At least 55 records · Page 3

Design and validation of a fission-product source for radioactive beams

A neutron-generator-based source of fission products (nuCARIBU) is being developed to replace the existing source at Argonne National Laboratory. Neutrons generated by reaction are thermalized in a compact polyethylene [(moderator and impinge on a thin 235 U foil to produce fission products. Experiments have been conducted to verify the nuCARIBU concept and simulation results using a 4 MeV, 0.16 µ⁢A proton beam from the ATLAS accelerator irradiating a LiF neutron production target and two different simplified versions of the nuCARIBU (C 2 ⁢H 4 ) n moderator with thicknesses of 3.81 cm and 1.91 cm separating it from the enriched 235 U fission foil. Here, the emitted γ-ray peaks of 1383.93 keV ( 92 Sr), 358.0 keV ( 104 Tc), 565.992 keV ( 134 Te), and 258.411 keV ( 138 Xe) obtained from fission products are used to determine the neutron-induced fission rates in the fission foil. The measured fission rates are in good agreement with those simulated using the PHITS Monte Carlo code with user-defined neutron production cross sections based on well-known cross section data. These experimental results, consistent with the simulations, show that the current 252 Cf source (CARIBU) can be replaced by the neutron induced fission source (nuCARIBU).

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Progress of the laser ion source upgrade (LION2) for RHIC and NSRL program at Brookhaven National Laboratory

At Brookhaven National Laboratory (BNL), the LION2 ion source is being constructed to replace an existing laser ion ablation ion source (LIS) at the EBIS facility, which provides heavy ion beams of multiple ion species for the operation of NASA Space Radiation Laboratory (NSRL) and Relativistic Heavy Ion Collider (RHIC). The LION1 ion source currently provides singly charged ions of Li, B, C, O, Al, Si, Ca, Ti, Fe, Cu, Zr, Nb, Ag, Tb, Ta, W, Au, Bi, and Th with a rapid-species-change capability. An electron beam ion source, Extended-EBIS captures, confines, and ionizes the ions to high charge state, suitable for injection and acceleration by an RFQ accelerator. Typically, single pulses of the LIS ion species for NSRL are changed sequentially during Galactic Cosmic Ray experiments, while multiple pulses of a given ion beam are provided quasi-simultaneously for RHIC. LION2 will have the same capability of the rapid-species-change with improved beam performance and reliability. LION2 is being constructed in a remote assembly location and is expected to finish in December 2023. The removal of LION1 and installation of LION2 is planned during the December 2023 or summer 2024 shutdown.

43 PARTICLE ACCELERATORS↗

Portable Intravenous Fluid Production Device For Ground Use Project

Several medical conditions require the administration of intravenous (IV) fluids,but limitations of mass, volume, shelf-life, transportation, and local resources can restrict the availability of these important fluids. Such limitations are expected in long-duration space exploration missions and in remote or austere places on Earth. This design uses regular drinking water that is pumped through two filters to produce, in minutes, sterile, ultrapure water that meets the stringent quality standards of the United States Pharmacopeia for Water for Injection (Total Bacteria, Conductivity, Endo - toxins, Total Organic Carbon). The device weighs 2.2 lb (1 kg) and is 10 in. long, 5 in. wide, and 3 in. high (≈25, 13, and 7.5 cm, respectively) in its storage configuration. This handheld device produces one liter of medical-grade water in 21 minutes. Total production capacity for this innovation is expected to be in the hundreds of liters. The device contains one battery powered electric mini-pump. Alternatively, a manually powered pump can be attached and used. Drinking water enters the device from a source water bag, flows through two filters, and final sterile production water exits into a sealed, medical-grade collection bag. The collection bag contains pre-placed crystalline salts to mix with product water to form isotonic intravenous medical solutions. Alternatively, a hypertonic salt solution can be injected into a filled bag. The filled collection bag is detached from the device and is ready for use or storage. This device currently contains one collection bag, but a manifold of several pre-attached bags or replacement of single collection bags under sterile needle technique is possible for the production of multiple liters. The entire system will be flushed, sealed, and radiation-sterilized. Operation of the device is easy and requires minimal training. Drinking water is placed into the collection bag. Inline stopcock flow valves at the source and collection bags are opened, and the mini-pump is turned on by a switch to begin fluid flow. When the collection bag is completely filled with the medical- grade water, the pump can be turned off. The pump is designed so it cannot pump air, and overfilling of the collection bag with fluid is avoided by placing an equal amount of water in the source bag. Backflow is avoided by inline check valves. The filled collection bag is disconnected from its tubing and is ready for use. The source bag can be refilled for production of multiple liters, or the source bag can be replaced with an input tube that can be placed in a larger potable water source if the device is attended. The device functions in all orientations independent of any gravity fields. In addition to creating IV fluids, the device produces medical-grade water, which can be used for mixing with medications for injection, reconstituting freeze-dried blood products for injection, or for wound hydration or irrigation. Potential worldwide use is expected with medical activities in environments that have limited resources, storage, or resupply such as in military field operations, humanitarian relief efforts, submarines, commercial cruise ships, etc.

Technology Portfolio System↗

Characteristics of RF resulting from dielectric discharges

This paper presents measurements of the electromagnetic radiation pulses and the replacement current pulses which result from the breakdown of Mylar and Kapton samples. The observed dependence of the characteristics of the replacement current pulse as a function of electron beam energy is discussed. The characteristics of the electromagnetic radiation pulses are also analyzed in the text of this paper. The source of the irradiating electrons is a monoenergetic electron beam whose energy was varied from 12.5 KeV to 25 KeV.

Leung, P.↗

Meteorological, reference evapotranspiration and estimated transpiration data, July 2020-Dec 2021, Slate River Floodplain, Crested Butte, Colorado

This data package includes a time series of meteorological data (air temperature, relative humidity, barometric pressure, precipitation, wind speed, soil heat flux, incoming shortwave radiation, incoming longwave radiation, outgoing shortwave radiation and outgoing longwave radiation) from the Slate River floodplain outside Crested Butte, Colorado, a focus field site for the SLAC Floodplain Hydro-Biogeochemistry SFA. The data was generated as part of the work targeting the overarching research question for the SLAC SFA: How do ubiquitous subsurface interfaces mediate molecular-scale biogeochemical processes and groundwater quality in floodplains and watersheds? The package also includes reference evapotranspiration calculated via the Penman-Monteith equation and an estimate of willow (Salix spp.) evapotranspiration using the method of Irmak et al., J. Hydrology, 2013. Due to two malfunctioning sensors (incoming shortwave radiation from Oct 2020-May 2021 and incoming longwave radiation from May 2021-March 2022), observed net radiation and calculated evapotranspiration are only included from July-October 2020. However, users may be able to extend calculated evapotranspiration using estimates of these two parameters from other sources. Both sensors have been replaced and data beyond 2021 be uploaded to this repository when it is available.Within the data package, "FLMD.csv" describes file-level metadata and "dd.csv" defines column headers and universal terms across the dataset. The data package includes 3 "*data.csv" files, two for meteorological data for 2020 and 2021 and one for reference evapotranspiration and transpiration data from 2020 ("SLT_OBJ2_PenmanMonteith_2020_data.csv"). Each "*data.csv" file of meteorological data has a corresponding "*_InstallationMethods.csv" file that describes the location, sensor model, sensor serial number and other metadata corresponding to each measured parameter. We also include a Jupyter notebook ("PenmanMonteithET_Calculations.ipynb") that details the assumptions and equations used to calculate daily and hourly reference evapotranspiration and daily willow transpiration from raw meteorological data.

54 ENVIRONMENTAL SCIENCES↗

Design of a Cryogenic Assembly for Comparing Qubit Infrared Packaging Inefficiencies

It is well known that everything emits infrared (IR) light in the form of thermal radiation. IR radiation on superconducting qubits carries enough energy to cause decoherence and so-called “quasiparticle poisoning.” Therefore, proper IR shielding is needed to keep the qubit in a high coherence state. However, trying to extract IR-specific information from a qubit is difficult, so a microwave kinetic inductance detector (MKID) can be used instead. We show that the IR shielding inefficiencies of MKID packages can only be compared with other packaging inefficiencies. We create a cryogenic assembly CAD design, consisting of magnetic shield cans, a copper mounting plate and mounts, and an MKID enclosure, which thermalizes the assembly to dilution refrigerator temperatures. Phase 1 of this design involves using a narrowband IR laser source to test the IR shielding of packaging at the laser’s wavelength. When the best IR shielding packaging is determined, the superconducting qubit can replace the MKID, allowing the qubit to avoid decoherence due to IR radiation and boost its performance and coherence lifetime.

Mailliard, Robert J. [Fermilab] (ORCID:00090000277↗

Design of a Cryogenic Assembly for Comparing Qubit Infrared Packaging Inefficiencies

It is well known that everything emits infrared (IR) light in the form of thermal radiation. IR radiation on superconducting qubits carries enough energy to cause decoherence and so-called “quasiparticle poisoning.” Therefore, proper IR shielding is needed to keep the qubit in a high-coherence state. However, trying to extract IR-specific information from a qubit is difficult, so a microwave kinetic inductance detector (MKID) can be used instead. We show that the IR shielding inefficiencies of MKID packages can only be compared with other packaging inefficiencies. We create a cryogenic assembly CAD design, consisting of magnetic shield cans, a copper mounting plate and mounts, and an MKID enclosure, which thermalizes the assembly to dilution refrigerator temperatures. Phase 1 of this design involves using a narrowband IR laser source to test the IR shielding of packaging at the laser’s wavelength. When the best IR shielding packaging is determined, the superconducting qubit can replace the MKID, allowing the qubit to avoid decoherence due to IR radiation and boost its performance and coherence lifetime.

Mailliard, Robert J. [Fermilab] (ORCID:00090000277↗

Design of a Cryogenic Assembly for Comparing Qubit Infrared Packaging Inefficiencies

It is well known that everything emits infrared (IR) light in the form of thermal radiation. IR radiation on superconducting qubits carries enough energy to cause decoherence and so-called “quasiparticle poisoning.” Therefore, proper IR shielding is needed to keep the qubit in a high-coherence state. However, trying to extract IR-specific information from a qubit is difficult, so a microwave kinetic inductance detector (MKID) can be used instead. We show that the IR shielding inefficiencies of MKID packages can only be compared with other packaging inefficiencies. We create a cryogenic assembly CAD design, consisting of magnetic shield cans, a copper mounting plate and mounts, and an MKID enclosure, which thermalizes the assembly to dilution refrigerator temperatures. Phase 1 of this design involves using a narrowband IR laser source to test the IR shielding of packaging at the laser’s wavelength. When the best IR shielding packaging is determined, the superconducting qubit can replace the MKID, allowing the qubit to avoid decoherence due to IR radiation and boost its performance and coherence lifetime.

Mailliard, Robert J. [Fermilab] (ORCID:00090000277↗

Design of a Cryogenic Assembly for Comparing Qubit Infrared Packaging Inefficiencies

It is well known that everything emits infrared (IR) light in the form of thermal radiation. IR radiation on superconducting qubits carries enough energy to cause decoherence and so-called “quasiparticle poisoning.” Therefore, proper IR shielding is needed to keep the qubit in a high-coherence state. However, trying to extract IR-specific information from a qubit is difficult, so a microwave kinetic inductance detector (MKID) can be used instead. We show that the IR shielding inefficiencies of MKID packages can only be compared with other packaging inefficiencies. We create a cryogenic assembly CAD design, consisting of magnetic shield cans, a copper mounting plate and mounts, and an MKID enclosure, which thermalizes the assembly to dilution refrigerator temperatures. Phase 1 of this design involves using a narrowband IR laser source to test the IR shielding of packaging at the laser’s wavelength. When the best IR shielding packaging is determined, the superconducting qubit can replace the MKID, allowing the qubit to avoid decoherence due to IR radiation and boost its performance and coherence lifetime.

Mailliard, Robert J. [Fermilab] (ORCID:00090000277↗

CMS Outer Tracker Module QA

It is well known that everything emits infrared (IR) light in the form of thermal radiation. IR radiation on superconducting qubits carries enough energy to cause decoherence and so-called “quasiparticle poisoning.” Therefore, proper IR shielding is needed to keep the qubit in a high-coherence state. However, trying to extract IR-specific information from a qubit is difficult, so a microwave kinetic inductance detector (MKID) can be used instead. We show that the IR shielding inefficiencies of MKID packages can only be compared with other packaging inefficiencies. We create a cryogenic assembly CAD design, consisting of magnetic shield cans, a copper mounting plate and mounts, and an MKID enclosure, which thermalizes the assembly to dilution refrigerator temperatures. Phase 1 of this design involves using a narrowband IR laser source to test the IR shielding of packaging at the laser’s wavelength. When the best IR shielding packaging is determined, the superconducting qubit can replace the MKID, allowing the qubit to avoid decoherence due to IR radiation and boost its performance and coherence lifetime.

Hobbeheydar, Samuel [Carnegie Mellon U. (main); Fe↗

Comparison of Measured and Calculated Dose Rates for Ring Injection Dump Exchange at Spallation Neutron Source

According to the accelerator operation plan, the beam-stop and the proton beam window (PBW) assemblies of the existing Ring Injection Dump RID are replaced with fresh assemblies, when they have reached their end-of-life. End of-life is determinate by the stainless-steel beam-stop window having accumulated 10 dpa radiation damage. The exchange process took place during facility maintenance period that started in March 2023. Each of the spent assembles were put into specially designed storage containers temporarily residing near the RID building.The spent beam-stop is predicted to be the part of highest activation that has been removed in Spallation Neutron Source (SNS). The exchange processes require good work planning to minimize radiation exposure to personal. For each exchange step the residual dose rate distribution is calculated and the peak values are identified. This paper gives some examples of calculated vs measured doses during beam-stop assembly exchange.

Popova, Irina I.↗

Bone mineral measurement using dual energy x ray densitometry

Bone mineral measurements before and after space missions have shown that weightlessness greatly accelerates bone demineralization. Bone mineral losses as high as 1 to 3 percent per month were reported. Highly precise instrumentation is required to monitor this loss and thereby test the efficacy of treatment. During the last year, a significant improvement was made in Dual-Photon Absorptiometry by replacing the radioactive source with an x ray tube. Advantages of this system include: better precision, lower patient dose, better spacial resolution, and shorter scan times. The high precision and low radiation dose of this technique will allow detection of bone mineral changes of less than 1 percent with measurements conducted directly at the sites of interest. This will allow the required bone mineral studies to be completed in a shorter time with greater confidence.

Smith, Steven W.↗

A Deconvolution Approach for the Mapping of Acoustic Sources (DAMAS) Determined from Phased Microphone Arrays

Current processing of acoustic array data is burdened with considerable uncertainty. This study reports an original methodology that serves to demystify array results, reduce misinterpretation, and accurately quantify position and strength of acoustic sources. Traditional array results represent noise sources that are convolved with array beamform response functions, which depend on array geometry, size (with respect to source position and distributions), and frequency. The Deconvolution Approach for the Mapping of Acoustic Sources (DAMAS) method removes beamforming characteristics from output presentations. A unique linear system of equations accounts for reciprocal influence at different locations over the array survey region. It makes no assumption beyond the traditional processing assumption of statistically independent noise sources. The full rank equations are solved with a new robust iterative method. DAMAS is quantitatively validated using archival data from a variety of prior high-lift airframe component noise studies, including flap edge/cove, trailing edge, leading edge, slat, and calibration sources. Presentations are explicit and straightforward, as the noise radiated from a region of interest is determined by simply summing the mean-squared values over that region. DAMAS can fully replace existing array processing and presentations methodology in most applications. It appears to dramatically increase the value of arrays to the field of experimental acoustics.

Brooks, Thomas F.↗

A Deconvolution Approach for the Mapping of Acoustic Sources (DAMAS) Determined from Phased Microphone Arrays

Current processing of acoustic array data is burdened with considerable uncertainty. This study reports an original methodology that serves to demystify array results, reduce misinterpretation, and accurately quantify position and strength of acoustic sources. Traditional array results represent noise sources that are convolved with array beamform response functions, which depend on array geometry, size (with respect to source position and distributions), and frequency. The Deconvolution Approach for the Mapping of Acoustic Sources (DAMAS) method removes beamforming characteristics from output presentations. A unique linear system of equations accounts for reciprocal influence at different locations over the array survey region. It makes no assumption beyond the traditional processing assumption of statistically independent noise sources. The full rank equations are solved with a new robust iterative method. DAMAS is quantitatively validated using archival data from a variety of prior high-lift airframe component noise studies, including flap edge/cove, trailing edge, leading edge, slat, and calibration sources. Presentations are explicit and straightforward, as the noise radiated from a region of interest is determined by simply summing the mean-squared values over that region. DAMAS can fully replace existing array processing and presentations methodology in most applications. It appears to dramatically increase the value of arrays to the field of experimental acoustics.

Brooks, Thomas F.↗

Equal abundance of summertime natural and wintertime anthropogenic Arctic organic aerosols

Aerosols play an important yet uncertain role in modulating the radiation balance of the sensitive Arctic atmosphere. Organic aerosol is one of the most abundant, yet least understood, fractions of the Arctic aerosol mass. Here we use data from eight observatories that represent the entire Arctic to reveal the annual cycles in anthropogenic and biogenic sources of organic aerosol. We show that during winter, the organic aerosol in the Arctic is dominated by anthropogenic emissions, mainly from Eurasia, which consist of both direct combustion emissions and long-range transported, aged pollution. In summer, the decreasing anthropogenic pollution is replaced by natural emissions. These include marine secondary, biogenic secondary and primary biological emissions, which have the potential to be important to Arctic climate by modifying the cloud condensation nuclei properties and acting as ice-nucleating particles. Their source strength or atmospheric processing is sensitive to nutrient availability, solar radiation, temperature and snow cover. Our results provide a comprehensive understanding of the current pan-Arctic organic aerosol, which can be used to support modelling efforts that aim to quantify the climate impacts of emissions in this sensitive region.

58 GEOSCIENCES↗

Microtron MT 25 as a source of neutrons

The objective was to describe Microtron MT25 as a source of neutrons generated by bremsstrahlung induced photonuclear reactions in U and Pb targets. Bremsstrahlung photons were produced by electrons accelerated at energy 21.6 MeV. Spectral fluence of the generated neutrons was calculated with MCNPX code and then experimentally determined at two positions by means of a Bonner spheres spectrometer in which the detector of thermal neutrons was replaced by activation Mn tablets or track detectors CR-39 with a {sup 10}B radiator. The measured neutron spectral fluence and the calculated anisotropy served for the estimation of neutron yield from the targets and for the determination of ambient dose equivalent rate at the place of measurement. Microtron MT25 is intended as one of the sources for testing neutron sensitive devices which will be sent into the space.