Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Radiometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

The Impact of Indoor and Outdoor Radiometer Calibration on Solar Measurements: Preprint

Accurate solar radiation data sets are critical to reducing the expenses associated with mitigating performance risk for solar energy conversion systems, and they help utility planners and grid system operators understand the impacts of solar resource variability. The accuracy of solar radiation measured by radiometers depends on the instrument performance specification, installation method, calibration procedure, measurement conditions, maintenance practices, location, and environmental conditions. This study addresses the effect of calibration methodologies and the resulting calibration responsivities provided by radiometric calibration service providers such as the National Renewable Energy Laboratory (NREL) and manufacturers of radiometers. Some of these radiometers are calibrated indoors, and some are calibrated outdoors. To establish or understand the differences in calibration methodology, we processed and analyzed field-measured data from these radiometers. This study investigates calibration responsivities provided by NREL's broadband outdoor radiometer calibration (BORCAL) and a few prominent manufacturers. The reference radiometer calibrations are traceable to the World Radiometric Reference. These different methods of calibration demonstrated 1% to 2% differences in solar irradiance measurement. Analyzing these values will ultimately assist in determining the uncertainties of the radiometer data and will assist in developing consensus on a standard for calibration.

14 SOLAR ENERGY↗

A Common Calibration Source Framework for Fully-Polarimetric and Interferometric Radiometers

Two types of microwave radiometry--synthetic thinned array radiometry (STAR) and fully-polarimetric (FP) radiometry--have received increasing attention during the last several years. STAR radiometers offer a technological solution to achieving high spatial resolution imaging from orbit without requiring a filled aperture or a moving antenna, and FP radiometers measure extra polarization state information upon which entirely new or more robust geophysical retrieval algorithms can be based. Radiometer configurations used for both STAR and FP instruments share one fundamental feature that distinguishes them from more 'standard' radiometers, namely, they measure correlations between pairs of microwave signals. The calibration requirements for correlation radiometers are broader than those for standard radiometers. Quantities of interest include total powers, complex correlation coefficients, various offsets, and possible nonlinearities. A candidate for an ideal calibration source would be one that injects test signals with precisely controllable correlation coefficients and absolute powers simultaneously into a pair of receivers, permitting all of these calibration quantities to be measured. The complex nature of correlation radiometer calibration, coupled with certain inherent similarities between STAR and FP instruments, suggests significant leverage in addressing both problems together. Recognizing this, a project was recently begun at NASA Goddard Space Flight Center to develop a compact low-power subsystem for spaceflight STAR or FP receiver calibration. We present a common theoretical framework for the design of signals for a controlled correlation calibration source. A statistical model is described, along with temporal and spectral constraints on such signals. Finally, a method for realizing these signals is demonstrated using a Matlab-based implementation.

Kim, Edward J.↗

Bayesian Estimation of Precipitation from Satellite Passive Microwave Observations Using Combined Radar-Radiometer Retrievals

Precipitation estimation from satellite passive microwave radiometer observations is a problem that does not have a unique solution that is insensitive to errors in the input data. Traditionally, to make this problem well posed, a priori information derived from physical models or independent, high-quality observations is incorporated into the solution. In the present study, a database of precipitation profiles and associated brightness temperatures is constructed to serve as a priori information in a passive microwave radiometer algorithm. The precipitation profiles are derived from a Tropical Rainfall Measuring Mission (TRMM) combined radar radiometer algorithm, and the brightness temperatures are TRMM Microwave Imager (TMI) observed. Because the observed brightness temperatures are consistent with those derived from a radiative transfer model embedded in the combined algorithm, the precipitation brightness temperature database is considered to be physically consistent. The database examined here is derived from the analysis of a month-long record of TRMM data that yields more than a million profiles of precipitation and associated brightness temperatures. These profiles are clustered into a tractable number of classes based on the local sea surface temperature, a radiometer-based estimate of the echo-top height (the height beyond which the reflectivity drops below 17 dBZ), and brightness temperature principal components. For each class, the mean precipitation profile, brightness temperature principal components, and probability of occurrence are determined. The precipitation brightness temperature database supports a radiometer-only algorithm that incorporates a Bayesian estimation methodology. In the Bayesian framework, precipitation estimates are weighted averages of the mean precipitation values corresponding to the classes in the database, with the weights being determined according to the similarity between the observed brightness temperature principal components and the brightness temperature principal components of the classes. Because the classes are stratified by the sea surface temperature and the echo-top-height estimator, the number of classes that are considered for retrieval is significantly smaller than the total number of classes, making the algorithm computationally efficient. The radiometer-only algorithm is applied to TMI observations, and precipitation estimates are compared with combined TRMM precipitation radar (PR) TMI reference estimates. The TMI-only algorithm, supported by the empirically derived database, produces estimates that are more consistent with the reference values than the precipitation estimates from the version-6 TRMM facility TMI algorithm. Cloud-resolving model simulations are used to assign a latent heating profile to each precipitation profile in the empirically derived database, making it possible to estimate latent heating using the radiometer-only algorithm. Although the evaluation of latent heating estimates in this study is preliminary, because realistic conditional probability distribution functions are attached to latent heating structures in the algorithm s database, a generally positive impact on latent heating estimation from passive microwave observations is expected.

Grecu, Mircea↗

Lessons Learned from the Aquarius Radiometer Engineering Model

The Aquarius instrument is a combination microwave radiometer and scatterometer operating in the L-band for the measurement of sea surface salinity (SSS) over the open-ocean. "The Aquarius science goals are to observe and model the processes that relate salinity variations to climatic changes in the global cycling of water and to understand how these variations influence the general ocean circulation. By measuring salinity globally and synoptically every month for 3 years, Aquarius will provide an unprecedented new view of the ocean's role in climate." (http://aquarius.asfc.nasa.gov on Jan. 4, 2007). To launch in 2009, Aquarius will provide 8-day global coverage and monthly-averaged salinity maps at approx.120-km spatial resolution. Because the microwave emissivity of the ocean surface is weakly dependent upon salinity, the Aquarius radiometer remain sufficiently stable to provide accurate salinity measurements. An engineering model (EM) of one radiometer receiver was developed and tested for functionality and performance at NASA's Goddard Space Flight Center. It was tested for long-term stability starting July 27,2006. Two discrepancies where found at the start of testing and a four-month correction process ensued. This paper covers the testing and debugging of the EM radiometer through resolution of the problems. The radiometer is required to have calibration stability of less than or equal to 0.15 K over 7 days. The radiometer is in a three-beam push-broom configuration with each beam being an independent three-state Dicke radiometer (antenna, reference load, and additive noise). Internal noise diodes and reference loads provide periodic and rapid calibration of the receiver. Front-end loss contributions must be corrected as the lossy components are outside the calibration loop. A key design feature for obtaining stability is active thermal control of the front-end lossy components and the RF receiver. The thermal stability is predicted to be about 0.1 C over an orbit and no more than 1 C over a year. The radiometric stability requirement is 0.13 K rms 1 7 days without using temperature corrections. Temperature corrections and post-launch calibration are expected to extend the stability period through the life of the mission.

Piepmeier, Jeffrey↗

Characterization of a Radiometer Window for Mars Aftbody Heating Including Ablation Product Deposition Using a Miniature Arc Jet

The Mars Entry, Descent, and Landing Instrumentation 2 (MEDLI2) sensor suite for the Mars 2020 mission includes a radiometer on the backshell to measure the radiative heating during entry into the Martian atmosphere. Thermal Protection System (TPS) ablation products may be deposited on the radiometer window which would degrade the transmission and thus alter the accuracy of the radiometer readings. Testing in NASA Ames Research Center's miniature arc jet (mARC) facility was conducted to deposit TPS ablation products on radiometer windows in an effort to characterize how the ablation products change the window transmission and thus alter radiometer performance. Heat flux and stagnation pressure characterization of the mARC facility in a 90 percent CO2, 10 percent N2 (by mass) Mars-like environment are presented. The spectral transmission of the radiometer windows before and after mARC testing are compared. Additionally, a discussion of how flight-like these test conditions were and future work to further characterize the effect of TPS ablation on radiometer performance are presented.

Miller, Ruth A.↗

Geophysical Retrievals and Cloud Analyses from Merged Airborne Radiometer Datasets Covering 10–684 GHz

Airborne microwave radiometers provide insight about numerous aspects of Earth’s atmosphere and yield critical validation datasets for spaceborne radiometers. Three radiometers that are important to NASA’s airborne remote-sensing arsenal include: the Advanced Microwave Precipitation Radiometer (AMPR), covering 10–85 GHz; the Conical Scanning Millimeter-wave Imaging Radiometer (CoSMIR), covering 50–183 GHz; and the Compact Scanning Submillimeter-wave Imaging Radiometer (CoSSIR), covering 170–684 GHz. The NASA field campaigns of interest to this study include: the Integrated Precipitation and Hydrology Experiment (IPHEx) in 2014, the Olympic Mountains Experiment and Radar Definition Experiment (OLYMPEX/RADEX) in 2015–2016, the Investigation of Microphysics and Precipitation for Atlantic Coast-Threatening Snowstorms (IMPACTS) in 2020–2023, and the Airborne Lightning Observatory for FEGS and TGFs (ALOFT) in 2023. To provide a more comprehensive perspective on clouds and precipitation observed during these airborne field campaigns, AMPR data were merged spatiotemporally with CoSMIR data for IPHEx, OLYMPEX/RADEX, and IMPACTS (2020 and 2022), while considering differences in instrument characteristics and operations, providing brightness temperature (Tb) values from 10–183 GHz in a common background grid throughout each flight. AMPR and CoSSIR data were similarly merged for IMPACTS (2023) and ALOFT, providing a common background grid with Tb values covering 10–684 GHz throughout each flight. These merged Tb data were employed in geophysical retrievals using the Community Radiative Transfer Model (CRTM), an Eddington radiative transfer model, and a one-dimensional variational (1DVAR) inversion method. Retrievals of cloud liquid water path were of primary interest. This presentation will include an overview of the methods for the radiometer data mergers, the radiative transfer methods, the geophysical retrievals, and detailed results from examining trends in Tb and cloud liquid water path in clouds, precipitation, and cloud-to-precipitation transition zones.

Corey G Amiot↗

Radiometer calibration methods and resulting irradiance differences

Accurate solar radiation measured by radiometers depends on instrument performance specifications, installation method, calibration procedure, measurement conditions, maintenance practices, location, and environmental conditions. This study addresses the effect of different calibration methodologies and resulting differences provided by radiometric calibration service providers such as the National Renewable Energy Laboratory (NREL) and manufacturers of radiometers. Some of these methods calibrate radiometers indoors and some outdoors. To establish or understand the differences in calibration methodologies, we processed and analyzed field-measured data from radiometers deployed for 10 months at NREL's Solar Radiation Research Laboratory. These different methods of calibration resulted in a difference of ±1% to ±2% in solar irradiance measurements. Here by analyzing these differences will ultimately assist in determining the uncertainties of the field radiometer data and will help develop a consensus on a standard for calibration. Further advancing procedures for precisely calibrating radiometers to world reference standards that reduce measurement uncertainties will help the accurate prediction of the output of planned solar conversion projects and improve the bankability of financing solar projects.

14 SOLAR ENERGY↗

Development of two-band infrared radiometer for irradiance calibration of target simulators

A detector-based spectral radiometer has been developed for the calibration of target simulator. Unlike the conventional spectral irradiance calibration method based on radiance and irradiance, the new radiometer is calibrated using image-space temperature based method. The image-space temperature based method improves the reproducibility in the calibration of radiometer and reduces the uncertainties existing in the conventional calibration methods. The calibrated radiometer is then used to establish the irradiance transfer standard for the target simulator. With the designed radiometer in this paper, a highly accurate irradiance calibration for target simulators of wavelength from 2.05 to 2.55 μm and from 3.7 to 4.8 μm can be performed with an expanded uncertainty (k = 2) of calibration of 2.18%. Last but not least, the infrared radiation of the target simulator was measured by the infrared radiometer, the effectiveness and capability of which are verified through measurement of temperature and irradiance and a comparison with the thermal imaging camera.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radiometer for accurate (+ or - 1%) measurement of solar irradiance equal to 10,000 solar constants

The 10,000 solar constant radiometer was developed for the accurate (+ or - 1%) measurement of the irradiance produced in the image formed by a parabolic reflector or by a multiple mirror solar installation. This radiometer is water cooled, weighs about 1 kg, and is 5 cm (2 in.) in diameter by 10 cm (4 in.) long. A sting is provided for mounting the radiometer in the solar installation capable of measuring irradiances as high as 20,000 solar constants, the instrument is self calibrating. Its accuracy depends on the accurate determination of the cavity aperture, and absorptivity of the cavity, and accurate electrical measurements. The spectral response is flat over the entire spectrum from far UV to far IR. The radiometer responds to a measurement within 99.7% of the final value within 8 s. During a measurement of the 10,000 solar constant irradiance, the temperature rise of the water is about 20 C. The radiometer has perfect cosine response up to 60 deg off the radiometer axis.

Kendall, J. M., Sr.↗

Development of UHF radiometer

A wideband multifrequency UHF radiometer was initially developed to operate in the 500 to 710 MHz frequency range for the remote measurement of ocean water salinity. However, radio-frequency interference required a reconfiguration to operate in the single-frequency radio astronomy band of 608 to 614 MHz. Details of the radiometer development and testing are described. Flight testing over variable terrain provided a performance comparison of the UHF radiometer with an L-band radiometer for remote sensing of geophysical parameters. Although theoretically more sensitive, the UHF radiometer was found to be less desirable in practice than the L-band radiometer.

Kendall, B. M.↗

Radiometer system requirements for microwave remote sensing from satellites

An area of increasing interest is the establishment of a significant research program in microwave remote sensing from satellites, particularly geosynchronous satellites. Due to the relatively small resolution cell sizes, a severe requirement is placed on beam efficiency specifications for the radiometer antenna. Geostationary satellite microwave radiometers could continuously monitor several important geophysical parameters over the world's oceans. These parameters include the columnar content of atmospheric liquid water (both cloud and rain) and water vapor, air temperature profiles, and possibly sea surface temperature. Two principle features of performance are of concern. The first is the ability of the radiometer system to resolve absolute temperatures with a very small absolute error, a capability that depends on radiometer system stability, on frequency bandwidth, and on footprint dwell time. The second is the ability of the radiometer to resolve changes in temperature from one resolution cell to the next when these temperatures are subject to wide variation over the overall field-of-view of the instrument. Both of these features are involved in the use of the radiometer data to construct high-resolution temperature maps with high absolute accuracy.

Juang, Jeng-Nan↗

Development of a Submillimeter/Far-Infrared Radiometer for Cirrus Measurements

We introduce a low-cost, lightweight and compact polarisation-sensitive radiometer for the measurement of Cirrus clouds in the submillimeter and far-infrared region (10 150 cm-1). It is widely recognised that enhanced global measurements of cirrus properties are essential to the development of General Circulation and Climate Prediction Models since cirrus clouds have a strong effect on the Earth's Global Radiation Budget. The purpose of this project is to design and build a novel instrument suitable for aircraft deployment in order to measure Ice Water Path (IWP) along with cirrus particle size and shape. This airborne instrument, which is currently under development in Cardiff, will serve as a prototype for a future satellite-based radiometer. The radiometer will capitalize on the ongoing measurements of the NASA-led, Fourier Transform interferometer-based, FIRSC (Far-Infrared Sensor for Cirrus) instrument for which Cardiff has been closely associated. Data from FIRSC campaigns is being used to select optimum radiometer channels that exhibit good sensitivity to specific cirrus. This new multichannel radiometer will, however, have some key advantages over similar spectroscopic instruments, for example, portability, increased optical efficiency, a multi-angle field of view and a reduced integration period leading to an improved spatial resolution. The radiometer will benefit from the application of state-of-the-art submm/FIR polarizer and solid filter technology currently being developed in Cardiff. The instrument will require a detector array that is robust enough to withstand aircraft/space deployment.

Hayton, Darren↗

1999-2003 Shortwave Characterizations of Earth Radiation Budget Satellite (ERBS)/Earth Radiation Budget Experiment (ERBE) Broadband Active Cavity Radiometer Sensors

From October 1984 through May 2005, the NASA Earth Radiation Budget Satellite (ERBS/ )/Earth Radiation Budget Experiment (ERBE)ERBE nonscanning active cavity radiometers (ACR) were used to monitor long-term changes in the earth radiation budget components of the incoming total solar irradiance (TSI), earth-reflected TSI, and earth-emitted outgoing longwave radiation (OLR). From September1984 through September 1999, using on-board calibration systems, the ERBS/ERBE ACR sensor response changes, in gains and offsets, were determined from on-orbit calibration sources and from direct observations of the incoming TSI through calibration solar ports at measurement precision levels approaching 0.5 W/sq m , at satellite altitudes. On October 6, 1999, the onboard radiometer calibration system elevation drive failed. Thereafter, special spacecraft maneuvers were performed to observe cold space and the sun in order to define the post-September 1999 geometry of the radiometer measurements, and to determine the October 1999-September 2003 ERBS sensor response changes. Analyses of these special solar and cold space observations indicate that the radiometers were pointing approximately 16 degrees away from the spacecraft nadir and on the anti-solar side of the spacecraft. The special observations indicated that the radiometers responses were stable at precision levels approaching 0.5 W/sq m . In this paper, the measurement geometry determinations and the determinations of the radiometers gain and offset are presented, which will permit the accurate processing of the October 1999 through September 2003 ERBE data products at satellite and top-of-the-atmosphere altitudes.

Lee, Robert B., III↗

GPM Plans for Radiometer Intercalibration

The international Global Precipitation Measurement (GPM) mission led by NASA and JAXA is planned as a multi-radiometer constellation mission. A key mission component is the ability to intercalibrate the Tb from the partner constellation radiometers and create inter-calibrated, mission consistent Tc. One of the enabling strategies for this approach is the launching of a joint NASA/JAXA core satellite which contains a JAXA/NICT provided dual precipitation radar and a NASA provided Microwave Imaging passive radiometer. The observations from these instruments on the core satellite provide the opportunity to develop a transfer reference standard that can then be applied across the partner provided constellation radiometers that enables the creation of mission consistent brightness temperatures. The other aspect of the strategy is the development of a community consensus intercalibration algorithm that will be applied to the Tb observations from partner radiometers and create the best calibrated Tc. Also described is the development of the framework in which the inter-calibration is included in the final algorithm. A part of the latter effort has been the development of a generic, logical structure which can be applied across radiometer types and which guarantees the user community that key information for using Tc properly is recorded. Key

Stocker, Erich Franz↗

Single-Pole Double-Throw MMIC Switches for a Microwave Radiometer

In order to reduce the effect of gain and noise instabilities in the RF chain of a microwave radiometer, a Dicke radiometer topology is often used, as in the case of the proposed surface water and ocean topography (SWOT) radiometer instrument. For this topology, a single-pole double-throw (SPDT) microwave switch is needed, which must have low insertion loss at the radiometer channel frequencies to minimize the overall receiver noise figure. Total power radiometers are limited in accuracy due to the continuous variation in gain of the receiver. High-frequency SPDT switches were developed in the form of monolithic microwave integrated circuits (MMICs) using 75 micron indium phosphide (InP) PIN-diode technology. These switches can be easily integrated into Dicke switched radiometers that utilize microstrip technology.

Montes, Oliver↗

Science Objectives of the ACCP/AOS Millimeter- and Submillimeter-Wave Radiometers

Passive microwave radiometers provide highly useful information regarding the Earth system by measuring thermal emission (from the surface and atmosphere) that is reflected, absorbed, and scattered by the surface and the atmosphere. As such, radiometers have been instrumental across Earth-observing concepts with heritage tracing back to the Nimbus era, and clouds and precipitation have been key geophysical phenomena these sensors have targeted. As millimeter-wave (particularly ≥85 GHz) and submillimeter-wave technologies have advanced, the applicability of microwave radiometers has expanded to encompass falling snow and ice clouds, respectively. Given the strong heritage of microwave radiometry and the emergence of submillimeter-wave sensors for sensing falling snow and ice clouds, the National Academies’ 2017 Decadal Survey for Earth Science and Applications from Space recommended passive sensors covering these wavelengths be included in observing systems that address the Aerosols, Clouds, Convection, and Precipitation (ACCP) combined designated observable. To showcase the capabilities for addressing the ACCP science objectives, we will provide an overview of the passive microwave capabilities envisioned for the Atmosphere Observing System (AOS, part of the recently unveiled NASA Earth System Observatory), including descriptions of the radiometers for the inclined and polar orbits and the primary geophysical variables of interest related to ice-phase clouds and precipitation. We will also discuss secondary science objectives, such as precipitation mapping, that can be achieved with the ACCP/AOS radiometers. Examples from the analyses performed for the ACCP/AOS architecture study and subsequent sensor definition exercises will be presented, outlining the basis for the radiometer configuration within the context of the overarching ACCP/AOS goals to elucidate the connections between atmospheric dynamics, weather (including extreme events), air quality, and climate.

Ian S Adams↗

Soil Moisture Active/Passive (SMAP) L-band Microwave Radiometer Post-Launch Calibration Revisit: Approach and Performance

The SMAP microwave radiometer is a fully-polarimetric L-band radiometer flown on the SMAP satellite in a 6 AM / 6 PM sun-synchronous orbit at 685-km altitude. After the SMAP L1B_TB data product version4was released in 2018, the radiometer has undergonefurther calibration and validation. The goal isto reducethe difference between antenna temperature (TA) ofascending and descending orbits during the eclipse, andto reduce the dips in the calibration drift over the Cold Sky (CS) during the eclipse seasons in 2017 and 2018. The post-launch calibration algorithmhas been revisitedby retrieving all of the calibration parameters simultaneouslywith two different options for thehot calibration source(theglobal ocean, or the radiometer internal reference load). The performance of the two options are compared here. Theoption with the radiometer internal reference load has been chosen by the SMAP science team for data release version 5. In addition, a correction offset is applied to the input signal to account for offsets during the early-mission stages with theSMAP SAR transmitter operating alongside the radiometer.

Jinzheng Peng↗

Design, Calibration, and Application of A Cryogenic Low-Background Infrared Radiometer for Spectral Irradiance and Radiance Measurements From 4- to 20-μm Wavelength

We have constructed, calibrated, and tested a cryogenic low-background infrared (IR) radiometer for both spectral radiance and irradiance measurements over the 4- to 20-μm wavelength range. The primary purpose of the Missile Defense Transfer Radiometer (MDXR) is to measure absolute irradiance or radiance from cryogenic IR test chamber sources using a photoconductive Si:As blocked-impurity band (BIB) detector and a set of spectral filters. The MDXR also includes an absolute cryogenic radiometer (ACR) and a Fourier-transform spectrometer (FTS). For irradiance measurements, the ACR is used to provide the primary power scale for the BIB detector in conjunction with spectral filters, whereas the FTS/BIB configuration derives its scale from an internal blackbody source. The two measurement scales show agreement for the irradiance of highly collimated (<1 mrad) IR beams from 10 -13 to 10 -8 W / μm / cm 2 within the combined relative uncertainties of 2.6% (coverage factor k = 1.) We have also calibrated the radiometer for radiance measurements using a large cavity fluid bath blackbody that overfills the spatial and angular extent of the radiometer entrance pupil. The radiometric calibration uncertainty analysis of the radiometer and its maintenance and stability are discussed.

radiometry↗