluid fluctuations of 5.0%.

Retter, Jonathan E.↗

1-D imaging of rotation-vibration non-equilibrium from pure rotational ultrafast coherent anti-Stokes Raman scattering

We present one-dimensional (1-D) imaging of rotation-vibration non-equilibrium measured by two-beam pure rotational hybrid femtosecond/picosecond coherent anti-Stokes Raman scattering (fs/ps CARS). Simultaneous measurements of the spatial distribution of molecular rotation-vibration non-equilibrium are critical for understanding molecular energy transfer in low temperature plasmas and hypersonic flows. However, non-equilibrium CARS thermometry until now was limited to point measurements. The red shift of rotational energy levels by vibrational excitation was used to determine the rotational and vibrational temperatures from 1-D images of the pure rotational spectrum. Vibrational temperatures up to 5500 K were detected in a CH4/N2 nanosecond-pulsed pin-to-pin plasma within 2 mm near the cathode. As a result, this approach enables study of non-equilibrium systems with 40 µm spatial resolution.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Elastic thermobarometry on metapelites across the crustal section of the Famatinian Arc, Argentina

We applied elastic thermobarometry on garnet-bearing migmatites along two transects through the crustal section at Sierra Valle Fértil-La Huerta, Argentina. We performed quartz-in-garnet barometry and zircon-in-garnet thermometry on metapelites from different paleo-depths across the crustal section. Our work recovers entrapment pressures ranging from 240 to 1330 MPa and entrapment temperatures between 691 and 1574 °C. The entrapment conditions are broadly consistent with anticipated pressures and temperatures along the crustal section derived previously using conventional, thermodynamic thermobarometers. The quartz-in-garnet barometer reproduces those conventionally established entrapment conditions when samples only experienced conditions within the alpha-quartz stability field. Raman-derived pressures for samples that experienced beta-quartz reference conditions are commonly much higher than those established by conventional barometry. Samples that preserve compressive (positive) residual pressures best reproduce reference entrapment pressures. Entrapment temperatures show high variability and overestimation of temperature conditions compared to conventional results. These results indicate elastic thermobarometry over- or under-estimates crystallization conditions in rocks crystallized at high temperatures, as is common in the Famatinian Arc deep-crust. We suggest that modeling quartz behavior across the alpha–beta transition may present challenges, as does shape maturation, viscous deformation, and radiation damage in zircon.

58 GEOSCIENCES↗

Enhanced upconversion and photoconductive nanocomposites of lanthanide-doped nanoparticles functionalized with low-vibrational-energy inorganic ligands

Upconverting nanoparticles (UCNPs) convert near-infrared (IR) light into higher-energy visible light, allowing them to be used in applications such as biological imaging, nano-thermometry, and photodetection. It is well known that the upconversion luminescent efficiency of UCNPs can be enhanced by using a host material with low phonon energies, but the use of low-vibrational-energy inorganic ligands and non-epitaxial shells has been relatively underexplored. Here, we investigate the functionalization of lanthanide-doped NaYF4 UCNPs with low-vibrational-energy Sn2S64- ligands. Raman spectroscopy and elemental mapping are employed to confirm the binding of Sn2S64- ligands to UCNPs. This binding enhances upconversion efficiencies up to a factor of 16, consistent with an increase in the luminescent lifetimes of the lanthanide ions. Annealing Sn2S64--capped UCNPs results in the formation of a nanocomposite comprised of UCNPs embedded within an interconnected matrix of SnS2, enabling each UCNP to be electrically accessible through the semiconducting SnS2 matrix. This facilitates the integration of UCNPs into electronic devices, which we demonstrate through the fabrication of a UCNP-SnS2 photodetector that detects UV and near-IR light. Our findings show the promise of using inorganic capping agents to enhance the properties of UCNPs while facilitating their integration into optoelectronic devices.

Pan, Jia-Ahn↗

Develop Accurate Techniques for Passive SiC Temperature Monitoring of Miniature Samples for Cross-Cutting Applications

Passive thermometry is critically important because most fuels and materials irradiation experiments are not instrumented, and it is necessary to understand the irradiation temperature to properly interpret any post-irradiation examination data, including evolving properties and/or microstructures. The standard passive thermometry approach uses continuous dilatometry to evaluate changes in the instantaneous coefficient of thermal expansion during post-irradiation thermal annealing. This approach has limitations in terms of sample size (minimum length requirements) and the maximum irradiation temperature that can be accurately determined, which is limited by the reduced swelling (and therefore recovery) following higher temperature irradiation and limitations on the furnaces used with push-rod dilatometers. This work evaluates two new proposed techniques for post-irradiation evaluation of passive SiC temperature monitors: differential scanning calorimetry (DSC) and Raman spectroscopy. DSC is an extremely sensitive technique that can be used for any specimen geometry and is capable of higher temperature operation. Raman spectroscopy is similar in that it is a surface technique capable of examining extremely small samples (submillimeter), can be used with a heated stage up to 1,500°C (planned for future work), and is capable of mapping local irradiation temperatures throughout a sample. Existing SiC samples that were previously irradiated over a wide range of temperatures were cut into multiple pieces to allow for annealing studies using multiple different techniques: dilatometry, DSC, and Raman spectroscopy. This approach mitigates the concern that samples analyzed using one technique may have a slightly different irradiation history than those analyzed using a different technique. Recovery was clearly observed during annealing using both DSC and dilatometry. In some cases, a direct comparison could not be made due to some of the DSC runs accidentally including material from multiple specimens and issues with using an alternative DSC sample holder for the highest temperature annealing studies. Nevertheless, one trend was clear: the DSC runs resulted in higher irradiation temperatures compared to those of the dilatometry runs. Part of this could be attributed to the higher temperature ramp rates used during the DSC runs, which are often preferred to reduce noise in the measurements. By comparison, dilatometry has previously been shown to produce better data at lower ramp rates. Future work should further investigate the ideal ramp rate for both techniques to produce consistent results. Additional work should evaluate the best holder material to use for DSC runs exceeding 1,000°C to provide reliable data while preventing interactions between SiC and the holder.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Analysis of picosecond coherent anti-Stokes Raman spectra for gas-phase diagnostics

We present a hybrid frequency- and time-domain solution, applicable to the case of picosecond coherent anti-Stokes Raman scattering (CARS), for gas-phase diagnostics. A solution has been derived based on both physical arguments and four-wave mixing equations for picosecond CARS, with pulse durations that are comparable to the dephasing time scale for gas-phase Raman coherence—a regime where commonly employed solutions for impulsive (femtosecond) or cw (nanosecond) pump/Stokes forcing are not strictly valid. We present the ps-CARS spectrum in the form of incoherent sums of CARS intensity spectra, calculated from the fundamental solution for impulsive pump/Stokes Raman preparation. The solution was examined for temperatures from 1000–3000 K, for four plausible experimental configurations, with laser pulse durations of 50–150 ps, and probe pulse delays from −20 to 240 ps. Approximations based on cw and impulsive pump/Stokes preparation to fit picosecond CARS spectra at atmospheric pressure were examined and the relative thermometric accuracy and computational cost of these approximations were quantified for the case of a zero nonresonant CARS contribution, and a nonresonant susceptibility equal to 10% of the Raman-resonant value at the N 2 bandhead. The nanosecond CARS approximation can result in large fitting errors when the probe pulse time delay is less than the probe pulse duration. Errors as large as 10–20% are observed in the fit temperatures for a zero picosecond probe pulse delay, when the nonresonant background is neglected, largely due to an inability of the time-independent cw model to capture transient frequency spread dephasing effects at the Q -branch bandhead. The inclusion of a nonresonant background results in 40–60% thermometry errors with a nanosecond model at a zero-probe delay. Time-dependent impulsive calculations used for femtosecond CARS better approximate the structure of the N 2 bandhead, reducing temperature fitting errors to 5–10% at a short probe pulse delay. The impulsive approximation results in errors up to 10% at intermediate probe pulse delays, where the coherence of the pump and probe pulses leads to multiple terms in the picosecond CARS solution. Both approximations improve as the probe pulse delay exceeds the probe duration. The nanosecond approximation results in a 2–3% error, while the impulsive model results in differences of less than 1% in some cases. Fits to experimental data obtained using short, ∼60ps pulses at a zero probe time delay and longer 100 ps pulses at a substantial 200 ps delay are presented with accuracies of 1–3% in the fit temperature.

Kearney, Sean P.↗

Develop Accurate Techniques for Passive SiC Temperature Monitoring of Miniature Samples for Cross-Cutting Applications

Passive thermometry is critically important because most fuels and materials irradiation experiments are not instrumented, and it is necessary to understand the irradiation temperature to properly interpret any post-irradiation examination data, including evolving properties and/or microstructures. The standard passive thermometry approach uses continuous dilatometry to evaluate changes in the instantaneous coefficient of thermal expansion during post-irradiation thermal annealing. This approach has limitations in terms of sample size (minimum length requirements) and the maximum irradiation temperature that can be accurately determined, which is limited by the reduced swelling (and therefore recovery) following higher temperature irradiation and limitations on the furnaces used with push-rod dilatometers. This work evaluates two new proposed techniques for post-irradiation evaluation of passive SiC temperature monitors: differential scanning calorimetry (DSC) and Raman spectroscopy. DSC is an extremely sensitive technique that can be used for any specimen geometry and is capable of higher temperature operation. Raman spectroscopy is similar in that it is a surface technique capable of examining extremely small samples (submillimeter), can be used with a heated stage up to 1,500°C (planned for future work), and is capable of mapping local irradiation temperatures throughout a sample. Existing SiC samples that were previously irradiated over a wide range of temperatures were cut into multiple pieces to allow for annealing studies using multiple different techniques: dilatometry, DSC, and Raman spectroscopy. This approach mitigates the concern that samples analyzed using one technique may have a slightly different irradiation history than those analyzed using a different technique. Recovery was clearly observed during annealing using both DSC and dilatometry. In some cases, a direct comparison could not be made due to some of the DSC runs accidentally including material from multiple specimens and issues with using an alternative DSC sample holder for the highest temperature annealing studies. Nevertheless, one trend was clear: the DSC runs resulted in higher irradiation temperatures compared to those of the dilatometry runs. Part of this could be attributed to the higher temperature ramp rates used during the DSC runs, which are often preferred to reduce noise in the measurements. By comparison, dilatometry has previously been shown to produce better data at lower ramp rates. Future work should further investigate the ideal ramp rate for both techniques to produce consistent results. Additional work should evaluate the best holder material to use for DSC runs exceeding 1,000°C to provide reliable data while preventing interactions between SiC and the holder.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Noncolinear optical parametric oscillator for broadband nanosecond pulse-burst CARS diagnostics in gases

We report demonstration of broadband nanosecond coherent anti-Stokes Raman scattering (CARS) using a burst-mode-pumped noncolinear optical parametric oscillator (NOPO) has been achieved at a pulse repetition rate of 40 kHz. The NOPO is pumped with the 355-nm output of a burst-mode Nd:YAG laser at 50 mJ/pulse for 45 pulses and produces an output centered near 607 nm, with a bandwidth of 370 cm –1 at energies of 5 mJ/pulse. A planar BOXCARS phase matching scheme uses the broadband NOPO output as the Stokes beam and the narrowband 532-nm burst-mode output for the two CARS pump beams for single-laser-shot nitrogen thermometry in near adiabatic H 2 /air flames at temperatures up to 2200 K.

47 OTHER INSTRUMENTATION↗

Optimization of gold germanium (Au 0.17 Ge 0.83 ) thin films for high sensitivity resistance thermometry

Gold–germanium (Au x Ge 1–x ) solid solutions have been demonstrated as highly sensitive thin film thermometers for cryogenic applications. However, little is known regarding the performance of the films for thicknesses less than 100 nm. In response, here we report on the resistivity and temperature coefficient of resistance (TCR) for sputtered films with thicknesses ranging from 10 to 100 nm and annealed at temperatures from 22 to 200°C. The analysis is focused upon composition x=0.17, which demonstrates a strong temperature sensitivity over a broad range. The thinnest films are found to provide an enhancement in TCR, which approaches 20% K –1 at 10 K. Furthermore, reduced anneal temperatures are required to crystallize the Ge matrix and achieve a maximum TCR for films of reduced thickness. These features favor the application of ultra-thin films as high-sensitivity, on-device thermometers in micro- and nanolectromechanical systems.

59 BASIC BIOLOGICAL SCIENCES↗